1.
J Appl Clin Med Phys ; 17(2): 341-367, 2016 03 08.
Article in English | MEDLINE | ID: mdl-27074458

ABSTRACT

VMAT is a powerful technique to deliver hypofractionated prostate treatments. The lack of correlations between usual 2D pretreatment QA results and the clinical impact of possible mistakes has allowed the development of 3D verification systems. Dose determination on patient anatomy has provided clinical predictive capability to patient-specific QA process. Dose-volume metrics, as evaluation criteria, should be replaced or complemented by radiobiological indices. These metrics can be incorporated into individualized QA extracting the information for response parameters (gEUD, TCP, NTCP) from DVHs. The aim of this study is to assess the role of two 3D verification systems dealing with radiobiological metrics applied to a prostate VMAT QA program. Radiobiological calculations were performed for AAPM TG-166 test cases. Maximum differences were 9.3% for gEUD, -1.3% for TCP, and 5.3% for NTCP calculations. Gamma tests and DVH-based comparisons were carried out for both systems in order to assess their performance in 3D dose determination for prostate treatments (high-, intermediate-, and low-risk, as well as prostate bed patients). Mean gamma passing rates for all structures were bet-ter than 92.0% and 99.1% for both 2%/2 mm and 3%/3 mm criteria. Maximum discrepancies were (2.4% ± 0.8%) and (6.2% ± 1.3%) for targets and normal tis-sues, respectively. Values for gEUD, TCP, and NTCP were extracted from TPS and compared to the results obtained with the two systems. Three models were used for TCP calculations (Poisson, sigmoidal, and Niemierko) and two models for NTCP determinations (LKB and Niemierko). The maximum mean difference for gEUD calculations was (4.7% ± 1.3%); for TCP, the maximum discrepancy was (-2.4% ± 1.1%); and NTCP comparisons led to a maximum deviation of (1.5% ± 0.5%). The potential usefulness of biological metrics in patient-specific QA has been explored. Both systems have been successfully assessed as potential tools for evaluating the clinical outcome of a radiotherapy treatment in the scope of pretreatment QA.


Subject(s)
Algorithms , Brain Neoplasms/radiotherapy , Head and Neck Neoplasms/radiotherapy , Prostatic Neoplasms/radiotherapy , Quality Assurance, Health Care , Radiobiology , Radiotherapy, Intensity-Modulated/methods , Humans , Imaging, Three-Dimensional/methods , Male , Models, Statistical , Phantoms, Imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods
2.
J Appl Clin Med Phys ; 16(2): 5190, 2015 Mar 08.
Article in English | MEDLINE | ID: mdl-26103189

ABSTRACT

A pretreatment quality assurance program for volumetric techniques should include redundant calculations and measurement-based verifications. The patient-specific quality assurance process must be based in clinically relevant metrics. The aim of this study was to show the commission, clinical implementation, and comparison of two systems that allow performing a 3D redundant dose calculation. In addition, one of them is capable of reconstructing the dose on patient anatomy from measurements taken with a 2D ion chamber array. Both systems were compared in terms of reference calibration data (absolute dose, output factors, percentage depth-dose curves, and profiles). Results were in good agreement for absolute dose values (discrepancies were below 0.5%) and output factors (mean differences were below 1%). Maximum mean discrepancies were located between 10 and 20 cm of depth for PDDs (-2.7%) and in the penumbra region for profiles (mean DTA of 1.5 mm). Validation of the systems was performed by comparing point-dose measurements with values obtained by the two systems for static, dynamic fields from AAPM TG-119 report, and 12 real VMAT plans for different anatomical sites (differences better than 1.2%). Comparisons between measurements taken with a 2D ion chamber array and results obtained by both systems for real VMAT plans were also performed (mean global gamma passing rates better than 87.0% and 97.9% for the 2%/2 mm and 3%/3 mm criteria). Clinical implementation of the systems was evaluated by comparing dose-volume parameters for all TG-119 tests and real VMAT plans with TPS values (mean differences were below 1%). In addition, comparisons between dose distributions calculated by TPS and those extracted by the two systems for real VMAT plans were also performed (mean global gamma passing rates better than 86.0% and 93.0% for the 2%/2 mm and 3%/ 3 mm criteria). The clinical use of both systems was successfully evaluated.


Subject(s)
Head and Neck Neoplasms/radiotherapy , Prostatic Neoplasms/radiotherapy , Quality Assurance, Health Care , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/standards , Radiotherapy, Intensity-Modulated/standards , Stomach Neoplasms/radiotherapy , Humans , Male , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/instrumentation