Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Perinatol ; 38(11): 1167-1173, 2021 09.
Article in English | MEDLINE | ID: mdl-32446255

ABSTRACT

OBJECTIVE: Early bubble continuous positive airway pressure (bCPAP) in the delivery room (DR) reduces early intubation, mechanical ventilation, and bronchopulmonary dysplasia. The RAM cannula, adopted for ease of patient care, is a high resistance nasal interface that, when used with bCPAP, only transmits a portion of set pressures and attenuates the bubble effects. This study aimed to review early bCPAP pressures and bCPAP failure with the RAM cannula interface over a 6-year period. STUDY DESIGN: Retrospective, single-center study of infants delivered <1,250 g from 2013 to 2018 (n = 735) begun on bCPAP in the DR with the RAM cannula. In vitro testing of bCPAP pressure transmission was also performed for multiple nasal interfaces and nasal occlusion percentages. RESULTS: The percentage of infants intubated in the DR decreased over time (59 to 42%), while the average bCPAP pressure increased from 5.3 to 6.8 cmH2O. A total of 355 infants (48%) were admitted to the neonatal intensive care unit (NICU) from the DR on BCPAP. The failure rate for bCPAP in NICU within 72 hours decreased from 45 to 24% as the maximum CPAP increased from 5.8 to 7.6 cmH2O. Pneumothorax rates did not change. CPAP pressure transmission decreased with all sizes of the RAM cannula. CONCLUSION: When utilizing the RAM cannula for bCPAP, higher CPAP levels were associated with decreases in DR intubations and CPAP failure within the first 72 hours. If clinicians choose to use the RAM cannula for bCPAP, they will need higher set pressures to achieve lung inflation and the beneficial oscillatory effect will be diminished. KEY POINTS: · The transmission of the pressure oscillations from bubble CPAP is diminished with the RAM cannula.. · Increasing set CPAP pressures was associated with a decreased delivery room intubation rate and a decreased CPAP failure rate within 72 hours.. · Clinicians using the RAM cannula for bCPAP will need to increase pressures to obtain adequate lung inflation or change to a nasal interface designed for bCPAP..


Subject(s)
Continuous Positive Airway Pressure/instrumentation , Respiratory Distress Syndrome, Newborn/therapy , Cannula , Female , Humans , Infant, Newborn , Infant, Premature , Infant, Very Low Birth Weight , Intensive Care Units, Neonatal , Intubation, Intratracheal , Linear Models , Male , Pressure , Retrospective Studies , Treatment Failure
3.
Neoreviews ; 20(3): e145-e151, 2019 03.
Article in English | MEDLINE | ID: mdl-31261052

ABSTRACT

The tracheal aspirate (TA) culture is commonly ordered in the NICU, but it has low sensitivity and specificity, limited by contamination. Interpretation of a TA culture out of context can lead to antibiotic overuse, which should be avoided. Clinicians should practice caution in the diagnosis of congenital pneumonia and use newer, published approaches to the diagnosis of ventilator-associated pneumonia in neonates. A subset of neonatal patients with risk factors of maternal fever or chorioamnionitis requiring intubation may benefit from TA culture performed within 12 hours after birth, to help identify an organism when blood culture may be negative, and tailor antimicrobial therapies. The more invasive, but more sensitive, technique of nonbronchoscopic bronchoalveolar lavage should be considered in older infants when bacterial isolation from the lower respiratory tract is necessary, because TA culture cannot distinguish between colonization and infection in that population.


Subject(s)
Respiratory Tract Infections/diagnosis , Trachea/microbiology , Humans , Infant, Newborn , Microbiological Techniques , Respiratory Tract Infections/microbiology , Respiratory Tract Infections/therapy
4.
Neonatology ; 115(1): 28-35, 2019.
Article in English | MEDLINE | ID: mdl-30278459

ABSTRACT

INTRODUCTION: Bubble continuous positive airway pressure (bCPAP) generates a variable pressure due to bubble size and frequency, and these pressure oscillations may contribute to lung recruitment and gas exchange. Single-outlet bCPAP devices generate larger pressure fluctuation than bCPAP devices with diffusers, but clinical efficacy is unclear. Our hypothesis was that a single-outlet bCPAP device (B&B Bubbler©) would decrease extubation failure and improve oxygenation compared with a bCPAP device with a diffuser (BabiPlus©). METHODS: Bench testing of bCPAP devices with the RAM© cannula determined pressure averages, fluctuations, and CPAP transmission at prongs. The B&B Bubbler© and the BabiPlus© devices were compared for oxygenation and bCPAP failure within 72 h of extubation in a randomized trial in infants less than 1,250 g (n = 43). Additionally, a cohort study with infants extubated to BabiPlus© (n = 128), B&B Bubbler© (n = 119), and noninvasive positive pressure ventilation (NIPPV) (n = 107) were compared. RESULTS: Small differences in pressure fluctuations between bCPAP devices are attenuated by the RAM© cannula. Pressures at RAM© prongs are 62% of set pressure. The bCPAP extubation failure rate (35%) and oxygenation were similar between the bCPAP devices. bCPAP success was associated with lower FiO2 at extubation and decreased need for additional FiO2 in both groups. In the setting of the RAM© cannula, there were no differences in extubation failure rate for infants extubated to bCPAP or NIPPV. CONCLUSIONS: There were no clinical differences at extubation between the B&B Bubbler© and BabiPlus© devices. Oxygenation may predict bCPAP failure. The use of the RAM© cannula as a bCPAP interface should be more closely examined.


Subject(s)
Continuous Positive Airway Pressure/instrumentation , Device Removal , Infant, Very Low Birth Weight , Respiratory Distress Syndrome, Newborn/therapy , Ventilator Weaning/methods , Cannula , Female , Humans , Infant, Newborn , Infant, Premature , Intubation, Intratracheal , Male , Retrospective Studies , Treatment Failure
SELECTION OF CITATIONS
SEARCH DETAIL
...