Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
2.
Pediatr Cardiol ; 2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38353710

ABSTRACT

The number of device implantation procedures has increased in adult patients with congenital heart disease (ACHD). Despite significant improvements in materials and implantation techniques, these patients are exposed to higher risk of device related complications than general population. Herein, we describe our single tertiary referral center experience on transvenous pacemaker (PM) implantation and follow-up in adult patients with moderate and complex congenital heart disease (CHD) as limited data are available on long-term outcome. We considered all adults with moderate and complex CHD aged more than 16 years who underwent transvenous single-chamber and dual-chamber PM implant for sinus node dysfunction or atrioventricular block between January 2013 to December 2022 at our Unit. Seventy-one ACHD patients were included in the study (mean age 38.6 ± 15.2 years, 64% with moderate CHD, 36% with complex CHD). Among 32 patients implanted with a dual chamber PM (DDD PM), 4 devices were reprogrammed in VDD mode, 3 in VVI and 2 in AAI mode during follow-up because of lead dysfunction or permanent atrial arrhythmia. In addition, 26 patients had a single chamber PM (AAI or VVI PM) and 13 patients had single-lead pacing system with a free-floating atrial electrode pair (VDD PM). Just one of 13 single-lead VDD PM was reprogrammed in VVI mode due to a low atrial sensing. In DDD PM group, 10 re-interventions were needed due to lead dysfunction (8 cases) and lead-related infective endocarditis (2 cases). Only 3 patients in the single-lead PM group developed lead dysfunction with 2 re-interventions needed, but no infective endocarditis was reported. The rate of long-term complications is high in moderate and complex ACHD with transvenous PM devices, and it is mainly lead-related. In our experience, the less leads implanted, the less complications will occur. Considering the heterogeneity of the ACHD population, transvenous single-chamber or dual-chamber PM device implantation should always be tailored on the single patient, balancing risks and benefits in this complex population.

3.
J Arrhythm ; 40(1): 150-153, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38333387

ABSTRACT

Conventional nonirrigated catheters cannot be able to create adequate lesions for effective slow pathway modulation in certain cases of pediatric atrioventricular nodal reentrant tachycardia ablation. Irrigated contact force sensing catheters may be considered in pediatric and adolescent patients to obtain a more extensive slow pathway modulation for redo ablation, avoiding dangerous radiofrequency applications close to the compact atrioventricular node or complex left-sided procedures.

4.
Article in English | MEDLINE | ID: mdl-38240394

ABSTRACT

Allergic reactions to components of cardiac implantable electronic devices are rare and often go undiagnosed, which can lead to a misdiagnosis of device infection. Contact allergy to subcutaneous implantable cardioverter defibrillator (S-ICD) is extremely rare. In this report, we present a case of cobalt-related contact allergy in a pediatric patient with Brugada syndrome who underwent S-ICD implantation.

5.
Article in English | MEDLINE | ID: mdl-37878161

ABSTRACT

BACKGROUND: Subcutaneous implantable cardioverter defibrillators (S-ICD) are widely accepted therapy in congenital heart disease (CHD) patients at risk of life-threatening ventricular arrhythmias or sudden cardiac death (SCD) when pacing is not required. Occasionally, pacemaker (PM)-dependent CHD patients will subsequently develop an indication for a cardioverter defibrillator. The use of S-ICD in complex CHD patients who have had already PM devices implanted implies some specific considerations, as the safety for these patients in unknown and recommendations among physicians may vary widely. METHODS: We review the data and studied the indications for S-ICD in complex CHD with previous PM and discuss its usefulness in clinical practice. RESULTS: From a large cohort of 345 patients enrolled in the S-ICD Monaldi care registry, which encompass all the patients implanted in the Monaldi Hospital of Naples, we considered 11 consecutive complex CHD patients (10M/1F aged 40.4 ±18.4 years) who underwent S-ICD implant after a previous PM implant, from February 2015 to October 2022. Mean follow-up was 25.5 ± 22 months. All the patients showed a good compliance to the device system with no complications (infections or skin erosions). CONCLUSIONS: In complex CHD with already implanted PM devices, S-ICD implant appears to be a safe alternative to PM upgrading to transvenous ICD system, avoiding abandoned leads or life-threatening lead extraction. However, there are important issues with regard to testing and programming that need to be addressed at the time of implantation.

7.
J Arrhythm ; 39(4): 653-657, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37560264

ABSTRACT

Limited data are available on the use of irrigated contact force (CF) catheters for radiofrequency (RF) ablation of permanent junctional reciprocating tachycardia (PJRT) in children. We considered five consecutive pediatric patients with diagnosis of PJRT who underwent RF ablation with irrigated CF catheter guided by electroanatomic mapping, obtaining a low number of RF pulses and minimal fluoroscopy exposure. High CF values are not necessary to obtain effective RF lesions and successful ablation.

8.
Int J Cardiovasc Imaging ; 39(9): 1697-1705, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37244886

ABSTRACT

Wolff-Parkinson-White Syndrome (WPW) has been associated with reduced local myocardial deformation, and when left ventricular dysfunction is present, catheter ablation of the accessory pathway may be required, even in asymptomatic patients. We aimed to evaluate the diagnostic value of non-invasive myocardial work in predicting subtle abnormalities in myocardial performance in children with WPW.Seventy-five paediatric patients (age 8.7 ± 3.5 years) were retrospectively recruited for the study: 25 cases with manifest WPW and 50 age- and sex- matched controls (CTR). Global myocardial work index (MWI) was measured as the area of the left ventricle (LV) pressure-strain loops. From MWI, global Myocardial Constructive Work (MCW), Wasted Work (MWW), and Work Efficiency (MWE) were estimated. In addition, standard echocardiographic parameters of LV function were evaluated. Despite normal LV ejection fraction (EF) and global longitudinal strain (GLS), children with WPW had worse MWI, MCW, MWW, and MWE. At multivariate analysis, MWI and MCW were associated with GLS and systolic blood pressure, and QRS was the best independent predictor of low MWE and MWW. In particular, a QRS > 110 ms showed good sensitivity and specificity for worse MWE and MWW values. In children with WPW, myocardial work indices were found significantly reduced, even in the presence of normal LV EF and GLS. This study supports the systematic use of myocardial work during the follow-up of paediatric patients with WPW. Myocardial work analysis may represent a sensitive measure of LV performance and aid in decision-making.


Subject(s)
Wolff-Parkinson-White Syndrome , Humans , Child , Child, Preschool , Wolff-Parkinson-White Syndrome/diagnostic imaging , Wolff-Parkinson-White Syndrome/surgery , Retrospective Studies , Predictive Value of Tests , Myocardium , Echocardiography , Ventricular Function, Left , Stroke Volume
9.
Pediatr Cardiol ; 44(5): 1040-1049, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37093256

ABSTRACT

Atrioventricular reentrant tachycardia (AVRT) is the most common form of supraventricular tachycardia in newborns. AVRT is sometimes refractory to conventional antiarrhythmic therapy. We describe our experience about the use of the triple combination of flecainide + propranolol + amiodarone as third-line regimen for refractory and recurrent AVRT in newborns. We considered a series of 14 patients who had failed both first-line and second-line therapy and were treated using the combination of flecainide + propranolol + amiodarone. Transoesophageal electrophysiologic study (TES) was performed to test the effectiveness of medical therapy during hospitalization and to try to reduce the amount of therapy, after amiodarone wash-out, before 1 year of age. TES was repeated at 1 year of age to test the spontaneous resolution of the arrhythmia after treatment discontinuation. Rhythm control was achieved in all 14 patients. At a mean age of 9.3 ± 2 months, AVRT was not inducible by TES in 11/12 amiodarone-free patients. At a mean age of 14.1 ± 3 months, AVRT was still inducible in 7/12 patients after interrupting the entire antiarrhythmic therapy (58.3%). Triple combination was effective as third-line option to suppress AVRT refractory to single and double antiarrhythmic therapy, with no significant adverse events. Our experience suggests that triple therapy could be maintained for a short-term treatment, discontinuing amiodarone before 1 year of age to avoid long-term side effects. Newborns who needed triple therapy appear to have a lower chance of accessory pathway disappearance at 1 year of age. TES could be useful for risk stratification of recurrences at the time of drug discontinuation in infants considered to be at higher risk of recurrent AVRT.


Subject(s)
Amiodarone , Tachycardia, Atrioventricular Nodal Reentry , Tachycardia, Supraventricular , Infant, Newborn , Infant , Humans , Flecainide/therapeutic use , Propranolol/therapeutic use , Anti-Arrhythmia Agents/therapeutic use , Tachycardia, Supraventricular/drug therapy , Amiodarone/therapeutic use
10.
Cardiol Young ; 33(12): 2574-2580, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37038838

ABSTRACT

BACKGROUND: Long-term data on COVID-19 vaccine safety, immunogenicity, and acceptance in adults with CHD are lacking. METHODS: This is a prospective study including adults with CHD patients undergoing COVID-19 vaccination from January 2021 to June 2022. Data on adverse events, antispike IgG titre, previous or subsequent COVID-19 infection, booster doses, and patients' attitude towards vaccination were collected. RESULTS: Four hundred and ninety CHD patients (36 ± 13 years, 53% male, 94% with moderate/complex defects) were prospectively included: 433 (88%) received a Pfizer-BioNTech mRNA vaccine, 31 (6%) Moderna mRNA vaccine, 23 (5%) AstraZeneca-Oxford ChAdOx1 nCov-19 vaccine, and 3 (0.6%) Janssen Vaccine; 310 (63%) received a booster dose. Median follow-up after vaccination was 1.53 [1.41-1.58] years. No major adverse event was reported. Eighty-two fully vaccinated patients contracted COVID-19 during follow-up after a median of 5.4 [4.3-6.5] months from the last dose. One patient with Ebstein's disease died from severe COVID-19. Symptoms' duration in patients who tested positive after vaccination was significantly shorter than in the group tested positive before vaccination (5.5 [3-8] versus 9 [2.2-15] days, p = 0.04). Median antispike IgG titre measured in 280 individuals (57%) at a median of 1.4 [0.7-3.3] months from the last dose was 2381 [901-8307] BAU/ml. Sixty patients (12%) also showed positive antinucleocapsid antibodies, demonstrating previous SARS-COV2 exposure. Twenty-nine percent appeared to have concerns regarding vaccine safety and 42% reported fearing potential effects of the vaccine on their cardiac disease before discussing with their CHD cardiologist. CONCLUSION: COVID-19 vaccines appear safe in the mid-term follow-up in adults with CHD with satisfactory immunogenicity and reduction of symptoms' duration in case of infection.


Subject(s)
COVID-19 Vaccines , COVID-19 , Adult , Humans , Male , Female , COVID-19 Vaccines/adverse effects , Prospective Studies , ChAdOx1 nCoV-19 , Follow-Up Studies , RNA, Viral , mRNA Vaccines , COVID-19/epidemiology , COVID-19/prevention & control , SARS-CoV-2 , Vaccination , Immunoglobulin G
11.
Pediatr Cardiol ; 44(5): 1068-1075, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36576525

ABSTRACT

Implantable loop recorders (ILRs) are effective tools for detecting arrhythmias by long-term continuous heart rhythm monitoring. Benefits have been demonstrated even in pediatric patients. ILR with a long sensing vector has recently been designed to improve signal quality in terms of P wave visibility and R wave amplitude. However, there are no data on its use in pediatric patients. We considered a series of pediatric patients implanted with a long sensing vector ILR. Sensing performance, including R wave amplitude and P wave visibility, device-related complications, and diagnostic yield were collected. During follow-up, each patient guided by his/her parents/guardians was also asked to complete a brief questionnaire to assess patient acceptability of the device. Twenty-five consecutive pediatric patients (mean age 11.3 ± 3.5 years, 72% male) were enrolled. The insertion success rate was 100% on the first attempt with no complications. The median amplitude of the R wave was 1.15 mV (interquartile range, 1.01-1.42) with no significant differences between patients aged ≤ or > 10 years (p = 0.726) and between female and male (p = 0.483). P wave was classified as 'always visible' in 24/25 patients (96%). ILR was generally well accepted and tolerated by all involved patients. During a median follow-up of 297 days (117-317), we achieved in 5 patients a correlation between symptoms and rhythm disorders (20%) and ruled out significant arrhythmias in 6 symptomatic children (24%). Long sensing vector ILR showed to be well accepted, with good signal quality and an excellent safety profile even in pediatric patients.


Subject(s)
Arrhythmias, Cardiac , Electrocardiography, Ambulatory , Humans , Child , Male , Female , Adolescent , Electrodes, Implanted/adverse effects , Arrhythmias, Cardiac/etiology , Surveys and Questionnaires
13.
Monaldi Arch Chest Dis ; 93(1)2022 Aug 05.
Article in English | MEDLINE | ID: mdl-35929642

ABSTRACT

Placement of traditional transvenous implantable cardioverter defibrillator (ICD) system in low-weight children is often difficult because of their vessel size, the elevated risk of lead malfunction and failure, children's growth and various anatomic constraints, creating the need for alternative solutions. Subcutaneous array leads combined with an abdominally placed ICD device can minimize the surgical approach. In this case series, we analyse the data behind indications for subcutaneous finger cardioverter defibrillator (SFCD) and discuss the preliminary clinical experience in low-weight children. We considered 4 consecutive children (mean age 3.9 years, range 3-5.5 years, mean body weight 17.6 Kg, range 14-23 Kg) who underwent SFCD implant from April 2016 to August 2020. All patients showed a good compliance to the device system with no complications (infections or skin erosions). No patients experienced in the observation period (mean time 44.5±21.5 months) sustained ventricular arrhythmias requiring shocks. No inappropriate shocks released by the device occurred. No significant changes were observed in LET (lowest energy tested) performed around 24 months of follow-up. All patients showed a good compliance and stable atrio-ventricular sensing and pacing thresholds. In smaller children in whom a transvenous approach is not feasible or not possible for anatomic reasons, the SFCD appears to be a safe method to prevent SCD with little surgical trauma and preservation of an intact vascular system, providing an adequate bridge to transvenous ICD or subcutaneous ICD implant late in the life.


Subject(s)
Defibrillators, Implantable , Electric Countershock , Humans , Child , Child, Preschool , Electric Countershock/adverse effects , Arrhythmias, Cardiac , Defibrillators, Implantable/adverse effects , Electrocardiography , Time Factors , Treatment Outcome , Death, Sudden, Cardiac/prevention & control
14.
Indian Pacing Electrophysiol J ; 22(5): 217-222, 2022.
Article in English | MEDLINE | ID: mdl-35777690

ABSTRACT

BACKGROUND: Wearable cardioverter-defibrillators (WCDs) are currently used in patients at temporarily heightened risk for sudden cardiac death (SCD) who are temporarily unable to receive an implantable cardioverter-defibrillator (ICD). WCD can safely record and terminate life-threatening arrhythmias through a non-invasive electrode-based system. The current clinical indications for WCD use are varied and keep evolving as experience with this technology increases. METHODS: We reviewed and explored the data behind indications for WCD use and discuss its usefulness in congenital heart disease (CHD) patients. RESULTS: We considered 8 consecutive patients (mean age 35.25 years, range 18-51 years, average duration of WCD use 4 months, range 3-6 months) with complex CHD, in which a WCD was used between June 2018 and January 2022. No sustained ventricular arrhythmias requiring shocks were recorded in the observation period. No inappropriate shocks were recorded. All the patients showed a good compliance and a very high mean wear time per day (21.2 ± 1 h a day). Four patients implanted a permanent device (3 CRT-D, 1 ICD), three underwent cardiac surgery at the end of the WCD period and one is still on the waiting list for the operation. CONCLUSIONS: Larger trial could confirm the possible conceivable benefit from an extended use of the WCD in certain populations with complex CHD as in our case series, especially in patients with life-treating ventricular arrhythmias waiting for surgery for residual cardiac defects or in the early phases following the surgical/hemodynamic interventions, patients with tachycardiomyopathy expected to improve after the arrhythmias are removed and patients awaiting implantation of an ICD at high risk due to active infection.

15.
Pacing Clin Electrophysiol ; 45(9): 1062-1064, 2022 09.
Article in English | MEDLINE | ID: mdl-35906933

ABSTRACT

Twiddler's syndrome is a rare cause of pacemaker lead dislodgement. We present the case of a 49-year-old male patient with Down's syndrome implanted with a dual chamber pacemaker showing high ventricular impedance, no sensing, and complete loss of capture for both leads at the 3-month follow-up due to Twiddler Syndrome. The dislocated device was removed, and an endocardial leadless pacing system was implanted.


Subject(s)
Pacemaker, Artificial , Equipment Failure , Heart Ventricles , Humans , Male , Middle Aged , Prostheses and Implants , Syndrome
16.
J Arrhythm ; 38(2): 213-220, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35387134

ABSTRACT

Aim: Remote monitoring (RM) of implantable cardiac devices has enabled continuous surveillance of atrial high rate episodes (AHREs) with well-recognized clinical benefits. We aimed to add evidence on the role of the RM as compared to conventional follow-up by investigating the interval from AHRE onset to physician's evaluation and reaction time in actionable episodes. Methods and Results: A total of 97 dual-chamber pacemaker recipients were followed with RM (RM-ON group; N = 64) or conventional in-office visits (RM-OFF group; N = 33) for 18 months. In-office visits were scheduled at 1, 6, 12, and 18 months in the RM-OFF group and at 1 and 18 months in the RM-ON group. The overall AHRE rate was 1.98 per patient-year (95% confidence interval [CI], 1.76-2.20) with no difference between the two groups (RM-ON vs. RM-OFF weighted-HR, 0.88; CI, 0.36-2.13; p = .78). In the RM-ON group, 100% AHREs evaluated within 11 days from onset, and within 202 days in the RM-OFF group, with a median evaluation delay 79 days shorter in the RM-ON group versus the RM-OFF group (p < .0001). Therapy adjustment in actionable AHREs occurred 77 days earlier in the RM-ON group versus the control group (p < .001). In the RM-ON group, there were 50% less in-office visits as compared to the RM-OFF group (p < .001). Conclusions: In our pacemaker population with no history of atrial fibrillation, RM allowed significant reduction of AHRE evaluation delay and prompted treatment of actionable episodes as compared to biannual in-office visit schedule.

17.
Indian Pacing Electrophysiol J ; 22(2): 108-111, 2022.
Article in English | MEDLINE | ID: mdl-35063627

ABSTRACT

Cardiac resynchronization therapy-defibrillator (CRT-D) implantation is a therapeutic option for adult patients with congenital heart disease (CHD), bundle branch block, reduced ejection fraction and symptoms of heart failure. A new implantation approach guided by the electroanatomic mapping (EAM) has been developed to overcome some issues of the standard technique: non-responder patients, high x-ray exposure and use of iodinated contrast medium for coronary sinus angiography. This approach has not been previously described in the CHD population. We report a case of EAM-guided approach for CRT-D implantation in a young adult patient with CHD.

18.
JACC Case Rep ; 3(5): 736-739, 2021 May.
Article in English | MEDLINE | ID: mdl-34317616

ABSTRACT

Obstruction of the superior vena cava represents an under-recognized cause of chylothorax in the adult population. Our case report describes the successful conservative management of chylothorax due to bilateral superior vena cava obstruction in an adult patient with complex congenital heart disease. (Level of Difficulty: Beginner.).

SELECTION OF CITATIONS