Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
J Adv Prosthodont ; 8(6): 472-478, 2016 Dec.
Article in English | MEDLINE | ID: mdl-28018565

ABSTRACT

PURPOSE: The aim of this study was to analyze the shapes of lingual polished surfaces in lower complete dentures formed by polished surface impressions and to provide reference data for use when manufacturing edentulous trays and lower complete dentures. MATERIALS AND METHODS: Twenty-six patients with mandibular edentulism were studied. After lower wax dentures were fabricated, wax was removed from the lingual side of the wax denture and a lingual polished surface impression was obtained with tissue conditioner. The definitive denture was scanned with a three-dimensional scanner, and scanned images were obtained. At the cross-sections of the lingual frenum, lateral incisors, first premolars, first molars, and anterior border of the retromolar pads, three points were marked and eight measurements were taken. The Kruskal-Wallis test and a post hoc analysis with the Mann-Whitney test were performed. RESULTS: Each patient showed similar values for the same areas on the left and right sides without a statistically significant difference. The height of the contour of the lingual polished surface at the lingual frenum was halfway between the occlusal plane and lingual border, it moved gradually in a downward direction. The angle from the occlusal plane to the height of the contour of the lingual polished surface was increased as it progressed from the lingual frenum towards the retromolar pads. CONCLUSION: The shape of the mandibular lingual polished surface was convex at the lingual frenum, lateral incisors and gradually flattened towards the first molars and retromolar pads.

2.
J Adv Prosthodont ; 7(3): 207-13, 2015 Jun.
Article in English | MEDLINE | ID: mdl-26140172

ABSTRACT

PURPOSE: The purpose of this study was to examine the abutment screw stability of screw- and cement-retained implant-supported dental prosthesis (SCP) after simulated cement washout as well as the stability of SCP cements after complete loosening of abutment screws. MATERIALS AND METHODS: Thirty-six titanium CAD/CAM-made implant prostheses were fabricated on two implants placed in the resin models. Each prosthesis is a two-unit SCP: one screw-retained and the other cemented. After evaluating the passive fit of each prosthesis, all implant prostheses were randomly divided into 3 groups: screwed and cemented SCP (Control), screwed and noncemented SCP (Group 1), unscrewed and cemented SCP (Group 2). Each prosthesis in Control and Group 1 was screwed and/or cemented, and the preloading reverse torque value (RTV) was evaluated. SCP in Group 2 was screwed and cemented, and then unscrewed (RTV=0) after the cement was set. After cyclic loading was applied, the postloading RTV was measured. RTV loss and decementation ratios were calculated for statistical analysis. RESULTS: There was no significant difference in RTV loss ratio between Control and Group 1 (P=.16). No decemented prosthesis was found among Control and Group 2. CONCLUSION: Within the limits of this in vitro study, the stabilities of SCP abutment screws and cement were not significantly changed after simulated cement washout or screw loosening.

3.
Implant Dent ; 23(1): 51-6, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24398847

ABSTRACT

PURPOSE: The aim of this in vitro study was to evaluate reliability of the Periotest and Osstell Mentor in assessment of periimplant vertical and circular bone loss. MATERIALS AND METHODS: Sixteen dental implants were embedded into acrylic resin blocks. The portion of resin around the implant neck was successively removed to mimic periimplant vertical and circular bone loss. Measurement values of 2 devices were compared by assessing the change of Periotest value (PTV) and Implant Stability Quotient (ISQ) values, by calculating correlation analysis and by means of regression analysis referring to increasing bone loss. RESULTS: Both devices were able to discriminate differences of circular bone loss. However, PTVs were not noticeably changed in buccal, buccal-mesial, and buccal-mesial-distal bone loss. The differences in buccal and buccal-mesial bone loss were not discriminated by Osstell Mentor. As the range of bone loss was increased, there was a noticeable correlation of the PTV and ISQ values. CONCLUSIONS: The results of this study suggest that both diagnostic devices for implant stability are useful in detecting the circular bone loss. However, the clinical reliability of both devices for detecting the partial vertical bone loss is low.


Subject(s)
Alveolar Bone Loss/diagnosis , Dental Implants/standards , Dental Prosthesis Retention/methods , Alveolar Bone Loss/epidemiology , Dental Prosthesis Retention/standards , Humans , In Vitro Techniques , Osseointegration , Reproducibility of Results
4.
J Adv Prosthodont ; 5(3): 248-55, 2013 Aug.
Article in English | MEDLINE | ID: mdl-24049565

ABSTRACT

PURPOSE: This study compared the effect of three intraoral repair systems on the bond strength between composite resin and zirconia core. MATERIALS AND METHODS: THIRTY ZIRCONIA SPECIMENS WERE DIVIDED INTO THREE GROUPS ACCORDING TO THE REPAIR METHOD: Group I- CoJet™ Repair System (3M ESPE) [chairside silica coating with 30 µm SiO2 + silanization + adhesive]; Group II- Ceramic Repair System (Ivoclar Vivadent) [etching with 37% phosphoric acid + Zirconia primer + adhesive]; Group III- Signum Zirconia Bond (Heraus) [Signum Zirconia Bond I + Signum Zirconia Bond II]. Composite resin was polymerized on each conditioned specimen. The shear bond strength was tested using a universal testing machine, and fracture sites were examined with FE-SEM. Surface morphology and wettability after surface treatments were examined additionally. The data of bond strengths were statistically analyzed with one-way ANOVA and Tamhane post hoc test (α=.05). RESULTS: Increased surface roughness and the highest wettability value were observed in the CoJet sand treated specimens. The specimens treated with 37% phosphoric acid and Signum Zirconia Bond I did not show any improvement of surface irregularity, and the lowest wettability value were found in 37% phosphoric acid treated specimens. There was no significant difference in the bond strengths between Group I (7.80 ± 0.76 MPa) and III (8.98 ± 1.39 MPa). Group II (3.21 ± 0.78 MPa) showed a significant difference from other groups (P<.05). CONCLUSION: The use of Intraoral silica coating system and the application of Signum Zirconia Bond are effective for increasing the bond strength of composite resin to zirconia.

5.
J Adv Prosthodont ; 4(3): 146-52, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22977722

ABSTRACT

PURPOSE: The cortical bone thickness on the anterior region is important for achieving implant stability. The purpose of this study was to examine the thickness of the cortical and cancellous bones on the anterior region of the maxilla and mandible. MATERIALS AND METHODS: Twenty-five cadaver heads were used (16 male and 9 female; mean death age, 56.7 years). After the long axis of alveolar process was set up, it was measured in 5 levels starting from 2 mm below the cementoenamel junction (L1) at intervals of 3 mm. All data was analysed statistically by one-way ANOVA at the .05 significance level. RESULTS: The cortical bone thickness according to measurement levels in both the labial and lingual sides increased from L1 to L5, and the lingual side below L3 was significantly thicker than the labial side on the maxilla and mandible. In particular, the labial cortical bone thickness in the maxilla was the thinnest compared to the other regions. The cancellous bone thickness according to measurement levels increased from L1 to L5 on the maxilla, and on the mandible it was the thinnest at the middle level of the root. CONCLUSION: For implant placement on the anterior region, a careful evaluation and full knowledge on the thickness of the cortical and cancellous bone are necessary, therefore, these results may provide an anatomic guideline to clinicians.

6.
J Adv Prosthodont ; 3(2): 85-9, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21814617

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the amount of resorption and thickness of labial bone in anterior maxillary implant using cone beam computed tomography with Hitachi CB Mercuray (Hitachi, Medico, Tokyo, Japan). MATERIALS AND METHODS: Twenty-one patients with 26 implants were followed-up and checked with CBCT. 21 OSSEOTITE NT® (3i/implant Innovations, Florida, USA) and 5 OSSEOTITE® implants (3i/implant Innovations, Florida, USA) were placed at anterior region and they were positioned vertically at the same level of bony scallop of adjacent teeth. Whenever there was no lesion or labial bone was intact, immediate placement was tried as possible as it could be. Generated bone regeneration was done in the patients with the deficiency of hard tissue using Bio-Oss® (Geistlich, Wolhusen, Switzerland) and Bio-Gide® (Geistlich, Wolhusen, Switzerland). Second surgery was done in 6 months after implant placement and provisionalization was done for 3 months. Definite abutment was made of titanium abutment with porcelain, gold and zirconia, and was attached after provisionalization. Two-dimensional slices were created to produce sagittal, coronal, axial and 3D by using OnDemand3D (Cybermed, Seoul, Korea). RESULTS: The mean value of bone resorption (distance from top of implant to labial bone) was 1.32 ± 0.86 mm and the mean thickness of labial bone was 1.91 ± 0.45 mm. CONCLUSION: It is suggested that the thickness more than 1.91 mm could reduce the amount and incidence of resorption of labial bone in maxillary anterior implant.

7.
J Adv Prosthodont ; 2(3): 92-6, 2010 Sep.
Article in English | MEDLINE | ID: mdl-21165276

ABSTRACT

PURPOSE: The aim of this study was to evaluate the thickness of buccal and palatal alveolar bone and buccal bony curvature below root apex in maxillary anterior teeth of Korean adults using Cone-beam CT images. MATERIALS AND METHODS: The 3D image was reconstructed with dicom file obtained through CBCT from 20 - 39 year old Korean subjects (n = 20). The thickness of buccal and palatal plate, root diameter, the buccal bony curvature angle below root apex and the distance from root apex to the deepest point of buccal bony curvature were measured on maxillary anterior teeth area using OnDemand3D program. RESULTS: Mean thickness of buccal plate 3 mm below CEJ was 0.68 ± 0.29 mm at central incisor, 0.76 ± 0.59 mm at lateral incisor, and 1.07 ± 0.80 mm at canine. Mean thickness of palatal plate 3 mm below CEJ was 1.53 ± 0.55 mm of central incisor, 1.18 ± 0.66 mm of lateral incisor, 1.42 ± 0.77 mm of canine. Bucco-lingual diameter 3 mm below CEJ was 5.13 ± 0.37 mm of central incisor, 4.58 ± 0.46 mm of lateral incisor, and 5.93 ± 0.47 mm of canine. Buccal bony curvature angle below root apex was 134.7 ± 17.5° at central incisor, 151.0 ± 13.9° at lateral incisor, 153.0 ± 9.5° at canine. Distance between root apex and the deepest point of buccal bony curvature of central incisor was 3.67 ± 1.28 mm at central incisor, 3.90 ± 1.51 mm at lateral incisor, and 5.13 ± 1.70 mm at canine. CONCLUSION: Within the limitation of this study in Korean adults, the thickness of maxillary anterior buccal plate was very thin within 1mm and the thickness of palatal plate was thick, relatively. The buccal bony curvature below root apex of maxillary central incisor was higher than that of lateral incisor and canine and it seems that the buccal bony plate below root apex of central incisor is most curved.

8.
J Adv Prosthodont ; 1(2): 97-101, 2009 Jul.
Article in English | MEDLINE | ID: mdl-21165262

ABSTRACT

STATEMENT OF PROBLEM: Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE: In this study, Bicon® Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS: 10 Bicon® implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS: It was evident, that the amount of abutment sinking in Bicon® Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at 0.45 ± 0.09 mm. CONCLUSION: Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location.

9.
J Adv Prosthodont ; 1(2): 102-6, 2009 Jul.
Article in English | MEDLINE | ID: mdl-21165263

ABSTRACT

STATEMENT OF PROBLEM: Screw loosening has been a common complication and still reported frequently. PURPOSE: The purpose of this study was to evaluate abrasion of the implant fixture and TiN coated abutment screw after repeated delivery and removal with universal measuring microscope. MATERIAL AND METHODS: Implant systems used for this study were Osstem and 3i. Seven pairs of implant fixtures, abutments and abutment screws for each system were selected and all the fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. After 20 times of repeated closing and opening test, the evaluation for the change of inner surface of implant and TiN-coated abutment screw, and weight loss were measured. Mann-Whitney test with SPSS statistical software for Window was applied to analyze the measurement of weight loss. RESULTS: TiN-coated abutment screws of Osstem and 3i showed lesser loss of weight than non-coated those of Osstem and 3i (P < .05, Mann-Whitney test). CONCLUSION: Conclusively, TiN coating of abutment screw showed better resistance to abrasion than titanium abutment screw. It was concluded that TiN coating of abutment screw would reduce the loss of preload with good abrasion resistance and low coefficient of friction, and help to maintain screw joint stability.

10.
Int J Oral Maxillofac Implants ; 17(1): 86-94, 2002.
Article in English | MEDLINE | ID: mdl-11858578

ABSTRACT

PURPOSE: To evaluate the effect of particulate dentin-plaster of Paris with and without platelet-rich plasma (PRP) on bone healing and new bone formation around titanium dental implants in a canine model. Histologic sections and histomorphometric analysis of the defects were obtained at 6 and 12 weeks after surgery. MATERIALS AND METHODS: Three circular bone defects were surgically prepared in iliac crest sites in each of 10 animals. A total of 30 Avana dental implants were placed in the animals. They were self-tapping, screw-type implants, 10 mm in length and 4 mm in diameter, all made of commercially pure titanium. A titanium implant was placed centrally in each defect. In each dog, the defects were treated with 1 of the following 3 treatment modalities: (1) no treatment (control); (2) grafting with particulate dentin-plaster of Paris; (3) grafting with particulate dentin-plaster of Paris and PRP. RESULTS: Histologic analysis showed that all of the bone defects surrounding the implants that were treated with particulate dentin-plaster of Paris, with and without PRP, were filled with new bone. The defects that were not treated (control) demonstrated new bone formation only in the inferior threaded portion of the implants. DISCUSSION: Histomorphometric results revealed a higher percentage of bone contact with particulate dentin-plaster of Paris and PRP compared to the control and particulate dentin-plaster of Paris. CONCLUSIONS: These results suggested that bone defects around titanium implants can be treated successfully with particulate dentin-plaster of Paris, and that the outcome can be improved if PRP is also used.


Subject(s)
Bone Resorption/drug therapy , Calcium Sulfate/therapeutic use , Dental Implants , Dental Materials/therapeutic use , Dentin/transplantation , Osteogenesis/drug effects , Platelet Transfusion , Analysis of Variance , Animals , Bone Resorption/etiology , Bone Resorption/surgery , Calcium Sulfate/pharmacology , Dental Implantation, Endosseous/adverse effects , Dental Implants/adverse effects , Dental Materials/pharmacology , Dogs , Female , Ilium/surgery , Implants, Experimental/adverse effects , Male , Osteogenesis/physiology , Platelet-Derived Growth Factor/therapeutic use , Statistics, Nonparametric
SELECTION OF CITATIONS
SEARCH DETAIL
...