Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Semin Thorac Cardiovasc Surg ; 13(4): 333-41, 2001 Oct.
Article in English | MEDLINE | ID: mdl-11807732

ABSTRACT

The study of the dissemination of the electric impulse throughout the ventricular myocardium, which gave rise to the current theories, was performed without taking into consideration the complex architecture of the cardiac muscle elucidated by more recent researchers. We propose a novel hypothesis based on the special macroscopic structure of the heart, the anisotropic electric and mechanical behavior of the myocardium, the characteristics of the intercellular matrix and its very special collagen scaffolding, chemical composition, and biochemistry. The unique properties of the intercellular matrix would make it especially suited to function, in conjunction with the specialized conducting system (His-Purkinje system), as an efficient anisotropic conductor for the spread of electric activation in the heart, and to allow an optimal sequence of excitation-contraction coupling that results in the coordination of effective myocardial contraction in birds and mammals of the most varied known heart rates.


Subject(s)
Extracellular Matrix/physiology , Heart Conduction System/anatomy & histology , Heart Conduction System/physiology , Heart/anatomy & histology , Heart/physiology , Animals , Electrophysiology , Hemodynamics/physiology , Humans , Models, Cardiovascular , Myocardium/ultrastructure
2.
IEEE Trans Biomed Eng ; 44(10): 909-20, 1997 Oct.
Article in English | MEDLINE | ID: mdl-9311160

ABSTRACT

This paper describes a single-channel implantable microstimulator for functional neuromuscular stimulation. This device measures 2 x 2 x 10 mm3 and can be inserted into paralyzed muscle groups by expulsion from a hypodermic needle. Power and data to the device are supplied from outside by RF telemetry using an amplitude-modulated 2-MHz RF carrier generated using a high-efficiency class-E transmitter. The transmitted signal carries a 5-b address which selects one of the 32 possible microstimulators. The selected device then delivers up to 2 microC of charge store in a tantalum chip capacitor for up to 200 microseconds (10 mA) into loads of < 800 omega through a high-current thin-film iridium-oxide (IrOx) electrode (approximately 0.3 mm2 in area). A bi-CMOS receiver circuitry is used to: generate two regulated voltage supplies (4.5 and 9 V), recover a 2-MHz clock from the carrier, demodulate the address code, and activate the output current delivery circuitry upon the reception of an external command. The overall power dissipation of the receiver circuitry is 45-55 mW. The implant is hermetically packaged using a custom-made glass capsule.


Subject(s)
Electric Stimulation Therapy/instrumentation , Electronics, Medical/instrumentation , Equipment Design , Humans , Microelectrodes , Neuromuscular Diseases/therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...