Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Adhes Dent ; 16(5): 441-50, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25202747

ABSTRACT

PURPOSE: To directly test the effectiveness of ethanol-wet bonding (EW) in improving monomer infiltration into demineralized dentin through quantitative measurement of bis-GMA and TEG-DMA molar concentrations within hybrid layers, and to comprehensively evaluate the effect of EW and chlorhexidine on durability of resin-dentin bonds compared to conventional water-wet bonding (WW). MATERIALS AND METHODS: A three-step etch-and-rinse adhesive (70% bis-GMA/28.75%TEG-DMA) was applied to coronal dentin using a clinically relevant ethanol-wet bonding protocol (EW) or the conventional water-wet bonding (WW) technique. Bis-GMA and TEG-DMA molar concentrations at various positions across the resin/dentin interfaces formed by EW and WW were measured using micro-Raman spectroscopy. The experiment was repeated at the same positions after 7-month storage in phosphate buffer solution containing 0.1% sodium azide. The µTBS and hybrid layer morphology (TEM) of bonding groups with and without chlorhexidine application were compared immediately and after 1-year storage in terms of nanoleakage, collagen fibril diameter, collagen interfibrillar width, and hybrid layer thickness. RESULTS: Specimens bonded with EW showed significantly higher monomer molar concentrations and µTBS throughout the hybrid layer immediately and after storage, providing direct evidence of superior infiltration of hydrophobic monomers in EW compared to WW. Microscopically, EW maintained interfibrillar width and hybrid layer thickness for resin infiltration and retention. The application of chlorhexidine further preserved collagen integrity and limited the degree of nanoleakage in EW after 1-year storage. CONCLUSION: EW enhances infiltration of hydrophobic monomers into demineralized dentin. The results suggest that a more durable resin-dentin bond may be achieved with combined usage of a clinically relevant EW and chlorhexidine.


Subject(s)
Chlorhexidine/chemistry , Composite Resins/chemistry , Dental Bonding/methods , Dental Materials/chemistry , Dentin/ultrastructure , Ethanol/chemistry , Matrix Metalloproteinase Inhibitors/chemistry , Solvents/chemistry , Acid Etching, Dental/methods , Bisphenol A-Glycidyl Methacrylate/chemistry , Collagen/ultrastructure , Dental Leakage/classification , Humans , Hydrophobic and Hydrophilic Interactions , Materials Testing , Polyethylene Glycols/chemistry , Polymethacrylic Acids/chemistry , Silicon Dioxide/chemistry , Spectrum Analysis, Raman/methods , Stress, Mechanical , Surface Properties , Tensile Strength , Time Factors , Water/chemistry , Zirconium/chemistry
2.
J Prosthet Dent ; 112(4): 864-70, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24969410

ABSTRACT

STATEMENT OF PROBLEM: Information regarding the differences in translucency among new ceramic systems is lacking. PURPOSE: The purpose of this study was to compare the relative translucency of the different types of ceramic systems indicated for porcelain veneers and to evaluate the effect of shade and thickness on translucency. MATERIAL AND METHODS: Disk specimens 13 mm in diameter and 0.7-mm thick were fabricated for the following 9 materials (n=5): VITA VM9, IPS Empress Esthetic, VITA PM9, Vitablocks Mark II, Kavo Everest G-Blank, IPS Empress CAD, IPS e.max CAD, IPS e.maxPress, and Lava Zirconia. VITA VM9 served as the positive control and Lava as the negative control. The disks were fabricated with the shade that corresponds to A1. For IPS e.maxPress, additional disks were made with different shades (BL2, BL4, A1, B1, O1, O2, V1, V2, V3), thickness (0.3 mm), and translucencies (high translucency, low translucency). Color coordinates (CIE L∗ a∗ b∗) were measured with a tristimulus colorimeter. The translucency parameter was calculated from the color difference of the material on a black versus a white background. One-way ANOVA, the post hoc Tukey honestly significant difference, and the Ryan-Einot-Gabriel-Welsch multiple range tests were used to analyze the data (α=.05). RESULTS: Statistically significant differences in the translucency parameter were found among porcelains (P<.001) according to the following rank: VM9>PM9, Empress Esthetic>Empress CAD>Mark II, Everest, e.max CAD>e.max Press>Lava. Significant differences also were noted when different shades and thickness were compared (P<.001). CONCLUSIONS: Different ceramic systems designed for porcelain veneers present varying degrees of translucency. The thickness and shade of lithium disilicate ceramic affect its translucency. Shade affects translucency parameter less than thickness.


Subject(s)
Ceramics/chemistry , Dental Materials/chemistry , Dental Porcelain/chemistry , Dental Veneers , Aluminum Silicates/chemistry , Color , Colorimetry/instrumentation , Humans , Light , Materials Testing , Potassium Compounds/chemistry , Prosthesis Coloring , Surface Properties
3.
J Prosthet Dent ; 110(5): 397-401, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23998620

ABSTRACT

STATEMENT OF PROBLEM: Different parameters are used in the literature to describe translucency, making it difficult for clinicians to find clear information on ceramic translucency and compare studies. PURPOSE: The purpose of this study was to assess the correlation between the contrast ratio (CR) and translucency parameter (TP) when the translucency of different types of ceramic systems is compared. MATERIAL AND METHODS: Disks 13 mm in diameter and 0.7 mm thick were fabricated for the following materials (n=5): VITA VM9, VITA PM9, IPS Empress CAD, IPS e.max CAD, IPS e.maxPress, and Lava Zirconia. VITA VM9 served as positive control, while Lava Zirconia served as negative control. The luminous reflectance (Y) and color coordinates (CIE L* a* b*) of the specimens were measured with a tristimulus colorimeter. The CR (CR=Yb/Yw) was calculated from the reflectance of the light of the material on a black backing (Yb) to the reflectance on a white backing (Yw). The TP (TP=[(Lb*Lw*)(2+)(ab*-aw*)(2+)(bb*-bw*)(2) ](1/2)) was calculated from the color difference of the material on a black versus a white background. One-way ANOVA based on ranked data and the Pearson and Spearman rank correlation tests were used to analyze the data (α=.05). RESULTS: A significant correlation between CR and TP was found when all specimens were included (P<.001). The coefficient of -0.99 indicated a strong decreasing relationship between the 2 variables. CONCLUSIONS: Either CR or TP can be used to evaluate the relative translucency of ceramic systems.


Subject(s)
Ceramics/chemistry , Dental Porcelain/chemistry , Dental Veneers , Aluminum Silicates/chemistry , Color , Colorimetry/instrumentation , Computer-Aided Design , Dental Materials/chemistry , Dental Polishing/methods , Humans , Light , Materials Testing , Potassium Compounds/chemistry , Prosthesis Coloring , Surface Properties , Zirconium/chemistry
4.
J Esthet Restor Dent ; 25(2): 125-38, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23617387

ABSTRACT

PROBLEM: Polishing composite resin restorations may lead to marginal defects and gap formation. PURPOSE: To assess the effect of polishing direction on the marginal adaptation of composite resin restorations using two composite resins and two polishing systems. MATERIALS AND METHODS: Forty extracted human molars were sectioned along their mesio-distal axis. Buccal and lingual enamel was flattened and a triangular preparation, 0.87-mm deep and 3-mm wide, representing two 60° bevels, was performed. Specimens were randomly assigned to eight groups (N = 20) and restored with two composite resins: a nanofilled (Filtek Supreme Ultra, 3M ESPE, St. Paul, MN, USA) or a microhybrid (Point 4, Kerr, Orange, CA, USA) and finished with two polishing techniques: polishing discs (Sof-Lex XT, 3M ESPE) or rubber polishers (HiLuster Plus, Kerr, Bioggio, Switzerland). On each specimen, both margins were polished with the same technique, one margin from composite resin to tooth and the other from tooth to composite resin. Replicas were made for field emission scanning electron microscope observation (200×) and quantitative margin analysis was performed based on four criteria. Data were analyzed with a paired-sample t-test, a two-sample t-test, and one-way analysis of variance or their nonparametric analog. RESULTS: Significant differences were found in most groups between polishing directions with better marginal adaptation from composite resin to tooth than from tooth to composite resin. Differences between composite resins and polishing techniques seemed to be dependent on certain combinations of composite resin, polishing technique, and polishing direction. CONCLUSION: Polishing from composite resin to tooth leads to better marginal adaptation than polishing from tooth to composite resin. CLINICAL SIGNIFICANCE: The results obtained from this in vitro study suggest that polishing direction influences the marginal adaptation of composite resins and that polishing from composite resin to tooth structure should be clinically performed whenever possible on accessible margins to preserve marginal integrity and esthetics.


Subject(s)
Composite Resins/chemistry , Dental Marginal Adaptation , Dental Materials/chemistry , Dental Polishing/methods , Dental Restoration, Permanent , Humans
5.
J Dent Educ ; 76(6): 695-704, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22659697

ABSTRACT

This study aimed to better understand how and why people choose dental school faculty members as their oral health care providers. Increasing financial constraints in U.S. dental schools have led their administrators to seek alternative funding sources, one of which can be revenues from dental school faculty practice. To effectively promote faculty practice, it is necessary to understand how and why one chooses a dental school faculty member as his or her oral health care provider. A survey of 1,150 dental school faculty practice patients who recently chose their dentist was conducted, and 221 responded. The information sources these respondents said they used and rated highly were other dentists, friends, family members, clinic website, the Internet, and the insurance directory. Dentist-related attributes that were perceived to be important were quality of care, professional competence of dentist, and explanation of treatment/patient participation in the treatment decision. Dental practice-related attributes perceived to be important were the ability to get appointments at convenient times, reasonable waiting time to get appointments, and attitude/helpfulness of staff. This study found that traditionally popular (family, friends) and newly emerging information sources (the Internet, clinic website, and insurance directory) were both used and perceived to be important by patients of the dental school faculty practice. Dental schools and dentists can use this study's findings to select appropriate communication channels to promote their practices and to focus on attributes that dental consumers value the most.


Subject(s)
Choice Behavior , Dentist-Patient Relations , Dentists , Marketing of Health Services , Patient Preference , Adolescent , Adult , Aged , Aged, 80 and over , Decision Making , Dental Clinics/organization & administration , Faculty, Dental , Female , Humans , Information Seeking Behavior , Iowa , Male , Middle Aged , Schools, Dental/economics , Surveys and Questionnaires , Young Adult
6.
J Dent Educ ; 75(6): 823-31, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21642529

ABSTRACT

Written and clinical tests compared the change in clinical knowledge and practical clinical skill of first-year dental students watching a clinical video recording of the three-step etch-and-rinse resin bonding system to those using an interactive dental video game teaching the same procedure. The research design was a randomized controlled trial with eighty first-year dental students enrolled in the preclinical operative dentistry course. Students' change in knowledge was measured through written examination using a pre-test and a post-test, as well as clinical tests in the form of a benchtop shear bond strength test. There was no statistically significant difference between teaching methods in regards to change in either knowledge or clinical skills, with one minor exception relating to the wetness of dentin following etching. Students expressed their preference for an interactive self-paced method of teaching.


Subject(s)
Computer-Assisted Instruction , Dental Bonding , Dentistry, Operative/education , Education, Dental/methods , Video Games , Adult , Chi-Square Distribution , Computer Simulation , Dental Stress Analysis , Dentin-Bonding Agents , Female , Humans , Iowa , Male , Program Evaluation , Shear Strength , Statistics, Nonparametric , Surveys and Questionnaires , User-Computer Interface , Video Recording , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...