Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Front Public Health ; 10: 994712, 2022.
Article in English | MEDLINE | ID: mdl-36339215

ABSTRACT

The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic can be effectively controlled by rapid and accurate identification of SARS-CoV-2-infected cases through large-scale screening. Hypercube pooling polymerase chain reaction (PCR) is frequently used as a pooling technique because of its high speed and efficiency. We attempted to implement the hypercube pooling strategy and found it had a large quantization effect. This raised two questions: is hypercube pooling with edge = 3 actually the optimal strategy? If not, what is the best edge and dimension? We used a C++ program to calculate the expected number of PCR tests per patient for different values of prevalence, edge, and dimension. The results showed that every edge had a best performance range. Then, using C++ again, we created a program to calculate the optimal edge and dimension required for pooling samples when entering prevalence into our program. Our program will be provided as freeware in the hope that it can help governments fight the SARS-CoV-2 pandemic.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , COVID-19 Testing , COVID-19/diagnosis , Pandemics , Polymerase Chain Reaction
2.
Front Surg ; 9: 1000404, 2022.
Article in English | MEDLINE | ID: mdl-36311919

ABSTRACT

Distal radius orientation is important in evaluating Colles' fracture. In most cases, the wrist was protected by a bandage, splint, or cast. Therefore, it was difficult for the radiology technician to take perfect anteroposterior and lateral view radiographs. In this study, we build a mathematical model and calculate the pronation angle needed to produce dorsal tilt, which is a volar tilt in a perfect lateral view radiograph. The formulas are all incorporated into Excel to facilitate usage.

3.
Life (Basel) ; 10(7)2020 Jul 19.
Article in English | MEDLINE | ID: mdl-32707735

ABSTRACT

BACKGROUND: Adenine is a purine with a role in cellular respiration and protein synthesis. It is considered for its pharmacological potential. We investigated whether anti-inflammatory effect of adenine benefits on the proliferation and maturation of osteoblastic cells. METHODS: Human osteoblast-like cells (MG-63) were cultured with adenine under control conditions or pre-treated with 10ng/mL of tumor necrosis factor-α (TNF-α) followed by adenine treatment. Cell viability was examined using dimethylthiazol diphenyltetrazolium bromide (MTT) assay. Expression of cytokines and osteogenic markers were analyzed using quantitative PCR (qPCR) and ELISA. Enzyme activity of alkaline phosphatase (ALP) and collagen content were measured. RESULTS: TNF-α exposure led to a decreased viability of osteoblastic cells. Treatment with adenine suppressed TNF-α-induced elevation in IL-6 expression and nitrite oxide production in MG-63 cells. Adenine induced the osteoblast differentiation with increased transcript levels of collage and increased ALP enzyme activity. CONCLUSIONS: Adenine exerts anti-inflammatory activity in an inflammatory cell model. Adenine benefits osteoblast differentiation in normal and inflammatory experimental settings. Adenine has a potential for the use to treat inflammatory bone condition such as osteoporosis.

4.
BMC Musculoskelet Disord ; 21(1): 92, 2020 Feb 10.
Article in English | MEDLINE | ID: mdl-32041587

ABSTRACT

BACKGROUND: Compared to other types of surgeries, minimally invasive surgeries (MISs) of humeral shaft fractures are associated with less radial nerve injury, less soft tissue injury and higher union rate. However, malrotation often occurs in MISs when closed reduction methods are used. This study aims to define specific palpable landmarks to help surgeons determine the correct torsional angle and reduce the incidence of malrotation. METHODS: Twenty-eight normal humeral computed tomography scans were retrieved from our image database. One line was drawn through the vertices of the intertubercular sulcus of the humeral head in the coronal view, and another line was drawn through the longest axis between the medial and lateral condyles in the coronal view. The angle between these two lines was measured at least 3 times for each scan. RESULTS: The profile of the intertubercular sulcus tangent line of the humeral head and the axis of the distal humerus was identified as the most accurate method for assessing the precision of torsion during MIS for humeral shaft fractures. The transepicondylar axis line is more internally rotated than the intertubercular sulcus tangent line. The mean angle was measured to be 41.1 degrees. CONCLUSIONS: The axis of the distal humeral condyles is internally rotated by approximately 41.1 degrees compared with the intertubercular sulcus tangent line of the humeral head. Minimally invasive surgeries can be performed by using these palpable landmarks. The torsional deformities can be reduced with the proper angle adjustment without the need for fluoroscopy. It can also be used to treat unstable comminuted humeral fractures. LEVEL OF EVIDENCE: Retrospective Study, Diagnostic study, Level III.


Subject(s)
Anatomic Landmarks , Humeral Fractures/surgery , Humerus/diagnostic imaging , Torsion Abnormality/prevention & control , Adolescent , Adult , Aged , Aged, 80 and over , Female , Fracture Fixation/adverse effects , Humans , Male , Middle Aged , Minimally Invasive Surgical Procedures/adverse effects , Retrospective Studies , Tomography, X-Ray Computed , Torsion Abnormality/etiology , Young Adult
5.
Injury ; 51(2): 414-419, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31870609

ABSTRACT

INTRODUCTION: Hip fractures can be divided into intra-capsular and extra-capsular fracture based on fracture location; these two types of fracture have different pathogeneses, treatments and prognoses. Many factors influence the patterns of hip fractures, including the injury mechanism, areal bone mineral density and the geometry of the hip. However, the relationship between body composition and hip fracture pattern has not yet been discussed. In this investigation, an analysis of the body compositions of geriatric patients with hip fractures were conducted to identify differences between fat and muscle distributions between patients with intra- and extra-capsular hip fractures. MATERIAL AND METHODS: From December 2017 to February 2019, 139 patients with a hip fracture were prospectively enrolled in this study. The groups of patients that were diagnosed as having intra- and extra-capsular hip fractures were compared in terms of patient demographics, pre-operative laboratory data, bone mineral density (BMD) and body composition including muscle and fat distributions obtained using dual-energy X-ray absorptiometry (DXA) . RESULTS: Eighty-six and 53 patients were diagnosed with intra-capsular and extra-capsular hip fractures, respectively. A significantly higher serum glucose level, a lower hemoglobin level, a lower T-score level in the proximal femur region, a lower T-score of all parts of interest, and a lower percentage fat content on the region of bilateral proximal hips (gynoid region) and in the lower limb region, were observed in patients with an extra-capsular hip fracture than in those with an intra-capsular hip fracture. However, with all confounding factors controlled for, only the T-score at the proximal femur, percentage fat content in the region of bilateral proximal hips and the ratio of android fat content to gynoid fat content (A/G ratio) are the most relevant factors in predicting the patterns of hip fracture in geriatric patients after falling. CONCLUSION: This work demonstrates that lower fat content in the region of bilateral proximal hips and a lower BMD on the proximal femur may predict greater vulnerability of geriatric patients to extra-capsular rather than intra-capsular hip fracture after a falling accident.


Subject(s)
Body Fat Distribution , Bone Density , Femur/diagnostic imaging , Hip Fractures/diagnosis , Absorptiometry, Photon , Accidental Falls , Aged , Aged, 80 and over , Female , Geriatrics , Humans , Intra-Articular Fractures/diagnosis , Logistic Models , Male , Multivariate Analysis , Predictive Value of Tests
6.
PLoS One ; 14(11): e0224699, 2019.
Article in English | MEDLINE | ID: mdl-31675364

ABSTRACT

Pedicle screws are commonly used for posterior stabilization of the spine. When used in deformed or degenerated segments, the pedicle screws are often not fully inserted into the bone, but instead the threaded portion is exposed by 1 or 2 threads to accommodate rod placement and ensure alignment between the tulip of the screw and the rod. However, broken pedicle screws have been reported with the use of this method. The aim of this study was to determine how the fatigue life of the screw is affected by not fully inserting the screw into the bone. Spinal constructs were evaluated in accordance with ASTM F1717. The following three screw positions were subjected to compression bending fatigue loading; (i) pedicle screw fully inserted in the test block with no threads exposed (EXP-T0), (ii) pedicle screw inserted with one thread exposed outside the test block (EXP-T1), (iii) pedicle screw inserted with two threads exposed outside the test block (EXP-T2). Corresponding finite element models FEM-T0, FEM-T1 and FEM-T2 were also constructed and subjected to the same axial loading as the experimental groups to analyze the stress distribution in the pedicle screws and rods. The results showed that under a 190 N axial load, the EXP-T0 group survived the full 5 million cycles, the EXP-T1 group failed at 3.7 million cycles on average and the EXP-T2 groups failed at 1.0 million cycles on average, while the fatigue strength of both the EXP-T1 and EXP-T2 groups was 170 N. The constructs failed through fracture of the pedicle screw. In comparison to the FEM-T0 model, the maximum von Mises stress on the pedicle screw in the FEM-T1 and FEM-T2 models increased by 39% and 58%, respectively. In conclusion, this study demonstrated a drastic decrease in the fatigue life of pedicle screws when they are not full inserted into the plastic block.


Subject(s)
Pedicle Screws/adverse effects , Prosthesis Failure/etiology , Biomechanical Phenomena , Compressive Strength , Equipment Failure Analysis , Humans , Spine/surgery , Weight-Bearing
SELECTION OF CITATIONS
SEARCH DETAIL
...