Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Cancers (Basel) ; 14(23)2022 Nov 28.
Article in English | MEDLINE | ID: mdl-36497347

ABSTRACT

Aim: To evaluate the role of MR relaxometry and derived proton density analysis in the prediction of early treatment response after two cycles of neoadjuvant therapy (NAT), in patients with breast cancer. Methods: This was a prospective study that included 59 patients with breast cancer, who underwent breast MRI prior (MRI1) and after two cycles of NAT (MRI2). The MRI1 included a sequential acquisition with five different TE's (50, 100, 150, 200 and 250 ms) and a TR of 5000 ms. Post-processing was used to obtain the T2 relaxometry map from the MR acquisition. The tumor was delineated and seven relaxometry and proton density parameters were extracted. Additional histopathology data, T2 features and ADC were included. The response to NAT was reported based on the MRI2 as responders: partial response (>30% decreased size) and complete response (no visible tumor stable disease (SD); and non-responders: stable disease or progression (>20% increased size). Statistics was done using Medcalc software. Results: There were 50 (79.3%) patients with response and 13 (20.7%) non-responders to NAT. Age, histologic type, "in situ" component, tumor grade, estrogen and progesterone receptors, ki67% proliferation index and HER2 status were not associated with NAT response (all p > 0.05). The nodal status (N) 0 was associated with early response, while N2 was associated with non-response (p = 0.005). The tumor (T) and metastatic (M) stage were not statistically significant associated with response (p > 0.05). The margins, size and ADC values were not associated with NAT response (p-value > 0.05). The T2 min relaxometry value was associated with response (p = 0.017); a cut-off value of 53.58 obtained 86% sensitivity (95% CI 73.3−94.2), 69.23 specificity (95% CI 38.6−90.9), with an AUC = 0.715 (p = 0.038). The combined model (T2 min and N stage) achieved an AUC of 0.826 [95% CI: 0.66−0.90, p-value < 0.001]. Conclusions: MR relaxometry may be a useful tool in predicting early treatment response to NAT in breast cancer patients.

2.
Cancers (Basel) ; 14(16)2022 Aug 12.
Article in English | MEDLINE | ID: mdl-36010897

ABSTRACT

The purpose of this study was to evaluate the diagnostic performance of radiomic features extracted from standardized hybrid contrast-enhanced ultrasound (CEUS) data for the assessment of hormone receptor status, human epidermal growth factor receptor 2 (HER2) status, tumor grade and Ki-67 in patients with primary breast cancer. METHODS: This prospective study included 72 patients with biopsy-proven breast cancer who underwent CEUS examinations between October 2020 and September 2021. RESULTS: A radiomic analysis found the WavEnHH_s_4 parameter as an independent predictor associated with the HER2+ status with 76.92% sensitivity, and 64.41% specificity and a prediction model that could differentiate between the HER2 entities with 76.92% sensitivity and 84.75% specificity. The RWavEnLH_s-4 parameter was an independent predictor for estrogen receptor (ER) status with 55.93% sensitivity and 84.62% specificity, while a prediction model (RPerc01, RPerc10 and RWavEnLH_s_4) could differentiate between the progesterone receptor (PR) status with 44.74% sensitivity and 88.24% specificity. No texture parameter showed statistically significant results at the univariate analysis when comparing the Nottingham grade and the Ki-67 status. CONCLUSION: Our preliminary data indicate a potential that hybrid CEUS radiomic features allow the discrimination between breast cancers of different receptor and HER2 statuses with high specificity. Hybrid CEUS radiomic features might have the potential to provide a noninvasive, easily accessible and contrast-agent-safe method to assess tumor biology before and during treatment.

3.
Diagnostics (Basel) ; 12(4)2022 Mar 24.
Article in English | MEDLINE | ID: mdl-35453846

ABSTRACT

The purpose of this study was to determine the observer agreement in assessing the enhancement pattern of suspicious breast lesions with contrast-enhanced ultrasound (CEUS) using high and low frequency transducers. Methods: This prospective study included 70 patients with suspicious breast lesions detected at mammography and/or ultrasound and classified according to the American College of Radiology (ACR) Breast Imaging-Reporting and Data System (BI-RADS) in 4A, 4B, 4C, or 5, who underwent CEUS examinations between October 2020 and August 2021. Results: Participants' ages ranged from 28 to 83 years (48.5 + 6.36, mean age + SD). We obtained a substantial agreement for the first reader (kappa = 0.614, p < 0.001) and a perfect agreement for the second and third reader (kappa = 1, p < 0.001) between the two transducers for the uptake pattern. A moderate agreement for the second and third reader (kappa = 0.517 and 0.538, respectively, p < 0.001) and only a fair agreement (kappa = 0.320, p < 0.001) in the case of the first reader for the perilesional enhancement was observed. We obtained an excellent inter-observer agreement (Cronbach's Alpha coefficient = 0.960, p < 0.001) for the degree of enhancement, a good inter-observer agreement for the uptake pattern and perilesional enhancement (Cronbach's Alpha coefficient = 0.831 and 0.853, respectively, p < 0.001), and a good and acceptable inter-observer agreement for internal homogeneity, perfusion defects and margins of the lesions (Cronbach's Alpha coefficient = 0.703, 0.703 and 0.792, respectively, p < 0.001) concerning the evaluation of breast lesions with the linear-array transducer. Conclusions: The evaluation of suspicious breast lesions by three experts with high-frequency linear-array transducer and low-frequency convex-array transducer was comparable in terms of uptake pattern and perilesional enhancement. The agreement regarding the evaluation of the degree of enhancement, the internal homogeneity, and the perfusion defects varied between fair and substantial. For all CEUS characteristics, the inter-observer agreement was superior for linear-array transducer, which leads to more a homogeneous and reproducible interpretation.

4.
Diagnostics (Basel) ; 12(2)2022 Feb 11.
Article in English | MEDLINE | ID: mdl-35204550

ABSTRACT

The purpose of the present study was to evaluate the value of full-field digital mammography (FFDM) and automated breast ultrasound (ABUS) in the diagnosis of breast cancer compared to FFDM associated with digital breast tomosynthesis (DBT). Methods: This retrospective study included 50 female patients with a denser framework of connective tissue fibers, characteristic of young women who underwent FFDM, DBT, handheld ultrasound (HHUS), and ABUS between January 2017 and October 2018. The sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), and accuracy of FFDM+ABUS were 81.82% (95% CI [48.22-97.72]), 89.74% (95% CI [75.78-97.13]), 69.23% (95% CI [46.05-85.57]), 94.59% (95% CI [83.26-98.40]), and 88% (95% CI [75.69-95.47]), while for FFDM+DBT, the values were as follows: 91.67% (95% CI [61.52-99.79]), 71.79% (95% CI [55.13-85.00]), 50% (95% CI [37.08-62.92]), 96.55% (95% CI [80.93-99.46]), 76.47% (95% CI [62.51-87.21]). We found an almost perfect agreement between the two readers regarding FFDM associated with ABUS, and substantial agreement regarding FFDM+DBT, with a kappa coefficient of 0.896 and 0.8, respectively; p < 0.001. Conclusions: ABUS and DBT are suitable as additional diagnostic imaging techniques to FFDM in women at an intermediate risk of developing breast cancer through the presence of dense breast tissue. In this study, DBT reduced the number of false negative results, while the use of ABUS resulted in an increase in specificity.

5.
Diagnostics (Basel) ; 11(7)2021 Jul 13.
Article in English | MEDLINE | ID: mdl-34359332

ABSTRACT

BACKGROUND: The purpose of this study was to assess the effectiveness of the radiomic analysis of contrast-enhanced spectral mammography (CESM) in discriminating between breast cancers and background parenchymal enhancement (BPE). METHODS: This retrospective study included 38 patients that underwent CESM examinations for clinical purposes between January 2019-December 2020. A total of 57 malignant breast lesions and 23 CESM examinations with 31 regions of BPE were assessed through radiomic analysis using MaZda software. The parameters that demonstrated to be independent predictors for breast malignancy were exported into the B11 program and a k-nearest neighbor classifier (k-NN) was trained on the initial groups of patients and was tested using a validation group. Histopathology results obtained after surgery were considered the gold standard. RESULTS: Radiomic analysis found WavEnLL_s_2 parameter as an independent predictor for breast malignancies with a sensitivity of 68.42% and a specificity of 83.87%. The prediction model that included CH1D6SumAverg, CN4D6Correlat, Kurtosis, Perc01, Perc10, Skewness, and WavEnLL_s_2 parameters had a sensitivity of 73.68% and a specificity of 80.65%. Higher values were obtained of WavEnLL_s_2 and the prediction model for tumors than for BPEs. The comparison between the ROC curves provided by the WaveEnLL_s_2 and the entire prediction model did not show statistically significant results (p = 0.0943). The k-NN classifier based on the parameter WavEnLL_s_2 had a sensitivity and specificity on training and validating groups of 71.93% and 45.16% vs. 60% and 44.44%, respectively. CONCLUSION: Radiomic analysis has the potential to differentiate CESM between malignant lesions and BPE. Further quantitative insight into parenchymal enhancement patterns should be performed to facilitate the role of BPE in personalized clinical decision-making and risk assessment.

6.
J Pers Med ; 11(8)2021 Jul 23.
Article in English | MEDLINE | ID: mdl-34442347

ABSTRACT

Automated breast ultrasound (ABUS) is an ultrasound technique that tends to be increasingly used as a supplementary technique in the evaluation of patients with dense glandular breasts. Patients with dense breasts have an increased risk of developing breast cancer compared to patients with fatty breasts. Furthermore, for this group of patients, mammography has a low sensitivity in detecting breast cancers, especially if it is not associated with architectural distortion or calcifications. ABUS is a standardized examination with many advantages in both screening and diagnostic settings: it increases the detection rate of breast cancer, improves the workflow, and reduces the examination time. On the other hand, like any imaging technique, ABUS has disadvantages and even some limitations. Many disadvantages can be diminished by additional attention and training. Disadvantages regarding image acquisition are the inability to assess the axilla, the vascularization, and the elasticity of a lesion, while concerning the interpretation, the disadvantages are the artifacts due to poor positioning, lack of contact, motion or lesion related. This article reviews and discusses the indications, the advantages, and disadvantages of the method and also the sources of error in the ABUS examination.

7.
Med Pharm Rep ; 93(4): 335-341, 2020 Oct.
Article in English | MEDLINE | ID: mdl-33225258

ABSTRACT

Breast cancer screening programs using mammography proved their value in detecting breast cancer at early stages and, consequently, reducing the mortality from this disease. Due to the technological progress, the screening programs have shifted from screen-film mammography to digital mammography and nowadays digital breast tomosynthesis became the focus of breast imaging research. Using tomosynthesis in screening increases cancer detection rates and decreases recall and false-positive rates, thus improving the effectiveness of breast cancer screening programs, with positive consequences on health care costs and on patient psychology. More long-term follow-up data must be collected for assessing absolute sensitivity and specificity of digital breast tomosynthesis, together with efforts for addressing the limitations of the method.

8.
Med Ultrason ; 21(2): 200-203, 2019 May 02.
Article in English | MEDLINE | ID: mdl-31063527

ABSTRACT

Metastases to the skeletal muscle from breast cancer represent an unusual and rare condition. We present the case of a 27-year-old female with left breast cancer (IDC NST G3) who underwent neoadjuvant chemotherapy followed by conservativesurgery (sectorectomy and lymphadenectomy) and radiation therapy. Two months after the end of radiotherapy she presented with a 2 mm skin lesion and she was referred for a screening ultrasound. The screening automated breast ultrasound (ABUS) revealed local recurrence and pectoralis metastases, lesions evaluated also by magnetic resonance imaging. The diagnosis was confirmed by the ultrasound-guided biopsy.


Subject(s)
Breast Neoplasms/pathology , Muscle Neoplasms/diagnostic imaging , Muscle Neoplasms/secondary , Neoplasm Recurrence, Local/diagnostic imaging , Pectoralis Muscles/diagnostic imaging , Ultrasonography, Mammary/methods , Adult , Breast Neoplasms/therapy , Fatal Outcome , Female , Humans
9.
Med Ultrason ; 20(3): 385-391, 2018 Aug 30.
Article in English | MEDLINE | ID: mdl-30167594

ABSTRACT

Fibroadenomas (FAs) are the most frequently encountered benign breast lesions in young women and due to the age of the patients, they are usually diagnosed by ultrasound. Although they rarely undergo malignant transformation, the patients remain concerned about the possibility of malignant transformation. The aim of this pictorial essay is to illustrate the appearance of classic and complex fibroadenomas, to discuss the risk factors and to highlight the imaging characteristics that raise the suspicion of malignant transformation. In other words, we try to answer, according to our experience and literature data, to a frequently asked question in daily practice: "Is there any risk thatmy fibroadenoma will become malignant?"


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Cell Transformation, Neoplastic/pathology , Fibroadenoma/diagnostic imaging , Fibroadenoma/pathology , Adult , Aged , Biopsy, Needle , Contrast Media , Female , Humans , Immunohistochemistry , Magnetic Resonance Imaging/methods , Mammography/methods , Middle Aged , Risk Assessment , Sensitivity and Specificity , Ultrasonography, Doppler/methods
10.
Med Ultrason ; 1(1): 95-99, 2018 Feb 04.
Article in English | MEDLINE | ID: mdl-29400375

ABSTRACT

A wide spectrum of breast diseases breast diseases have or exhibit at some point in their natural history a complex cystic aspect. Through the lens of B-mode and Doppler ultrasound with sonoelastographic augmentation, conditions ranging from the utterly benign fibrocystic change to the most intricate encysted or cystically degenerated cancerous lesions, are covered in detail in this review. The aim of this paper is to familiarize the practitioner with the ultrasonographic aspects of complex breast cystic masses and to implement a gradual, strategic approach in the diagnostic algorithm.


Subject(s)
Breast Neoplasms/diagnostic imaging , Fibrocystic Breast Disease/diagnostic imaging , Ultrasonography, Mammary/methods , Breast/diagnostic imaging , Breast/pathology , Breast Neoplasms/pathology , Diagnosis, Differential , Female , Fibrocystic Breast Disease/pathology , Humans
11.
Acta Radiol ; 59(5): 599-605, 2018 May.
Article in English | MEDLINE | ID: mdl-28835111

ABSTRACT

Background High-grade gliomas (HGGs) and brain metastases (BMs) can display similar imaging characteristics on conventional MRI. In HGGs, the peritumoral edema may be infiltrated by the malignant cells, which was not observed in BMs. Purpose To determine whether the apparent diffusion coefficient values could differentiate HGGs from BMs. Material and Methods Fifty-seven patients underwent conventional magnetic resonance imaging (MRI) and diffusion-weighted imaging (DWI) before treatment. The minimum and mean ADC in the enhancing tumor (ADCmin, ADCmean) and the minimum ADC in the peritumoral region (ADCedema) were measured from ADC maps. To determine whether there was a statistical difference between groups, ADC values were compared. A receiver operating characteristic (ROC) curve analysis was used to determine the cutoff ADC value for distinguishing between HGGs and BMs. Results The mean ADCmin values in the intratumoral regions of HGGs were significantly higher than those in BMs. No differences were observed between groups regarding ADCmean values. The mean ADCmin values in the peritumoral edema of HGGs were significantly lower than those in BMs. According to ROC curve analysis, a cutoff value of 1.332 × 10-3 mm2/s for the ADCedema generated the best combination of sensitivity (95%) and specificity (84%) for distinguishing between HGGs and BMs. The same value showed a sensitivity of 95.6% and a specificity of 100% for distinguishing between GBMs and BMs. Conclusion ADC values from DWI were found to distinguish between HGGs and solitary BMs. The peritumoral ADC values are better than the intratumoral ADC values in predicting the tumor type.


Subject(s)
Brain Neoplasms/diagnostic imaging , Brain Neoplasms/secondary , Diffusion Magnetic Resonance Imaging/methods , Glioma/diagnostic imaging , Glioma/pathology , Adult , Aged , Diagnosis, Differential , Female , Humans , Male , Middle Aged , Neoplasm Grading , Retrospective Studies , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...