Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
ACS Macro Lett ; 5(4): 430-434, 2016 Apr 19.
Article in English | MEDLINE | ID: mdl-35607237

ABSTRACT

We study the conformations of polymer chains in polymer-graphene oxide nanocomposites. We show that the chains have a reduced radius of gyration that is consistent with confinement at a solid interface in the melt, as is expected for well-dispersed, high aspect ratio nanoparticles that are much larger than the polymer coil size. We show that confinement of the polymer chains causes a corresponding reduction in interchain entanglements, and we calculate a contribution to the plateau modulus from the distorted polymer network via a simple scaling argument. Our results are a significant step forward in understanding how two-dimensional nanoparticles affect global material properties at low loadings.

2.
Chem Commun (Camb) ; 51(51): 10345-8, 2015 Jun 28.
Article in English | MEDLINE | ID: mdl-25977943

ABSTRACT

Soft biocompatible gels comprised of rolled up graphene oxide nanocapsules within the pores of silanized hydrogels may be used as electrochemical pseudocapacitors with physiological glucose or KOH as a reducing agent, affording a material suitable for devices requiring pulses with characteristic time less than a second.


Subject(s)
Electric Capacitance , Graphite/chemistry , Hydrogels/chemistry , Nanocapsules/chemistry , Oxides/chemistry , Animals , Male , Materials Testing , Nanocapsules/ultrastructure , Polyvinyl Alcohol/chemistry , Rats , Rats, Wistar
3.
J AOAC Int ; 79(3): 623-7, 1996.
Article in English | MEDLINE | ID: mdl-8634529

ABSTRACT

A liquid chromatographic method is described for analysis of benzocaine (BZ), a proposed fish anesthetic, in rainbow trout plasma. Mean recoveries of BZ from plasma samples fortified at 44-10 100 ng/mL were 96-100%. The method detection limit is 10 ng/mL, and the limit of quantitation is 37 ng/mL. Acetylation of BZ occurs in whole blood after storage at room temperature (i.e., 21 degrees C) for 10 min. However, no acetylation of BZ was detected in plasma samples held at room temperature for 4 h. Mean method precision for plasma samples with incurred BZ residue is similar to that for fortified samples in the same concentration range (relative standard deviations of 0.9 and 1.2%, respectively).


Subject(s)
Anesthetics, Local/blood , Benzocaine/blood , Oncorhynchus mykiss/blood , Animals
SELECTION OF CITATIONS
SEARCH DETAIL
...