Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Acad Emerg Med ; 31(6): 564-575, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38497320

ABSTRACT

OBJECTIVES: We previously described derivation and validation of the emergency department trigger tool (EDTT) for adverse event (AE) detection. As the first step in our multicenter study of the tool, we validated our computerized screen for triggers against manual review, establishing our use of this automated process for selecting records to review for AEs. METHODS: This is a retrospective observational study of visits to three urban, academic EDs over 18 months by patients ≥ 18 years old. We reviewed 912 records: 852 with at least one of 34 triggers found by the query and 60 records with none. Two first-level reviewers per site each manually screened for triggers. After completion, computerized query results were revealed, and reviewers could revise their findings. Second-level reviewers arbitrated discrepancies. We compare automated versus manual screening by positive and negative predictive values (PPVs, NPVs), present population trigger frequencies, proportions of records triggered, and how often manual ratings were changed to conform with the query. RESULTS: Trigger frequencies ranged from common (>25%) to rare (1/1000) were comparable at U.S. sites and slightly lower at the Canadian site. Proportions of triggered records ranged from 31% to 49.4%. Overall query PPV was 95.4%; NPV was 99.2%. PPVs for individual trigger queries exceeded 90% for 28-31 triggers/site and NPVs were >90% for all but three triggers at one site. Inter-rater reliability was excellent, with disagreement on manual screening results less than 5% of the time. Overall, reviewers amended their findings 1.5% of the time when discordant with query findings, more often when the query was positive than when negative (47% vs. 23%). CONCLUSIONS: The EDTT trigger query performed very well compared to manual review. With some expected variability, trigger frequencies were similar across sites and proportions of triggered records ranged 31%-49%. This demonstrates the feasibility and generalizability of implementing the EDTT query, providing a solid foundation for testing the triggers' utility in detecting AEs.


Subject(s)
Emergency Service, Hospital , Adult , Female , Humans , Male , Middle Aged , Canada , Emergency Service, Hospital/statistics & numerical data , Medical Errors/statistics & numerical data , Reproducibility of Results , Retrospective Studies , United States
2.
CMAJ ; 182(11): 1173-9, 2010 Aug 10.
Article in English | MEDLINE | ID: mdl-20457772

ABSTRACT

OBJECTIVES: The Canadian C-Spine Rule for imaging of the cervical spine was developed for use by physicians. We believe that nurses in the emergency department could use this rule to clinically clear the cervical spine. We prospectively evaluated the accuracy, reliability and acceptability of the Canadian C-Spine Rule when used by nurses. METHODS: We conducted this three-year prospective cohort study in six Canadian emergency departments. The study involved adult trauma patients who were alert and whose condition was stable. We provided two hours of training to 191 triage nurses. The nurses then assessed patients using the Canadian C-Spine Rule, including determination of neck tenderness and range of motion, reapplied immobilization and completed a data form. RESULTS: Of the 3633 study patients, 42 (1.2%) had clinically important injuries of the cervical spine. The kappa value for interobserver assessments of 498 patients with the Canadian C-Spine Rule was 0.78. We calculated sensitivity of 100.0% (95% confidence interval [CI] 91.0%-100.0%) and specificity of 43.4% (95% CI 42.0%-45.0%) for the Canadian C-Spine Rule as interpreted by the investigators. The nurses classified patients with a sensitivity of 90.2% (95% CI 76.0%-95.0%) and a specificity of 43.9% (95% CI 42.0%-46.0%). Early in the study, nurses failed to identify four cases of injury, despite the presence of clear high-risk factors. None of these patients suffered sequelae, and after retraining there were no further missed cases. We estimated that for 40.7% of patients, the cervical spine could be cleared clinically by nurses. Nurses reported discomfort in applying the Canadian C-Spine Rule in only 4.8% of cases. CONCLUSION: Use of the Canadian C-Spine Rule by nurses was accurate, reliable and clinically acceptable. Widespread implementation by nurses throughout Canada and elsewhere would diminish patient discomfort and improve patient flow in overcrowded emergency departments.


Subject(s)
Cervical Vertebrae/diagnostic imaging , Nursing Staff, Hospital , Spinal Injuries/diagnostic imaging , Triage , Adolescent , Adult , Aged , Aged, 80 and over , Canada , Emergency Service, Hospital , Female , Humans , Male , Middle Aged , Radiography , Reproducibility of Results , Workforce , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...