Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Publication year range
1.
ScientificWorldJournal ; 2014: 387210, 2014.
Article in English | MEDLINE | ID: mdl-24955398

ABSTRACT

The influence of seismic loading on segment opening of a shield tunnel was explored using the dynamic finite element method to analyze the distribution of segment opening under multidirectional seismic loading, combined with a typical engineering installation. The calculation of segment opening was deduced from equivalent continuous theory and segment opening was obtained through calculations. The results show that the scope of influence of the foundation excavation on segment opening is mainly resigned to within 5 segment rings next to the diaphragm wall and 4 joints nearest the working well when the tunnel is first excavated followed by the working well in the excavation order. The effect of seismic loading on segment opening is significant, and the minimum increase of the maximal segment opening owing to seismic loading is 16%, while that of the average opening is 27%. Segment opening under bidirectional coupled seismic loading is significantly greater than that under one-dimensional seismic loading. On the basis of the numerical calculations, the seismic acceleration and segment opening caused by seismic action were normalized, and a new calculation method was proposed for predicting the maximal segment opening of a shield tunnel at different depths under conditions of seismic loading.

2.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-736903

ABSTRACT

Objective:To optimize the injection protocol of contrast medium for contrast-enhanced MRA (CEMRA) of pulmonary artery and to evaluate the diagnostic value of CEMRA and pulmonary perfusion imaging (PPI) in an experimental model of acute pulmonary embolism. Methods:CEMRA and PPI were performed in 6 normal pigs with different doses of gadolinium contrast agent (5ml, 10ml, 15ml, 20ml and 25ml) at an injection rate of 3ml/s, and 3 pulmonary embolism models were injected with 20 ml contrast agent at 3 ml/s. DSA was also performed for comparison. Results:The signal intensities and the signal to noise ratios of the pulmonary arteries kept increasing with the dose increase of the contrast agent, but the best angio-pulmonary contrast dose was 10-15ml (0.25-0.375mmol/kg), while the optimal dose for PPI was 15-20ml (0.375-0.5mmol/kg). Although CEMRA demonstrated less obstructed pulmonary arteries than DSA (5/10 vs 8/10)did, it detected all obstructions when combined with PPI. The pulmonary infarction zones showed wedge-shaped perfusion defects on the PPI images, with the signal intensities lower than those of the normal areas (137.86±45.32 vs 330.14±46.52, P<0.001). Conclusion:It is suggested that the optimal dose of the contrast agent is 0.25mmol/kg to 0.375mmol/kg for CEMRA, and 0.375mmol/kg to 0.5mmol/kg for lung perfusion. CEMRA combined with PPI may be better than DSA in demonstrating pulmonary embolism.

3.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-735435

ABSTRACT

Objective:To optimize the injection protocol of contrast medium for contrast-enhanced MRA (CEMRA) of pulmonary artery and to evaluate the diagnostic value of CEMRA and pulmonary perfusion imaging (PPI) in an experimental model of acute pulmonary embolism. Methods:CEMRA and PPI were performed in 6 normal pigs with different doses of gadolinium contrast agent (5ml, 10ml, 15ml, 20ml and 25ml) at an injection rate of 3ml/s, and 3 pulmonary embolism models were injected with 20 ml contrast agent at 3 ml/s. DSA was also performed for comparison. Results:The signal intensities and the signal to noise ratios of the pulmonary arteries kept increasing with the dose increase of the contrast agent, but the best angio-pulmonary contrast dose was 10-15ml (0.25-0.375mmol/kg), while the optimal dose for PPI was 15-20ml (0.375-0.5mmol/kg). Although CEMRA demonstrated less obstructed pulmonary arteries than DSA (5/10 vs 8/10)did, it detected all obstructions when combined with PPI. The pulmonary infarction zones showed wedge-shaped perfusion defects on the PPI images, with the signal intensities lower than those of the normal areas (137.86±45.32 vs 330.14±46.52, P<0.001). Conclusion:It is suggested that the optimal dose of the contrast agent is 0.25mmol/kg to 0.375mmol/kg for CEMRA, and 0.375mmol/kg to 0.5mmol/kg for lung perfusion. CEMRA combined with PPI may be better than DSA in demonstrating pulmonary embolism.

4.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-679671

ABSTRACT

Objective To assess the clinical application of contrast-enhanced MR angiography using three-dimensional(3D)time-resolved imaging of contrast kinetics(CE-MRA 3D-TRICKS).Methods TRICKS is a high temporal resolution(2—6s)MR angiographic technique using a short TR(2.8— 4.0 ms)and TE(0.9—1.3 ms),partial echo sampling and the central part of the k-space being updated more frequently than the peripheral part of the k-space.Pre-contrast mask 3D images are first acquired and 15--20 sequential 3D images following bolus injection of Gd-DTPA are then acquired.Results Thirty patients underwent contrast-enhanced MR angiography using TRICKS.Twelve vertebral arteries were well displayed on TRICKS.Seven of them showed normal,bilateral vertebral artery stenosis was shown in 1 case, and unilateral vertebral artery stenosis was shown in 4 wth aecompaning ipsilateral carotid artery bifurcation stenosis in one case.Bilateral renal artery showed normal in 4 cases,and the artery in transplanted kidney showed normal in one case and stenosis in another case.The cerebral artery showed normal in 2 cases, sagittal sinus thrombosis was detected in one case and intracranial arteriovenous malformation in one case. Pulmonary artery displayed normal in 3 cases,pulmonary artery thrombosis was seen in one case and pulmonary sequestration's abnormal feeding artery and draining vein was revealed in one case.The feeding artery in left lower limb fibrolipoma was showed in one case.The radial-ulnar artery artificial fistula stenosis was seen in one case,and left antebrachium hemangioma was showed in one case.Conclusion TRICKS can clearly delineate the whole body vascular system and can reveal any vascular abnormality.It is convenient and with high successful rate,which make it the first method of choice in displaying vascular abnormality.

SELECTION OF CITATIONS
SEARCH DETAIL
...