J Adv Pharm Technol Res ; 13(2): 123-127, 2022.
Article in English | MEDLINE | ID: mdl-35464658

ABSTRACT

The notable unbiased of this research work was to evaluate the well-being and effectiveness of metaxalone by administering the newly developed test and reference drug. A two-period, two-categorization, crossover bioavailability study in fed conditions. Eleven participants were dosed and completed the trial successfully. The drugs were administered by way of a schedule. Samples collected in both periods for pharmacokinetic evaluation. Plasma samples analyzed using a validated method. Pharmacokinetic parameters for investigational and reference products were calculated using the metaxalone drug concentration and safety of the participants monitored by measurement of vital sign. Relative estimation factors calculated for Cmax, Tmax, area under the curve (AUC) t, AUC inf, K el, half-life, and 90% confidence intervals applied for to check for whether reference and test products are equivalent. The experimental part of the study was completed with no major adversarial event. No losses or stern adverse events transpired throughout the course of the experiment. The assessment product is analogous to reference product in relation to degree and extent of absorption. The outcome of this study indicates the newly developed drug is equivalent to the innovator drug and medication was well tolerated by all participants.

2.
Pak J Biol Sci ; 17(3): 429-33, 2014 Feb 01.
Article in English | MEDLINE | ID: mdl-24897800

ABSTRACT

This study describes the development and validation of dissolution tests for sustained release Dextromethorphan hydrobromide tablets using an HPLC method. Chromatographic separation was achieved on a C18 column utilizing 0.5% triethylamine (pH 7.5) and acetonitrile in the ratio of 50:50. The detection wavelength was 280 nm. The method was validated and response was found to be linear in the drug concentration range of 10-80 microg mL(-1). The suitable conditions were clearly decided after testing sink conditions, dissolution medium and agitation intensity. The most excellent dissolution conditions tested, for the Dextromethorphan hydrobromide was applied to appraise the dissolution profiles. The method was validated and response was found to be linear in the drug concentration range of 10-80 microg mL(-1). The method was established to have sufficient intermediate precision as similar separation was achieved on another instrument handled by different operators. Mean Recovery was 101.82%. Intra precisions for three different concentrations were 1.23, 1.10 0.72 and 1.57, 1.69, 0.95 and inter run precisions were % RSD 0.83, 1.36 and 1.57%, respectively. The method was successfully applied for dissolution study of the developed Dextromethorphan hydrobromide tablets.


Subject(s)
Chromatography, High Pressure Liquid/methods , Dextromethorphan/chemistry , Delayed-Action Preparations/analysis , Delayed-Action Preparations/chemistry , Dextromethorphan/administration & dosage , Dextromethorphan/analysis , Linear Models , Reproducibility of Results , Sensitivity and Specificity , Solubility , Tablets/chemistry , Tablets/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...