1.
Front Digit Health ; 5: 1128553, 2023.
Article in English | MEDLINE | ID: mdl-37800090

ABSTRACT

Importance: Home monitoring of blood pressure (BP) in hypertensive patients can improve outcomes, but challenges to both patient compliance and the effective transmission of home BP readings to physicians can limit the extent to which physicians can use this information to improve care. The OMRON Hypertension Management Platform (OMRON HMP) pairs a home BP cuff with a digital product that tracks data, provides reminders to improve patient compliance, and provides a streamlined source of information to physicians. Objective: The primary objective of the quality improvement (QI) project was to test the hypothesis that use of the OMRON HMP could reduce the number and cost of hypertension related claims, relative to a retrospectively matched cohort of insured members. A secondary objective was to demonstrate improvement in control of BP among patients. Design: Eligible members were recruited to the QI project between December 1, 2018 and December 30, 2020 and data collected for six months following recruitment. All members received the OMRON HMP intervention. Setting: Enrollment and data collection were coordinated on-site at selected PCP partner providers in Western Pennsylvania. Eligible members were identified from insurance claims data as those receiving care for primary hypertension from participating primary care physicians and/or cardiologists. Participants: Eligible members were between the ages of 35 and 85, with a diagnosis of primary hypertension. The retrospective cohort was selected from electronic medical records of Highmark-insured patients with hypertension who received care at Allegheny Health Network (AHN), a subsidiary of Highmark Health. Members were matched on baseline BP and lipid measures, age, smoking status, diabetes status, race and sex. Intervention: Daily home BP readings were recorded by the OMRON HMP app. Patient data was reviewed by clinical staff on a weekly basis and treatment plans could be adjusted in response to this data. Results: OMRON HMP users showed a significant increase in the number and cost of hypertension-related claims, contrary to the hypothesis, but did display improvements in control of BP. Conclusions and Relevance: The use of a digital platform to facilitate at-home BP monitoring appeared to improve BP control but led to increased hypertension-related costs in the short-term.

2.
JMIR Form Res ; 6(4): e31629, 2022 Apr 05.
Article in English | MEDLINE | ID: mdl-35147501

ABSTRACT

BACKGROUND: The Onduo virtual care program for people with type 2 diabetes (T2D) includes a mobile app, remote lifestyle coaching, connected devices, and telemedicine consultations with endocrinologists for medication management and prescription of real-time continuous glucose monitoring (RT-CGM) devices. In a previously described 4-month prospective study of this program, adults with T2D and baseline glycated hemoglobin (HbA1c) ≥8.0% to ≤12.0% experienced a mean HbA1c decrease of 1.6% with no significant increase in hypoglycemia. OBJECTIVE: The objective of this analysis was to evaluate medication optimization and management in the 4-month prospective T2D study. METHODS: Study participants received at least 1 telemedicine consultation with an Onduo endocrinologist for diabetes medication management and used RT-CGM intermittently to guide therapy and dosing. Medication changes were analyzed. RESULTS: Of 55 participants, 48 (87%) had a medication change consisting of a dose change, addition, or discontinuation. Of these, 15 (31%) participants had a net increase in number of diabetes medication classes from baseline. Mean time to first medication change for these participants was 36 days. The percentage of participants taking a glucagon-like peptide-1 receptor agonist increased from 25% (12/48) to 56% (n=27), while the percentages of participants taking a sulfonylurea or dipeptidyl peptidase 4 inhibitor decreased from 56% (n=27) to 33% (n=16) and 17% (n=8) to 6% (n=3), respectively. Prescriptions of other antidiabetic medication classes including insulin did not change significantly. CONCLUSIONS: The Onduo virtual care program can play an important role in providing timely access to guideline-based diabetes management medications and technologies for people with T2D. TRIAL REGISTRATION: ClinicalTrials.gov NCT03865381; https://clinicaltrials.gov/ct2/show/NCT03865381.

3.
J Med Internet Res ; 22(8): e21778, 2020 08 28.
Article in English | MEDLINE | ID: mdl-32856597

ABSTRACT

BACKGROUND: The Onduo virtual diabetes clinic (VDC) for people with type 2 diabetes (T2D) combines a mobile app, remote personalized lifestyle coaching, connected devices, and live video consultations with board-certified endocrinologists for medication management and prescription of real-time continuous glucose monitoring (RT-CGM) devices for intermittent use. OBJECTIVE: This prospective single-arm study evaluated glycemic outcomes associated with participation in the Onduo VDC for 4 months. METHODS: Adults aged ≥18 years with T2D and a baseline glycated hemoglobin (HbA1c) of ≥8% to ≤12% were enrolled from 2 primary care centers from February 2019 to October 2019. Participants were asked to engage at ≥1 time per week with their care team and to participate in a telemedicine consultation with a clinic endocrinologist for diabetes medication review. Participants were asked to use a RT-CGM device and wear six 10-day sensors (total 60 days of sensor wear) intermittently over the course of 4 months. The primary outcome was change in HbA1c at 4 months from baseline. Other endpoints included change in weight and in RT-CGM glycemic metrics, including percent time <70, 70-180, 181-250, and >250 mg/dL. Changes in blood pressure and serum lipids at 4 months were also evaluated. RESULTS: Participants (n=55) were 57.3 (SD 11.6) years of age, body mass index 33.7 (SD 7.2), and 40% (22/55) female. HbA1c decreased significantly by 1.6% (SD 1%; P<.001). When stratified by baseline HbA1c of 8.0% to 9.0% (n=36) and >9.0% (n=19), HbA1c decreased by 1.2% (SD 0.6%; P<.001) and 2.4% (SD 1.3%; P<.001), respectively. Continuous glucose monitoring-measured (n=43) percent time in range (TIR) 70-180 mg/dL increased by 10.2% (SD 20.5%; P=.002), from 65.4% (SD 23.2%) to 75.5% (SD 22.7%), which was equivalent to a mean increase of 2.4 hours TIR per day. Percent time 181-250 mg/dL and >250 mg/dL decreased by 7.2% (SD 15.4; P=.005) and 3.0% (SD 9.4; P=.01), respectively. There was no change in percent time <70 mg/dL. Mean weight decreased by 9.0 lb (SD 10.4; P<.001). Significant improvements were also observed in systolic blood pressure, total cholesterol, low-density lipoprotein cholesterol, and triglycerides (P=.04 to P=<.001). CONCLUSIONS: Participants in the Onduo VDC experienced significant improvement in HbA1c, increased TIR, decreased time in hyperglycemia, and no increase in hypoglycemia at 4 months. Improvements in other metabolic health parameters including weight and blood pressure were also observed. In conclusion, the Onduo VDC has potential to support people with T2D and their clinicians between office visits by increasing access to specialty care and advanced diabetes technology including RT-CGM. TRIAL REGISTRATION: ClinicalTrials.gov NCT03865381; https://clinicaltrials.gov/ct2/show/NCT03865381.