Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 14(1): 4452, 2024 02 23.
Article in English | MEDLINE | ID: mdl-38396005

ABSTRACT

To carry out the preclinical and histological evaluation of a novel nanotechnology-based microshunt for drainage glaucoma surgery. Twelve New Zealand White rabbits were implanted with a novel microshunt and followed up for 6 weeks. The new material composite consists of the silicone polydimethylsiloxane (PDMS) and tetrapodal Zinc Oxide (ZnO-T) nano-/microparticles. The microshunts were inserted ab externo to connect the subconjunctival space with the anterior chamber. Animals were euthanized after 2 and 6 weeks for histological evaluation. Ocular health and implant position were assessed at postoperative days 1, 3, 7 and twice a week thereafter by slit lamp biomicroscopy. Intraocular pressure (IOP) was measured using rebound tonometry. A good tolerability was observed in both short- and medium-term follow-up. Intraocular pressure was reduced following surgery but increased to preoperative levels after 2 weeks. No clinical or histological signs of inflammatory or toxic reactions were seen; the fibrotic encapsulation was barely noticeable after two weeks and very mild after six weeks. The new material composite PDMS/ZnO-T is well tolerated and the associated foreign body fibrotic reaction quite mild. The new microshunt reduces the IOP for 2 weeks. Further research will elucidate a tube-like shape to improve and prolong outflow performance and longer follow-up to exclude medium-term adverse effects.


Subject(s)
Glaucoma Drainage Implants , Glaucoma , Zinc Oxide , Animals , Rabbits , Glaucoma Drainage Implants/adverse effects , Glaucoma/surgery , Glaucoma/etiology , Intraocular Pressure , Tonometry, Ocular , Anterior Chamber/surgery , Nanotechnology
2.
ACS Biomater Sci Eng ; 9(3): 1352-1361, 2023 03 13.
Article in English | MEDLINE | ID: mdl-36776118

ABSTRACT

The glaucoma burden increases continuously and is estimated to affect more than 100 million people by 2040. As there is currently no cure to restore the optic nerve damage caused by glaucoma, the only controllable parameter is the intraocular pressure (IOP). In recent years, minimally invasive glaucoma surgery (MIGS) has emerged as an alternative to traditional treatments. It uses micro-sized drainage stents that are inserted through a small incision, minimizing the trauma to the tissue and reducing surgical and postoperative recovery time. However, a major challenge for MIGS devices is foreign body reaction and fibrosis, which can lead to a complete failure of the device. In this work, the antifibrotic potential of tetrapodal ZnO (t-ZnO) microparticles used as an additive is elucidated by using rat embryonic fibroblasts as a model. A simple, direct solvent-free process for the fabrication of stents with an outer diameter of 200-400 µm is presented, in which a high amount of t-ZnO particles (45-75 wt %) is mixed into polydimethylsiloxane (PDMS) and a highly viscous polymer/particle mixture is extruded. The fabricated stents possess increased elastic modulus compared to pure PDMS while remaining flexible to adapt to the curvature of an eye. In vitro experiments showed that the fibroblast cell viability was inhibited to 43 ± 3% when stents with 75 wt % t-ZnO were used. The results indicate that cell inhibiting properties can be attributed to an increased amount of protruding t-ZnO particles on the stent surface, leading to an increase in local contacts with cells and a disruption of the cell membrane. As a secondary mechanism, the released Zn ions could also contribute to the cell-inhibiting properties in the close vicinity of the stent surface. Overall, the fabrication method and the antifibrotic and mechanical properties of developed stents make them promising for application in MIGS.


Subject(s)
Glaucoma , Stents , Glaucoma/surgery , Minimally Invasive Surgical Procedures/methods , Animals , Rats , Zinc Oxide
3.
Life (Basel) ; 12(11)2022 Oct 24.
Article in English | MEDLINE | ID: mdl-36362846

ABSTRACT

Glaucoma filtering surgery is applied to reduce intraocular pressure (IOP) in cases of uncontrolled glaucoma. However, postoperative fibrosis reduces the long-term success of both standard trabeculectomy and microstents. The aim of this study was to test the antiproliferative and anti-inflammatory potential of ZnO-tetrapods (ZnO-T) on human Tenon's fibroblasts (HTFs) for glaucoma surgery. The toxicity of ZnO-T on HTFs was determined using an MTT test. For analysis of fibroblast proliferation, migration, and transdifferentiation, cultures were stained for Ki67, alpha-smooth muscle actin (α-SMA), and p-SMAD. A fully quantitative multiplex ELISA was used to determine the concentrations of different cytokines, platelet-derived growth factor (PDGF), and hepatocyte growth factor (HGF) in culture supernatants with and without previous ZnO-T treatment. Treatment with higher concentrations (10 and 20 µg/mL) was associated with HTF toxicity, as shown in the wound healing assay. Furthermore, the number of Ki67, α-SMA-positive, and pSMAD-positive cells, as well as IL-6 and HGF in supernatants, were significantly reduced following incubation with ZnO-T. In conclusion, we were able to show the antiproliferative and anti-inflammatory potentials of ZnO-T. Therefore, the use of ZnO-T may provide a new approach to reducing postoperative fibrosis in glaucoma filtering surgery.

4.
Life (Basel) ; 12(11)2022 Nov 07.
Article in English | MEDLINE | ID: mdl-36362958

ABSTRACT

In our previous study we were able to show that zinc oxide (ZnO) tetrapods inhibit wound healing processes. Therefore, the aim of this study was to test the antiproliferative effect of two types of porous polydimethylsiloxane (PDMS)/ tetrapodal zinc oxide (ZnO-T) materials, as well as their usability for glaucoma implants. To find the best implant material, two different porous PDMS/ZnO-T materials were examined. One consisted of 3D interconnected PDMS coarse-pored foams with protruding ZnO-T particles; the other consisted of fine-pored 3D interconnected ZnO-T networks homogeneously coated by a thin PDMS film in the nanometer range. Fibroblast cell viability was investigated for both materials via MTT dye, and some implant material samples were further processed for electron microscopy. Both PDMS/ZnO-T materials showed reduced cell viability in the MTT staining. Furthermore, the electron microscopy revealed barely any fibroblasts growing on the implant materials. At the surface of the fine-pored implant material, however, fibroblasts could not be observed in the etched control samples without ZnO-T. It was found that post-processing of the material to the final stent diameter was highly challenging and that the fabrication method, therefore, had to be adapted. In conclusion, we were able to demonstrate the antiproliferative potential of the two different PDMS/ZnO-T materials. Furthermore, smaller pore size (in the range of tens of micrometers) in the implant material seems to be preferable.

5.
Nanoscale Res Lett ; 5(9): 1502-1506, 2010 Jun 15.
Article in English | MEDLINE | ID: mdl-20730118

ABSTRACT

The growing demand for electro mobility together with advancing concepts for renewable energy as primary power sources requires sophisticated methods of energy storage. In this work, we present a Li ion battery based on Si nanowires, which can be produced reliable and cheaply and which shows superior properties, such as a largely increased capacity and cycle stability. Sophisticated methods based on electrochemical pore etching allow to produce optimized regular arrays of nanowires, which can be stabilized by intrinsic cross-links, which serve to avoid unwanted stiction effects and allow easy processing.

SELECTION OF CITATIONS
SEARCH DETAIL
...