Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
Add more filters










Publication year range
1.
Rev Sci Instrum ; 85(9): 096109, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25273795

ABSTRACT

The Versatile Ion Source (VIS) is a microwave discharge ion source installed at INFN-LNS and here used as test-bench for the production of high intensity low emittance proton beams and for studies on plasma physics. A series of measurements have been carried out with VIS in order to test the source with light ions. In particular a He(+) beam has been characterized in terms of plasma discharge parameters. The experiment has been triggered by the observation of X-radiation emission from the plasma for some configuration of the magnetic field profile. The plasma electron energy distribution function is in fact modified when in some regions of the plasma chamber under-resonance discharge takes place, fulfilling the condition that allows the electromagnetic wave to electrostatic wave conversion. These tests allowed obtaining more than 50 mA of He(+) beams.

2.
Rev Sci Instrum ; 85(2): 02A511, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24593434

ABSTRACT

The paper proposes a new model of ion confinement in ECRIS, which can be easily generalized to any magnetic configuration characterized by closed magnetic surfaces. Traditionally, ion confinement in B-min configurations is ascribed to a negative potential dip due to superhot electrons, adiabatically confined by the magneto-static field. However, kinetic simulations including RF heating affected by cavity modes structures indicate that high energy electrons populate just a thin slab overlapping the ECR layer, while their density drops down of more than one order of magnitude outside. Ions, instead, diffuse across the electron layer due to their high collisionality. This is the proper physical condition to establish a double-layer (DL) configuration which self-consistently originates a potential barrier; this "barrier" confines the ions inside the plasma core surrounded by the ECR surface. The paper will describe a simplified ion confinement model based on plasma density non-homogeneity and DL formation.

3.
Rev Sci Instrum ; 85(2): 02A723, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24593457

ABSTRACT

The design update of the European Spallation Source (ESS) accelerator is almost complete and the construction of the prototype of the microwave discharge ion source able to provide a proton beam current larger than 70 mA to the 3.6 MeV Radio Frequency Quadrupole (RFQ) started. The source named PS-ESS (Proton Source for ESS) was designed with a flexible magnetic system and an extraction system able to merge conservative solutions with significant advances. The ESS injector has taken advantage of recent theoretical updates and new plasma diagnostics tools developed at INFN-LNS (Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare). The design strategy considers the PS-ESS and the low energy beam transport line as a whole, where the proton beam behaves like an almost neutralized non-thermalized plasma. Innovative solutions have been used as hereinafter described. Thermo-mechanical optimization has been performed to withstand the chopped beam and the misaligned focused beam over the RFQ input collimator; the results are reported here.

4.
Rev Sci Instrum ; 85(2): 02A956, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24593535

ABSTRACT

An experimental campaign aiming to detect X radiation emitted by the plasma of the CAPRICE source - operating at GSI, Darmstadt - has been carried out. Two different detectors (a SDD - Silicon Drift Detector and a HpGe - hyper-pure Germanium detector) have been used to characterize the warm (2-30 keV) and hot (30-500 keV) electrons in the plasma, collecting the emission intensity and the energy spectra for different pumping wave frequencies and then correlating them with the CSD of the extracted beam measured by means of a bending magnet. A plasma emissivity model has been used to extract the plasma density along the cone of sight of the SDD and HpGe detectors, which have been placed beyond specific collimators developed on purpose. Results show that the tuning of the pumping frequency considerably modifies the plasma density especially in the warm electron population domain, which is the component responsible for ionization processes: a strong variation of the plasma density near axis region has been detected. Potential correlations with the charge state distribution in the plasma are explored.

5.
Rev Sci Instrum ; 83(5): 056109, 2012 May.
Article in English | MEDLINE | ID: mdl-22667673

ABSTRACT

The high intensity ion source (SILHI), in operation at CEA-Saclay, has been used to produce a 90 mA pulsed proton beam with pulse length and repetition rates suitable for the European Spallation Source (ESS) linac. Typical r-r(') rms normalized emittance values smaller than 0.2π mm mrad have been measured for operation in pulsed mode (0.01 < duty cycle < 0.15 and 1 ms < pulse duration < 10 ms) that are relevant for the design update of the Linac to be used at the ESS in Lund.

6.
Rev Sci Instrum ; 83(2): 02A305, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22380152

ABSTRACT

The versatile ion source (VIS) is an off-resonance microwave discharge ion source which generates a slightly overdense plasma (n(e) ≈ 10(17) cm(-3)) operating at 2.45 GHz and producing more than 50 mA of proton beams. A detailed characterization of the source, by operating between 60 and 75 kV, in terms of emittance, current extracted and proton fraction is reported below. Moreover, passive techniques (alumina coating of the plasma chamber walls, BN disks at the injection and extraction endplates) have been used to improve the performance of the source, increasing the electron density for a more efficient ionization. The know-how achieved with the VIS source may be useful for the different project, particularly for the European spallation source.

7.
Rev Sci Instrum ; 83(2): 02A319, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22380166

ABSTRACT

The production of intense beams of heavy ions with electron cyclotron resonance ion sources (ECRIS) is an important request at many accelerators. According to the ECR condition and considering semi-empirical scaling laws, it is essential to increase the microwave frequency together with the magnetic flux density of the ECRIS magnet system. A useful frequency of 28 GHz, therefore, requires magnetic flux densities above 2.2 T implying the use of superconducting magnets. A cooperation of European institutions initiated a project to build a multipurpose superconducting ECRIS (MS-ECRIS) in order to achieve an increase of the performances in the order of a factor of ten. After a first design of the superconducting magnet system for the MS-ECRIS, the respective cold testing of the built magnet system reveals a lack of mechanical performance due to the strong interaction of the magnetic field of the three solenoids with the sextupole field and the magnetization of the magnetic iron collar. Comprehensive structural analysis, magnetic field calculations, and calculations of the force pattern confirm thereafter these strong interactions, especially of the iron collar with the solenoidal fields. The investigations on the structural analysis as well as suggestions for a possible mechanical design solution are given.

8.
Rev Sci Instrum ; 83(2): 02A330, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22380177

ABSTRACT

The code here presented is the first part of a Monte Carlo (MC) self-consistent 3D plasma simulator. It is yet able to solve the equation of motion for thousands of independent charged particles. The procedure allows to understand the consequences of each phenomenon introduced in the evolution steps of the code. MC random selection of starting parameters is used for each particles; the environmental conditions enclosed in the simulation are ECRIS magnetic field, resonant electromagnetic wave, initial plasma density distribution and MC calculation of Spitzer collision. The results of the first simulations explain some typical effects as the hollow beam formation and the main plasma deconfinement mechanism.

9.
Rev Sci Instrum ; 83(2): 02A336, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22380183

ABSTRACT

Further improvements of electron cyclotron resonance ion sources (ECRIS) output currents and average charge state require a deep understanding of electron and ion dynamics in the plasma. This paper will discuss the most recent advances about modeling of non-classical evidences like the sensitivity of electron energy distribution function to the magnetic field detuning, the influence of plasma turbulences on electron heating and ion confinement, the coupling between electron and ion dynamics. All these issues have in common the non-homogeneous distribution of the plasma inside the source: the abrupt density drop at the resonance layer regulates the heating regimes (from collective to turbulent), the beam formation mechanism and emittance. Possible means to boost the performances of future ECRIS will be proposed. In particular, the use of Bernstein waves, in preliminary experiments performed at Laboratori Nazionali del Sud (LNS) on MDIS (microwave discharge ion sources)-type sources, has permitted to sustain largely overdense plasmas enhancing the warm electron temperature, which will make possible in principle the construction of sources for high intensity multicharged ions beams with simplified magnetic structures.

10.
Rev Sci Instrum ; 83(2): 02B501, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22380300

ABSTRACT

A microwave discharge ion source (MDIS) operating at the Laboratori Nazionali del Sud of INFN, Catania has been used to compare the traditional electron cyclotron resonance (ECR) heating with an innovative mechanisms of plasma ignition based on the electrostatic Bernstein waves (EBW). EBW are obtained via the inner plasma electromagnetic-to-electrostatic wave conversion and they are absorbed by the plasma at cyclotron resonance harmonics. The heating of plasma by means of EBW at particular frequencies enabled us to reach densities much larger than the cutoff ones. Evidences of EBW generation and absorption together with X-ray emissions due to high energy electrons will be shown. A characterization of the discharge heating process in MDISs as a generalization of the ECR heating mechanism by means of ray tracing will be shown in order to highlight the fundamental physical differences between ECR and EBW heating.

11.
Rev Sci Instrum ; 81(2): 02A319, 2010 Feb.
Article in English | MEDLINE | ID: mdl-20192340

ABSTRACT

Ion beam intensity and quality have a crucial effect on the operation efficiency of the accelerator facilities. This paper presents the investigations on the ion beam intensity and quality after the mass separation performed with the Department of Physics, University of Jyväskylä 14 GHz electron cyclotron resonance ion source by sweeping the microwave in the 14.05-14.13 GHz range. In many cases a clear variation in the ion beam intensity and quality as a function of the frequency was observed. The effect of frequency tuning increased with the charge state. In addition, clear changes in the beam structure seen with the beam viewer were observed. The results confirmed that frequency tuning can have a remarkable effect on ion beam intensity and quality especially in the case of highly charged ion beams. The examples presented here represent the typical charge state behavior observed during the measurements.

12.
Rev Sci Instrum ; 81(2): 02A333, 2010 Feb.
Article in English | MEDLINE | ID: mdl-20192354

ABSTRACT

Coupling improvements between microwaves and plasmas are a key factor to design more powerful electron cyclotron resonance and microwave ion sources. On this purpose different activities have been undertaken by the INFN-LNS ion source team and a new approach was developed. Recent experiments confirmed the simulations, demonstrating that even in presence of a dense plasma, resonant modes are excited inside the cavity and the plasma dynamics depends on their structure. An overview of the coupling issues on microwave ion sources is also given along with a discussion on alternative coupling techniques.

13.
Rev Sci Instrum ; 81(2): 02A334, 2010 Feb.
Article in English | MEDLINE | ID: mdl-20192355

ABSTRACT

In electron cyclotron resonance ion sources it has been demonstrated that plasma heating may be improved by means of different microwave to plasma coupling mechanisms, including the "frequency tuning" and the "two frequency heating." These techniques affect evidently the electron dynamics, but the relationship with the ion dynamics has not been investigated in details up to now. Here we will try to outline these relations: through the study of ion dynamics we may try to understand how to optimize the electron cyclotron resonance ion sources brightness. A simple model of the ion confinement and beam formation will be presented, based on particle-in-cell and single particle simulations.

14.
Rev Sci Instrum ; 81(2): 02B313, 2010 Feb.
Article in English | MEDLINE | ID: mdl-20192436

ABSTRACT

The suitable source for the production of intense beams for high power accelerators must obey to the request of high brightness, stability, and reliability. The 2.45 GHz off-resonance microwave discharge sources are the ideal device to generate the requested beams, as they produce multimilliampere beams of protons, deuterons, and monocharged ions, remaining stable for several weeks without maintenance. A description of different technical designs will be given, analyzing their strength, and weakness, with regard to the extraction system and low energy beam transport line, as the presence of beam halo is detrimental for the accelerator.

15.
Rev Sci Instrum ; 79(2 Pt 2): 02A308, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18315098

ABSTRACT

In an electron cyclotron resonance ion source, ions are produced from a plasma generated and sustained by microwaves with a proper frequency. Some experiments showed that the plasma formation, the consequent amount of particles extracted from the source, and the related beam shape strongly depend on the frequency of the electromagnetic wave feeding the cavity. In order to have a better understanding of these phenomena, in this work we deal with the description of the motion of a charged particle inside the plasma chamber model of the SERSE ion source operating at INFN-LNS in Catania, the analysis being applicable to any similar apparatus. The electromagnetic fields inside the vacuum filled chamber were determined theoretically and, together with proper simulations, their fundamental role on the particle motion, on their confinement, and on the energy transfer they are subjected to during their motion within the cavity is shown.

16.
Rev Sci Instrum ; 79(2 Pt 2): 02A326, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18315116

ABSTRACT

Intense heavy ion beam production with electron cyclotron resonance (ECR) ion sources is a common requirement for many of the accelerators under construction in Europe and elsewhere. An average increase of about one order of magnitude per decade in the performance of ECR ion sources was obtained up to now since the time of pioneering experiment of R. Geller at CEA, Grenoble, and this trend is not deemed to get the saturation at least in the next decade, according to the increased availability of powerful magnets and microwave generators. Electron density above 10(13) cm(-3) and very high current of multiply charged ions are expected with the use of 28 GHz microwave heating and of an adequate plasma trap, with a B-minimum shape, according to the high B mode concept [S. Gammino and G. Ciavola, Plasma Sources Sci. Technol. 5, 19 (1996)]. The MS-ECRIS ion source has been designed following this concept and its construction is underway at GSI, Darmstadt. The project is the result of the cooperation of nine European institutions with the partial funding of EU through the sixth Framework Programme. The contribution of different institutions has permitted to build in 2006-2007 each component at high level of expertise. The description of the major components will be given in the following with a view on the planning of the assembly and commissioning phase to be carried out in fall 2007. An outline of the experiments to be done with the MS-ECRIS source in the next two years will be presented.

17.
Rev Sci Instrum ; 79(2 Pt 1): 023305, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18315291

ABSTRACT

A set of measurements with the CAPRICE ion source at the GSI test bench has been carried out to investigate its behavior in terms of intensity and shape of the extracted beam when the microwaves generating the plasma sweep in a narrow range of frequency (+/-40 MHz) around the klystron center frequency (14.5 GHz). Remarkable variations have been observed depending on the source and the beamline operating parameters, confirming that a frequency dependent electromagnetic distribution is preserved even in the presence of plasma inside the source. Moreover, these observations confirm that the frequency tuning is a powerful method to optimize the electron cyclotron resonance ion source performances. A description of the experimental setup and of the obtained results is given in the following.

18.
J Neurosurg Sci ; 46(3-4): 147-9, 2002 Dec.
Article in English | MEDLINE | ID: mdl-12690340

ABSTRACT

Metastatic involvement of brachial plexopathy is a rare condition that is often associated with advanced systemic breast cancer and the role of surgeon appears to be restricted because radio-chemotherapy is better recommended in this setting. We report a case of a 64-year-old woman that presented a very delayed breast cancer metastatic lower trunks lesions without associated radiation injury, treated by surgery. MRI of plexus and CT of chest and axilla are methods of choice in preoperative radiological evaluation. Neurosurgeon effort is restricted to provide pathologic diagnosis (confirm of metastasis), adequate pain control and improvement of neurological function. So that surgical exploration and neurolysis should be performed as soon as possible after appearance of neurological deficits before denervation signs occurs. General surgeon presence should be warranted for more radical removal of remain lymph nodes and metastatic nodal infiltration of adjacent anatomical structures (vessels and so on) when detected by preoperative radiological work-up.


Subject(s)
Brachial Plexus Neuropathies/surgery , Breast Neoplasms/pathology , Neoplasms, Second Primary/surgery , Peripheral Nervous System Neoplasms/secondary , Peripheral Nervous System Neoplasms/surgery , Brachial Plexus Neuropathies/physiopathology , Female , Humans , Lymphatic Metastasis , Middle Aged , Time Factors , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...