1.
Sensors (Basel) ; 22(15)2022 Jul 26.
Article in English | MEDLINE | ID: mdl-35898085

ABSTRACT

Chemometric models for on-line process monitoring have become well established in pharmaceutical bioprocesses. The main drawback is the required calibration effort and the inflexibility regarding system or process changes. So, a recalibration is necessary whenever the process or the setup changes even slightly. With a large and diverse Raman dataset, however, it was possible to generate generic partial least squares regression models to reliably predict the concentrations of important metabolic compounds, such as glucose-, lactate-, and glutamine-indifferent CHO cell cultivations. The data for calibration were collected from various cell cultures from different sites in different companies using different Raman spectrophotometers. In testing, the developed "generic" models were capable of predicting the concentrations of said compounds from a dilution series in FMX-8 mod medium, as well as from an independent CHO cell culture. These spectra were taken with a completely different setup and with different Raman spectrometers, demonstrating the model flexibility. The prediction errors for the tests were mostly in an acceptable range (<10% relative error). This demonstrates that, under the right circumstances and by choosing the calibration data carefully, it is possible to create generic and reliable chemometric models that are transferrable from one process to another without recalibration.


Subject(s)
Chemometrics , Spectrum Analysis, Raman , Animals , CHO Cells , Calibration , Cricetinae , Cricetulus , Least-Squares Analysis
2.
Eng Life Sci ; 19(5): 341-351, 2019 May.
Article in English | MEDLINE | ID: mdl-32625013

ABSTRACT

This study was performed in order to evaluate a new LED-based 2D-fluorescence spectrometer for in-line bioprocess monitoring of Chinese hamster ovary (CHO) cell culture processes. The new spectrometer used selected excitation wavelengths of 280, 365, and 455 nm to collect spectral data from six 10-L fed-batch processes. The technique provides data on various fluorescent compounds from the cultivation medium as well as from cell metabolism. In addition, scattered light offers information about the cultivation status. Multivariate data analysis tools were applied to analyze the large data sets of the collected fluorescence spectra. First, principal component analysis was used to accomplish an overview of all spectral data from all six CHO cultivations. Partial least square regression models were developed to correlate 2D-fluorescence spectral data with selected critical process variables as offline reference values. A separate independent fed-batch process was used for model validation and prediction. An almost continuous in-line bioprocess monitoring was realized because 2D-fluorescence spectra were collected every 10 min during the whole cultivation. The new 2D-fluorescence device demonstrates the significant potential for accurate prediction of the total cell count, viable cell count, and the cell viability. The results strongly indicated that the technique is particularly capable to distinguish between different cell statuses inside the bioreactor. In addition, spectral data provided information about the lactate metabolism shift and cellular respiration during the cultivation process. Overall, the 2D-fluorescence device is a highly sensitive tool for process analytical technology applications in mammalian cell cultures.

3.
Eng Life Sci ; 19(5): 352-362, 2019 May.
Article in English | MEDLINE | ID: mdl-32625014

ABSTRACT

A new two-dimensional fluorescence sensor system was developed for in-line monitoring of mammalian cell cultures. Fluorescence spectroscopy allows for the detection and quantification of naturally occurring intra- and extracellular fluorophores in the cell broth. The fluorescence signals correlate to the cells' current redox state and other relevant process parameters. Cell culture pretests with twelve different excitation wavelengths showed that only three wavelengths account for a vast majority of spectral variation. Accordingly, the newly developed device utilizes three high-power LEDs as excitation sources in combination with a back-thinned CCD-spectrometer for fluorescence detection. This setup was first tested in a lab design of experiments study with process relevant fluorophores proving its suitability for cell culture monitoring with LOD in the µg/L range. The sensor was then integrated into a CHO-K1 cell culture process. The acquired fluorescence spectra of several batches were evaluated using multivariate methods. The resulting batch evolution models were challenged in deviating and "golden batch" validation runs. These first tests showed that the new sensor can trace the cells' metabolic state in a fast and reliable manner. Cellular distress is quickly detected as a deviation from the "golden batch".

4.
Anal Bioanal Chem ; 409(3): 651-666, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27900421

ABSTRACT

The use of spectroscopic sensors for bioprocess monitoring is a powerful tool within the process analytical technology (PAT) initiative of the US Food and Drug Administration. Spectroscopic sensors enable the simultaneous real-time bioprocess monitoring of various critical process parameters including biological, chemical, and physical variables during the entire biotechnological production process. This potential can be realized through the combination of spectroscopic measurements (UV/Vis spectroscopy, IR spectroscopy, fluorescence spectroscopy, and Raman spectroscopy) with multivariate data analysis to obtain relevant process information out of an enormous amount of data. This review summarizes the newest results from science and industry after the establishment of the PAT initiative and gives a critical overview of the most common in-line spectroscopic techniques. Examples are provided of the wide range of possible applications in upstream processing and downstream processing of spectroscopic sensors for real-time monitoring to optimize productivity and ensure product quality in the pharmaceutical industry.


Subject(s)
Biotechnology/instrumentation , Spectrum Analysis, Raman/instrumentation , Technology, Pharmaceutical/instrumentation , Biosensing Techniques/instrumentation