Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Publication year range
1.
Int J Oral Maxillofac Surg ; 50(3): 323-326, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32753230

ABSTRACT

The concept of a flow-through flap refers to a free flap in which both the proximal and distal ends of the vascular pedicle are anastomosed to provide blood flow to the distal tissues. The purpose of this paper is to highlight the use of this technique, which may be useful in selected cases of head and neck reconstruction. In certain situations, like bilateral resection of the base of the tongue involving both lingual arteries, the application of a flow-through forearm free flap can provide an anatomical and functional restoration of the defect while revascularizing the anterior two-thirds of the tongue. We review this technique, which was used in a case of adenoid cystic carcinoma of the base of the tongue with excellent results.


Subject(s)
Carcinoma, Adenoid Cystic , Free Tissue Flaps , Plastic Surgery Procedures , Tongue Neoplasms , Carcinoma, Adenoid Cystic/surgery , Forearm/surgery , Humans , Tongue/surgery , Tongue Neoplasms/surgery
2.
Rev. esp. cir. oral maxilofac ; 42(2): 51-59, abr.-jun. 2020. tab
Article in Spanish | IBECS | ID: ibc-189941

ABSTRACT

La pandemia por la nueva infección respiratoria conocida como enfermedad coronavirus 2019 (COVID-19), causada por el virus SARS-CoV-2, ha desencadenado una perturbación sin precedentes en la actividad habitual de los servicios de cirugía oral y maxilofacial en España, retrasando la atención rutinaria de pacientes e intervenciones quirúrgicas programadas. Los cirujanos orales y maxilofaciales son uno de los colectivos sanitarios con mayor riesgo de infección nosocomial por el estrecho contacto que se produce con los pacientes asintomáticos y sintomáticos con infección por SARS-CoV-2 a través de la cavidad oral y orofaringe. El propósito del presente documento ha sido actualizar la evidencia disponible para el manejo y tratamiento seguro y efectivo en consulta, cirugías ambulatorias, programadas y urgentes y hospitalización, minimizando al mismo tiempo, tanto como sea posible, el riesgo de contagio para el cirujano oral y maxilofacial, personal sanitario y pacientes. Este documento pretende esclarecer los aspectos más significativos y crear un protocolo común de manejo de pacientes con COVID-19 en cirugía oral y maxilofacial durante la fase aguda de propagación y de control posterior de la pandemia en nuestro país


The pandemic due to the new respiratory infection known as coronavirus 2019 disease (COVID-19), caused by the SARS-CoV-2 virus, has triggered an unprecedented disruption in the normal activity of oral and maxillofacial surgery departments in Spain, delaying routine patient care and elective surgical interventions. Oral and maxillofacial surgeons are one of the healthcare groups with the highest risk of nosocomial infection because of the close contact that occurs with asymptomatic and symptomatic patients with SARS-CoV-2 infection through the oral cavity and oropharynx. The purpose of this document has been to update the available evidence for the safe and effective management and treatment in outpatient clinic, ambulatory, elective and emergency surgeries, and hospitalization, while minimizing as much as possible the risk of infection for the oral and maxillofacial surgeon, health workers and patients. This document aims to clarify the most significant aspects and create a common protocol for the management of patients with COVID-19 in oral and maxillofacial surgery during the acute stage of spread and subsequent control of the pandemic in our country


Subject(s)
Humans , Surgery, Oral/standards , Orthognathic Surgical Procedures/standards , Coronavirus Infections/prevention & control , Pneumonia, Viral/prevention & control , Betacoronavirus , Protective Devices , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Evidence-Based Medicine , Clinical Protocols
3.
Rev Sci Instrum ; 89(10): 10B105, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399752

ABSTRACT

In order to improve both the density and particularly the temporal resolution beyond previous dispersion interferometers (DIs), a heterodyne technique based on an acousto-optic (AO) cell has been added to the DI. A 40 MHz drive frequency for the AO cell allows density fluctuation measurements into the MHz range. A CO2 laser-based heterodyne DI (HDI) installed on DIII-D has demonstrated that the HDI is capable of tracking the density evolution throughout DIII-D discharges, including disruption events and other rapid transient phenomena. The data also show good agreement with independent density measurements obtained with the existing DIII-D two-color interferometer. The HDI line-integrated density resolution sampled over a 1 s interval is ∼9 × 1017 m-2. Density fluctuations induced by MHD instabilities are also successfully measured by the HDI.

4.
Rev Sci Instrum ; 89(10): 10B102, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399936

ABSTRACT

A full-scale ITER toroidal interferometer and polarimeter (TIP) prototype, including an active feedback alignment system, has been installed and tested on the DIII-D tokamak. In the TIP prototype, a two-color interferometry measurement of line-integrated density is carried out at 10.59 µm and 5.22 µm using a CO2 and quantum cascade laser, respectively, while a separate polarimetry measurement of the plasma-induced Faraday effect is made at 10.59 µm. The TIP prototype is equipped with a piezo tip/tilt stage active feedback alignment system that minimizes noise in the measurement and keeps the diagnostic aligned throughout DIII-D discharges. The measured phase resolution for the polarimeter and interferometer is 0.05° (100 Hz bandwidth) and 1.9° (1 kHz bandwidth), respectively. The corresponding line-integrated density resolution for the vibration-compensated interferometer is δnL = 1.5 × 1018 m-2, and the magnetic field-weighted line-integrated density from the polarimeter is δnBL = 1.5 × 1019 Tm-2. Both interferometer and polarimeter measurements during DIII-D discharges compare well with the expectations based on calculations using Thomson scattering measured density profiles and magnetic equilibrium reconstructions. Additionally, larger bandwidth interferometer measurements show that the diagnostic is a sensitive monitor of core density fluctuations with demonstrated measurements of Alfvén eigenmodes and tearing modes.

5.
Rev Sci Instrum ; 87(12): 123502, 2016 Dec.
Article in English | MEDLINE | ID: mdl-28040946

ABSTRACT

A heterodyne detection scheme is combined with a 10.59 µm CO2 laser dispersion interferometer for the first time to allow large bandwidth measurements in the 10-100 MHz range. The approach employed utilizes a 40 MHz acousto-optic cell operating on the frequency doubled CO2 beam which is obtained using a high 2nd harmonic conversion efficiency orientation patterned gallium arsenide crystal. The measured standard deviation of the line integrated electron density equivalent phase resolution obtained with digital phase demodulation technique, is 4 × 1017 m-2. Air flow was found to significantly affect the baseline of the phase signal, which an optical table cover was able to reduce considerably. The heterodyne dispersion interferometer (DI) approach is found to be robustly insensitive to motion, with measured phase shifts below baseline drifts even in the presence of several centimeters of retroreflector induced path length variations. Plasma induced dispersion was simulated with a wedged ZnSe plate and the measured DI phase shifts are consistent with expectations.

SELECTION OF CITATIONS
SEARCH DETAIL
...