Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 78
Filter
1.
Clin Interv Aging ; 19: 655-664, 2024.
Article in English | MEDLINE | ID: mdl-38706637

ABSTRACT

Purpose: Aim of the present study was to evaluate whether monitoring direct oral anticoagulant (DOAC) levels may improve management of anticoagulated patients who need surgery for hip fracture. Patients and Methods: A total of 147 out of 2231 (7.7%) patients with hip fracture admitted to a tertiary teaching hospital were on DOACs (group A), whereas 206 patients matched for age, sex, and type of fracture not on anticoagulant or P2Y12 platelet inhibitors were considered as control group (group B). Patients on DOACs were divided into two subgroups: A1 in which intervention was scheduled in relation to the last drug intake according to current guidelines, and A2 included patients in whom time of surgery (TTS) was defined according to DOAC levels. Neuraxial anesthesia was considered with DOAC levels <30 ng/mL, general anesthesia for levels in the range 30-50 ng/mL. Results and conclusions: TTS was significantly lower in controls than in DOAC patients: surgery within 48 hours was performed in 80.6% of group B versus 51% in group A (p<0.0001). In A2, 41 patients underwent surgery within 48 hours (56%) in comparison to 32 A1 patients (45.1%; p=0.03). TTS and length of hospitalization were on average 1 day lower in patients with assay of DOAC levels. Finally, 35/39 (89%) patients with DOAC levels <50 ng/mL had surgery within 48 hours (26 under neuraxial anesthesia, without any neurological complication, and 13 in general anesthesia). Conclusion: DOAC assay in patients with hip fracture may be useful for correct definition of time to surgery, particularly in patients who are candidates for neuraxial anesthesia. Two-thirds of patients with DOAC levels <50 ng/mL at 48 hours from last drug intake underwent uneventful neuraxial anesthesia, saving at least 24 hours in comparison to guidelines.


Subject(s)
Anticoagulants , Drug Monitoring , Hip Fractures , Humans , Hip Fractures/surgery , Female , Male , Aged , Aged, 80 and over , Anticoagulants/administration & dosage , Drug Monitoring/methods , Administration, Oral , Preoperative Care/methods , Length of Stay , Anesthesia, General
2.
Ann Jt ; 9: 20, 2024.
Article in English | MEDLINE | ID: mdl-38690077

ABSTRACT

Background and Objective: Proximal femoral replacement due to revision hip arthroplasty or catastrophic proximal femur fracture fixation failures with considerable proximal femur bone loss can lead to a substantial loss of function of the soft tissue around the hip and the abductor muscles in particular. Surgical techniques of gluteus medius repair and/or abductor mechanism reattachment/reconstruction are widely debated in the literature, but it is quite rarely dealt with in the context of megaprosthesis and femoral reconstruction, particularly in non-oncologic patients. The aim of this study is to present a narrative review of the literature on techniques for abductor reattachment in proximal femoral replacement for non-oncological reconstructions. Methods: MEDLINE, Embase, and Cochrane databases were searched by two researchers independently from inception until February 1st, 2023 (923 for MEDLINE and 963 for Embase; Cochrane is a composite of multiple databases and thus does not report a standard inception date). Articles examining proximal femoral reconstruction with megaprosthesis or allograft prosthesis were included. Studies concerning cadaver and oncologic patients were excluded. If the researchers failed to find an agreement on whether to include a study, the senior researcher would make a final decision in such cases. Data were extracted and stored, and qualitative synthesis was performed. Key Content and Findings: A total of 1,157 articles from MEDLINE, 11,187 articles from Embase, and 0 articles from Cochrane were identified. Of 12,344 articles, the structured screening process revealed 10 eligible trials. Four different types of abductor musculature reconstruction/reinsertion were identified. Conclusions: Multiple and complex revision hip arthroplasties as well as multiple surgical procedures for proximal femur fracture fixations failures may have a great impact on proximal femur bone stock condition and soft tissue preservation requiring the use of a proximal femur megaprosthesis. In such cases, the abductor mechanism reconstruction and/or reattachment is achievable with different techniques that can be resumed in four different groups: direct suture to the prosthesis, trochanteric sleeve osteotomy, muscle-to-muscle suture, and synthetic tube augmentation suture.

3.
J Knee Surg ; 2024 May 24.
Article in English | MEDLINE | ID: mdl-38677294

ABSTRACT

Revision anterior cruciate ligament reconstruction (ACLR) is a challenging surgery occurring in 3 to 24% of primary reconstructions. A meticulous planning to study the precise size and location of both femoral and tibial bone tunnels is mandatory. The aim of the study was to evaluate the intra- and interoperator differences in the decision-making process between experienced surgeons after they were asked to make preoperative planning for ACL revision reconstruction with the use of both the computed tomography (CT) scan and a three-dimensional (3D)-printed model of the knee. Data collected from 23 consecutive patients undergoing revision of ACLR for graft failure at a single institute between September 2018 and February 2020 were prospectively reviewed. The double-blinded collected data were presented to three board-certificate attending surgeons. Surgeons were asked to decide whether to perform one-stage or two-stage revision ACLR based on the evaluation of the CT scan images and the 3D-printed custom-made models at two different rounds, T0 and T1, respectively, 7 days apart one from the other. Interoperator consensus following technical mistake was 52% at T0 and 56% at T1 using the CT scans, meanwhile concordance was 95% at T0 and 94% at T1 using the 3D models. Concordance between surgeons following new knee injury was 66% at T0 and 70% at T1 using CT scans, while concordance was 96% both at T0 and T1 using 3D models. Intraoperative variability using 3D models was extremely low: concordance at T0 and T1 was 98%. McNemar test showed a statistical significance in the use of 3D model for preoperative planning (p < 0.005). 3D-printed model reliability resulted to be higher compared with CT as intraoperator surgery technique selection was not modified throughout time from T0 to T1 (p < 0.005). The use of 3D-printed models had the most impact when evaluating femoral and tibial tunnels, resulting to be a useful instrument during preoperative planning of revision ACLR between attending surgeons with medium-high workflow.

4.
Eur J Orthop Surg Traumatol ; 34(4): 2121-2128, 2024 May.
Article in English | MEDLINE | ID: mdl-38555541

ABSTRACT

BACKGROUND AND PURPOSE: The aim of this study was to evaluate whether this system is associated with a reduced rate of failure and complications in patients treated for proximal femoral fractures with intramedullary nailing. MATERIALS AND METHODS: 742 Patients with AO-OTA 31-A intertrochanteric fractures were enrolled at a single Institution. Functional evaluation was assessed through the Functional Independence Measure (FIM™) instrument and Parker's New Mobility Score (NMS). Radiological follow-up included the degree of the reduction according to the Baumgartner criteria, the Tip-Apex Distance, and the shortening of the telescoping screws and its lateral protrusion. RESULTS: Pre-operative mean FIM™ and NMS were 4.3 (range 1-9) and 98.7 (range 22-126), respectively. At the 12-month follow-up the average FIM™ and NMS were 95.3 (range 22-126) and 3.7 (range 1-9), respectively. Mean shortening of the lag screws was 4.3 mm (range 1-8) and mean lateral protrusion was 1.7 mm (range 0-3). 3 Cases (0.70%) of non-consolidation requiring reoperation were recorded. 1 Case (0.24%) of these cases was also characterized by nail breakage. No case of cut-out has been reported at our follow-up. CONCLUSIONS: This dual telescoping nail system is effective and safe. The sliding of the telescoping screws within the barrel is able to decrease strain from the femoral head during weight bearing reducing the risk of cut-out.


Subject(s)
Bone Nails , Bone Screws , Fracture Fixation, Intramedullary , Hip Fractures , Humans , Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/adverse effects , Male , Female , Aged , Hip Fractures/surgery , Hip Fractures/diagnostic imaging , Retrospective Studies , Aged, 80 and over , Middle Aged , Treatment Outcome , Radiography , Adult , Postoperative Complications/prevention & control , Postoperative Complications/etiology
5.
Eur J Orthop Surg Traumatol ; 34(1): 479-487, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37624410

ABSTRACT

PURPOSE: The aim of this study was to evaluate the relationship between the Löwenstein Lateral view and the True Lateral view for the positioning of the cephalic hip screw, through a cadaveric study. MATERIALS AND METHODS: We placed two Kirschner wires in eight femur specimens using an Antero-Posterior view, Löwenstein Lateral view and True Lateral view. The distances between the Kirschner wires and the anterior, posterior, superior and inferior cortex were measured in all projections. The head of the femur was then sectioned, and the same macroscopic distances were measured. Finally, we could calculate the accuracy of the two radiographic lateral projections. RESULTS: When the Kirschner wire was placed in the center of the head using the Antero-Posterior and the True Lateral view, the accuracy of Antero-Posterior view was 0.9705 while the accuracy of True Lateral view and Löwenstein Lateral view was 1.1479 and 1.1584, respectively. When the Kirschner wire was placed superior on the Antero-Posterior and centrally on the True Lateral view, the accuracy of Antero-Posterior view was 0.9930 while the accuracy of True Lateral view and Löwenstein Lateral view was 1.1159 and 0.7224, respectively. CONCLUSION: When the Kirschner wire was positioned proximal in Antero-Posterior view and central in True Lateral view, only the True Lateral view showed high accuracy.


Subject(s)
Femoral Fractures , Humans , Femoral Fractures/surgery , Bone Screws , Femur/surgery , Lower Extremity , Cadaver , Fracture Fixation, Internal
6.
Arthrosc Tech ; 12(11): e2093-e2098, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38094942

ABSTRACT

Posterior cruciate ligament ruptures account for nearly 20% of knee ligament lesions. These may be either isolated or occur as part of multiligament injuries. In most of the cases, conservative treatment is recommended, but when operative treatment is required, this is technically demanding. Several posterior cruciate ligament reconstructive techniques have been described, but some concerns still remain regarding graft choice, tunnels position, visualization of the posterior compartment and graft fixation. We describe an arthroscopic all-inside technique using a single-bundle autologous quadriceps tendon with patellar bone block.

7.
J Clin Med ; 12(13)2023 Jun 28.
Article in English | MEDLINE | ID: mdl-37445391

ABSTRACT

(1) Background: Total Knee Arthroplasty (TKA) in patient with haemophilia (PWH) has usually been performed with the use of cobalt-chrome femoral and titanium tibial components, coupled with standard polyethylene (PE) inserts. The aim of this retrospective study was to evaluate the long-term outcomes and survival rates of TKA in a series of consecutive PWH affected by severe knee arthropathy at a single institution. (2) Methods: We followed 65 patients undergoing 91 TKA, implanted using the same implant, characterized by an oxidized zirconium femoral component, coupled with a titanium tibial component, and a highly crosslinked PE. At 1, 6, and 12 months; then every year for 5 years; and finally, every other 3 years, all patients were scored for pain (VAS), function (HJHS; KSS), ROM, and radiographic changes. Kaplan-Meier survivorship curves were used to calculate the implant survival rates. (3) Results: The mean follow-up was 12.3 years (4.2-20.6). All clinical and functional scores improved significantly from preoperatively to the latest follow-up (VAS: from 6.9 to 1.3; HJHS: from 13.4 to 1.9; KSS: from 19.4 to 79; ROM: from 42.4° to 83.6°). The overall survivorship of the implants was 97.5% at the latest follow-up. (4) Conclusions: The present series showed a high survival rate of specific implants potentially linked to the choice of an oxidized zirconium coupled with a highly crosslinked PE. We promote the use of modern implants in these patients in order to ensure long-lasting positive outcomes.

8.
Geriatr Orthop Surg Rehabil ; 14: 21514593231170844, 2023.
Article in English | MEDLINE | ID: mdl-37162810

ABSTRACT

Introduction: Total hip arthroplasty (THA) performed for femoral neck fractures (FNFs) is becoming a more frequent treatment in the active elderly population. Since there is limited research available presenting clinical outcomes after THA using the anterior-based muscle sparing (ABMS) approach, the aim of this study was to compare this surgical approach to the direct lateral (DL) approach in patients treated by THA for FNFs. Materials and Methods: We retrospectively reviewed the data prospectively collected as a part of our "Hip Fracture Unit" and included 163 patients who underwent THA from January 2016 to January 2019 for acute displaced FNFs. Results: A total of 132 patients who completed a minimum 2-years follow up (69 in the ABMS group and 63 in DL group) were included. The ABMS group demonstrated significantly shorter time to reach milestone for hospital discharge (1.5 Days vs 2.1 days, P = .018), while no statistically significant differences were detected in peri-operative complications. At 3 months, the timed up and go test, the Harris Hip Score (HHS) and the Oxford ip Score (OHS) were significantly better (P = .024, .032 and .034, respectively) in the ABMS group compared to the DL group. No differences were found in functional outcomes (HHS and OHS) nor in complication rate at 6, 12 and 24 months. Discussion: This is one of the first studies to analyze functional results of THA performed for FNFs through an ABMS approach. Results are in line with those already present in the Literature. Conclusion: ABMS approach allows earlier mobilization and better early functional outcomes, compared to DL approach, in patients undergoing THA for acute displaced FNF. No differences are found after 6 months in functional results and complications rate.

9.
Biomedicines ; 11(4)2023 Mar 27.
Article in English | MEDLINE | ID: mdl-37189637

ABSTRACT

Parathyroid hormone (PTH) is a hormone secreted by the parathyroid glands. Despite its well-known characterized anabolic and catabolic actions on the skeleton, the in vitro effects of PTH on skeletal muscle cells are limited and generally performed on animal models. The aim of this study was to evaluate the effects of a short impulse of PTH (1-84) on the proliferation and the differentiation of skeletal muscle satellite cells isolated from human biopsies. The cells were exposed for 30 min to different concentrations of PTH (1-84), from 10-6 mol/L to 10-12 mol/L. ELISA was used to assay cAMP and the myosin heavy-chain (MHC) protein. The proliferation was assayed by BrdU and the differentiation by RealTime-qPCR. A statistical analysis was performed by ANOVA followed by Bonferroni's test. No significant variations in cAMP and the proliferation were detected in the isolated cells treated with PTH. On the other hand, 10-7 mol/L PTH on differentiated myotubes has shown significant increases in cAMP (p ≤ 0.05), in the expression of myogenic differentiation genes (p ≤ 0.001), and in the MHC protein (p ≤ 0.01) vs. untreated controls. This work demonstrates for the first time the in vitro effects of PTH (1-84) on human skeletal muscle cells and it opens new fields of investigation in muscle pathophysiology.

11.
J Exp Orthop ; 10(1): 32, 2023 Mar 24.
Article in English | MEDLINE | ID: mdl-36961581

ABSTRACT

PURPOSE: Robotic-assisted surgery has been recently introduced to improve biomechanical restoration, and thus better clinical and functional outcomes, after knee joint arthroplasty operations. Robotic-assisted uni-compartmental knee arthroplasty (UKA) aims indeed to improve surgical bone resection and alignment accuracy, optimized component positioning and knee balancing, relying on a series of calibration measurements performed during the surgery. These advantages focus therefore on improving the reproducibility of UKA surgeries, reducing (if not eliminating) eventual differences among high- and low-volume surgeons. The purpose of this study is to investigate and quantify the reproducibility of in-vivo measurements performed with a robotic system: the intra- and inter-observer variability of a series of measurements was therefore analyzed and compared among differently experienced operators. METHODS: Five patients were analyzed and underwent robotic-assisted UKA using a semi-active robotic system. Three different observers with different experience levels were involved to independently perform the measurements of two parameters of the preoperative knee (Hip-Knee-Ankle angle [HKAa], Internal-External Rotation) at different degrees of knee flexion. Inter-observer and intra-observer comparisons were performed. RESULTS: The average variability in the measurements obtained from the intra-observer and inter-observer comparisons were always < 0.68° for HKAa and < 2.59° for internal-external rotation, and the ICCs showed excellent agreement (> 0.75) for most cases and good agreement (> 0.60) in the remaining ones. CONCLUSION: This study demonstrated high reproducibility of the measurements obtainable in clinical environment with the robotic system. The inter-observer results furthermore showed that the level of confidence with the robotic system is not significantly influencing the measurement.

12.
J Arthroplasty ; 38(9): 1773-1778, 2023 09.
Article in English | MEDLINE | ID: mdl-36822447

ABSTRACT

BACKGROUND: Hip hemiarthroplasty dislocation is a devastating complication. Among other preoperative risk factors, acetabular morphology has been rarely studied. The purpose of the study was to evaluate the influence of preoperative native acetabular morphology on hemiarthroplasty dislocation. METHODS: We retrospectively reviewed 867 patients who underwent hip hemiarthroplasty for femoral neck fracture between January 1, 2014 and January 1, 2019. The 380 included patients were treated with an anterior-based muscle-sparing approach. The central-edge angle (CEA) and acetabular depth-to-width ratio (ADWR) of the fractured hip were measured preoperatively on the anteroposterior pelvic view. Receiver operating characteristic curves were performed to analyze the optimal cutoff for CEA and ADWR. Hemiarthroplasty dislocation occurred in 18 patients (4.7%), and the remaining 362 patients were used as the control group. RESULTS: No significant differences in terms of sex, age, dementia, neuromuscular disease, and body mass index were found between the 2 groups. The 18 patients who had a hip dislocation had significantly smaller mean CEA than the control group (P = .0001) (mean 36.1 ± 7.5° and 43.2 ± 5.6°, respectively) as well as ADWR (mean 34 ± 6 versus 37 ± 4, respectively) (P = .001). Using the receiver operating characteristic analysis, we report significant cutoffs of 38.5° for CEA (P = .0001) and 34.5 for the ADWR (P = .017). CONCLUSION: Higher rates of hemiarthroplasty dislocation were observed in patients who had a preoperative CEA of less than 38.5° and an ADWR of less than 34.5. Patients who have preoperative acetabular morphological risk factors for dislocation might be better candidates for a total hip arthroplasty.


Subject(s)
Arthroplasty, Replacement, Hip , Femoral Neck Fractures , Hemiarthroplasty , Hip Dislocation , Joint Dislocations , Humans , Aged , Retrospective Studies , Hemiarthroplasty/adverse effects , Acetabulum/surgery , Joint Dislocations/epidemiology , Joint Dislocations/etiology , Joint Dislocations/surgery , Femoral Neck Fractures/surgery , Femoral Neck Fractures/complications , Hip Dislocation/epidemiology , Hip Dislocation/etiology , Hip Dislocation/surgery , Arthroplasty, Replacement, Hip/adverse effects
13.
J Med Case Rep ; 16(1): 457, 2022 Dec 10.
Article in English | MEDLINE | ID: mdl-36494697

ABSTRACT

BACKGROUND: The synovial chondromatosis is an uncommon proliferative metaplastic process of the synovial cells that can develop in any synovial joint. An isolated primary chondromatosis of the posterior compartment of the knee is uncommon and few cases are reported in literature. Our purpose is to describe a rare case of primary chondromatosis of the knee posterior compartment and report the arthroscopic loose bodies excision through a difficult posteromedial portal, avoiding the use of the accessory posterior portal, most commonly reported for approaching this disease. CASE PRESENTATION: We report a rare case of a 35-year-old Caucasian male patient with diagnosis of chondromatosis of the posterior knee compartment. The radiographs showed multiple loose bodies of the posterior compartment. The MRI revealed minimal synovial hypertrophy areas, multiple osteophytes in the intercondylar notch, and loose bodies in the posteromedial compartment. The CT allowed us to assess the bony structures, the morphology of the intercondylar notch, and the presence osteophytes of the medial and lateral femoral condyles. The CT images were crucial to plan how to reach the posterior compartments of the knee through a trans-notch passage. The patient underwent arthroscopic surgery using anteromedial, anterolateral, and posteromedial portals. The tunneling through the intercondylar osteophytes was performed to allow the arthroscope to pass trans-notch. To avoid additional accessory posterior portals, we used a 70° arthroscope to better explore the posterior knee compartment. The cartilage-like bodies were removed and synovectomy of the inflamed areas was performed. The clinical and radiological follow-up was 12 months and the patient showed excellent clinical outcomes, returning to his activities of daily living and sport activity. CONCLUSION: Our case report highlights the importance of the arthroscopic approach to treat synovial chondromatosis, despite the involvement of the posterior compartment of the knee. An optimal preoperative imaging allows to plan for the proper surgical procedure even in patients with severe osteoarthritis. Moreover, the adoption of an intercondylar notch tunneling and a 70° arthroscope can help surgeons to better explore the posterior knee compartment, avoiding an accessory posterior trans-septal portal. Therefore, a synovectomy of the inflamed foci may be useful to prevent recurrence.


Subject(s)
Chondromatosis, Synovial , Joint Loose Bodies , Humans , Male , Adult , Activities of Daily Living , Chondromatosis, Synovial/diagnostic imaging , Chondromatosis, Synovial/surgery , Knee Joint/diagnostic imaging , Knee Joint/surgery , Joint Loose Bodies/diagnostic imaging , Joint Loose Bodies/surgery , Synovectomy , Arthroscopy/methods
14.
J Orthop ; 34: 94-99, 2022.
Article in English | MEDLINE | ID: mdl-36046757

ABSTRACT

Introduction: Lesser trochanter (LT) fixation to restore the continuity of the posteromedial fragment using a cerclage wire has been reported to provide a more stable reduction in the treatment of unstable femoral neck fractures with LT involvement. However, LT fixation is not commonly performed due to the complications associated with the traditional monofilament cerclage metal wires. In this study, we investigate the clinical and radiological outcomes of a new technique for LT fixation in conjunction with Intramedullary (IM) fixation with nail and screws when compared to isolated IM fixation. The Sling Fixation Technique involves a new wiring technique and the use of a polymer-based cerclage cable characterized by iso-elastic properties that is hypothesized to provide better clinical and radiographic outcomes. Patients and methods: This prospective observational study included 30 patients who underwent proximal IM nailing from July 2019 to April 2020. Thirty consecutive patients (30) were assigned to 2 different treatment groups. Fifteen (15) patients were treated with the IM Nailing and Sling Fixation Technique and 15 with IM nailing only. Patients were comparable for demographic features, fracture pattern, age, gender and associated medical comorbidities. Clinical outcomes were analyzed in terms of time needed to achieve complete weight bearing, Harris hip score (HHS), Barthel Index (BI) and Radiographic Union Scale for Hip (RUSH). The follow-up period was one year. Results: Time for fracture healing and to achieve weight-bearing in the "Sling" group were shown to be significantly shorter than in the IM group. The Sling group showed furthermore better HHS, BI and RUSH scores when compared to the IM group at 1, 3, 6, and 12 months from the surgery. No complications such as wiring breakage, cut-outs, breakage or pullout of the fixation screws were observed; one case of heterotrophic ossification was reported. Conclusion: In cases of unstable intertrochanteric fractures of the proximal femur with lesser trochanter involvement, the Sling fixation technique using an isoelastic polymer-based wire showed superior results in terms of stability and consequently better clinical and radiographic outcomes than IM nailing only.

15.
Clin Interv Aging ; 17: 1163-1171, 2022.
Article in English | MEDLINE | ID: mdl-35957924

ABSTRACT

Background: In elderly patients with hip fracture, the prevalence of severe aortic stenosis (valve area <1 cm2) is close to 5%. Few studies have evaluated the prognostic role of aortic stenosis in hip fracture surgery and none has considered the effects of the postoperative setting (intensive care unit vs general ward) on clinical outcome. Purpose: The aim of the present study was to evaluate the factors affecting mortality in patients with severe aortic stenosis undergoing surgery for hip fracture. We also evaluated whether postoperative monitoring in the intensive care unit may affect the prognosis in comparison to return to the general ward after surgery. Patients and Methods: All 2274 patients referred for hip fracture to our tertiary teaching hospital between January 1 2015 and December 31 2019 were screened for the presence of severe aortic stenosis, defined by an aortic valve area <1.0 cm2. Results: The study included 66 patients (27 males, 39 females) with a mean±SD age of 85±7 years. The average time between trauma and surgery was 2.6±3 days. The mean aortic valve area was 0.74±0.15 cm2. Seven patients died during hospitalization (10.4%). Diabetes, having two or more comorbidities, a low degree of autonomy, heart failure, history of coronary artery disease, atrial fibrillation, postoperative delirium and pulmonary hypertension were associated with poorer outcome. In logistic multivariate analysis, the number of diseases and values of pulmonary artery pressure were the only independent factors related to mortality. In hospital mortality (12 and 9%, respectively) and complication rates were not statistically different between patients referred to the intensive care unit for postoperative monitoring and patients returned to the general ward after surgery. Conclusion: In patients undergoing hip fracture surgery, severe aortic stenosis is associated with high hospital mortality, and two or more comorbidities and pulmonary hypertension are associated with a worse prognosis. The postoperative setting (intensive care unit or general ward) does not affect outcome.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Hip Fractures , Hypertension, Pulmonary , Aged , Aged, 80 and over , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/surgery , Female , Hip Fractures/complications , Hip Fractures/surgery , Hospital Mortality , Humans , Hypertension, Pulmonary/complications , Hypertension, Pulmonary/surgery , Male , Retrospective Studies , Risk Factors , Treatment Outcome
16.
Osteoporos Int ; 33(12): 2467-2478, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35851407

ABSTRACT

Osteoporotic fractures are one of the major problems facing healthcare systems worldwide. Undoubtedly, fragility fractures of the hip represent a far greater burden in terms of morbidity, mortality, and healthcare costs than other fracture sites. However, despite the significant impact on the health and quality of life of older adults, there is a general lack of awareness of osteoporosis, which results in suboptimal care. In fact, most high-risk individuals are never identified and do not receive adequate treatment, leading to further fragility fractures and worsening health status. Furthermore, considering the substantial treatment gap and the proven cost-effectiveness of fracture prevention programs such as Fracture Liaison Services, urgent action is needed to ensure that all individuals at high risk of fragility fracture are adequately assessed and treated. Based on this evidence, the aim of our review was to (i) provide an overview and comparison of the burden and management of fragility fractures, highlighting the main gaps, and (ii) highlight the importance of using alternative approaches, both surgical and non-surgical, with the aim of implementing early prevention of osteoporotic fractures and improving the management of osteoporotic patients at imminent and/or very high risk of fracture.


Subject(s)
Bone Density Conservation Agents , Osteoporosis , Osteoporotic Fractures , Humans , Aged , Osteoporotic Fractures/prevention & control , Osteoporotic Fractures/surgery , Quality of Life , Osteoporosis/complications , Osteoporosis/therapy , Cost-Benefit Analysis , Delivery of Health Care , Secondary Prevention , Bone Density Conservation Agents/therapeutic use
17.
J Orthop Surg Res ; 17(1): 299, 2022 Jun 03.
Article in English | MEDLINE | ID: mdl-35659012

ABSTRACT

BACKGROUND: Knee varus alignment represents a notorious cause of knee osteoarthritis. It can be caused by tibial deformity, combined tibial-femoral deformity and/or ligament imbalance. Understanding malalignment is crucial in total knee arthroplasty to restore frontal plane neutral mechanical axis. The aim of this study was to determine which factor contributes the most to varus osteoarthritic knee and its related surgical implications in performing a total knee arthroplasty. METHODS: We retrospectively evaluated 140 patients operated for total knee arthroplasty due to a varus knee. Full-leg hip to ankle preoperative X-rays were taken. Radiological parameters recorded were: mechanical axis deviation, hip-knee-ankle, anatomical-mechanical angle, medial neck shaft angle, mechanical lateral distal femoral angle (mLDFA), medial proximal tibial angle (MPTA), joint line convergence angle (JLCA), lateral proximal femoral angle, lateral distal tibial angle (LDTA), femoral bowing, and length of tibia and femur. We also determined ideals tibial and femoral cuts in mm according to mechanical alignment technique. A R2 was calculated based on the linear regression between the predicted values and the observed data. RESULTS: The greatest contributor to arthritic varus (R = 0.444) was MPTA. Minor contributors were mLDFA (R = 0.076), JLCA (R = 0.1554), LDTA (R = 0.065), and femoral bowing (R = 0.049). We recorded an average of 7.6 mm in lateral tibial cut thickness to restore neutral alignment. CONCLUSIONS: The radiological major contributor to osteoarthritic varus knee alignment is related to proximal tibia deformity. As a surgical consequence, during performing total knee arthroplasty, the majority of the correction should therefore be made on tibial cut.


Subject(s)
Arthroplasty, Replacement, Knee , Genu Varum , Osteoarthritis, Knee , Femur/diagnostic imaging , Femur/surgery , Genu Varum/surgery , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/surgery , Retrospective Studies , Tibia/diagnostic imaging , Tibia/surgery
18.
J Knee Surg ; 35(14): 1549-1555, 2022 Dec.
Article in English | MEDLINE | ID: mdl-33853154

ABSTRACT

Robotic-assisted medial unicompartmental knee arthroplasty (mUKA) has been introduced to improve accuracy in implant positioning and limb alignment, overcoming the reported high failure rates of conventional UKA. Indeed, mUKA is a technically challenging procedure strongly related to surgeons' skills and expertise. The purpose of this study was to evaluate the likelihood of robotic-assisted surgery in reducing the variability of coronal and sagittal component positioning between high- and low-volume surgeons. We evaluated a prospective cohort of 161 robotic mUKA implanted between May 2018 and December 2019 at two high-volume robotic centers. Patients were divided into two groups: patients operated by "high-volume" (group A) or "low-volume" (group B) surgeons. We recorded intraoperative lower-limb alignment, component positioning, and surgical timing. Postoperatively, every patient underwent a radiographical protocol to assess coronal and sagittal femoral/tibial component alignment. Range of motion and other clinical outcomes were assessed pre- and 12 months postoperatively by using oxford knee score, forgotten joint score, and visual analog scale. Of 161 recruited knees, 149 (A: 101; B: 48) were available for radiographic analysis at 1 month, and clinical evaluation at 12 months. No clinical difference neither difference in mechanical alignment nor coronal/sagittal component positioning were found (p > 0.05). A significant difference was recorded in surgical timing (A: 57 minutes; B: 86 minutes; p < 0.05). No superficial or deep infections or other major complications have been developed during the follow-up. Robotics surgery in mUKA confirmed its value in improving the reproducibility of such technical procedure, with satisfactory clinical outcomes. Moreover, it almost eliminates any possible differences in component positioning, and lower limb alignment among low-and high- volume knee surgeons.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Robotic Surgical Procedures , Surgeons , Humans , Arthroplasty, Replacement, Knee/methods , Robotic Surgical Procedures/methods , Prospective Studies , Reproducibility of Results , Knee Joint/surgery , Osteoarthritis, Knee/surgery
19.
Arch Orthop Trauma Surg ; 142(11): 3523-3531, 2022 Nov.
Article in English | MEDLINE | ID: mdl-34782910

ABSTRACT

AIMS: In case of severe bone loss, acetabular revision can be challenged using extra porous pure trabecular titanium (TT) revision cups designed to ensure enhanced iliac and ischiatic purchase. Aim of the study is to report on the clinical and radiological results of a TT acetabular component, evaluating functional outcome, restoration of the hip center of rotation and osteointegration. METHODS: 85 patients, who underwent acetabular revision with a TT revision cup system between October 2009 and December 2018, were included in a retrospective study. Clinical outcome were assessed with Harris Hip Score (HHS). The hip rotation center was measured using the Pierchon method on the AP pelvis film. Loosening of the cup was determined according to the Kosashvili modification of Gill's criteria. Kaplan- Meier survivorship curve was performed. Results The mean follow-up was 6.12 years. The average HHS improved from 54.7 points to 89.7 points (p < 0.05). Two acetabular components (2.3%) were re-revised after a mean of 5.6 years, for aseptic loosening and for infection, with a progressive radiolucency and a > 5 mm vertical migration, respectively. The radiographic evaluation of the position of the hip rotation center revealed a statistically significant difference (p < 0.05) between the pre- and post-operative values. The hip rotation center was correctly restored within 5% of the reference Pierchon values in a percentage of 85.4% relative to horizontal parameters and within 8% in a percentage of 66.7% relative to vertical parameters. 5-year and 10-year survivorships were, respectively, 100% and 88%. CONCLUSIONS: In case of severe bone loss, TT revision cup system allows for good restoration of center of rotation and osteointegration showing good 10-year survival rate.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Follow-Up Studies , Humans , Prosthesis Failure , Reoperation , Retrospective Studies , Rotation , Survivorship , Titanium
20.
J Bone Joint Surg Am ; 104(2): 189-200, 2022 01 19.
Article in English | MEDLINE | ID: mdl-34780382

ABSTRACT

➤: Bone marrow edema (BME) is a nonspecific but relevant finding, usually indicating the presence of an underlying pathology. ➤: The gold standard technique for detecting BME is magnetic resonance imaging (MRI), as it allows for a correct diagnosis to be made, which is extremely important given the heterogeneity of BME-related diseases. ➤: Depending on the severity of painful symptomatology and the MRI evidence, different treatment strategies can be followed: physical modalities, pharmacological options, and surgical therapy.


Subject(s)
Bone Marrow Diseases , Edema , Magnetic Resonance Imaging , Bone Marrow Diseases/diagnostic imaging , Bone Marrow Diseases/etiology , Bone Marrow Diseases/therapy , Diagnosis, Differential , Edema/diagnostic imaging , Edema/etiology , Edema/therapy , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...