Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
G Ital Cardiol (Rome) ; 19(9): 519-529, 2018 Sep.
Article in Italian | MEDLINE | ID: mdl-30087514

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has revolutionized the management of patients with symptomatic severe aortic stenosis and has become the standard of care for inoperable patients and the preferred therapy for those at increased surgical risk with peculiar clinical and anatomic features. Technology advances, growing experience and accumulating data prompted the update of the 2011 Italian Society of Interventional Cardiology (SICI-GISE) position paper on institutional and operator requirements to perform TAVI. The main objective of this document is to provide a guidance to assess the potential of institutions and operators to initiate and maintain an efficient TAVI program.


Subject(s)
Aortic Valve Stenosis/surgery , Program Development/methods , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/physiopathology , Biomedical Technology/trends , Humans , Italy , Severity of Illness Index , Transcatheter Aortic Valve Replacement/instrumentation
2.
J Cardiovasc Med (Hagerstown) ; 10(2): 212-4, 2009 Feb.
Article in English | MEDLINE | ID: mdl-19377387

ABSTRACT

In patients with acute aortic dissection, an early diagnosis is essential to anticipate aortic rupture, cardiac tamponade, organ ischemia and improve surgical results. A specific blood laboratory marker able to rule out the presence of aortic dissection has not been identified yet. Recently, several studies suggested using D-dimers as a negative predicting test to rule out diagnosis of acute aortic dissection in patients presenting with chest pain. In 61 patients with confirmed aortic dissection, preoperative D-dimers were assayed and correlated with time from symptom onset and extension of the false lumen dissection (according with De Bakey classification). Abnormal D-dimers values were considered those being greater than 400 microg/l. D-dimers values were above 400 microg/l in 50 patients (82%) and below 400 microg/l in 11 patients (18%). There was no correlation between preoperative D-dimers values and time from symptoms onset (r = -0.232; P = 0.1). We found that D-dimers are not always elevated in patients presenting with acute aortic dissection. Given the potential devastating effects of denying the diagnosis of acute aortic dissection with consequent delay of adequate treatment, a word of caution regarding the negative predictive value of D-dimer test in the diagnosis of aortic dissection seems warranted.


Subject(s)
Aortic Aneurysm/diagnosis , Aortic Dissection/diagnosis , Fibrin Fibrinogen Degradation Products/analysis , Acute Disease , Adult , Aged , Aortic Dissection/blood , Aortic Dissection/complications , Aortic Aneurysm/blood , Aortic Aneurysm/complications , Biomarkers/blood , Chest Pain/blood , Chest Pain/etiology , False Negative Reactions , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Up-Regulation
SELECTION OF CITATIONS
SEARCH DETAIL
...