Am J Emerg Med ; 76: 164-172, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38086182

ABSTRACT

INTRODUCTION: Over the past two decades, transesophageal echocardiography (TEE) has been used with increasing frequency to evaluate critically ill patients outside of traditional settings. The purpose of this study was to characterize the number of programs, users, practice characteristics, training and competency requirements and barriers for the current use of resuscitative transesophageal echocardiography (TEE) in Emergency Departments (EDs) in the United States and Canada. METHODS: A closed internet-based, cross-sectional, point-prevalence survey was administered via email to 120 program directors of emergency ultrasound fellowships (EUSF) and 43 physicians from EDs without EUSF from the United States and Canada. RESULTS: Ninety-eight percent of surveyed participants responded. Twenty percent of respondents reported having active resuscitative TEE programs. The majority of participating hospitals (70%) were academic centers with residency programs. A total of 33 programs reported using resuscitative TEE in their ED and of those, 82% were programs with EUSF. Most programs performing TEE (79%) had less than five attending physicians performing TEE. Evaluation of patients during resuscitation from cardiac arrest (100%) and post-arrest care (76%) are the two most frequent indications for TEE in the ED. The most common core elements of resuscitative TEE protocols used are: assessment of left ventricular (LV) systolic function (97%), assessment of right ventricular (RV) function (88%), evaluation of pericardial effusion / tamponade (52%). All programs reported using formal didactics in their training programs, 94% reported using high-fidelity simulation, and 79% live scanning of patients. Financial concerns were the most common barrier use of TEE in the ED (58%), followed by maintenance of equipment (30%), and credentialing/privileges (30%). CONCLUSIONS: This study provides a snapshot of the practice of resuscitative TEE in EDs in the United States and Canada revealing the existence of 33 programs using this emerging modality in the care of critically ill patients.


Subject(s)
Cardiac Tamponade , Echocardiography, Transesophageal , Humans , United States , Cross-Sectional Studies , Critical Illness , Canada , Emergency Service, Hospital
3.
J Am Heart Assoc ; 12(23): e031530, 2023 Dec 05.
Article in English | MEDLINE | ID: mdl-38038192

ABSTRACT

BACKGROUND: Every year the American Heart Association's Resuscitation Science Symposium (ReSS) brings together a community of international resuscitation science researchers focused on advancing cardiac arrest care. METHODS AND RESULTS: The American Heart Association's ReSS was held in Chicago, Illinois from November 4th to 6th, 2022. This annual narrative review summarizes ReSS programming, including awards, special sessions and scientific content organized by theme and plenary session. CONCLUSIONS: By exploring both the science of resuscitation and important related topics including survivorship, disparities, and community-focused programs, this meeting provided important resuscitation updates.


Subject(s)
Cardiopulmonary Resuscitation , American Heart Association
4.
Expert Rev Respir Med ; 17(12): 1125-1139, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38009280

ABSTRACT

INTRODUCTION: Extracorporeal membrane oxygenation (ECMO) facilitated resuscitation was first described in the 1960s, but only recently garnered increased attention with large observational studies and randomized trials evaluating its use. AREAS COVERED: In this comprehensive review of extracorporeal cardiopulmonary resuscitation (ECPR), we report the history of resuscitative ECMO, terminology, circuit configuration and cannulation considerations, complications, selection criteria, implementation and management, and important considerations for the provider. We review the relevant guidelines, different approaches to cannulation, postresuscitation management, and expected outcomes, including neurologic, cardiac, and hospital survival. Finally, we advocate for the participation in national/international Registries in order to facilitate continuous quality improvement and support scientific discovery in this evolving area. EXPERT OPINION: ECPR is the most disruptive technology in cardiac arrest resuscitation since high-quality CPR itself. ECPR has demonstrated that it can provide up to 30% increased odds of survival for refractory cardiac arrest, in tightly restricted systems and for select patients. It is also clear, though, from recent trials that ECPR will not confer this high survival when implemented in less tightly protocoled settings and within lower volume environments. Over the next 10 years, ECPR research will explore the optimal initiation thresholds, best practices for implementation, and postresuscitation care.


Subject(s)
Cardiopulmonary Resuscitation , Extracorporeal Membrane Oxygenation , Heart Arrest , Humans , Cardiopulmonary Resuscitation/adverse effects , Extracorporeal Membrane Oxygenation/adverse effects , Heart Arrest/therapy , Patient Selection , Registries , Retrospective Studies
5.
J Robot Surg ; 17(6): 2849-2854, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37776492

ABSTRACT

Total knee arthroplasty (TKA) has traditionally relied on the surgeon's judgement and manual instruments to determine balance. The MAKO robotic system (Stryker Ltd, Kalamazoo, MI, USA) allows assessment of virtual compartmental gaps from CT-derived bone models intra-operatively as a predictor of soft tissue balance that will be achieved, prior to any bony resection. This study aims to assess the accuracy of this pre-resection balancing technique in determining the resultant final soft tissue balance of the TKA. A consecutive prospective cohort of 2027 Robotic-Assisted TKAs (RATKA) were performed between January'17 and March'22. Osteophytes were removed; initial virtual gaps on the virtual bone model were measured at 10° and 90° of flexion prior to bone resections. Optimization of the virtual component positions was then made and final pre-resection gaps were measured. The gaps were then re-assessed post-implantation and compared to the final pre-resection values. Virtual balancing in extension within 1 mm was achieved in 95% of cases. Of those, 98% maintained coronal balance within 1 mm after implantation, with 1.5% requiring a coronal plane soft tissue release. Inability to virtually balance a TKA within 2 mm prior to bone resection resulted in a soft tissue release in 44.4% of cases. The absolute values of the final gaps achieved were a mean of 1.3 mm greater than virtual gaps. The ability to balance a knee on the virtual bone model prior to bone resection, in conjunction with robotic-assisted execution of TKA, consistently achieves a balanced knee after component implantation.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Robotic Surgical Procedures , Humans , Arthroplasty, Replacement, Knee/methods , Robotic Surgical Procedures/methods , Prospective Studies , Osteoarthritis, Knee/surgery , Knee Joint/surgery
6.
medRxiv ; 2023 Aug 15.
Article in English | MEDLINE | ID: mdl-37645725

ABSTRACT

Background: Systemic hemodynamics and specific ventilator settings have been shown to predict survival during venoarterial extracorporeal membrane oxygenation (VA ECMO). While these factors are intertwined with right ventricular (RV) function, the independent relationship between RV function and survival during VA ECMO is unknown. Objectives: To identify the relationship between RV function with mortality and duration of ECMO support. Methods: Cardiac ECMO runs in adults from the Extracorporeal Life Support Organization (ELSO) Registry between 2010 and 2022 were queried. RV function was quantified via pulmonary artery pulse pressure (PAPP) for pre-ECMO and on-ECMO periods. A multivariable model was adjusted for Society for Cardiovascular Angiography and Interventions (SCAI) stage, age, gender, and concurrent clinical data (i.e., pulmonary vasodilators and systemic pulse pressure). The primary outcome was in-hospital mortality. Results: A total of 4,442 ECMO runs met inclusion criteria and had documentation of hemodynamic and illness severity variables. The mortality rate was 55%; non-survivors were more likely to be older, have a worse SCAI stage, and have longer pre-ECMO endotracheal intubation times (P < 0.05 for all) than survivors. Improving PAPP from pre-ECMO to on-ECMO time (Δ PAPP) was associated with reduced mortality per 10 mm Hg increase (OR: 0.91 [95% CI: 0.86-0.96]; P=0.002). Increasing on-ECMO PAPP was associated with longer time on ECMO per 10 mm Hg (Beta: 15 [95% CI: 7.7-21]; P<0.001). Conclusions: Early improvements in RV function from pre-ECMO values were associated with mortality reduction during cardiac ECMO. Incorporation of Δ PAPP into risk prediction models should be considered.

8.
Oncotarget ; 14: 133-145, 2023 02 11.
Article in English | MEDLINE | ID: mdl-36780330

ABSTRACT

FGFR3-TACC3 represents an oncogenic fusion protein frequently identified in glioblastoma, lung cancer, bladder cancer, oral cancer, head and neck squamous cell carcinoma, gallbladder cancer, and cervical cancer. Various exon breakpoints of FGFR3-TACC3 have been identified in cancers; these were analyzed to determine the minimum contribution of TACC3 for activation of the FGFR3-TACC3 fusion protein. While TACC3 exons 11 and 12 are dispensable for activity, our results show that FGFR3-TACC3 requires exons 13-16 for biological activity. A detailed analysis of exon 13, which consists of 8 heptads forming a coiled coil, further defined the minimal region for biological activity as consisting of 5 heptads from exon 13, in addition to exons 14-16. These conclusions were supported by transformation assays of biological activity, examination of MAPK pathway activation, analysis of disulfide-bonded FGFR3-TACC3, and by examination of the Endoglycosidase H-resistant portion of FGFR3-TACC3. These results demonstrate that clinically identified FGFR3-TACC3 fusion proteins differ in their biological activity, depending upon the specific breakpoint. This study further suggests the TACC3 dimerization domain of FGFR3-TACC3 as a novel target in treating FGFR translocation driven cancers.


Subject(s)
Microtubule-Associated Proteins , Neoplasms , Oncogene Proteins, Fusion , Receptor, Fibroblast Growth Factor, Type 3 , Humans , Cell Line, Tumor , Microtubule-Associated Proteins/genetics , Microtubule-Associated Proteins/metabolism , Oncogene Proteins, Fusion/genetics , Oncogene Proteins, Fusion/metabolism , Receptor, Fibroblast Growth Factor, Type 3/genetics , Receptor, Fibroblast Growth Factor, Type 3/metabolism , Neoplasms/genetics
9.
J Geophys Res Space Phys ; 127(8): e2022JA030334, 2022 Aug.
Article in English | MEDLINE | ID: mdl-36247326

ABSTRACT

The Juno spacecraft's polar orbits have enabled direct sampling of Jupiter's low-altitude auroral field lines. While various data sets have identified unique features over Jupiter's main aurora, they are yet to be analyzed altogether to determine how they can be reconciled and fit into the bigger picture of Jupiter's auroral generation mechanisms. Jupiter's main aurora has been classified into distinct "zones", based on repeatable signatures found in energetic electron and proton spectra. We combine fields, particles, and plasma wave data sets to analyze Zone-I and Zone-II, which are suggested to carry upward and downward field-aligned currents, respectively. We find Zone-I to have well-defined boundaries across all data sets. H+ and/or H3 + cyclotron waves are commonly observed in Zone-I in the presence of energetic upward H+ beams and downward energetic electron beams. Zone-II, on the other hand, does not have a clear poleward boundary with the polar cap, and its signatures are more sporadic. Large-amplitude solitary waves, which are reminiscent of those ubiquitous in Earth's downward current region, are a key feature of Zone-II. Alfvénic fluctuations are most prominent in the diffuse aurora and are repeatedly found to diminish in Zone-I and Zone-II, likely due to dissipation, at higher altitudes, to energize auroral electrons. Finally, we identify significant electron density depletions, by up to 2 orders of magnitude, in Zone-I, and discuss their important implications for the development of parallel potentials, Alfvénic dissipation, and radio wave generation.

11.
Geophys Res Lett ; 49(9): e2022GL098741, 2022 May 16.
Article in English | MEDLINE | ID: mdl-35859815

ABSTRACT

Two distinct proton populations are observed over Jupiter's southern polar cap: a ∼1 keV core population and ∼1-300 keV dispersive conic population at 6-7 RJ planetocentric distance. We find the 1 keV core protons are likely the seed population for the higher-energy dispersive conics, which are accelerated from a distance of ∼3-5 RJ. Transient wave-particle heating in a "pressure-cooker" process is likely responsible for this proton acceleration. The plasma characteristics and composition during this period show Jupiter's polar-most field lines can be topologically closed, with conjugate magnetic footpoints connected to both hemispheres. Finally, these observations demonstrate energetic protons can be accelerated into Jupiter's magnetotail via wave-particle coupling.

12.
J Acoust Soc Am ; 151(3): 1607, 2022 03.
Article in English | MEDLINE | ID: mdl-35364951

ABSTRACT

The main sources of noise in the Arctic Ocean are naturally occurring, rather than related to human activities. Sustained acoustic monitoring at high latitudes provides quantitative measures of changes in the sound field attributable to evolving human activity or shifting environmental conditions. A 12-month ambient sound time series (September 2018 to August 2019) recorded and transmitted from a real-time monitoring station near Gascoyne Inlet, Nunavut is presented. During this time, sound levels in the band 16-6400 Hz ranged between 10 and 135 dB re 1 µPa2/Hz. The average monthly sound levels follow seasonal ice variations with a dependence on the timing of ice melt and freeze-up and with higher frequencies varying more strongly than the lower frequencies. Ambient sound levels are higher in the summer during open water and quietest in the winter during periods of pack ice and shore fast ice. An autocorrelation of monthly noise levels over the ice freeze-up and complete cover periods reveal a ∼24 h periodic trend in noise power at high frequencies (>1000 Hz) caused by tidally driven surface currents in combination with increased ice block collisions or increased stress in the shore fast sea ice.


Subject(s)
Acoustics , Ice Cover , Arctic Regions , Canada , Humans , Sound
13.
Artif Organs ; 46(7): 1369-1381, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35122290

ABSTRACT

BACKGROUND: Extracorporeal membrane oxygenation (ECMO) use in the United States occurs often in cardiothoracic ICUs (CTICU). It is unknown how it varies across ICU types. METHODS: We identified 10 893 ECMO runs from the Extracorporeal Life Support Organization (ELSO) Registry across 2018 and 2019. Primary outcome was ECMO case volume by ICU type (CTICU vs. non-CTICU). Adjusting for pre-ECMO characteristics and case mix, secondary outcomes were on-ECMO physiologic variables by ICU location stratified by support type. RESULTS: CTICU ECMO occurred in 65.1% and 55.1% (2018 and 2019) of total runs. A minority of total runs related to cardiac surgery procedures (CTICU: 21.7% [2018], 18% [2019]; non-CTICU: 11.2% [2018], 13% [2019]). After multivariate adjustment, non-CTICU ECMO for cardiac support associated with lower 4- and 24-h circuit flow (3.9 liters per minute [LPM] vs. 4.1 LPM, p < 0.0001; 4.1 LPM vs. 4.3 LPM, p < 0.0001); for respiratory support, lower on-ECMO mean fraction of inspired oxygen ([Fi O2 ], 67% vs. 69%, p = 0.02) and lower respiratory rate (14 vs. 15, p < 0.0001); and, for extracorporeal cardiopulmonary resuscitation (ECPR), lower ECMO flow rates at 24 h (3.5 LPM vs. 3.7 LPM, p = 0.01). CONCLUSIONS: ECMO mostly remains in CTICUs though a minority is associated with cardiac surgery. Statistically significant but clinically minor differences in on-ECMO metrics were observed across ICU types.


Subject(s)
Cardiopulmonary Resuscitation , Extracorporeal Membrane Oxygenation , Cardiopulmonary Resuscitation/methods , Extracorporeal Membrane Oxygenation/methods , Intensive Care Units , Registries , Retrospective Studies , United States/epidemiology
14.
Geophys Res Lett ; 49(23): e2022GL099285, 2022 Dec 16.
Article in English | MEDLINE | ID: mdl-37034391

ABSTRACT

The Juno spacecraft has been in orbit around Jupiter since 2016. Two flybys of Ganymede were executed in 2021, opportunities realized by evolution of Juno's polar orbit over the intervening 5 years. The geometry of the close flyby just prior to the 34th perijove pass by Jupiter brought the spacecraft inside Ganymede's unique magnetosphere. Juno's payload, designed to study Jupiter's magnetosphere, had ample dynamic range to study Ganymede's magnetosphere. The Juno radio system was used both for gravity measurements and for study of Ganymede's ionosphere. Remote sensing of Ganymede returned new results on geology, surface composition, and thermal properties of the surface and subsurface.

15.
Geophys Res Lett ; 49(23): e2022GL098591, 2022 Dec 16.
Article in English | MEDLINE | ID: mdl-37034392

ABSTRACT

The Juno Waves instrument measured plasma waves associated with Ganymede's magnetosphere during its flyby on 7 June, day 158, 2021. Three distinct regions were identified including a wake, and nightside and dayside regions in the magnetosphere distinguished by their electron densities and associated variability. The magnetosphere includes electron cyclotron harmonic emissions including a band at the upper hybrid frequency, as well as whistler-mode chorus and hiss. These waves likely interact with energetic electrons in Ganymede's magnetosphere by pitch angle scattering and/or accelerating the electrons. The wake is accentuated by low-frequency turbulence and electrostatic solitary waves. Radio emissions observed before and after the flyby likely have their source in Ganymede's magnetosphere.

16.
J Geophys Res Space Phys ; 127(10): e2022JA030586, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36591321

ABSTRACT

The dynamics of the Jovian magnetosphere is controlled by the interplay of the planet's fast rotation, its solar-wind interaction and its main plasma source at the Io torus, mediated by coupling processes involving its magnetosphere, ionosphere, and thermosphere. At the ionospheric level, these processes can be characterized by a set of parameters including conductances, field-aligned currents, horizontal currents, electric fields, transport of charged particles along field lines including the fluxes of electrons precipitating into the upper atmosphere which trigger auroral emissions, and the particle and Joule heating power dissipation rates into the upper atmosphere. Determination of these key parameters makes it possible to estimate the net transfer of momentum and energy between Jovian upper atmosphere and equatorial magnetosphere. A method based on a combined use of Juno multi-instrument data and three modeling tools was developed by Wang et al. (2021, https://doi.org/10.1029/2021ja029469) and applied to an analysis of the first nine orbits to retrieve these parameters along Juno's magnetic footprint. We extend this method to the first 30 Juno science orbits and to both hemispheres. Our results reveal a large variability of these parameters from orbit to orbit and between the two hemispheres. They also show dominant trends. Southern current systems are consistent with the generation of a region of sub-corotating ionospheric plasma flows, while both super-corotating and sub-corotating plasma flows are found in the north. These results are discussed in light of the previous space and ground-based observations and currently available models of plasma convection and current systems, and their implications are assessed.

17.
Crit Care Explor ; 3(10): e0548, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34671745

ABSTRACT

OBJECTIVES: Inhaled epoprostenol is a continuously delivered selective pulmonary vasodilator that is used in patients with refractory hypoxemia, right heart failure, and postcardiac surgery pulmonary hypertension. Published data suggest that inhaled epoprostenol administration via vibrating mesh nebulizer systems may lead to unexpected interruptions in drug delivery. The frequency of these events is unknown. The objective of this study was to describe the incidence and clinical consequences of unexpected interruption in critically ill patients. DESIGN: Retrospective review and analysis. SETTING: Stanford University Hospital, a 605-bed tertiary care center. PATIENTS: Patients receiving inhaled epoprostenol in 2019. INTERVENTIONS: No interventions. MEASUREMENTS AND MAIN RESULTS: Clinical indication, duration of inhaled epoprostenol delivery, mode of respiratory support, and documented unexpected interruption. In 2019, there were 493 administrations of inhaled epoprostenol in 433 unique patients. Primary indications for inhaled epoprostenol were right heart dysfunction (n = 394; 79.9%) and hypoxemia (n = 92; 18.7%). Unexpected delivery interruptions occurred in 31 administrations (6.3%). Median duration of therapy prior to unexpected interruption was 2 days (interquartile range, 2-5 d). Respiratory support at the time of unexpected interruption was mechanical ventilation (61.3%), high-flow nasal cannula (35.5%), and noninvasive positive pressure ventilation (3.2%). Adverse sequelae of unexpected interruption included elevated pulmonary artery pressures (n = 12), systemic hypotension (n = 8), hypoxemia (n = 8), elevated central venous pressure (n = 4), and cardiac arrest (n = 1). Therapeutic interventions following unexpected interruption included initiation of inhaled nitric oxide (n = 21), increase in vasoactive medication (n = 2), and increase in respiratory support (n = 2). Most of the adverse events were Common Terminology Criteria for Adverse Events grade 3 and 4 (93.5%). CONCLUSIONS: A retrospective review of patients receiving inhaled epoprostenol via vibrating mesh nebulizer in 2019 revealed interruptions in 6.3% of administrations with most of these interruptions requiring therapeutic intervention. The true incidence of unexpected interruption and subsequent rate of unexpected interruption's requiring intervention is unknown due to the reliance on unexpected interruption identification and subsequent documentation in the electronic medical record. Sudden interruption in inhaled epoprostenol delivery can result in severe cardiopulmonary compromise, and on rare occasion, death.

18.
Anesth Analg ; 133(1): e12, 2021 07 01.
Article in English | MEDLINE | ID: mdl-34127602
19.
Rev Sci Tech ; 40(1): 253-259, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34140726

ABSTRACT

Biobanks represent a valuable resource in many areas of biomedical research and development. They function as repositories for well-documented and well-characterised biological material that can be used as the basis for this work. Virtual biobanks amplify the availability of this resource by linking multiple biobanks via a single interface. Test development and validation is an essential process that helps to provide confidence in diagnostic test results and, by extension, the disease and health status of animal populations demonstrated by such results. The quality of the development and validation pathway can be enhanced by the use of well-characterised material for standards and validation panels. Virtual biobanks represent a powerful mechanism for enhancing access to such material, and allow other parties to both have greater confidence in the work done, and to be able to repeat it themselves, as required.


Les biobanques constituent une ressource précieuse dans un grand nombre de domaines de la recherche et du développement biomédicaux. Elles servent d'archives destinées au stockage de matériels biologiques suffisamment documentés et caractérisés pour être utilisés comme éléments de base dans ces domaines. Les biobanques virtuelles opèrent comme multiplicateurs des ressources disponibles en reliant plusieurs biobanques sur une même interface. La mise au point et la validation des tests constituent un processus essentiel qui contribue à asseoir la confiance dans les résultats d'un test et, par voie de conséquence, dans le statut sanitaire d'une population animale tel qu'il ressort de ces résultats. La qualité du processus de développement et de validation peut être améliorée en faisant appel à des matériels bien caractérisés en tant que panels de référence et de validation. Les biobanques virtuelles sont un mécanisme puissant pour améliorer l'accès à ce type de matériels et permettent à d'autres intervenants d'avoir une plus grande confiance dans les travaux réalisés, et de pouvoir eux-mêmes les répéter, si besoin.


Los biobancos constituyen un recurso muy útil en numerosas vertientes de la labor de investigación y desarrollo (I+D) en biomedicina. Estos bancos funcionan como repositorios de material biológico bien descrito y caracterizado que cabe utilizar como base de dicha labor. Los biobancos virtuales, al vincular entre sí múltiples biobancos por medio de una única interfaz, ponen este recurso al alcance de muchos más usuarios. La creación y validación de pruebas analíticas es un proceso esencial, que ayuda a ofrecer confianza en los resultados de una prueba de diagnóstico y, por extensión, en la condición sanitaria de las poblaciones animales que dichos resultados indican. Es posible conferir mayor calidad al procedimiento de creación y validación utilizando muestras biológicas bien caracterizadas como material de referencia y para establecer paneles de validación. Los biobancos virtuales, amén de constituir un potente mecanismo para mejorar el acceso a material biológico, infunden a terceras partes mayor confianza en la labor realizada y permiten a estas partes replicar por sí mismas el proceso de ser necesario.


Subject(s)
Biological Specimen Banks , Biomedical Research , Animals , Indicators and Reagents
20.
Rev Sci Tech ; 40(1): 131-143, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34140735

ABSTRACT

Reproducibility is the ability of an assay to provide consistent results (when testing the same samples) in different laboratories. The validation of a new diagnostic assay should include specific assessment of assay reproducibility to determine the degree to which results are unaffected by minor changes in experimental conditions. Ideally, assessment of reproducibility involves the testing of identical samples in multiple laboratories by multiple analysts using the same method, reagents and controls, albeit with different equipment. Such an assessment will provide estimates of the precision and accuracy of an assay across laboratories. In reality, although the reproducibility of an assay is often assessed by multiple laboratories testing identical samples, the reagents, controls and testing platforms used, while similar, are usually not the same. Thus, reproducibility testing permits the assessment of variability resulting from different testing platforms, reagent supplies and operators. The determination of minor versus major variations in test conditions that may be anticipated in multi-laboratory use is part of the assessment at this stage of validation. Once validated, there are ongoing monitoring requirements to assess the performance characteristics and ensure they are consistently maintained. The use of quality assurance programmes is required, as this offers continued monitoring of assay performance by measuring the precision and accuracy of results for well-characterised samples and controls. Tests recommended by the World Organisation for Animal Health as fit for purpose are widely used internationally and need to have satisfactory reproducibility.


La reproductibilité d'un test désigne son aptitude à fournir des résultats constants (en testant les mêmes échantillons) lors d'analyses effectuées par différents laboratoires. Toute validation d'un nouvel essai diagnostique doit inclure une étape spécifique d'évaluation de la reproductibilité de l'essai, visant à vérifier jusqu'à quel point les résultats du test demeurent inchangés en cas de légères variations dans les conditions de réalisation de l'essai. Idéalement, l'évaluation de la reproductibilité consiste à soumettre des échantillons identiques à une même méthode d'essai réalisée dans plusieurs laboratoires par des analystes à chaque fois différents et en utilisant les mêmes réactifs et contrôles, mais avec des équipements différents. Une telle évaluation fournit une estimation de la précision et de l'exactitude d'un essai conduit par plusieurs laboratoires. Dans la pratique, si la reproductibilité d'un essai est souvent évaluée par des laboratoires différents à partir d'échantillons similaires, les réactifs, les contrôles et les plateformes d'essai ne sont généralement pas les mêmes d'un laboratoire à l'autre, bien qu'étant similaires. Les essais de reproductibilité permettent ainsi d'évaluer la variabilité induite par l'utilisation de plateformes de test et de réactifs différents par des opérateurs eux-mêmes différents. La détermination du caractère mineur ou substantiel des variations des conditions d'essai susceptibles d'être anticipées dans un cadre d'utilisation impliquant de nombreux laboratoires fait partie de l'évaluation à ce stade de la validation. Une fois la validation faite, des exigences de contrôle continu sont requises afin d'évaluer les caractéristiques de performances et de veiller à leur maintien dans le temps. Les laboratoires doivent se doter d'un programme d'assurance qualité qui garantisse le suivi continu des performances des essais à travers une mesure de la précision et de l'exactitude des résultats à partir d'échantillons et de contrôles bien caractérisés. Les tests dont l'aptitude à l'emploi selon l'objectif prévu a été établie et qui de ce fait sont recommandés par l'Organisation mondiale de la santé animale ont vocation à être utilisés dans le monde entier ; il est donc important qu'ils soient suffisamment reproductibles.


Se entiende por "reproducibilidad" el conjunto de características que permiten que un ensayo depare resultados uniformes al ser aplicado a las mismas muestras en laboratorios distintos. El proceso de validación de una prueba de diagnóstico debe incluir una evaluación específica de su reproducibilidad, a fin de determinar en qué medida los resultados se mantienen inalterados ante cambios menores de las condiciones experimentales. Lo idóneo para evaluar la reproducibilidad es que, en múltiples laboratorios, múltiples analistas sometan a prueba muestras idénticas empleando idénticos métodos, reactivos y controles, pero distinto equipo de laboratorio. Semejante evaluación permitirá estimar la precisión y exactitud que ofrece un ensayo en diferentes laboratorios. En realidad, aunque en la evaluación de la reproducibilidad de un ensayo intervienen a menudo múltiples laboratorios que analizan muestras idénticas, los reactivos, controles y dispositivos de prueba utilizados, aún siendo parecidos, no suelen los mismos. La realización de pruebas de reproducibilidad permite pues determinar la variabilidad que introducen distintos dispositivos de prueba, suministros de reactivos y técnicos de laboratorio. Así, la determinación de las variaciones menores frente a las variaciones importantes de las condiciones experimentales que cabe prever cuando múltiples laboratorios emplean un ensayo forma parte de la evaluación en esta fase del proceso de validación. Una vez validado un ensayo, hay una serie de requisitos de seguimiento continuo que sirven para evaluar las características de rendimiento y garantizar que se mantengan estables en el tiempo. Para ello es necesario utilizar programas de garantía de calidad, que ofrecen la posibilidad de hacer un seguimiento continuo del rendimiento de un ensayo cuantificando la precisión y exactitud de los resultados obtenidos con muestras y controles bien caracterizados. Las pruebas que la Organización Mundial de Sanidad Animal recomienda por considerarlas adaptadas a su finalidad, de uso muy extendido a escala internacional, deben presentar un nivel satisfactorio de reproducibilidad.


Subject(s)
Laboratories , Animals , Reproducibility of Results