Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
J Cardiothorac Surg ; 18(1): 288, 2023 Oct 12.
Article in English | MEDLINE | ID: mdl-37828522

ABSTRACT

BACKGROUND: Tricuspid regurgitation(TR) following heart transplantation could adversely affect clinical outcomes. In an effort to reduce the incidence of TR, prophylactic donor heart tricuspid valve annuloplasty has been performed during heart transplantation in our institution. We assessed early and long-term outcomes. METHODS: Between August 2011 and August 2021, 349 patients who underwent prophylactic tricuspid valve annuloplasty were included. Tricuspid valve annuloplasty was performed using the DeVega annuloplasty technique. The clinical outcomes of the interests included complete atrioventricular block requiring pacemaker implantation, the occurrence of significant TR(defined as moderate or greater), and survival. Long-term survival was compared in patients with and without significant TR using the Kaplan-Meier method. The Cox proportional hazards regression with time-dependent covariate analysis was used to see if significant TR affected the long-term survival. RESULTS: There was one patient(0.3%) who required pacemaker implantation for complete atrioventricular block. No patients developed tricuspid valve stenosis that required intervention. Significant TR developed in 31 patients(8.9%) during the follow-up period. The survival rate of patients who developed significant TR was significantly lower than that of those who did not(log rank < 0.01). Significant TR was associated with the long-term mortality(HR2.92, 95%CI 1.47-5.82, p < 0.01). CONCLUSIONS: Prophylactic donor heart tricuspid valve annuloplasty has the potential to reduce the occurrence of significant TR and can be performed safely. The significant TR that developed in patients with prophylactic annuloplasty negatively affected survival and was an independent predictor of long-term mortality.


Subject(s)
Atrioventricular Block , Cardiac Valve Annuloplasty , Heart Transplantation , Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve/surgery , Heart Transplantation/adverse effects , Retrospective Studies , Tissue Donors , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/etiology , Cardiac Valve Annuloplasty/adverse effects , Heart Valve Prosthesis Implantation/methods , Treatment Outcome
2.
Article in English | MEDLINE | ID: mdl-37421402

ABSTRACT

OBJECTIVES: It remains unknown if the left atrial appendage closure (LAAC) at the time of left ventricular assist device (LVAD) surgery can reduce ischaemic cerebrovascular accidents. METHODS: Consecutive 310 patients who underwent LVAD surgery with HeartMate II or 3 between January 2012 and November 2021 were included in this study. The cohort was divided into 2 groups: patients with LAAC (group A) and without LAAC (group B). We compared the clinical outcomes including the incidence of cerebrovascular accident between 2 groups. RESULTS: Ninety-eight patients were included in group A, and 212 patients in group B. There were no significant differences between 2 groups in age, preoperative CHADS2 score and history of atrial fibrillation. In-hospital mortality did not differ significantly between the 2 groups (group A: 7.1%, group B: 12.3%, P = 0.16). Thirty-seven patients (11.9%) experienced ischaemic cerebrovascular accident (5 patients in group A and 32 patients in group B). The cumulative incidence from ischaemic cerebrovascular accidents in group A (5.3% at 12 months and 5.3% at 36 months) was significantly lower than that in group B (8.2% at 12 months and 16.8% at 36 months; P = 0.017). In a multivariable competing risk analysis, LAAC was associated with reducing ischaemic cerebrovascular accidents (hazard ratio 0.38, 95% confidence interval 0.15-0.97, P = 0.043). CONCLUSIONS: Concomitant LAAC in LVAD surgery can reduce ischaemic cerebrovascular accidents without increasing perioperative mortality and complications.

4.
Heart Vessels ; 37(12): 1995-2001, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35794489

ABSTRACT

OBJECTIVES: The purpose of this study is to investigate the early and late outcomes of axillary intra-aortic balloon pump (IABP) implantation as a bridge to heart transplantation, comparing the grafted technique with the percutaneous technique. METHODS: Between July 2009 and January 2020, 163 patients underwent an axillary IABP insertion as a bridge to heart transplantation. Among them, 97 patients underwent axillary IABP implantation through a graft sutured onto the axillary artery (Group A) and 66 patients underwent percutaneously (Group B). Propensity matching identified 53 matched pairs for analysis (C-statistics 0.741). The primary outcomes of interest included IABP-related complications, success rate of a bridge to transplantation, in-hospital mortality, and late survival. RESULTS: In the propensity-score matched cohort, there were no significant differences in the baseline characteristics between the two groups. The operation time was significantly longer in Group A than in Group B (141.5 ± 38.3 min vs 42.7 ± 19.3 min, p < 0.01). The complication rates including stroke, re-exploration for bleeding, and aortic event were not significantly different between Group A and B. However, Group A required more transfusion and re-exploration for bleeding. The success rate of a bridge to transplantation was similar between Group A (47/53, 88.7%) and Group B (47/53, 88.7%). There were no significant differences in in-hospital mortality and late survival between two groups. CONCLUSION: In the propensity score matching analysis, there were not any significant differences between the two groups in IABP-related complications, in-hospital mortality, and late survival. The percutaneous technique provided a shorter operation time and less requirement of transfusion and re-exploration for bleeding compared to the grafted technique. The percutaneous technique might be favorable when feasible.


Subject(s)
Heart Transplantation , Heart-Assist Devices , Humans , Propensity Score , Retrospective Studies , Intra-Aortic Balloon Pumping/adverse effects , Treatment Outcome
5.
ESC Heart Fail ; 9(4): 2484-2490, 2022 08.
Article in English | MEDLINE | ID: mdl-35460200

ABSTRACT

AIMS: Heart transplantation involves many factors such as donor selection, recipient management, multidisciplinary assessment, coordination with other organ teams, and transportation. Because of some unpredictable factors, heart transplantation can be conducted at any time of day. The purpose of this study is to investigate if outcomes differ between heart transplants taking place inside or outside of normal working hours. METHODS AND RESULTS: We reviewed patients who underwent heart transplantation at our institution from January 2010 to July 2020 (n = 329). Based on the documented start time of the recipient surgeries, the cohort was divided into two groups: working hours (Group A: 7:30 to 17:00; n = 92) and after hours (Group B: 17:00 to 7:30; n = 237). We compared these groups using propensity score matching analysis. After propensity score matching, 78 pairs of patients were successfully matched. We reviewed early and late clinical outcomes including survival. Long-term survival was compared using the Kaplan-Meier method. In the propensity-score matched patients, there were no significant differences in the baseline characteristics between two groups. In-hospital mortality was not significantly different between the two groups (Group A: 6.4% vs. Group B: 2.6%, P = 0.44). Ischaemic time and cross-clamp time did not differ between the groups. In terms of postoperative complications, there were no significant differences between two groups in stroke (6.4% vs. 3.9%, P = 0.72), primary graft dysfunction requiring extracorporeal membrane oxygenation (5.1% vs. 7.7%, P = 0.75), re-exploration for bleeding (9.0% vs. 12.8%, P = 0.44), and newly required haemodialysis (7.7% vs. 6.4%, P = 0.75). The survival rate in Group A (88.1% at 1 year, 81.3% at 3 years) was not significantly different from Group B (90.5% at 1 year, 82.3% at 3 years, log rank = 0.96). CONCLUSION: There was no significant difference in clinical outcomes between heart transplants taking place inside or outside of working hours. A high quality of care can be provided for heart transplant patients even during after hours.


Subject(s)
Heart Transplantation , Personnel Staffing and Scheduling , Cohort Studies , Extracorporeal Membrane Oxygenation , Heart Transplantation/methods , Humans , Postoperative Complications/epidemiology , Retrospective Studies
6.
Ann Vasc Surg ; 83: 42-52, 2022 Jul.
Article in English | MEDLINE | ID: mdl-34995740

ABSTRACT

OBJECTIVE: Axillary Intra-aortic balloon pump (IABP) has been increasingly utilized for hemodynamic support in heart failure patients. Vascular complications associated with axillary IABP such as dissection or rupture are relatively rare but not negligible that could negatively affect clinical outcomes. We summarized our experiences. METHODS: This is a retrospective study reviewing of all patients receiving an axillary IABP between June 2016 and November 2020. A total of 199 patients underwent percutaneous axillary IABP placement. 6 patients (6/199, 3.0%) were complicated with arterial/aortic dissection or rupture during the procedures or the course of treatment. We described their clinical presentations and outcomes. RESULTS: Vascular complications included acute type A aortic dissection in 2 patients, descending aortic rupture in 1 patient, abdominal aortic rupture along with type B aortic dissection in 1 patient, and the localized left subclavian artery dissection in 2 patient. 2 type A aortic dissection cases were surgically treated: 1 with emergent left ventricle assist device and ascending aorta replacement, the other with emergent left ventricle assist device. Emergent endovascular treatment was successfully performed in 2 aortic rupture cases. The left subclavian artery dissection cases were managed medically. The postoperative/treatment course was uneventful in all patients. CONCLUSION: Percutaneous axillary IABP therapy can cause significant vascular complications. Early diagnosis and prompt treatment would be the key to improve the clinical outcomesv.


Subject(s)
Aortic Dissection , Aortic Rupture , Heart-Assist Devices , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Aortic Rupture/diagnostic imaging , Aortic Rupture/etiology , Aortic Rupture/surgery , Heart-Assist Devices/adverse effects , Humans , Retrospective Studies , Treatment Outcome
7.
Heart Vessels ; 37(4): 647-653, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34585275

ABSTRACT

We sought to assess the impact of the aortic root geometry on developing de novo aortic insufficiency (AI) in patients undergoing left ventricular assist device (LVAD). In total, 114 patients underwent LVAD implantation between February 2016 and January 2020 were included in this study (HeartMate3 N = 68, HeartWare N = 46). Significant aortic insufficiency was defined as mild-to-moderate or greater in echocardiography. The cohort was divided into two groups; those who developed significant AI (Group AI: n = 13) and did not (Group non-AI: n = 101). The primary outcomes of interest included late survival and predictors for significant AI. The patients in Group AI were older than Group non-AI (62.6 ± 11.9 vs 51.3 ± 14.0 years, p < 0.01). The diameter of proximal ascending aorta in Group AI was larger than Group non-AI (31.0 ± 5.0 vs 27.4 ± 4.3 mm, p < 0.01). Aortic valve remained closed in 53.8% in Group AI and 36.6% in Group non-AI (p = 0.24). The late survival was not significantly different between the groups (67.1% vs 76.0% at 3 years, log rank = 0.97). The Cox hazard model showed that larger proximal ascending aortic diameter/BSA (HR 1.55, CI 1.19-2.04, p < 0.01) and not-opening aortic valve (HR 4.73, CI 1.43-16.9, p = 0.01) were independent risk factors for significant AI. The cutoff value of proximal ascending aortic diameter/BSA was 15.5 (area under curve: 0.770, sensitivity: 0.69, specificity: 0.79). Dilated proximal ascending aorta at the time of LVAD surgery and not-opening aortic valve during follow-up were associated with the incidence of de novo significant AI.


Subject(s)
Aortic Valve Insufficiency , Heart-Assist Devices , Aorta/diagnostic imaging , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnosis , Aortic Valve Insufficiency/epidemiology , Aortic Valve Insufficiency/etiology , Heart-Assist Devices/adverse effects , Humans , Incidence , Retrospective Studies , Ventricular Function, Left
8.
Ann Thorac Surg ; 111(4): 1264-1270, 2021 04.
Article in English | MEDLINE | ID: mdl-32882197

ABSTRACT

BACKGROUND: The axillary intraaortic balloon pump (IABP) is frequently used in selected patients for circulatory support as a bridge to heart transplantation. The purpose of this study was to investigate the safety and efficacy of axillary intraaortic balloon pump (IABP) support for heart transplant candidates. METHODS: The study investigators collected data on 133 patients who underwent axillary IABP support as a bridge to transplantation from July 2009 to April 2019. Of these patients, 94 (70.7%) underwent IABP insertion with surgical axillary grafts, and 39 (29.3%) underwent percutaneous IABP insertion. The outcomes of interest included ambulatory data, IABP-related complications, and successful heart transplantation with this type of support. RESULTS: The overall preoperative ejection fraction was 20.3% ± 8.0%. The median duration of axillary IABP support was 21days, with 131patients (98.5%) mobilizing with the device. Hemodynamic variables significantly improved after the axillary IABP support was placed. Overall, 122 patients (91.7%) were successfully bridged to heart transplantation. Six patients (4.5%) required escalation to further mechanical support. Two patients (1.5%) died while awaiting transplantation. Four patients (3.0%) experienced a stroke during axillary IABP support (3 before transplantation and1 after transplantation). Two of the 3 patients with a stroke diagnosis before transplantation recovered and eventually underwent heart transplantation. CONCLUSIONS: With axillary IABP support, most patients were able to ambulate and undergo physical rehabilitation while waiting for heart transplantation. This study demonstrates that axillary IABP results in a high success rate of bridge to transplantation and a low number of complications. Thus, an ambulatory axillary IABP provided efficient and safe support for selected patients as a bridge to heart transplantation.


Subject(s)
Ambulatory Surgical Procedures/methods , Heart Failure/surgery , Heart Transplantation , Hemodynamics/physiology , Intra-Aortic Balloon Pumping/methods , Axillary Artery , Female , Heart Failure/physiopathology , Humans , Male , Middle Aged , Patient Selection , Retrospective Studies , Time Factors
9.
Artif Organs ; 44(4): 367-374, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31660619

ABSTRACT

The purpose of this study is to compare clinical outcomes of left ventricular assist device (LVAD) patients with device thrombosis who underwent device exchange (DE) or medical therapy (MT) alone. Consecutive patients undergoing LVAD implant between July 2008 and December 2017 were included. Device thrombosis was diagnosed with comprehensive assessments including ramp test, laboratory data, device parameters, and clinical presentations. First, MT was initiated in all patients. After MT, DE was considered if device thrombosis was refractory to initial MT, and it caused end-organ impairment and/or hemodynamic instability. Among 319 consecutive LVAD patients, 43 patients (13.5%) were diagnosed with device thrombosis. DE was performed in 28 patients (DE group); device explant was performed in 1 patient. MT was continued in 14 patients (MT group). In-hospital mortality was significantly lower in the DE group than the MT group (3.6% [1/28] vs. 28.6% [4/14], P = .0184). One-year survival was significantly better in the DE group (74.0% vs. 30.1%; log-rank = .001), and freedom from cerebrovascular accident (CVA) at 1 year was greater in the DE group (87.1% vs. 47.7%; log-rank = .004). DE was associated with improved 1-year survival and fewer CVAs. Surgical intervention, if feasible, is recommended for LVAD device thrombosis.


Subject(s)
Device Removal/statistics & numerical data , Heart Failure/mortality , Heart-Assist Devices/adverse effects , Thrombosis/surgery , Aged , Anticoagulants/administration & dosage , Chicago/epidemiology , Female , Heart Failure/therapy , Heparin/administration & dosage , Humans , Male , Middle Aged , Retrospective Studies , Thrombosis/drug therapy , Thrombosis/etiology
SELECTION OF CITATIONS
SEARCH DETAIL
...