Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
Add more filters










Publication year range
1.
Phys Med Biol ; 68(19)2023 09 25.
Article in English | MEDLINE | ID: mdl-37747087

ABSTRACT

One of today's main challenges in molecular radiation therapy is to assess an individual dosimetry that allows treatment to be tailored to the specific patient, in accordance with the current paradigm of 'personalized medicine'. The evaluation of the absorbed doses for tumor and organs at risk in molecular radiotherapy is typically based on MIRD schema acquiring few experimental points for the assessement of biokinetic parameters. WIDMApp, the wearable individual dose monitoring apparatus, is an innovative approach for internal dosimetry based on a wearable radiation detecting system for individual biokinetics sampling, a Monte Carlo simulation for particle interaction, and an unfolding algorithm for data analysis and integrated activity determination at organ level. A prototype of a WIDMApp detector element was used to record the photon emissions in a body phantom containing 3 spheres with liquid sources (18F,64Cu and99mTc) to simulate organs having different washout. Modelling the phantom geometry on the basis of a CT scan imaging, the Monte Carlo simulation computed the contribution of each emitting sphere to the signal detected in 3 positions on the phantoms surface. Combining the simulated results with the data acquired for 120 h, the unfolding algorithm deconvolved the detected signal and assessed the decay half-life (T1/2) and initial activity values (A(0)) that best reproduces the observed exponential decays. A 3%-18% level of agreement is found between the actualA(0) andT1/2values and those obtained by means of the minimization procedure based on the Monte Carlo simulation. That resulted in an estimation of the cumulated activity <15%. Moreover, WIDMApp data redundancy has been used to mitigate some experimental occurrences that happened during data taking. A first experimental test of the WIDMApp approach to internal radiation dosimetry is presented. Studies with patients are foreseen to validate the technique in a real environment.


Subject(s)
Neoplasms , Radiometry , Humans , Radiometry/methods , Tomography, X-Ray Computed/methods , Computer Simulation , Algorithms , Phantoms, Imaging , Monte Carlo Method
2.
Phys Med ; 108: 102545, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37021607

ABSTRACT

Radio-Guided Surgery (RGS) is a nuclear medicine technique to support the surgeon during surgery towards a complete tumor resection. It is based on intraoperative detection of radiation emitted by a radio-pharmaceutical that bounds selectively to tumoral cells. In the past years, an approach that exploits ß- emitting radiotracers has been pursued to overtake some limitations of the traditional RGS based on γ emission. A particle detector dedicated to this application, demonstrating very high efficiency to ß- particles and remarkable transparency to photons, has been thus developed. As a by-product, its characteristics suggested the possibility to utilize it with ß+ emitting sources, more commonly in use in nuclear medicine. In this paper, performances of such detector on 18F liquid sources are estimated by means of Monte Carlo simulations (MC) and laboratory measurements. The experimental setup with a 18F saline solution comprised a "positron signal" spot (a 7 × 10 mm cylinder representing the tumor residual), and a surrounding "far background" volume, that represented for the detector an almost isotropic source of annihilation photons. Experimental results show good agreement with MC predictions, thus confirming the expected performances of the detector with 18F, and the validity of the developed MC simulation as a tool to predict the gamma background determined by a diffuse source of annihilation photons.


Subject(s)
Neoplasms , Surgery, Computer-Assisted , Humans , Beta Particles , Computer Simulation , Monte Carlo Method , Photons , Positron-Emission Tomography/methods
3.
Appl Radiat Isot ; 165: 109347, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32938536

ABSTRACT

Radioguided surgery (RGS) is a medical practice which thanks to a radiopharmaceutical tracer and a probe allows the surgeon to identify tumor residuals up to a millimetric resolution in real-time. The employment of ß- emitters, instead of γ or ß+, reduces background from healthy tissues, administered activity to the patient, and medical exposure. In a previous work the possibility of using a CMOS Imager (Aptina MT9V011), initially designed for visible light imaging, to detect ß- from 90Y or 90Sr sources has been established. Because of its possible application as counting probe in RGS, the performances of MT9V011 in clinical-like conditions were studied.1 Through horizontal scans on a collimated 90Sr source of different sizes (1, 3, 5, 7 mm), we have determined relationships between scan fit parameters and the source dimension, namely A quadratic correlation and a linear dependency of, respectively, signal integrated over scan interval, and maximum signal against source diameter, are determined. Horizontal scan measurements on a source, interposing collimators of different size, aim to determine relationships or correlations between scan fit parameters and source dimension. A quadratic correlation and a linear dependency of, respectively, signal integrated over scan interval, and maximum signal against source diameter are determined. In order to get closer to clinical conditions, agar-agar phantoms containing 90Y with different dimensions and activities were prepared. A 90Y phantom is characterized by a central spot and a ring all around, for simulating both signal (tumor) and background (surrounding healthy tissue). The relationship found between scan maximum and 90Sr source diameter is then exploited to extract the concentration ratio between spot and external ring of the 90Y phantom. This observable, defined as the ratio between the tumor and the nearby healthy tissues uptake simulates the Tumor-to-Non-tumor Ratio (TNR). With the aim of evaluating the sensor's ability to discriminate signal from background relying on the significance parameter, a further 90Y phantom, featuring a well-known and clinical-like activity will mimic the signal only condition. This result is used to extrapolate to different source sizes, after having estimated the background for various TNR. The obtained significance values suggest that the MT9V011 sensor is capable of distinguishing a signal from an estimated background, depending on the interplay among TNR, acquisition time and tumor diameter.


Subject(s)
Beta Particles , Neoplasms/surgery , Radiopharmaceuticals/chemistry , Surgery, Computer-Assisted/methods , Feasibility Studies , Humans
4.
Phys Med ; 72: 96-102, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32247965

ABSTRACT

This paper provides a first insight of the potential of the ß- Radio Guided Surgery (ß--RGS) in a complex surgical environment like the abdomen, where multiple sources of background concur to the signal at the tumor site. This case is well reproduced by ex-vivo samples of 90Y-marked Gastro-Entero-Pancreatic Neuroendocrine Tumors (GEP NET) in the bowel. These specimens indeed include at least three wide independent sources of background associated to three anatomical districts (mesentery, intestine, mucose). The study is based on the analysis of 37 lesions found on 5 samples belonging to 5 different patients. We show that the use of electrons, a short range particle, instead of γ particles, allows to limit counts read on a lesion to the sum of the tumor signal plus the background generated by the sole hosting district.The background on adjacent districts in the same specimen/patient is found to differ up to a factor 4, showing how the specificity and sensitivity of the ß--RGS technique can be fully exploited only upon a correct measurement of the contributing background. This locality has been used to set a site-specific cut-off algorithm to discriminate tumor and healthy tissue with a specificity of 100% and a sensitivity, on this test data sample, close to 100%. Factors influencing the sensitivity are also discussed. One of the specimens set allowed us evaluate the volume of the lesions, thus concluding that the probe was able to detect lesions as small as 0.04 mL in that particular case.


Subject(s)
Beta Particles/therapeutic use , Neuroendocrine Tumors/surgery , Surgery, Computer-Assisted/methods , Algorithms , Humans
5.
Phys Med ; 67: 85-90, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31704391

ABSTRACT

PURPOSE: Radio Guided Surgery (RGS) is a technique that helps the surgeon to achieve an as complete as possible tumor resection, thanks to the intraoperative detection of particles emitted by a radio tracer that bounds to tumoral cells. In the last years, a novel approach to this technique has been proposed that, exploiting ß- emitting radio tracers, overtakes some limitations of established γ-RGS. In this context, a first prototype of an intraoperative ß particle detector, based on a high light yield and low density organic scintillator, has been developed and characterised on pure ß- emitters, like 90Y. The demonstrated very high efficiency to ß- particles, together with the remarkable transparency to photons, suggested the possibility to use this detector also with ß+ emitting sources, that have plenty of applications in nuclear medicine. In this paper, we present upgrades and optimisations performed to the detector to reveal such particles. METHODS: Laboratory measurement have been performed on liquid Ga68 source, and were used to validate and tune a Monte Carlo simulation. RESULTS: The upgraded detector has an ~80% efficiency to electrons above ~110keV, reaching a plateau value of ~95%. At the same time, the probe is substantially transparent to photons below ~200keV, reaching a plateau value of ~3%. CONCLUSIONS: The new prototype seems to have promising characteristics to perform RGS also with ß+ emitting isotopes.


Subject(s)
Beta Particles , Electrons , Nuclear Medicine , Scintillation Counting , Surgery, Computer-Assisted
6.
Phys Med ; 58: 114-120, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30824142

ABSTRACT

PURPOSE: Radio-guided surgery with ß- decays is a novel technique under investigation. One of the main advantages is its capability to detect small (⩽0.1 ml) samples after injecting the patient with low activity of radiopharmaceutical. This paper presents an experimental method to quantify this feature based on ex-vivo tests on specimens from meningioma patients. METHODS: Patients were enrolled on the basis of the standard uptake value (SUV) and the tumour-to-non-tumour activity ratio (TNR) resulted from 68Ga-DOTATOC PET exams. After injecting the patients with 93-167 MBq of 90Y-DOTATOC, 26 samples excised during surgery were analyzed with a ß- probe. The radioactivity expected on the neoplastic specimens was estimated according to the SUV found in the PET scan and the correlation with the measured counts was studied. The doses to surgeon and medical personnel were also evaluated. RESULTS: Even injecting as low as 1.4 MBq/kg of radiotracer, tumour residuals of 0.1 ml can be detected. A negligible dose to the medical personnel was confirmed. CONCLUSIONS: Radio-guided surgery with ß- decays is a feasible technique with a low radiation dose for both personnel and patient, in particular if the patient is injected with the minimum required activity. A correlation greater than 80% was observed between the measured counts and the expected activity for the lesion samples based on the individual SUV and the TNR. This makes identifiable the minimum injectable radiotracer activity for cases where 90Y is the utilized radionuclide.


Subject(s)
Beta Particles , Positron-Emission Tomography , Surgery, Computer-Assisted/methods , Yttrium Radioisotopes/administration & dosage , Humans , Injections , Meningioma/diagnostic imaging , Meningioma/surgery , Occupational Exposure/analysis , Octreotide/administration & dosage , Octreotide/analogs & derivatives , Radiation Dosage
7.
Phys Med Biol ; 63(5): 055018, 2018 03 07.
Article in English | MEDLINE | ID: mdl-29265011

ABSTRACT

Proton and carbon ion beams are used in the clinical practice for external radiotherapy treatments achieving, for selected indications, promising and superior clinical results with respect to x-ray based radiotherapy. Other ions, like [Formula: see text] have recently been considered as projectiles in particle therapy centres and might represent a good compromise between the linear energy transfer and the radiobiological effectiveness of [Formula: see text] ion and proton beams, allowing improved tumour control probability and minimising normal tissue complication probability. All the currently used p, [Formula: see text] and [Formula: see text] ion beams allow achieving sharp dose gradients on the boundary of the target volume, however the accurate dose delivery is sensitive to the patient positioning and to anatomical variations with respect to photon therapy. This requires beam range and/or dose release measurement during patient irradiation and therefore the development of dedicated monitoring techniques. All the proposed methods make use of the secondary radiation created by the beam interaction with the patient and, in particular, in the case of [Formula: see text] ion beams are also able to exploit the significant charged radiation component. Measurements performed to characterise the charged secondary radiation created by [Formula: see text] and [Formula: see text] particle therapy beams are reported. Charged secondary yields, energy spectra and emission profiles produced in a poly-methyl methacrylate (PMMA) target by [Formula: see text] and [Formula: see text] beams of different therapeutic energies were measured at 60° and 90° with respect to the primary beam direction. The secondary yield of protons produced along the primary beam path in a PMMA target was obtained. The energy spectra of charged secondaries were obtained from time-of-flight information, whereas the emission profiles were reconstructed exploiting tracking detector information. The obtained measurements are in agreement with results reported in the literature and suggests the feasibility of range monitoring based on charged secondary particle detection: the implications for particle therapy monitoring applications are also discussed.


Subject(s)
Heavy Ion Radiotherapy/adverse effects , Helium/adverse effects , Polymethyl Methacrylate/radiation effects , Radiation Monitoring/methods , Radiotherapy Planning, Computer-Assisted/methods , Dose-Response Relationship, Radiation , Humans , Scattering, Radiation
8.
Phys Med Biol ; 62(4): 1438-1455, 2017 02 21.
Article in English | MEDLINE | ID: mdl-28114112

ABSTRACT

Charged particle beams are used in particle therapy (PT) to treat oncological patients due to their selective dose deposition in tissues with respect to the photons and electrons used in conventional radiotherapy. Heavy (Z > 1) PT beams can additionally be exploited for their high biological effectiveness in killing cancer cells. Nowadays, protons and carbon ions are used in PT clinical routines. Recently, interest in the potential application of helium and oxygen beams has been growing. With respect to protons, such beams are characterized by their reduced multiple scattering inside the body, increased linear energy transfer, relative biological effectiveness and oxygen enhancement ratio. The precision of PT demands online dose monitoring techniques, crucial to improving the quality assurance of any treatment: possible patient mis-positioning and biological tissue changes with respect to the planning CT scan could negatively affect the outcome of the therapy. The beam range confined in the irradiated target can be monitored thanks to the neutral or charged secondary radiation emitted by the interactions of hadron beams with matter. Among these secondary products, prompt photons are produced by nuclear de-excitation processes, and at present, different dose monitoring and beam range verification techniques based on prompt-γ detection are being proposed. It is hence of importance to perform γ yield measurement in therapeutic-like conditions. In this paper we report on the yields of prompt photons produced by the interaction of helium, carbon and oxygen ion beams with a poly-methyl methacrylate (PMMA) beam stopping target. The measurements were performed at the Heidelberg Ion-Beam Therapy Center (HIT) with beams of different energies. An LYSO scintillator, placed at [Formula: see text] and [Formula: see text] with respect to the beam direction, was used as the photon detector. The obtained γ yields for the carbon ion beams are compared with results from the literature, while no other results from helium and oxygen beams have been published yet. A discussion on the expected resolution of a slit camera detector is presented, demonstrating the feasibility of a prompt-γ-based monitoring technique for PT treatments using helium, carbon and oxygen ion beams.


Subject(s)
Heavy Ion Radiotherapy/methods , Photons , Polymethyl Methacrylate/radiation effects , Scintillation Counting/methods , Carbon/chemistry , Carbon/therapeutic use , Heavy Ion Radiotherapy/adverse effects , Heavy Ion Radiotherapy/standards , Helium/chemistry , Helium/therapeutic use , Humans , Linear Energy Transfer , Proton Therapy , Relative Biological Effectiveness , Scintillation Counting/instrumentation
9.
Phys Med Biol ; 62(4): 1291-1309, 2017 02 21.
Article in English | MEDLINE | ID: mdl-28114124

ABSTRACT

Nowadays there is a growing interest in particle therapy treatments exploiting light ion beams against tumors due to their enhanced relative biological effectiveness and high space selectivity. In particular promising results are obtained by the use of 4He projectiles. Unlike the treatments performed using protons, the beam ions can undergo a fragmentation process when interacting with the atomic nuclei in the patient body. In this paper the results of measurements performed at the Heidelberg Ion-Beam Therapy center are reported. For the first time the absolute fluxes and the energy spectra of the fragments-protons, deuterons, and tritons-produced by 4He ion beams of 102, 125 and 145 MeV u-1 energies on a poly-methyl methacrylate target were evaluated at different angles. The obtained results are particularly relevant in view of the necessary optimization and review of the treatment planning software being developed for clinical use of 4He beams in clinical routine and the relative bench-marking of Monte Carlo algorithm predictions.


Subject(s)
Helium/therapeutic use , Phantoms, Imaging , Polymethyl Methacrylate/chemistry , Radiation Monitoring/methods , Software , Algorithms , Humans , Monte Carlo Method , Protons , Radiotherapy Planning, Computer-Assisted , Relative Biological Effectiveness
10.
Phys Med ; 32(9): 1139-44, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27601248

ABSTRACT

PURPOSE: A radio-guided surgery technique with ß(-)-emitting radio-tracers was suggested to overcome the effect of the large penetration of γ radiation. The feasibility studies in the case of brain tumors and abdominal neuro-endocrine tumors were based on simulations starting from PET images with several underlying assumptions. This paper reports, as proof-of-principle of this technique, an ex vivo test on a meningioma patient. This test allowed to validate the whole chain, from the evaluation of the SUV of the tumor, to the assumptions on the bio-distribution and the signal detection. METHODS: A patient affected by meningioma was administered 300MBq of (90)Y-DOTATOC. Several samples extracted from the meningioma and the nearby Dura Mater were analyzed with a ß(-) probe designed specifically for this radio-guided surgery technique. The observed signals were compared both with the evaluation from the histology and with the Monte Carlo simulation. RESULTS: we obtained a large signal on the bulk tumor (105cps) and a significant signal on residuals of ∼0.2ml (28cps). We also show that simulations predict correctly the observed yields and this allows us to estimate that the healthy tissues would return negligible signals (≈1cps). This test also demonstrated that the exposure of the medical staff is negligible and that among the biological wastes only urine has a significant activity. CONCLUSIONS: This proof-of-principle test on a patient assessed that the technique is feasible with negligible background to medical personnel and confirmed that the expectations obtained with Monte Carlo simulations starting from diagnostic PET images are correct.


Subject(s)
Brain Neoplasms/radiotherapy , Meningioma/radiotherapy , Positron-Emission Tomography , Radiosurgery/methods , Surgery, Computer-Assisted/methods , Aged , Algorithms , Beta Particles , Brain Neoplasms/diagnostic imaging , Computer Simulation , Feasibility Studies , Female , Humans , Meningioma/diagnostic imaging , Models, Theoretical , Monte Carlo Method , Occupational Exposure/prevention & control , Octreotide/analogs & derivatives , Octreotide/chemistry , Radiometry , Reproducibility of Results
11.
Sci Rep ; 4: 4401, 2014 Mar 20.
Article in English | MEDLINE | ID: mdl-24646766

ABSTRACT

The background induced by the high penetration power of the radiation is the main limiting factor of the current radio-guided surgery (RGS). To partially mitigate it, a RGS with ß(+)-emitting radio-tracers has been suggested in literature. Here we propose the use of ß(-)-emitting radio-tracers and ß(-) probes and discuss the advantage of this method with respect to the previously explored ones: the electron low penetration power allows for simple and versatile probes and could extend RGS to tumours for which background originating from nearby healthy tissue makes probes less effective. We developed a ß(-) probe prototype and studied its performances on phantoms. By means of a detailed simulation we have also extrapolated the results to estimate the performances in a realistic case of meningioma, pathology which is going to be our first in-vivo test case. A good sensitivity to residuals down to 0.1 ml can be reached within 1 s with an administered activity smaller than those for PET-scans thus making the radiation exposure to medical personnel negligible.


Subject(s)
Beta Particles , Electrons , Phantoms, Imaging , Surgery, Computer-Assisted/instrumentation , Humans , Meningeal Neoplasms/pathology , Meningeal Neoplasms/surgery , Meningioma/pathology , Meningioma/surgery , Sensitivity and Specificity , Surgery, Computer-Assisted/methods , Tumor Microenvironment , Yttrium Radioisotopes
12.
Phys Med Biol ; 59(7): 1857-72, 2014 Apr 07.
Article in English | MEDLINE | ID: mdl-24625560

ABSTRACT

The radiation used in hadrontherapy treatments interacts with the patient body producing secondary particles, either neutral or charged, that can be used for dose and Bragg peak monitoring and to provide a fast feedback on the treatment plans. Recent results obtained from the authors on simplified setups (mono-energetic primary beams interacting with homogeneous tissue-like target) have already indicated the correlation that exists between the flux of these secondaries coming from the target (e.g. protons and photons) and the position of the primary beam Bragg peak. In this paper, the measurements of charged particle fluxes produced by the interaction of a 220 MeV/u carbon ion beam at GSI, Darmstadt, with a polymethyl methacrylate target are reported. The emission region of protons (p), deuterons (d) and tritons (t) has been characterized using a drift chamber while the particle time-of-flight, used to compute the kinetic energy spectra, was measured with a LYSO scintillator. The energy released in the LYSO crystal was used for particle identification purposes. The measurements were repeated with the setup at 60° and 90° with respect to the primary beam direction. The accuracy on the fragments emission profile reconstruction and its relationship with the Bragg peak position have been studied. Based on the acquired experimental evidence, a method to monitor the dose profile and the position of the Bragg peak inside the target is proposed.


Subject(s)
Carbon/therapeutic use , Polymethyl Methacrylate , Radiometry/methods , Monte Carlo Method
13.
Phys Med Biol ; 57(18): 5667-78, 2012 Sep 21.
Article in English | MEDLINE | ID: mdl-22935644

ABSTRACT

Hadrontherapy is an emerging technique in cancer therapy that uses beams of charged particles. To meet the improved capability of hadrontherapy in matching the dose release with the cancer position, new dose-monitoring techniques need to be developed and introduced into clinical use. The measurement of the fluxes of the secondary particles produced by the hadron beam is of fundamental importance in the design of any dose-monitoring device and is eagerly needed to tune Monte Carlo simulations. We report the measurements carried out with charged secondary particles produced from the interaction of a 80 MeV/u fully stripped carbon ion beam at the INFN Laboratori Nazionali del Sud, Catania, with a poly-methyl methacrylate target. Charged secondary particles, produced at 90° with respect to the beam axis, have been tracked with a drift chamber, while their energy and time of flight have been measured by means of a LYSO scintillator. Secondary protons have been identified exploiting the energy and time-of-flight information, and their emission region has been reconstructed backtracking from the drift chamber to the target. Moreover, a position scan of the target indicates that the reconstructed emission region follows the movement of the expected Bragg peak position. Exploiting the reconstruction of the emission region, an accuracy on the Bragg peak determination in the submillimeter range has been obtained. The measured differential production rate for protons produced with E(Prod)(kin) > 83 MeV and emitted at 90° with respect to the beam line is dN(P)/(dN(C)dΩ) (E(Prod)(kin) > 83 MeV, θ = 90°) = (2.69 ± 0.08(stat) ± 0.12(sys)) × 10⁻4 sr⁻¹.


Subject(s)
Heavy Ion Radiotherapy , Polymethyl Methacrylate , Radiometry/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...