Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
2.
Aging Clin Exp Res ; 29(Suppl 1): 127-130, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27896794

ABSTRACT

BACKGROUND: Ultrasound-guidance has become the routine method for internal jugular vein (IJV) catheterization reducing dramatically failure and complication rates for central venous port (CVP) placement. AIMS: The aim of this study was to determine the safety and efficacy of ultrasound-guided IJV CVP placement in elderly oncologic patients. METHODS: Between January 2013 and December 2015, 101 elderly oncological patients underwent right IJV CVP placement under ultrasound-guidance. The length of catheter introduction ranged from 18 to 21 cm. Intraoperative fluoroscopy (IF) was always performed intraoperatively. Chest X-ray (CXR) was always performed 30 min after the end of the procedure. RESULTS: The morbidity rate was 1.98%; two arterial punctures were reported with one self-limiting hematoma. Two patients (1.98%) had catheter misplacements, recognized by intraoperative IF. No patients (0%) experienced pneumothorax (PNX), confirmed at CXR. Patients were all discharged at maximum 6 h from the procedure. DISCUSSION: The risk of catheter misplacement, PNX, and arterial/nerve puncture remains present with this technique. Lower rates of catheter misplacement have been reported after right IJV puncture, probably for its straight vertical course. Our results are in accordance with literature (1 counter-lateral subclavian vein and 1 counter-lateral internal jugular vein misplacements). All misplacements were detected intraoperatively. The PNX rates after cannulation of the IJV vary between 0.0 and 0.5%. We had no PNX occurrence. CONCLUSION: Ultrasonography (US) has improved safety and effectiveness of port system placements. While routine post-procedural CXR seems avoidable, IF should be considered mandatory.


Subject(s)
Catheterization, Central Venous , Postoperative Complications , Surgery, Computer-Assisted , Ultrasonography/methods , Aged , Aged, 80 and over , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/instrumentation , Catheterization, Central Venous/methods , Female , Humans , Italy , Jugular Veins/surgery , Male , Monitoring, Intraoperative/methods , Oncology Service, Hospital/statistics & numerical data , Outcome and Process Assessment, Health Care , Postoperative Complications/diagnosis , Postoperative Complications/therapy , Retrospective Studies , Surgery, Computer-Assisted/adverse effects , Surgery, Computer-Assisted/methods , Vascular Access Devices
SELECTION OF CITATIONS
SEARCH DETAIL
...