Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Sci Total Environ ; 939: 173447, 2024 Aug 20.
Article in English | MEDLINE | ID: mdl-38788942

ABSTRACT

Transmission of airborne infectious diseases poses great risk for public health and socio-economic stability, thus, there is a need for an effective control method targeting the spread and transmission of pathogenic aerosols. The existence of chemically-reductive trace air contaminants in animal agriculture may affect the oxidation inactivation process of pathogens. In this study, we report how the presence of such gasses impacts the effectiveness of using non-thermal plasma (NTP) within a packed-bed dielectric barrier discharge reactor to inactivate MS2 bacteriophage. Inactivation of the aerosolized bacteriophage is determined by the combination of viability and polymerase chain reaction assays. Using a plasma power source with a voltage of 20 kV and frequency of 350 Hz, after differentiating and excluding the physical removal effects of viral aerosols potentially caused by plasma, the baseline inactivation of MS2 aerosol in air has been determined based on an overall air flow rate of 200 Liters per minute and plasma discharge power of 1.8 W. When either ammonia or hydrogen sulfide gas is introduced into the airstream at a concentration of 1 part per million, the NTP virus inactivation efficiency is reduced to around 0.5-log from the 1-log baseline inactivation in air alone. Higher concentrations of those gasses will not further inhibit the effectiveness of plasma inactivation.


Subject(s)
Air Microbiology , Plasma Gases , Virus Inactivation , Virus Inactivation/drug effects , Aerosols , Levivirus/drug effects , Air Pollutants
2.
Open Forum Infect Dis ; 8(2): ofaa610, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33575418

ABSTRACT

BACKGROUND: Due to unprecedented shortages in N95 filtering facepiece respirators, healthcare systems have explored N95 reprocessing. No single, full-scale reprocessing publication has reported an evaluation including multiple viruses, bacteria, and fungi along with respirator filtration and fit. METHODS: We explored reprocessing methods using new 3M 1860 N95 respirators, including moist (50%-75% relative humidity [RH]) heat (80-82°C for 30 minutes), ethylene oxide (EtO), pulsed xenon UV-C (UV-PX), hydrogen peroxide gas plasma (HPGP), and hydrogen peroxide vapor (HPV). Respirator samples were analyzed using 4 viruses (MS2, phi6, influenza A virus [IAV], murine hepatitis virus [MHV)]), 3 bacteria (Escherichia coli, Staphylococcus aureus, Geobacillus stearothermophilus spores, and vegetative bacteria), and Aspergillus niger. Different application media were tested. Decontaminated respirators were evaluated for filtration integrity and fit. RESULTS: Heat with moderate RH most effectively inactivated virus, resulting in reductions of >6.6-log10 MS2, >6.7-log10 Phi6, >2.7-log10 MHV, and >3.9-log10 IAV and prokaryotes, except for G stearothermohphilus. Hydrogen peroxide vapor was moderately effective at inactivating tested viruses, resulting in 1.5- to >4-log10 observable inactivation. Staphylococcus aureus inactivation by HPV was limited. Filtration efficiency and proper fit were maintained after 5 cycles of heat with moderate RH and HPV. Although it was effective at decontamination, HPGP resulted in decreased filtration efficiency, and EtO treatment raised toxicity concerns. Observed virus inactivation varied depending upon the application media used. CONCLUSIONS: Both moist heat and HPV are scalable N95 reprocessing options because they achieve high levels of biological indicator inactivation while maintaining respirator fit and integrity.

3.
J Air Waste Manag Assoc ; 67(8): 881-888, 2017 08.
Article in English | MEDLINE | ID: mdl-28287914

ABSTRACT

Among the technologies available for reducing mercury emissions from coal-fired electric utilities is the injection of a powdered sorbent, often some form of activated carbon, into the flue gas upstream of the particulate control device, most commonly an electrostatic precipitator (ESP). Detailed measurements of mercury removal within ESPs are lacking due to the hazardous environment they pose, increasing the importance of analysis and numerical simulation in understanding the mechanisms involved. Our previous analyses revealed that mercury adsorption by particles suspended in the gas and mercury adsorption by particles collected on internal ESP surfaces are not additive removal mechanisms but rather are competitive. The present study expands on this counterintuitive finding. Presented are results from numerical simulations reflecting the complete range of possible mass transfer boundary conditions representing mercury adsorption by the accumulated dust cake covering internal ESP collection electrodes. Using the two mercury removal mechanisms operating concurrently and interdependently always underperforms the sum of the two mechanisms' individual contributions. IMPLICATIONS: The dual use of electrostatic precipitators (ESPs) for particulate removal and adsorption of trace gaseous pollutants such as mercury is increasing as mercury regulations become more widespread. Under such circumstances, mercury adsorption by particles suspended in the gas and mercury adsorption by particles collected on internal ESP surfaces are competitive. Together, the two mercury removal mechanisms always underperform the sum of their two independent contributions. These findings can inform strategies sought by electric utilities for reducing the usage costs of mercury sorbents.


Subject(s)
Air Pollutants/chemistry , Mercury/chemistry , Static Electricity , Adsorption , Air Pollution/prevention & control , Coal , Power Plants
4.
Environ Sci Technol ; 48(17): 10519-23, 2014 Sep 02.
Article in English | MEDLINE | ID: mdl-25093939

ABSTRACT

Injection of powdered activated carbon (PAC) adsorbents into the flue gas of coal fired power plants with electrostatic precipitators (ESPs) is the most mature technology to control mercury emissions for coal combustion. However, the PAC itself can penetrate ESPs to emit into the atmosphere. These emitted PACs have similar size and optical properties to submicron black carbon (BC) and thus could increase BC radiative forcing unintentionally. The present paper estimates, for the first time, the potential emission of PAC together with their climate forcing. The global average maximum potential emissions of PAC is 98.4 Gg/yr for the year 2030, arising from the assumed adoption of the maximum potential PAC injection technology, the minimum collection efficiency, and the maximum PAC injection rate. These emissions cause a global warming of 2.10 mW m(-2) at the top of atmosphere and a cooling of -2.96 mW m(-2) at the surface. This warming represents about 2% of the warming that is caused by BC from direct fossil fuel burning and 0.86% of the warming associated with CO2 emissions from coal burning in power plants. Its warming is 8 times more efficient than the emitted CO2 as measured by the 20-year-integrated radiative forcing per unit of carbon input (the 20-year Global Warming Potential).


Subject(s)
Air Pollution/prevention & control , Carbon/analysis , Environmental Restoration and Remediation/methods , Mercury/analysis , Particulate Matter/analysis , Radiation , Atmosphere/chemistry , Charcoal/chemistry , Coal , Fossil Fuels , Powders , Power Plants , Soot/analysis , Uncertainty
5.
Environ Sci Technol ; 46(13): 7327-33, 2012 Jul 03.
Article in English | MEDLINE | ID: mdl-22663136

ABSTRACT

The behavior of mercury sorbents within electrostatic precipitators (ESPs) is not well-understood, despite a decade or more of full-scale testing. Recent laboratory results suggest that powdered activated carbon exhibits somewhat different collection behavior than fly ash in an ESP and particulate filters located at the outlet of ESPs have shown evidence of powdered activated carbon penetration during full-scale tests of sorbent injection for mercury emissions control. The present analysis considers a range of assumed differential ESP collection efficiencies for powdered activated carbon as compared to fly ash. Estimated emission rates of submicrometer powdered activated carbon are compared to estimated emission rates of particulate carbon on submicrometer fly ash, each corresponding to its respective collection efficiency. To the extent that any emitted powdered activated carbon exhibits size and optical characteristics similar to black carbon, such emissions could effectively constitute an increase in black carbon emissions from coal-based stationary power generation. The results reveal that even for the low injection rates associated with chemically impregnated carbons, submicrometer particulate carbon emissions can easily double if the submicrometer fraction of the native fly ash has a low carbon content. Increasing sorbent injection rates, larger collection efficiency differentials as compared to fly ash, and decreasing sorbent particle size all lead to increases in the estimated submicrometer particulate carbon emissions.


Subject(s)
Air Pollutants/isolation & purification , Carbon/chemistry , Coal Ash/chemistry , Environmental Restoration and Remediation/methods , Mercury/isolation & purification , Adsorption , Air Pollution/analysis , Charcoal/chemistry , Particle Size , Static Electricity
6.
Environ Sci Technol ; 43(5): 1460-6, 2009 Mar 01.
Article in English | MEDLINE | ID: mdl-19350920

ABSTRACT

Efforts to reduce anthropogenic mercury emissions worldwide have recently focused on a variety of sources, including mercury emitted during coal combustion. Toward that end, much research has been ongoing seeking to develop new processes for reducing coal combustion mercury emissions. Among air pollution control processes that can be applied to coal-fired boilers, electrostatic precipitators (ESPs) are by far the most common, both on a global scale and among the principal countries of India, China, and the U.S. that burn coal for electric power generation. A previously reported theoretical model of in-flight mercury capture within ESPs is herein evaluated against data from a number of full-scale tests of activated carbon injection for mercury emissions control. By using the established particle size distribution of the activated carbon and actual or estimated values of its equilibrium mercury adsorption capacity, the incremental reduction in mercury concentration across each ESP can be predicted and compared to experimental results. Because the model does not incorporate kinetics associated with gas-phase mercury transformation or surface adsorption, the model predictions representthe mass-transfer-limited performance. Comparing field data to model results reveals many facilities performing at or near the predicted mass-transfer-limited maximum, particularly at low rates of sorbent injection. Where agreement is poor between field data and model predictions, additional chemical or physical phenomena may be responsible for reducing mercury removal efficiencies.


Subject(s)
Coal , Mercury/isolation & purification , Models, Chemical , Power Plants , Static Electricity , Adsorption , Carbon/analysis , Chemical Precipitation , Filtration , Particle Size , United States
7.
J Hazard Mater ; 152(2): 616-23, 2008 Apr 01.
Article in English | MEDLINE | ID: mdl-17703878

ABSTRACT

Mercury emissions from coal combustion must be reduced, in response to new air quality regulations in the U.S. Although the most mature control technology is adsorption across a dust cake of powdered sorbent in a fabric filter (FF), most particulate control in the U.S. associated with coal combustion takes the form of electrostatic precipitation (ESP). Using recently developed models of mercury adsorption within an ESP and within a growing sorbent bed in a FF, parallel analyses of elemental mercury (Hg(0)) uptake have been conducted. The results show little difference between an ESP and a FF in absolute mercury removal for a low-capacity sorbent, with a high-capacity sorbent achieving better performance in the FF. Comparisons of fractional mercury uptake per-unit-pressure-drop provide a means for incorporating and comparing the impact of the much greater pressure drop of a FF as compared to an ESP. On a per-unit-pressure-drop basis, mercury uptake within an ESP exhibited better performance, particularly for the low-capacity sorbent and high mass loadings of both sorbents.


Subject(s)
Air Pollutants/isolation & purification , Coal , Incineration , Mercury/isolation & purification , Power Plants , Adsorption , Filtration/instrumentation , Static Electricity
8.
Environ Sci Technol ; 40(12): 3929-33, 2006 Jun 15.
Article in English | MEDLINE | ID: mdl-16830563

ABSTRACT

Varying degrees of mercury capture and transformation have been reported across electrostatic precipitators (ESPs). Previous analyses have shown that the dominant mass transfer mechanism responsible for mercury capture within ESPs is gas-particle mass transfer during particulate collection. Whereas previous analyses assumed dispersions of uniform size, the present analysis reveals the effects of polydispersity on both gas-particle mass transfer and particle collection within an ESP. The analysis reveals that the idealized monodisperse particle size distribution provides the highest gas-particle mass transfer but results in the lowest particle collection efficiency (% mass). As the particle size distribution broadens, gas-particle mass transfer decreases and particle collection efficiency increases. The results suggest that more than just reporting mean particle diameter provided by the sorbent manufacturer, pilot- and field-tests of sorbent injection for mercury emissions control need to experimentally measure the particle size distribution of the sorbent as it is injected in order to facilitate interpretation of their results.


Subject(s)
Air Pollutants/analysis , Mercury/analysis , Static Electricity , Coal , Gases , Incineration , Models, Theoretical , Particle Size , Power Plants
9.
J Air Waste Manag Assoc ; 56(6): 759-66, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16805400

ABSTRACT

Varying degrees of mercury (Hg) capture have been reported within the electrostatic precipitators (ESPs) of coal-fired electric utility boilers. There has been some speculation that the adsorption takes place on the particulate-covered plate electrodes. This convective mass transfer analysis of laminar and turbulent channel flows provides the maximum potential for Hg adsorption by the plate electrodes within an ESP under those conditions. Mass transfer calculations, neglecting electrohydrodynamic (EHD) effects, reveal 65% removal of elemental Hg for a laminar flow within a 15-m-long channel of 0.2-m spacing and 42% removal for turbulent flow within a similar configuration. Both configurations represent specific collection areas (SCAs) that are significantly larger than conventional ESPs in use. Results reflecting more representative SCA values generally returned removal efficiencies of <20%. EHD effects, although potentially substantial at low Reynolds numbers, diminish rapidly with increasing Reynolds number and become negligible at typical ESP operating conditions. The present results indicate maximum Hg removal efficiencies for ESPs that are much less than those observed in practice for comparable ESP operating conditions. Considering Hg adsorption kinetics and finite sorbent capacity in addition to the present mass transfer analyses would yield even lower adsorption efficiencies than the present results. In a subsequent paper, the author addresses the mass transfer potential presented by the charged, suspended particulates during their collection within an ESP and the role they potentially play in Hg capture within ESPs.


Subject(s)
Air Pollutants/chemistry , Air Pollution/prevention & control , Mercury/chemistry , Power Plants , Adsorption , Air Pollutants/analysis , Coal , Electrodes , Mercury/analysis
10.
Environ Sci Technol ; 40(11): 3617-22, 2006 Jun 01.
Article in English | MEDLINE | ID: mdl-16786702

ABSTRACT

Electrostatic precipitation is the dominant method of particulate control used for coal combustion, and varying degrees of mercury capture and transformation have been reported across ESPs. Nevertheless, the fate of gas-phase mercury within an ESP remains poorly understood. The present analysis focuses on the gas-particle mass transfer that occurs within a charged aerosol in an ESP. As a necessary step in gas-phase mercury adsorption or transformation, gas-particle mass transfer-particularly in configurations other than fixed beds-has received far less attention than studies of adsorption kinetics. Our previous analysis showed that only a small fraction of gas-phase mercury entering an ESP is likelyto be adsorbed by collected particulate matter on the plate electrodes. The present simplified analysis provides insight into gas-particle mass transfer within an ESP under two limiting conditions: laminar and turbulent fluid flows. The analysis reveals that during the process of particulate collection, gas-particle mass transfer can be quite high, easily exceeding the mass transfer to ESP plate electrodes in most cases. Decreasing particle size, increasing particle mass loading, and increasing temperature all result in increased gas-particle mass transfer. The analysis predicts significantly greater gas-particle mass transfer in the laminar limitthan in the turbulent limit; however, the differences become negligible under conditions where other factors, such as total mass of suspended particulates, are the controlling mass transfer parameters. Results are compared to selected pilot- and full-scale sorbent injection data.


Subject(s)
Aerosols/analysis , Air Pollutants/analysis , Mercury/analysis , Adsorption , Aerosols/chemistry , Air Pollutants/chemistry , Air Pollution/prevention & control , Chemical Precipitation , Environmental Monitoring/methods , Mercury/chemistry , Static Electricity
SELECTION OF CITATIONS
SEARCH DETAIL
...