Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
1.
Phys Rev Lett ; 131(24): 241802, 2023 Dec 15.
Article in English | MEDLINE | ID: mdl-38181129

ABSTRACT

We demonstrate the feasibility of probing the charged lepton-flavor-violating decay µ^{+}→e^{+}X^{0} for the presence of a slow-moving neutral boson X^{0} capable of undergoing gravitational binding to large structures and, as such, able to participate in some cosmological scenarios. A short exposure to surface antimuons from beam line M20 at TRIUMF generates a branching ratio limit of ≲10^{-5}. This is comparable to or better than previous searches for this channel, although in a thus-far-unexplored region of X^{0} phase space very close to the kinematic limit of the decay, where m_{X^{0}} approaches m_{µ^{+}}. The future improved sensitivity of the method using a customized p-type point-contact germanium detector is described.

2.
Phys Rev Lett ; 129(21): 211802, 2022 Nov 18.
Article in English | MEDLINE | ID: mdl-36461969

ABSTRACT

The 96.4 day exposure of a 3 kg ultralow noise germanium detector to the high flux of antineutrinos from a power nuclear reactor is described. A very strong preference (p<1.2×10^{-3}) for the presence of a coherent elastic neutrino-nucleus scattering (CEνNS) component in the data is found, when compared to a background-only model. No such effect is visible in 25 days of operation during reactor outages. The best-fit CEνNS signal is in good agreement with expectations based on a recent characterization of germanium response to sub-keV nuclear recoils. Deviations of order 60% from the standard model CEνNS prediction can be excluded using present data. Standing uncertainties in models of germanium quenching factor, neutrino energy spectrum, and background are examined.

3.
Phys Rev Lett ; 120(13): 132502, 2018 Mar 30.
Article in English | MEDLINE | ID: mdl-29694188

ABSTRACT

The Majorana Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-ß decay in ^{76}Ge. The Majorana Demonstrator comprises 44.1 kg of Ge detectors (29.7 kg enriched in ^{76}Ge) split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Here we present results from data taken during construction, commissioning, and the start of full operations. We achieve unprecedented energy resolution of 2.5 keV FWHM at Q_{ßß} and a very low background with no observed candidate events in 9.95 kg yr of enriched Ge exposure, resulting in a lower limit on the half-life of 1.9×10^{25} yr (90% C.L.). This result constrains the effective Majorana neutrino mass to below 240-520 meV, depending on the matrix elements used. In our experimental configuration with the lowest background, the background is 4.0_{-2.5}^{+3.1} counts/(FWHM t yr).

4.
Science ; 357(6356): 1123-1126, 2017 09 15.
Article in English | MEDLINE | ID: mdl-28775215

ABSTRACT

The coherent elastic scattering of neutrinos off nuclei has eluded detection for four decades, even though its predicted cross section is by far the largest of all low-energy neutrino couplings. This mode of interaction offers new opportunities to study neutrino properties and leads to a miniaturization of detector size, with potential technological applications. We observed this process at a 6.7σ confidence level, using a low-background, 14.6-kilogram CsI[Na] scintillator exposed to the neutrino emissions from the Spallation Neutron Source at Oak Ridge National Laboratory. Characteristic signatures in energy and time, predicted by the standard model for this process, were observed in high signal-to-background conditions. Improved constraints on nonstandard neutrino interactions with quarks are derived from this initial data set.

5.
Phys Rev Lett ; 118(25): 251301, 2017 Jun 23.
Article in English | MEDLINE | ID: mdl-28696731

ABSTRACT

New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C_{3}F_{8} located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C_{3}F_{8} exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than one event per month. A blind analysis of an efficiency-corrected 1167-kg day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. These results set the most stringent direct-detection constraint to date on the weakly interacting massive particle (WIMP)-proton spin-dependent cross section at 3.4×10^{-41} cm^{2} for a 30-GeV c^{-2} WIMP, more than 1 order of magnitude improvement from previous PICO results.

6.
Phys Rev Lett ; 114(23): 231302, 2015 Jun 12.
Article in English | MEDLINE | ID: mdl-26196790

ABSTRACT

New data are reported from the operation of a 2 liter C3F8 bubble chamber in the SNOLAB underground laboratory, with a total exposure of 211.5 kg days at four different energy thresholds below 10 keV. These data show that C3F8 provides excellent electron-recoil and alpha rejection capabilities at very low thresholds. The chamber exhibits an electron-recoil sensitivity of <3.5×10(-10) and an alpha rejection factor of >98.2%. These data also include the first observation of a dependence of acoustic signal on alpha energy. Twelve single nuclear recoil event candidates were observed during the run. The candidate events exhibit timing characteristics that are not consistent with the hypothesis of a uniform time distribution, and no evidence for a dark matter signal is claimed. These data provide the most sensitive direct detection constraints on WIMP-proton spin-dependent scattering to date, with significant sensitivity at low WIMP masses for spin-independent WIMP-nucleon scattering.


Subject(s)
Fluorocarbons/chemistry , Models, Theoretical , Acoustics/instrumentation , Algorithms , Neutrons
7.
Phys Rev Lett ; 113(22): 229001, 2014 Nov 28.
Article in English | MEDLINE | ID: mdl-25494093

ABSTRACT

A Comment on the Letter by J. H. Davis, Phys. Rev. Lett. 113, 081302 (2014)PRLTAO0031-900710.1103/PhysRevLett.113.081302.

8.
Phys Rev Lett ; 112(9): 091302, 2014 Mar 07.
Article in English | MEDLINE | ID: mdl-24655238

ABSTRACT

The CERN Axion Solar Telescope has finished its search for solar axions with (3)He buffer gas, covering the search range 0.64 eV ≲ ma ≲ 1.17 eV. This closes the gap to the cosmological hot dark matter limit and actually overlaps with it. From the absence of excess x rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of gaγ ≲ 3.3 × 10(-10) GeV(-1) at 95% C.L., with the exact value depending on the pressure setting. Future direct solar axion searches will focus on increasing the sensitivity to smaller values of gaγ, for example by the currently discussed next generation helioscope International AXion Observatory.

9.
Phys Rev Lett ; 110(21): 211101, 2013 May 24.
Article in English | MEDLINE | ID: mdl-23745854

ABSTRACT

The low-energy monochromatic neutron emission from an (88)Y/Be source can be exploited to mimic the few keV(nr) nuclear recoils expected from low-mass weakly interacting massive particles and coherent scattering of neutrinos off nuclei. Using this source, a

10.
Phys Rev Lett ; 107(14): 141301, 2011 Sep 30.
Article in English | MEDLINE | ID: mdl-22107183

ABSTRACT

Fifteen months of cumulative CoGeNT data are examined for indications of an annual modulation, a predicted signature of weakly interacting massive particle (WIMP) interactions. Presently available data support the presence of a modulated component of unknown origin, with parameters prima facie compatible with a galactic halo composed of light-mass WIMPs. Unoptimized estimators yield a statistical significance for a modulation of ∼2.8σ, limited by the short exposure.

11.
Phys Rev Lett ; 106(13): 131301, 2011 Apr 01.
Article in English | MEDLINE | ID: mdl-21517370

ABSTRACT

We report on several features in the energy spectrum from an ultralow-noise germanium detector operated deep underground. By implementing a new technique able to reject surface events, a number of cosmogenic peaks can be observed for the first time. We discuss an irreducible excess of bulklike events below 3 keV in ionization energy. These could be caused by unknown backgrounds, but also dark matter interactions consistent with DAMA/LIBRA. It is not yet possible to determine their origin. Improved constraints are placed on a cosmological origin for the DAMA/LIBRA effect.

12.
Phys Rev Lett ; 106(2): 021303, 2011 Jan 14.
Article in English | MEDLINE | ID: mdl-21405218

ABSTRACT

Data from the operation of a bubble chamber filled with 3.5 kg of CF3I in a shallow underground site are reported. An analysis of ultrasound signals accompanying bubble nucleations confirms that alpha decays generate a significantly louder acoustic emission than single nuclear recoils, leading to an efficient background discrimination. Three dark matter candidate events were observed during an effective exposure of 28.1 kg day, consistent with a neutron background. This observation provides strong direct detection constraints on weakly interacting massive particle (WIMP)-proton spin-dependent scattering for WIMP masses >20 GeV/c2.

13.
Phys Rev Lett ; 107(26): 261302, 2011 Dec 23.
Article in English | MEDLINE | ID: mdl-22243149

ABSTRACT

The CERN Axion Solar Telescope (CAST) has extended its search for solar axions by using (3)He as a buffer gas. At T=1.8 K this allows for larger pressure settings and hence sensitivity to higher axion masses than our previous measurements with (4)He. With about 1 h of data taking at each of 252 different pressure settings we have scanned the axion mass range 0.39 eV≲m(a)≲0.64 eV. From the absence of excess x rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g(aγ)≲2.3×10(-10) GeV(-1) at 95% C.L., the exact value depending on the pressure setting. Kim-Shifman-Vainshtein-Zakharov axions are excluded at the upper end of our mass range, the first time ever for any solar axion search. In the future we will extend our search to m(a)≲1.15 eV, comfortably overlapping with cosmological hot dark matter bounds.

14.
Phys Rev Lett ; 101(25): 251301, 2008 Dec 19.
Article in English | MEDLINE | ID: mdl-19113689

ABSTRACT

A claim for evidence of dark matter interactions in the DAMA experiment has been recently reinforced. We employ a new type of germanium detector to conclusively rule out a standard isothermal galactic halo of weakly interacting massive particles as the explanation for the annual modulation effect leading to the claim. Bounds are similarly imposed on a suggestion that dark pseudoscalars might lead to the effect. We describe the sensitivity to light dark matter particles achievable with our device, in particular, to next-to-minimal supersymmetric model candidates.

15.
Science ; 319(5865): 933-6, 2008 Feb 15.
Article in English | MEDLINE | ID: mdl-18276885

ABSTRACT

Bubble chambers were the dominant technology used for particle detection in accelerator experiments for several decades, eventually falling into disuse with the advent of other techniques. We report here on a new application for these devices. We operated an ultraclean, room-temperature bubble chamber containing 1.5 kilograms of superheated CF3I, a target maximally sensitive to spin-dependent and -independent weakly interacting massive particle (WIMP) couplings. An extreme intrinsic insensitivity to the backgrounds that commonly limit direct searches for dark matter was measured in this device under operating conditions leading to the detection of low-energy nuclear recoils like those expected from WIMPs. Improved limits on the spin-dependent WIMP-proton scattering cross section were extracted during our experiments, excluding this type of coupling as a possible explanation for a recent claim of particle dark-matter detection.

16.
Phys Rev Lett ; 99(15): 151301, 2007 Oct 12.
Article in English | MEDLINE | ID: mdl-17995155

ABSTRACT

We study the prospects for detecting weakly interacting massive particles (WIMPs) in a number of phenomenological scenarios, with a detector composed of a target simultaneously sensitive to both spin-dependent and spin-independent couplings, as is the case of COUPP (Chicagoland Observatory for Underground Particle Physics). First, we show that sensitivity to both couplings optimizes chances of initial WIMP detection. Second, we demonstrate that, in case of detection, a comparison of the signal on two complementary targets, such as in COUPP CF3I and C4F10 bubble chambers, allows a significantly more precise determination of the dark matter axial and scalar couplings. This strategy would provide crucial information on the nature of the WIMPs and possibly allow discrimination between neutralino and Kaluza-Klein dark matter.

17.
Radiat Prot Dosimetry ; 120(1-4): 503-8, 2006.
Article in English | MEDLINE | ID: mdl-16644935

ABSTRACT

We describe the fabrication and characterisation of the SIMPLE superheated droplet detector, a 10 g active mass device of C(2)ClF(5) in 1-3% weight concentrations currently employed in a direct search for spin-dependent astroparticle dark matter candidates.


Subject(s)
Chlorofluorocarbons, Methane/chemistry , Chlorofluorocarbons, Methane/radiation effects , Cosmic Radiation , Extraterrestrial Environment , Thermoluminescent Dosimetry/instrumentation , Dose-Response Relationship, Radiation , Equipment Design , Equipment Failure Analysis , Hot Temperature , Microbubbles , Radiation Dosage , Thermoluminescent Dosimetry/methods
18.
Appl Radiat Isot ; 63(5-6): 645-53, 2005.
Article in English | MEDLINE | ID: mdl-16005238

ABSTRACT

Research investigating the application of pressure-cycled bubble chambers to fast neutron detection is described. Experiments with a Halon-filled chamber showed clear sensitivity to an AmBe neutron source and insensitivity to a (137)Cs gamma source. Bubble formation was documented using high-speed photography, and a ceramic piezo-electric transducer element registered the acoustic signature of bubble formation. In a second set of experiments, the bubble nucleation response of a Freon-134a chamber to an AmBe neutron source was documented with high-speed photography.

19.
Phys Rev Lett ; 94(12): 121301, 2005 Apr 01.
Article in English | MEDLINE | ID: mdl-15903903

ABSTRACT

Hypothetical axionlike particles with a two-photon interaction would be produced in the sun by the Primakoff process. In a laboratory magnetic field ("axion helioscope"), they would be transformed into x-rays with energies of a few keV. Using a decommissioned Large Hadron Collider test magnet, the CERN Axion Solar Telescope ran for about 6 months during 2003. The first results from the analysis of these data are presented here. No signal above background was observed, implying an upper limit to the axion-photon coupling g(agamma)<1.16x10(-10) GeV-1 at 95% C.L. for m(a) less, similar 0.02 eV. This limit, assumption-free, is comparable to the limit from stellar energy-loss arguments and considerably more restrictive than any previous experiment over a broad range of axion masses.

20.
Phys Rev Lett ; 85(15): 3083-6, 2000 Oct 09.
Article in English | MEDLINE | ID: mdl-11019272

ABSTRACT

We report on the fabrication aspects and calibration of the first large active mass ( approximately 15 g) modules of SIMPLE, a search for particle dark matter using superheated droplet detectors (SDDs). While still limited by the statistical uncertainty of the small data sample on hand, the first weeks of operation in the new underground laboratory of Rustrel-Pays d'Apt already provide a sensitivity to axially coupled weakly interacting massive particles (WIMPs) competitive with leading experiments, confirming SDDs as a convenient, low-cost alternative for WIMP detection.

SELECTION OF CITATIONS
SEARCH DETAIL
...