Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Publication year range
1.
Opt Express ; 23(24): 31206-15, 2015 Nov 30.
Article in English | MEDLINE | ID: mdl-26698749

ABSTRACT

We demonstrate a compact, robust, and stable terahertz source based on a novel two section digital distributed feedback laser diode and plasmonic photomixer. Terahertz wave generation is achieved through difference frequency generation by pumping the plasmonic photomixer with two output optical beams of the two section digital distributed feedback laser diode. The laser is designed to offer an adjustable terahertz frequency difference between the emitted wavelengths by varying the applied currents to the laser sections. The plasmonic photomixer is comprised of an ultrafast photoconductor with plasmonic contact electrodes integrated with a logarithmic spiral antenna. We demonstrate terahertz wave generation with 0.15-3 THz frequency tunability, 2 MHz linewidth, and less than 5 MHz frequency stability over 1 minute, at useful power levels for practical imaging and sensing applications.


Subject(s)
Lasers, Semiconductor , Lighting/instrumentation , Optical Devices , Refractometry/instrumentation , Surface Plasmon Resonance/instrumentation , Terahertz Imaging/instrumentation , Equipment Design , Equipment Failure Analysis , Terahertz Radiation
2.
J Mech Behav Biomed Mater ; 4(7): 1421-30, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21783152

ABSTRACT

In this work, a multi-elementary Ti-10Zr-5Nb-5Ta alloy, with non-toxic alloying elements, was used to develop an accumulative roll bonding, ARB-type procedure in order to improve its structural and mechanical properties. The alloy was obtained by cold crucible semi-levitation melting technique and then was ARB deformed following a special route. After three ARB cycles, the total deformation degree per layer is about 86%; the calculated medium layer thickness is about 13 µm. The ARB processed alloy has a low Young's modulus of 46 GPa, a value very close to the value of the natural cortical bone (about 20 GPa). Data concerning ultimate tensile strength obtained for ARB processed alloy is rather high, suitable to be used as a material for bone substitute. Hardness of the ARB processed alloy is higher than that of the as-cast alloy, ensuring a better behaviour as a implant material. The tensile curve for the as-cast alloy shows an elastoplastic behaviour with a quite linear elastic behaviour and the tensile curve for the ARB processed alloy is quite similar with a strain-hardening elastoplastic body. Corrosion behaviour of the studied alloy revealed the improvement of the main electrochemical parameters, as a result of the positive influence of ARB processing. Lower corrosion and ion release rates for the ARB processed alloy than for the as-cast alloy, due to the favourable effect of ARB thermo-mechanical processing were obtained.


Subject(s)
Alloys/chemistry , Coated Materials, Biocompatible/chemistry , Mechanical Phenomena , Nanostructures/chemistry , Corrosion , Niobium/chemistry , Tantalum/chemistry , Titanium/chemistry , Zirconium/chemistry
3.
J Mater Sci Mater Med ; 21(6): 1959-68, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20336353

ABSTRACT

One objective of this work was to study the corrosion resistance of the new implant Ti-10Zr-5Ta-5Nb alloy in physiological fluids of different pH values, simulating the extreme functional conditions. Another objective was in vitro biocompatibility evaluation of the new alloy using human fetal osteoblast cell line hFOB 1.19. Cytocompatibility was assessed by determination of possible material cytotoxic effects, cell morphology and cell adhesion. The thermo-mechanical processing of the new implant alloy consisted in plastic deformation (almost 90%) performed by hot rolling accompanied by an initial and final heat treatment. The new Ti-10Zr-5Ta-5Nb alloy presented self-passivation, with a large passive potential range and low passive current densities, namely, a very good anticorrosive resistance in Ringer solution of acid, neutral and alkaline pH values. Cell viability was not affected by the alloy substrate presence and a very good compatibility was noticed.


Subject(s)
Prostheses and Implants , Titanium/chemistry , Alloys/pharmacology , Body Fluids/drug effects , Corrosion , Humans , Isotonic Solutions , Osteoblasts/drug effects , Ringer's Solution
SELECTION OF CITATIONS
SEARCH DETAIL
...