Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 53
Filter
1.
Article in English | MEDLINE | ID: mdl-38750671

ABSTRACT

BACKGROUND: Management of atrial fibrillation (AF) in very severe obese patients is challenging. Cryoballoon ablation (CBA) represents an effective rhythm control strategy. However, data in this patient group were limited. METHODS: Highly symptomatic AF patients with body mass index (BMI) ≥ 40 kg/m2 who had failed antiarrhythmic drug therapy and electrocardioversion and failure to achieve targeted body-weight-reduction underwent CBA. RESULTS: Data of 72 very severe obese AF patients (Group A) and 129 AF patients with normal BMI (Group B, BMI < 25 kg/m2) were consecutively collected. Group A had significantly younger age (60.6 ± 10.4 vs. 69.2 ± 11.2 years), higher BMI (44.3 ± 4.3 vs. 22.5 ± 1.6 kg/m2). Procedural pulmonary vein isolation (PVI) was successful in all patients (2 touch-up ablation in Group A). Compared to Group B, Group A had similar procedural (61.3 ± 22.6 vs. 57.5 ± 19 min), similar fluoroscopy time (10.1 ± 5.5 vs. 9.2 ± 4.8 min) but significantly higher radiation dose (2852 ± 2095 vs. 884 ± 732 µGym2). We observed similar rates of real-time-isolation (78.6% vs. 78.5%), single-shot-isolation (86.5% vs. 88.8%), but significantly longer time-to-sustained-isolation (53.5 ± 33 vs. 43.2 ± 25 s). There was significantly higher rate of puncture-site-complication (6.9% vs. 1.6%) in Group A. One-year clinical success in paroxysmal AF was (Group A: 69.4% vs. Group B: 80.2%; p < .001), in persistent AF was (Group A: 58.1% vs. Group B: 62.8%; p = .889). In Re-Do procedures Group A had a numerically lower PVI durability (75.0% vs. 83.6%, p = .089). CONCLUSION: For very severe obese AF patients, CBA appears feasible, leads to relatively good clinical outcome.

3.
Europace ; 26(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38363995

ABSTRACT

Ventricular tachycardia (VT), and its occurrence, is still one of the main reasons for sudden cardiac death and, therefore, for increased mortality and morbidity foremost in patients with structural heart [Kahle A-K, Jungen C, Alken F-A, Scherschel K, Willems S, Pürerfellner H et al. Management of ventricular tachycardia in patients with ischaemic cardiomyopathy: contemporary armamentarium. Europace 2022;24:538-51]. Catheter ablation has become a safe and effective treatment option in patients with recurrent VT [Cronin EM, Bogun FM, Maury P, Peichl P, Chen M, Namboodiri N et al. 2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias. Heart Rhythm 2020;17:e2-154]. Previous and current guidelines provide guidance on indication for VT ablation and risk assessment and evaluation of underlying disease. However, no uniform recommendation is provided regarding procedural strategies, timing of ablation, and centre setting. Therefore, these specifics seem to differ largely, and recent data are sparse. This physician-based European Heart Rhythm Association survey aims to deliver insights on not only infrastructural settings but also procedural specifics, applied technologies, ablation strategies, and procedural endpoints. Therefore, these findings might deliver a real-world scenario of VT management and potentially are of guidance for other centres.


Subject(s)
Catheter Ablation , Myocardial Ischemia , Tachycardia, Ventricular , Humans , Workflow , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Arrhythmias, Cardiac/surgery , Treatment Outcome , Catheter Ablation/methods
4.
Europace ; 26(1)2023 12 28.
Article in English | MEDLINE | ID: mdl-38091971

ABSTRACT

Limited data are available regarding venous thromboembolism (VTE), specifically deep vein thrombosis (DVT) and pulmonary embolism (PE), following right-sided ablations and electrophysiological (EP) studies. Compared to left-sided procedures, no guidelines on antithrombotic management strategies for the prevention of DVT and PE are available. The main purpose of the present European Heart Rhythm Association (EHRA) survey is to report the current management of right-sided EP procedures, focusing on anticoagulation and prevention of VTE. An online survey was conducted using the EHRA infrastructure. A total of 244 participants answered a 19-items questionnaire on the periprocedural management of EP studies and right-sided catheter ablations. The right femoral vein is the most common access for EP studies and right-sided procedures. An ultrasound-guided approach is employed by more than 2/3 of respondents. Intravenous heparin is not commonly given by the majority of participants. About 1/3 of participants (34%) routinely prescribe VTE prophylaxis during (mostly aspirin and low molecular weight heparin) and 1/4 of respondents (25%) commonly prescribe VTE prophylaxis after discharge (mostly aspirin). Of note, respectively 13% and 9% of participants observed at least one DVT and one PE related to right-sided ablation or EP study within the last year in their center. The present survey shows that only a minority of operators routinely gives intraprocedural intravenous heparin and prescribes VTE prophylaxis after right-sided EP procedures. Compared to left-sided procedures like atrial fibrillation (AF) ablation, there are no consistent systematic antithrombotic management strategies.


Subject(s)
Pulmonary Embolism , Venous Thromboembolism , Humans , Venous Thromboembolism/epidemiology , Venous Thromboembolism/prevention & control , Anticoagulants/therapeutic use , Fibrinolytic Agents/therapeutic use , Heparin , Pulmonary Embolism/prevention & control , Pulmonary Embolism/drug therapy , Aspirin , Surveys and Questionnaires
5.
JACC Cardiovasc Interv ; 16(22): 2722-2732, 2023 Nov 27.
Article in English | MEDLINE | ID: mdl-38030358

ABSTRACT

BACKGROUND: Scarce data exist on the evolution of device-related thrombus (DRT) after left atrial appendage closure (LAAC). OBJECTIVES: This study sought to assess the incidence, predictors, and clinical impact of persistent and recurrent DRT in LAAC recipients. METHODS: Data were obtained from an international multicenter registry including 237 patients diagnosed with DRT after LAAC. Of these, 214 patients with a subsequent imaging examination after the initial diagnosis of DRT were included. Unfavorable evolution of DRT was defined as either persisting or recurrent DRT. RESULTS: DRT resolved in 153 (71.5%) cases and persisted in 61 (28.5%) cases. Larger DRT size (OR per 1-mm increase: 1.08; 95% CI: 1.02-1.15; P = 0.009) and female (OR: 2.44; 95% CI: 1.12-5.26; P = 0.02) were independently associated with persistent DRT. After DRT resolution, 82 (53.6%) of 153 patients had repeated device imaging, with 14 (17.1%) cases diagnosed with recurrent DRT. Overall, 75 (35.0%) patients had unfavorable evolution of DRT, and the sole predictor was average thrombus size at initial diagnosis (OR per 1-mm increase: 1.09; 95% CI: 1.03-1.16; P = 0.003), with an optimal cutoff size of 7 mm (OR: 2.51; 95% CI: 1.39-4.52; P = 0.002). Unfavorable evolution of DRT was associated with a higher rate of thromboembolic events compared with resolved DRT (26.7% vs 15.1%; HR: 2.13; 95% CI: 1.15-3.94; P = 0.02). CONCLUSIONS: About one-third of DRT events had an unfavorable evolution (either persisting or recurring), with a larger initial thrombus size (particularly >7 mm) portending an increased risk. Unfavorable evolution of DRT was associated with a 2-fold higher risk of thromboembolic events compared with resolved DRT.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Thromboembolism , Thrombosis , Humans , Female , Incidence , Atrial Appendage/diagnostic imaging , Treatment Outcome , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Atrial Fibrillation/complications , Thromboembolism/diagnostic imaging , Thromboembolism/epidemiology , Thromboembolism/etiology , Thrombosis/diagnostic imaging , Thrombosis/epidemiology , Thrombosis/etiology , Stroke/etiology
7.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37498147

ABSTRACT

AIMS: Electrophysiology (EP) is a growing field in cardiology, with an increasing involvement of young people. Nevertheless, concerns about radiation exposure and its impact on reproduction and pregnancy may discourage the choice of an EP career. The study is aimed at investigating the level of awareness and main sources of concern about the effects of radiation on reproductive potential and pregnancy, exploring the safety measures adopted in different EP labs, and verifying the adherence to the current guidelines. METHODS AND RESULTS: An online survey was conducted using the European Heart Rhythm Association (EHRA) infrastructure from April to June 2022. A total of 252 EP personnel (42% women) participated, from 50 countries and different professional roles. Most participants expressed concerns regarding the effects of radiation on reproductive capacity (67.1%) and offspring diseases (68.2%). Only 37.9% of participants were aware of the EHRA 2017 consensus document about occupational radiation exposure. Most participants (80.9%) considered that occupational radiation during pregnancy is not safe. EP female staff were not allowed to work in the EP lab during pregnancy in 48.1% of cases. Zero-fluoroscopy was the preferred choice to continue working in the EP lab during pregnancy. CONCLUSION: EP staff, including both men and women, have concerns about the effects of radiation on reproductive capacity. Despite the recommendations issued by international bodies, implementation of the policies regarding pregnancy and occupational radiation exposure is heterogeneous. Zero-fluoroscopy is the preferred approach to ensure safety during pregnancy in the EP lab.


Subject(s)
Occupational Exposure , Radiation Exposure , Radiation Injuries , Male , Pregnancy , Female , Humans , Adolescent , Radiation Exposure/adverse effects , Radiation Exposure/prevention & control , Surveys and Questionnaires , Reproduction , Cardiac Electrophysiology , Occupational Exposure/adverse effects , Occupational Exposure/prevention & control , Radiation Dosage
8.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-37140046

ABSTRACT

AIMS: The aim of this study was to identify potential regional disparities in characteristics of implantable cardioverter-defibrillator (ICD) recipients, patient perceptions and perspectives after implantation and level of information provided to patients. METHODS AND RESULTS: The prospective, multicentre, and multinational European Heart Rhythm Association patient Survey 'Living with an ICD' included patients already implanted with an ICD (median ICD dwell time - 5 years, interquartile range 2-10). An online questionnaire was filled-in by patients invited from 10 European countries. A total of 1809 patients (the majority in their 40s to 70s, 65.5% men) were enrolled, with 877 (48.5%) from Western Europe (group 1), followed by 563 from Central/Eastern Europe (group 2, 31.1%), and 369 from Southern Europe (group 3, 20.4%). A total of 52.9% of Central/Eastern Europe patients reported increased satisfaction after ICD placement compared with 46.6% from Western and 33.1% from Southern Europe (1 vs. 2 P = 0.047, 1 vs. 3 P < 0.001, 2 vs. 3 P < 0.001). About 79.2% of Central/Eastern and 76.0% of Southern Europe patients felt optimally informed at the time of device implantation compared with just 64.6% from Western Europe (1 vs. 2 P < 0.001, 1 vs. 3 P < 0.001, 2 vs. 3 P = ns). CONCLUSIONS: While physicians in Southern Europe should address the patients' concerns about the impact of the ICD on quality of life, physicians from Western Europe should focus on improving the quality of information provided to their prospective ICD patients. Novel strategies to address regional differences in patients' quality of life and provision of information are warranted.


Subject(s)
Defibrillators, Implantable , Male , Humans , Female , Quality of Life , Prospective Studies , Surveys and Questionnaires , Europe/epidemiology
9.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-37116126

ABSTRACT

AIMS: A novel irrigated radiofrequency (RF) balloon (RFB) for pulmonary vein (PV) isolation (PVI) was released in selected centres. We pooled the procedural data on efficacy and safety of RFB-PVI from two high volume German centres. METHODS AND RESULTS: Consecutive patients with RFB procedures were enrolled. A 3D electroanatomical left atrial map guided the RFB navigation. Every RF delivery lasted 60 s, and duration was automatically reduced to 20 s for electrodes facing the posterior wall. Procedural data and post-procedural endoscopy data (<48 h) were analysed. Data from 140 patients were collected (57% male, 67 ± 11 years, 57% paroxysmal atrial fibrillation). There were 547 PVs identified, and 99.1% could be isolated using solely the RFB. Single-shot PVI was recorded in 330/547 (60%) PVs. Median time to isolation during the first application was 10 s (IQR 8-13). A total of 2.1 ± 1.8 applications per PV were delivered, with the left superior PV requiring more application compared to other PVs. Median procedure and fluoroscopy time were 77 min (61-99) and 13 min (10-17), respectively. Major safety events were recorded only in the first 25 cases at each centre and included 1/140(0.7%) cardiac tamponade, 1/140(0.7%) phrenic nerve palsy, and 2/140 strokes (1.4%). An oesophageal temperature rise was recorded in 81/547 (15%) PVs, and endoscopy detected oesophageal lesions in 7/85 (8%) patients undergoing endoscopy. CONCLUSION: The RFB showed a high efficacy allowing for fast PVI procedures, and 60% of PVs could be isolated at the first application. Most safety events were recorded during the learning phase. An oesophageal temperature monitoring is suggested: oesophageal lesions were detected in 8% of patients.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Male , Female , Treatment Outcome , Catheter Ablation/adverse effects , Catheter Ablation/methods , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Heart Atria , Pulmonary Veins/surgery
10.
Article in English | MEDLINE | ID: mdl-36981953

ABSTRACT

BACKGROUND: The aim of this study was to compare differences between Polish ICD recipients and ICD recipients from other European countries in terms of quality of life, information provision before ICD implantation, and end-of-life issues. METHODS: This is a sub-analysis of the "Living with an ICD" patient survey (25-item questionnaire) organized by the European Heart Rhythm Association between 12 April 2021 and 5 July 2021 in ten European countries. RESULTS: There were 410 (22.7%) patients from Poland and 1399 (77.3%) from other European countries. A total of 51.0% of Polish patients reported improvement in their quality of life compared with 44.3% in other countries (p = 0.041). Remote monitoring was three times more often utilized in other countries than in Poland (66.8% vs. 21.0%, p < 0.001). While 78.1% of Poles felt well informed before ICD implantation compared with 69.6% of subjects from other countries (p = 0.001), they were less familiar with the ICD deactivation process than others (38.9% vs. 52.5%, p < 0.001). CONCLUSIONS: Despite the less frequent use of remote monitoring and gaps in end-of-life issues, Polish ICD recipients reported more favorable quality of life and a higher level of information received before device placement than patients in other European countries.


Subject(s)
Defibrillators, Implantable , Humans , Poland , Quality of Life , Europe , Surveys and Questionnaires
11.
Europace ; 25(3): 1144-1151, 2023 03 30.
Article in English | MEDLINE | ID: mdl-36691111

ABSTRACT

AIMS: Information provided to patients prior to implantable cardioverter-defibrillator (ICD) insertion and their participation in the decision-making process are crucial for understanding ICD function and accepting this lifelong therapy. The aim of this study is to evaluate the extent to which different aspects related to ICD and quality of life were transmitted to patients prior to ICD implantation. METHODS AND RESULTS: Prospective, multicenter European study with an online questionnaire initiated by the European Heart Rhythm Association. The questionnaire was filled-in directly and personally by the ICD patients who were invited to participate. A total of 1809 patients (majority in their 40s-70s, with 624 women, 34.5%) from 10 European countries participated in the study. The median time from first ICD implantation was 5 years (interquartile range 2-10). Overall, 1155 patients (71.5%) felt optimally informed at the time of device implantation, however many respondents received no information about ICD-related complications (n = 801, 49.6%), driving restrictions (n = 718, 44.5%), and possibility of end-of-life ICD deactivation (n = 408, 25.4%). Of note, women were less frequently involved in the decision-making process than men (47.3% vs. 55.9%, P = 0.003) and reported to be less often optimally informed before ICD implantation than men (61.2% vs. 76.8%, P < 0.001). More women mentioned the desire to have learned more about ICD therapy and the benefit/risk balance (45.4% vs. 33.7% of men; P < 0.001). CONCLUSIONS: This patient-based evaluation provides alarming findings on the lack of information provided to patients prior ICD implantation, particularly for women.


Subject(s)
Defibrillators, Implantable , Quality of Life , Male , Humans , Female , Prospective Studies , Electric Countershock/adverse effects , Defibrillators, Implantable/adverse effects , Europe , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control
12.
Europace ; 25(2): 676-681, 2023 02 16.
Article in English | MEDLINE | ID: mdl-36372986

ABSTRACT

Atrial fibrillation (AF) is a major challenge for the healthcare field. Pulmonary vein isolation is the most effective treatment for the maintenance of sinus rhythm. However, clinical endpoints for the procedure vary significantly among studies. There is no consensus on the definition of recurrence and no clear roadmap on how to deal with recurrences after a failed ablation. The purpose of this study was to perform a survey in order to show how clinicians currently approach this knowledge gap. An online survey, supported by the European Heart Rhythm Association (EHRA) Scientific Initiatives Committee, was conducted between 1 April 2022 and 8 May 2022. An anonymous questionnaire was disseminated via social media and EHRA newsletters, for clinicians to complete. This consisted of 18 multiple-choice questions regarding rhythm monitoring, definitions of a successful ablation, clinical practices after a failed AF ablation, and the continuance of anticoagulation. A total of 107 replies were collected across Europe. Most respondents (82%) perform routine monitoring for AF recurrences after ablation, with 51% of them preferring a long-term monitoring strategy. Cost was reported to have an impact on the choice of monitoring strategy. Self-screening was recommended by most (71%) of the respondents. The combination of absence of symptoms and recorded AF was the definition of success for most (83%) of the respondents. Cessation of anticoagulation after ablation was an option mostly for patients with paroxysmal AF and a low CHA2DS2-VASc score. The majority of physicians perform routine monitoring after AF ablation. For most physicians, the combination of the absence of symptoms and electrocardiographic endpoints defines a successful result after AF ablation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/drug therapy , Treatment Outcome , Europe/epidemiology , Anticoagulants/adverse effects , Surveys and Questionnaires , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
14.
Europace ; 25(2): 374-381, 2023 02 16.
Article in English | MEDLINE | ID: mdl-36414239

ABSTRACT

AIMS: Cryoballoon (CB)-based pulmonary vein isolation (PVI) is an effective treatment for atrial fibrillation (AF). The most frequent complication during CB-based PVI is right-sided phrenic nerve injury (PNI) which is leading to premature abortion of the freeze cycle. Here, we analysed reconnection rates after CB-based PVI and PNI in a large-scale population during repeat procedures. METHODS AND RESULTS: In the YETI registry, a total of 17 356 patients underwent CB-based PVI in 33 centres, and 731 (4.2%) patients experienced PNI. A total of 111/731 (15.2%) patients received a repeat procedure for treatment of recurrent AF. In 94/111 (84.7%) patients data on repeat procedures were available. A total of 89/94 (94.7%) index pulmonary veins (PVs) have been isolated during the initial PVI. During repeat procedures, 22 (24.7%) of initially isolated index PVs showed reconnection. The use of a double stop technique did non influence the PV reconnection rate (P = 0.464). The time to PNI was 140.5 ± 45.1 s in patients with persistent PVI and 133.5 ± 53.8 s in patients with reconnection (P = 0.559). No differences were noted between the two populations in terms of CB temperature at the time of PNI (P = 0.362). The only parameter associated with isolation durability was CB temperature after 30 s of freezing. The PV reconnection did not influence the time to AF recurrence. CONCLUSION: In patients with cryoballon application abortion due to PNI, a high rate of persistent PVI rate was found at repeat procedures. Our data may help to identify the optimal dosing protocol in CB-based PVI procedures. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT03645577?term=YETI&cntry=DE&draw=2&rank=1 ClinicalTrials.gov Identifier: NCT03645577.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Catheter Ablation/adverse effects , Cryosurgery/adverse effects , Cryosurgery/methods , Phrenic Nerve , Pulmonary Veins/surgery , Recurrence , Time Factors , Treatment Outcome
15.
Pacing Clin Electrophysiol ; 46(5): 414-418, 2023 05.
Article in English | MEDLINE | ID: mdl-36424836

ABSTRACT

Pulsed field ablation (PFA) using high-voltage electrical energy is a novel and powerful ablation modality. However, PFA as a first-line rhythm control in atrial fibrillation (AF) has been rarely described; whether PFA interacts with the pacemaker (PM) has been seldom reported. We reported PFA of AF in a patient with PM who needed effective rhythm control. Pulmonary vein isolation (PVI) was successfully performed without complication, and the procedure was extremely fast (skin-to-skin 25 min.) with short fluoroscopic time (3.9 min). PFA had no influence on the PM function. Six months' follow-up showed good clinical outcome and significantly decreased AF burden.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Treatment Outcome , Catheter Ablation/methods , Pulmonary Veins/surgery , Recurrence
17.
J Clin Med ; 11(22)2022 Nov 21.
Article in English | MEDLINE | ID: mdl-36431348

ABSTRACT

Catheter Ablation (CA) is an effective therapeutic option in treating atrial fibrillation (AF). Importantly, recent data show that CA as a rhythm control strategy not only significantly reduces AF burden, but also substantially improves clinical hard endpoints. Since AF is a progressive disease, the time of Diagnosis-to-Intervention appears crucial. Recent evidence shows that earlier rhythm control is associated with a lower risk of adverse cardiovascular outcomes in patients with early AF. Particularly, CA as an initial first line rhythm control strategy is associated with significant reduction of arrhythmia recurrence and rehospitalization in patients with paroxysmal AF. CA is shown to significantly lower the risk of progression from paroxysmal AF to persistent AF. When treating persistent AF, the overall clinical success after ablation remains unsatisfactory, however the ablation outcome in patients with "early" persistent AF appears better than those with "late" persistent AF. "Adjunctive" ablation on top of pulmonary vein isolation (PVI), e.g., ablation of atrial low voltage area, left atrial posterior wall, vein of Marshall, left atrial appendage, etc., may further reduce arrhythmia recurrence in selected patient group. New ablation concepts or new ablation technologies have been developing to optimize therapeutic effects or safety profile and may ultimately improve the clinical outcome.

18.
Europace ; 24(10): 1684-1690, 2022 10 13.
Article in English | MEDLINE | ID: mdl-35942585

ABSTRACT

The use of a blanking period (BP) after an atrial fibrillation (AF) ablation procedure is a common practice, but recent data questions the benign nature of early recurrences of atrial tachyarrhythmias (ERATs). A physician-based survey was carried out by the European Heart Rhythm Association (EHRA) to investigate the current definition and applicability of BP and ERAT management. An online questionnaire was sent to clinical and interventional electrophysiologists. A total of 436 respondents (88% interventional electrophysiologists) reported observing ERATs in 25% (interquartile range 15-35) of patients, less commonly in paroxysmal AF (PAF) compared with persistent AF (persAF). The median reported duration of BP used by respondents was 90 days, with 22% preferring a shorter BP duration for PAF patients compared with persAF. Half of the patients with ERATs are expected to also experience late recurrences (LR). Isolated episodes of ERATs are treated conservatively by 99% of the respondents, but repeat ablation during the BP is preferred by 20% of electrophysiologists for multiple ERATs and by 16% in patients with organized atrial tachyarrhythmias. In conclusion, ERATs are commonly observed after AF ablation, particularly in persAF patients, and are perceived as predictors of LR by half of the respondents. A general adherence to a 90-day BP duration was observed. During this time period, ERAT is mainly treated conservatively, but repeat ablation during the BP is occasionally offered to patients with multiple ERATs and those with organized atrial tachyarrhythmias.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cryosurgery/methods , Humans , Pulmonary Veins/surgery , Recurrence , Surveys and Questionnaires , Treatment Outcome
19.
Europace ; 24(8): 1300-1306, 2022 09 01.
Article in English | MEDLINE | ID: mdl-35943366

ABSTRACT

The healthcare sector accounts for nearly 5% of global greenhouse gas emissions (GHG) and is a significant contributor to complex waste. Reducing the environmental impact of technology-heavy medical fields such as cardiac electrophysiology (EP) is a priority. The aim of this survey was to investigate the practice and expectations in European centres on EP catheters environmental sustainability. A 24-item online questionnaire on EP catheters sustainability was disseminated by the EHRA Scientific Initiatives Committee in collaboration with the Lyric Institute. A total of 278 physicians from 42 centres were polled; 62% were motivated to reduce the environmental impact of EP procedures. It was reported that 50% of mapping catheters and 53% of ablation catheters are usually discarded to medical waste, and only 20% and 14% of mapping and ablation catheters re-used. Yet, re-use of catheters was the most commonly cited potential sustainability solution (60% and 57% of physicians for mapping and ablation catheters, respectively). The majority of 69% currently discarded packaging. Reduced (42%) and reusable (39%) packaging also featured prominently as potential sustainable solutions. Lack of engagement from host institutions was the most commonly cited barrier to sustainable practices (59%). Complexity of the process and challenges to behavioral change were other commonly cited barriers (48% and 47%, respectively). The most commonly cited solutions towards more sustainable practices were regulatory changes (31%), education (19%), and product after-use recommendations (19%). In conclusion, EP physicians demonstrate high motivation towards sustainable practices. However, significant engagement and behavioural change, at local institution, regulatory and industry level is required before sustainable practices can be embedded into routine care.


Subject(s)
Motivation , Physicians , Humans , Surveys and Questionnaires , Cardiac Electrophysiology , Environment
20.
Europace ; 24(Suppl 2): ii8-ii13, 2022 06 06.
Article in English | MEDLINE | ID: mdl-35661870

ABSTRACT

Ablation of atrial fibrillation (AF) is an established treatment option for symptomatic patients. The cornerstone of all ablation strategies is electrical isolation of the pulmonary veins (PVs). Ablation strategies going beyond PV isolation (PVI) might be considered in the setting of recurrent AF despite durably isolated PVs. The lack of persistent PVI, however, limits the opportunities to perceive the real impact of this endpoint on AF suppression and to fully understand the benefit of extended ablation strategies going beyond. To overcome this limitation, novel and innovative ablation systems have been developed to facilitate acute PVI and to increase its durability. These systems include balloon-based ablation devices incorporating different energy sources such as cryo energy, laser, or radiofrequency current, but also new energy sources such as pulsed field ablation as a non-thermal energy source. These technologies could advance catheter ablation of AF to an early stage of the disease and to the primary treatment tool. The current manuscript focuses on the past, the present, and the future value of PVI as the cornerstone for interventional treatment of AF and on how to achieve durable PVI during the first procedure and to further improve the clinical success rates of AF ablation. It also analyses extended ablation strategies going beyond PVI and their impact.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cryosurgery/adverse effects , Humans , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...