Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Emerg Med ; 50(4): 643-50.e1, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26830361

ABSTRACT

BACKGROUND: The suprasternal notch view (SSNV) is an additional echocardiographic view not routinely used by emergency physicians (EPs) performing focused cardiac ultrasound (FOCUS). OBJECTIVE: This pilot study determined the ease and self-perceived accuracy of the SSNV as performed by EPs. Additionally, we assessed the accuracy of FOCUS including the SSNV in thoracic aortic measurements compared to chest CT angiography (CTA). METHODS: This was a prospective, observational, pilot study of adult patients undergoing chest CTA. Thoracic aortic measurements were recorded at the sinus of Valsalva, sinotubular junction, and ascending aorta at its widest diameter in the parasternal long axis (PSL) view and SSNV. EPs rated ease of acquisition and self-perceived accuracy of thoracic aorta measurements. Two blinded radiologists performed thoracic aortic CTA measurements at predefined locations corresponding to the ultrasound measurements. RESULTS: Of the 79 patients (median age 57 years) enrolled, the SSNV was obtained in 97% of cases. EPs rated the ease of obtaining the SSNV as "easy" in 64.5% of cases and "very difficult" in 7.6% of cases. The mean difference between ultrasound (FOCUS plus SSNV) and CTA measurements were 1.2 mm (95% limits of agreement -2.9 to 5.3) at the sinus of Valsalva, 1.0 mm (95% limits of agreement -5.5 to 3.6 mm) at the sinotubular junction, 0.8 mm (95% limits of agreement -6.2 to 4.6 mm) at the proximal ascending aorta, and 0.6 mm (95% limits of agreement -2.8 to 4.0) at the aortic arch. CONCLUSIONS: Our findings suggest that the SSNV is an easily attainable and accurate view of the thoracic aorta that can be obtained by EPs in the majority of ED patients.


Subject(s)
Aorta, Thoracic/diagnostic imaging , Aortic Diseases/diagnostic imaging , Echocardiography/methods , Adult , Aged , Aged, 80 and over , Emergency Service, Hospital , Female , Humans , Male , Middle Aged , Pilot Projects , Prospective Studies , Tomography, X-Ray Computed
3.
Radiology ; 273(1): 78-87, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25025582

ABSTRACT

PURPOSE: To analyze imaging utilization and emergency radiology process turnaround times in response to the April 15, 2013, Boston Marathon bombing in order to identify opportunities for improvement in the Brigham and Women's Hospital (BWH) emergency operations plan. MATERIALS AND METHODS: Institutional review board approval was obtained with waivers of informed consent. Patient demographics, injuries, and outcomes were gathered, along with measures of emergency department (ED) imaging utilization and turnaround times, which were compared with operations from the preceding year by using the Wilcoxon rank sum test. Multivariate linear regression was used to assess contributors to examination cancellations. RESULTS: Forty patients presented to BWH after the bombing; 16 were admitted and 24 were discharged home. There were no fatalities. Ten patients required emergent surgery. Blast injury types included 13 (33%) primary, 20 (51%) secondary, three (8%) tertiary, and 19 (49%) quaternary. Thirty-one patients (78%) underwent imaging in the ED; 57 radiographic examinations in 30 patients and 16 computed tomographic (CT) examinations in seven patients. Sixty-two radiographic and 14 CT orders were cancelled. Median time from blast to patient arrival was 97 minutes (interquartile range [IQR], 43-139 minutes), patient arrival to ED examination order, 24 minutes (IQR, 12-50 minutes), order to examination completion, 49 minutes (IQR, 26-70 minutes), and examination completion to available dictated text report, 75 minutes (IQR, 19-147 minutes). Examination completion turnaround times were significantly increased for radiography (52 minutes [IQR, 26-73 minutes] vs annual median, 31 minutes [IQR, 19-48 minutes]; P = .001) and decreased for CT (37 minutes [IQR, 26-50 minutes] vs annual median, 72 minutes [IQR, 40-129 minutes]; P = .001). There were no significant differences in report availability turnaround time (75 minutes [IQR, 19-147 minutes] vs annual median, 74 minutes [IQR, 35-127 minutes]; P = .34). CONCLUSION: The surge in imaging utilization after the Boston Marathon bombing stressed emergency radiology operations. Process analysis enabled identification of successes and opportunities for improvement in ongoing emergency operations planning. © RSNA, 2014.


Subject(s)
Blast Injuries/diagnosis , Diagnostic Imaging , Emergency Service, Hospital/organization & administration , Multiple Trauma/diagnosis , Patient Care Team/organization & administration , Terrorism , Adult , Aged , Blast Injuries/surgery , Bombs , Boston , Disaster Planning , Emergency Medicine , Female , Humans , Male , Mass Casualty Incidents , Multiple Trauma/surgery , Organizational Case Studies
4.
Neuroimage Clin ; 2: 402-13, 2013.
Article in English | MEDLINE | ID: mdl-24179794

ABSTRACT

Magnetic resonance imaging (MRI) can be used to detect lesions in the brains of multiple sclerosis (MS) patients and is essential for diagnosing the disease and monitoring its progression. In practice, lesion load is often quantified by either manual or semi-automated segmentation of MRI, which is time-consuming, costly, and associated with large inter- and intra-observer variability. We propose OASIS is Automated Statistical Inference for Segmentation (OASIS), an automated statistical method for segmenting MS lesions in MRI studies. We use logistic regression models incorporating multiple MRI modalities to estimate voxel-level probabilities of lesion presence. Intensity-normalized T1-weighted, T2-weighted, fluid-attenuated inversion recovery and proton density volumes from 131 MRI studies (98 MS subjects, 33 healthy subjects) with manual lesion segmentations were used to train and validate our model. Within this set, OASIS detected lesions with a partial area under the receiver operating characteristic curve for clinically relevant false positive rates of 1% and below of 0.59% (95% CI; [0.50%, 0.67%]) at the voxel level. An experienced MS neuroradiologist compared these segmentations to those produced by LesionTOADS, an image segmentation software that provides segmentation of both lesions and normal brain structures. For lesions, OASIS out-performed LesionTOADS in 74% (95% CI: [65%, 82%]) of cases for the 98 MS subjects. To further validate the method, we applied OASIS to 169 MRI studies acquired at a separate center. The neuroradiologist again compared the OASIS segmentations to those from LesionTOADS. For lesions, OASIS ranked higher than LesionTOADS in 77% (95% CI: [71%, 83%]) of cases. For a randomly selected subset of 50 of these studies, one additional radiologist and one neurologist also scored the images. Within this set, the neuroradiologist ranked OASIS higher than LesionTOADS in 76% (95% CI: [64%, 88%]) of cases, the neurologist 66% (95% CI: [52%, 78%]) and the radiologist 52% (95% CI: [38%, 66%]). OASIS obtains the estimated probability for each voxel to be part of a lesion by weighting each imaging modality with coefficient weights. These coefficients are explicit, obtained using standard model fitting techniques, and can be reused in other imaging studies. This fully automated method allows sensitive and specific detection of lesion presence and may be rapidly applied to large collections of images.

5.
Arch Surg ; 147(12): 1114-22, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23248013

ABSTRACT

OBJECTIVES: To determine the safety, clinical yield, and cost of computed tomography angiography (CTA) use in the workup of potential renal transplant recipients. DESIGN: Single-site, retrospective review of medical, surgical, and radiologic records. SETTING: Large university tertiary care center. PATIENTS: Potential recipients of transplants from living donors. INTERVENTIONS: Computed tomography with and without 100 mL of iodixanol intravenous contrast enhancement as part of the preoperative workup. MAIN OUTCOME MEASURES: Mean pre- and post-CTA estimated glomerular filtration rate and number of patients requiring emergent dialysis after CTA, number of patients who had their treatment changed by CTA findings, patient predictors of significant CTAs, and cost per significant CTA. RESULTS: From July 20, 2006, through December 10, 2010, a total of 179 transplant candidates underwent CTA. Forty-two patients were predialysis at the time of CTA. Mean (SD) serum creatinine levels in this group were unchanged after CTA (5.06 [2.13] mg/dL vs 5.00 [2.28] mg/dL [to convert to micromoles per liter, multiply by 88.4], P = .49), and no patients required subsequent emergent dialysis. Forty-one patients (22.9%) had their treatment changed by CTA findings. Multivariate logistic regression analysis revealed 3 patient history and physical criteria that predicted significant CTA findings: chronic infection (odds ratio, 10.91; 95% CI, 2.72-43.69; P < .001), patient weight less than 69 kg (3.11; 1.49-6.51; P < .001), and ventral torso surgical scarring (4.13; 1.57-10.84; P < .001). Diagnostic cost per significant CTA study was $2660, with an estimated reduced cost of $1480 per significant study with screening using 1 of the 3 predictors. CONCLUSION: Diagnostic CTA is a safe and cost-effective procedure for both operative planning and screening for potentially prohibitive abdominal disease.


Subject(s)
Angiography/economics , Kidney Transplantation , Perioperative Care/economics , Renal Insufficiency/diagnostic imaging , Renal Insufficiency/therapy , Tomography, X-Ray Computed/economics , Adult , Aged , Angiography/adverse effects , Contrast Media , Cost-Benefit Analysis , Female , Humans , Male , Middle Aged , Patient Selection , Perioperative Care/adverse effects , Predictive Value of Tests , Renal Insufficiency/complications , Retrospective Studies , Risk Factors , Tomography, X-Ray Computed/adverse effects , Triiodobenzoic Acids
SELECTION OF CITATIONS
SEARCH DETAIL
...