Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Opt Soc Am A Opt Image Sci Vis ; 34(5): A37-A46, 2017 05 01.
Article in English | MEDLINE | ID: mdl-28463332

ABSTRACT

High angular resolution studies of stars in the optical domain have highly progressed in recent years. After the results obtained with the visible instrument Visible spEctroGraph and polArimeter (VEGA) on the Center for High Angular Resolution Astronomy (CHARA) array and the recent developments on adaptive optics and fibered interferometry, we have started the design and study of a new six-telescope visible combiner with single-mode fibers. It is designed as a low spectral resolution instrument for the measurement of the angular diameter of stars to make a major step forward in terms of magnitude and precision with respect to the present situation. For a large sample of bright stars, a medium spectral resolution mode will allow unprecedented spectral imaging of stellar surfaces and environments for higher accuracy on stellar/planetary parameters. To reach the ultimate performance of the instrument in terms of limiting magnitude (Rmag≃8 for diameter measurements and Rmag≃4 to 5 for imaging), Stellar Parameters and Images with a Cophased Array (SPICA) includes the development of a dedicated fringe tracking system in the H band to reach "long" (200 ms to 30 s) exposures of the fringe signal in the visible.

2.
Appl Opt ; 47(8): 1141-51, 2008 Mar 10.
Article in English | MEDLINE | ID: mdl-18327288

ABSTRACT

Algol and Comptage de Photons Nouvelle Génération (CPNG) are new generation photon counting cameras developed for high angular resolution in the visible by means of optical aperture synthesis and speckle interferometry and for photon noise limited fast imaging of biological targets. They are intensified CCDs. They have been built to benefit from improvements in photonic commercial components, sensitivity, and personal computer workstations processing power. We present how we achieve optimal performances (sensitivity and spatiotemporal resolution) by the combination of proper optical and electronics design, and real-time elaborated data processing. The number of pixels is 532 x 516 and 1024(2) read at a frame rate of 262 and 100 Hz for CPNG and Algol, respectively. The dark current is very low: 5.5 x 10(-4) e(-) .pixel(-1). s(-1). The saturation flux is approximately 7 photon events /pixel/s. Quantum efficiencies reach up to 36% and 26% in the visible with the GaAsP photocathodes and in the red with the GaAs ones, respectively, thanks to the sensitivity of the photocathodes and to the photon centroiding algorithm; they are likely the highest values reported for intensified CCDs.

SELECTION OF CITATIONS
SEARCH DETAIL
...