Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
G Chir ; 36(5): 201-4, 2015.
Article in English | MEDLINE | ID: mdl-26712255

ABSTRACT

AIM: To assess the diagnostic accuracy of specimen ultrasound (US) for predicting resection margin status in women undergoing breast conserving therapy for US-detected cancer, having the histological findings as the reference standard. PATIENTS AND METHODS: A total of 132 consecutive patients (age range, 34-87 years; mean, 51 years) underwent breast-conserving surgery for US-detected invasive breast cancer. All surgical specimens underwent US examination. The presence of lesion within the specimen and its distance from the specimen margins were assessed considering a threshold distance between the lesion and specimen margins of 10 mm. US findings were then compared with the pathological ones and specimen US. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) for predicting histological margin status were evaluated, having the histological findings as the reference standard. RESULTS: The histological examination detected invasive ductal carcinoma in 96/132 (73%) cases, invasive lobular carcinoma in 32/132 (24%), mucinous carcinoma in 4/132 (3%). The pathological margin analysis revealed 96/132 (73%) negative margins and 36 (27%) close/positive margins. US examination detected all 132 breast lesions within the surgical specimens. 110 (83%) negative margins and 22 (17%) positive margins were found on US. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 44%, 94%, 80%, 73% and 82%, respectively, were found for specimen US. CONCLUSIONS: Specimen US represents a time and cost saving imaging tool for evaluating the presence of US detected-breast lesion within surgical specimen and for predicting the histological margin status.


Subject(s)
Adenocarcinoma, Mucinous/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Carcinoma, Ductal, Breast/diagnostic imaging , Carcinoma, Lobular/diagnostic imaging , Mastectomy, Segmental , Adenocarcinoma, Mucinous/epidemiology , Adenocarcinoma, Mucinous/surgery , Adult , Aged , Aged, 80 and over , Breast Neoplasms/epidemiology , Carcinoma, Ductal, Breast/epidemiology , Carcinoma, Ductal, Breast/surgery , Carcinoma, Lobular/epidemiology , Carcinoma, Lobular/surgery , Female , Humans , Italy/epidemiology , Mastectomy, Segmental/methods , Middle Aged , Predictive Value of Tests , Sensitivity and Specificity , Treatment Outcome , Ultrasonography
2.
G Chir ; 35(11-12): 274-8, 2014.
Article in English | MEDLINE | ID: mdl-25644728

ABSTRACT

AIM: To evaluate the incidence of Poly Implant Prosthése (PIP) rupture as assessed by magnetic resonance imaging (MRI), the prevalence of the detected signs and the potential correlation with breast carcinoma. PATIENTS AND METHODS: 67 patients with silicone breast implants and clinical indications for breast MRI were evaluated for a total of 125 implants: 40 (32%) PIP in 21 patients and 85 non-PIP in 46 patients (68%), the latest considered as control group. A 1.5-T MR imaging device was used in order to assess implant integrity with dedicated sequences and in 6 cases a dynamic study was performed for characterizing breast lesions. Two radiologists with more than 5 years' experience in the field of MRI evaluated in consensus all MR images searching for the presence of clear signs of intra or extra-capsular implant rupture. RESULTS: 20/40 (50%) PIP implants presented signs of intra-capsular rupture: linguine sign in 20 cases (100%), tear-drop sign in 6 (30%). In 12/20 cases (60%), MRI signs of extra-capsular rupture were detected. In the control group, an intra-capsular rupture was diagnosed in 12/85 cases (14%) associated with extra-capsular one in 5/12 cases (42%). Among the six cases with suspected breast lesions, in 2/21 patients with PIP implants (10%) a breast carcinoma was diagnosed (mucinous carcinoma, n=1; invasive ductal carcinoma, n=1). In 4/46 patients (9%) with non-PIP implants, an invasive ductal carcinoma was diagnosed. CONCLUSION: The rupture rate of PIP breast implants is significantly higher than non-PIP (50% vs 14%). MRI represents the most accurate imaging tool for evaluating breast prostheses and the linguine sign is the most common MRI sign to be searched. The incidence of breast carcinoma does not significantly differ between the PIP and non-PIP implants and a direct correlation with breast cancer can not been demonstrated.


Subject(s)
Breast Implants , Breast Neoplasms/diagnosis , Breast Neoplasms/epidemiology , Magnetic Resonance Imaging , Prosthesis Failure , Adult , Breast Neoplasms/etiology , Female , Humans , Middle Aged , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...