Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 59
Filter
Add more filters










Publication year range
1.
Article in English | MEDLINE | ID: mdl-38536680

ABSTRACT

Exoskeletons are a burgeoning technology with many possible applications to improve human life; focusing the effort of exoskeleton research and development on the most important features is essential for facilitating adoption and maximizing positive societal impact. To identify important focus areas for exoskeleton research and development, we conducted a survey with 154 potential users (older adults) and another survey with 152 clinicians. The surveys were conducted online and to ensure a consistent concept of an exoskeleton across respondents, an image of a hip exoskeleton was shown during exoskeleton-related prompts. The survey responses indicate that both older adults and clinicians are open to using exoskeletons, fall prevention and joint pain reduction are especially important features, and users are likely to wear an exoskeleton in the scenarios when it has the greatest opportunity to help prevent a fall. These findings can help inform future exoskeleton research and guide the development of devices that are accepted, used, and provide meaningful benefit to users.


Subject(s)
Exoskeleton Device , Humans , Aged , Walking/physiology , Accidental Falls/prevention & control , Lower Extremity/physiology
2.
Sci Robot ; 9(88): eadj7246, 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38507474

ABSTRACT

Electric motors are widely used in robots but waste energy in many applications. We introduce an elastic energy-recycling actuator that maintains the versatility of motors while improving energy efficiency in cyclic tasks. The actuator comprises a motor in parallel with an array of springs that can be individually engaged and disengaged, while retaining stored energy, by pairs of low-power electroadhesive clutches. We developed a prototype actuator and tested it in five repetitive tasks with features common in robotic applications but difficult to perform efficiently. The actuator reduced power consumption by at least 50% in all cases and by 97% in the best case. Elastic energy recovery, controlled by low-power clutches, can improve the efficiency of mobile robots, assistive devices, and other engineered systems.

3.
Front Robot AI ; 11: 1283080, 2024.
Article in English | MEDLINE | ID: mdl-38357293

ABSTRACT

Exoskeletons that assist in ankle plantarflexion can improve energy economy in locomotion. Characterizing the joint-level mechanisms behind these reductions in energy cost can lead to a better understanding of how people interact with these devices, as well as to improved device design and training protocols. We examined the biomechanical responses to exoskeleton assistance in exoskeleton users trained with a lengthened protocol. Kinematics at unassisted joints were generally unchanged by assistance, which has been observed in other ankle exoskeleton studies. Peak plantarflexion angle increased with plantarflexion assistance, which led to increased total and biological mechanical power despite decreases in biological joint torque and whole-body net metabolic energy cost. Ankle plantarflexor activity also decreased with assistance. Muscles that act about unassisted joints also increased activity for large levels of assistance, and this response should be investigated over long-term use to prevent overuse injuries.

4.
J Neuroeng Rehabil ; 21(1): 1, 2024 01 02.
Article in English | MEDLINE | ID: mdl-38167151

ABSTRACT

BACKGROUND: Walking speed and energy economy tend to decline with age. Lower-limb exoskeletons have demonstrated potential to improve either measure, but primarily in studies conducted on healthy younger adults. Promising techniques like optimization of exoskeleton assistance have yet to be tested with older populations, while speed and energy consumption have yet to be simultaneously optimized for any population. METHODS: We investigated the effectiveness of human-in-the-loop optimization of ankle exoskeletons with older adults. Ten healthy adults > 65 years of age (5 females; mean age: 72 ± 3 yrs) participated in approximately 240 min of training and optimization with tethered ankle exoskeletons on a self-paced treadmill. Multi-objective human-in-the-loop optimization was used to identify assistive ankle plantarflexion torque patterns that simultaneously improved self-selected walking speed and metabolic rate. The effects of optimized exoskeleton assistance were evaluated in separate trials. RESULTS: Optimized exoskeleton assistance improved walking performance for older adults. Both objectives were simultaneously improved; self-selected walking speed increased by 8% (0.10 m/s; p = 0.001) and metabolic rate decreased by 19% (p = 0.007), resulting in a 25% decrease in energetic cost of transport (p = 8e-4) compared to walking with exoskeletons applying zero torque. Compared to younger participants in studies optimizing a single objective, our participants required lower exoskeleton torques, experienced smaller improvements in energy use, and required more time for motor adaptation. CONCLUSIONS: Our results confirm that exoskeleton assistance can improve walking performance for older adults and show that multiple objectives can be simultaneously addressed through human-in-the-loop optimization.


Subject(s)
Exoskeleton Device , Female , Humans , Aged , Walking Speed , Electromyography/methods , Biomechanical Phenomena , Ankle , Ankle Joint , Walking , Gait
5.
PLoS One ; 18(11): e0295152, 2023.
Article in English | MEDLINE | ID: mdl-38033114

ABSTRACT

Creating large-scale public datasets of human motion biomechanics could unlock data-driven breakthroughs in our understanding of human motion, neuromuscular diseases, and assistive devices. However, the manual effort currently required to process motion capture data and quantify the kinematics and dynamics of movement is costly and limits the collection and sharing of large-scale biomechanical datasets. We present a method, called AddBiomechanics, to automate and standardize the quantification of human movement dynamics from motion capture data. We use linear methods followed by a non-convex bilevel optimization to scale the body segments of a musculoskeletal model, register the locations of optical markers placed on an experimental subject to the markers on a musculoskeletal model, and compute body segment kinematics given trajectories of experimental markers during a motion. We then apply a linear method followed by another non-convex optimization to find body segment masses and fine tune kinematics to minimize residual forces given corresponding trajectories of ground reaction forces. The optimization approach requires approximately 3-5 minutes to determine a subject's skeleton dimensions and motion kinematics, and less than 30 minutes of computation to also determine dynamically consistent skeleton inertia properties and fine-tuned kinematics and kinetics, compared with about one day of manual work for a human expert. We used AddBiomechanics to automatically reconstruct joint angle and torque trajectories from previously published multi-activity datasets, achieving close correspondence to expert-calculated values, marker root-mean-square errors less than 2 cm, and residual force magnitudes smaller than 2% of peak external force. Finally, we confirmed that AddBiomechanics accurately reproduced joint kinematics and kinetics from synthetic walking data with low marker error and residual loads. We have published the algorithm as an open source cloud service at AddBiomechanics.org, which is available at no cost and asks that users agree to share processed and de-identified data with the community. As of this writing, hundreds of researchers have used the prototype tool to process and share about ten thousand motion files from about one thousand experimental subjects. Reducing the barriers to processing and sharing high-quality human motion biomechanics data will enable more people to use state-of-the-art biomechanical analysis, do so at lower cost, and share larger and more accurate datasets.


Subject(s)
Models, Biological , Musculoskeletal System , Humans , Biomechanical Phenomena , Walking , Motion
6.
PLoS Comput Biol ; 19(8): e1010712, 2023 08.
Article in English | MEDLINE | ID: mdl-37549183

ABSTRACT

Walking balance is central to independent mobility, and falls due to loss of balance are a leading cause of death for people 65 years of age and older. Bipedal gait is typically unstable, but healthy humans use corrective torques to counteract perturbations and stabilize gait. Exoskeleton assistance could benefit people with neuromuscular deficits by providing stabilizing torques at lower-limb joints to replace lost muscle strength and sensorimotor control. However, it is unclear how applied exoskeleton torques translate to changes in walking kinematics. This study used musculoskeletal simulation to investigate how exoskeleton torques applied to the ankle and subtalar joints alter center of mass kinematics during walking. We first created muscle-driven walking simulations using OpenSim Moco by tracking experimental kinematics and ground reaction forces recorded from five healthy adults. We then used forward integration to simulate the effect of exoskeleton torques applied to the ankle and subtalar joints while keeping muscle excitations fixed based on our previous tracking simulation results. Exoskeleton torque lasted for 15% of the gait cycle and was applied between foot-flat and toe-off during the stance phase, and changes in center of mass kinematics were recorded when the torque application ended. We found that changes in center of mass kinematics were dependent on both the type and timing of exoskeleton torques. Plantarflexion torques produced upward and backward changes in velocity of the center of mass in mid-stance and upward and smaller forward velocity changes near toe-off. Eversion and inversion torques primarily produced lateral and medial changes in velocity in mid-stance, respectively. Intrinsic muscle properties reduced kinematic changes from exoskeleton torques. Our results provide mappings between ankle plantarflexion and inversion-eversion torques and changes in center of mass kinematics which can inform designers building exoskeletons aimed at stabilizing balance during walking. Our simulations and software are freely available and allow researchers to explore the effects of applied torques on balance and gait.


Subject(s)
Ankle , Exoskeleton Device , Adult , Humans , Torque , Biomechanical Phenomena/physiology , Walking/physiology , Gait/physiology
7.
bioRxiv ; 2023 Sep 08.
Article in English | MEDLINE | ID: mdl-37398034

ABSTRACT

Creating large-scale public datasets of human motion biomechanics could unlock data-driven breakthroughs in our understanding of human motion, neuromuscular diseases, and assistive devices. However, the manual effort currently required to process motion capture data and quantify the kinematics and dynamics of movement is costly and limits the collection and sharing of large-scale biomechanical datasets. We present a method, called AddBiomechanics, to automate and standardize the quantification of human movement dynamics from motion capture data. We use linear methods followed by a non-convex bilevel optimization to scale the body segments of a musculoskeletal model, register the locations of optical markers placed on an experimental subject to the markers on a musculoskeletal model, and compute body segment kinematics given trajectories of experimental markers during a motion. We then apply a linear method followed by another non-convex optimization to find body segment masses and fine tune kinematics to minimize residual forces given corresponding trajectories of ground reaction forces. The optimization approach requires approximately 3-5 minutes to determine a subjects skeleton dimensions and motion kinematics, and less than 30 minutes of computation to also determine dynamically consistent skeleton inertia properties and fine-tuned kinematics and kinetics, compared with about one day of manual work for a human expert. We used AddBiomechanics to automatically reconstruct joint angle and torque trajectories from previously published multi-activity datasets, achieving close correspondence to expert-calculated values, marker root-mean-square errors less than 2cm, and residual force magnitudes smaller than 2% of peak external force. Finally, we confirmed that AddBiomechanics accurately reproduced joint kinematics and kinetics from synthetic walking data with low marker error and residual loads. We have published the algorithm as an open source cloud service at AddBiomechanics.org, which is available at no cost and asks that users agree to share processed and de-identified data with the community. As of this writing, hundreds of researchers have used the prototype tool to process and share about ten thousand motion files from about one thousand experimental subjects. Reducing the barriers to processing and sharing high-quality human motion biomechanics data will enable more people to use state-of-the-art biomechanical analysis, do so at lower cost, and share larger and more accurate datasets.

8.
IEEE Trans Haptics ; 15(4): 741-752, 2022.
Article in English | MEDLINE | ID: mdl-36343009

ABSTRACT

Real-world application of haptic feedback from kinesthetic devices is implemented while the user is in motion, but human wrist torque magnitude discrimination has previously only been characterized while users are stationary. In this study, we measured wrist torque discrimination in conditions relevant to activities of daily living, using a previously developed backdrivable wrist exoskeleton capable of applying wrist flexion and extension torque. We implemented a torque comparison test using a two-alternative forced-choice paradigm while participants were both seated and walking on a treadmill, with both a stationary and a moving wrist. Like most kinesthetic haptic devices, the wrist exoskeleton output torque is commanded in an open-loop manner. Thus, the study design was informed by Monte Carlo simulations to verify that the errors in the wrist exoskeleton output torque would not significantly affect the results. Results from ten participants show that although both walking and moving wrist conditions result in higher Weber Fractions (worse perception), participants were able to detect relatively small changes in torque of 12-19% on average in all grouped conditions. The results provide insight regarding the torque magnitudes necessary to make wrist-worn kinesthetic haptic devices noticeable and meaningful to the user in various conditions relevant to activities of daily living.


Subject(s)
Touch Perception , Wrist , Humans , Activities of Daily Living , Torque , Movement , Lower Extremity , Biomechanical Phenomena
9.
Nature ; 610(7931): 277-282, 2022 10.
Article in English | MEDLINE | ID: mdl-36224415

ABSTRACT

Personalized exoskeleton assistance provides users with the largest improvements in walking speed1 and energy economy2-4 but requires lengthy tests under unnatural laboratory conditions. Here we show that exoskeleton optimization can be performed rapidly and under real-world conditions. We designed a portable ankle exoskeleton based on insights from tests with a versatile laboratory testbed. We developed a data-driven method for optimizing exoskeleton assistance outdoors using wearable sensors and found that it was equally effective as laboratory methods, but identified optimal parameters four times faster. We performed real-world optimization using data collected during many short bouts of walking at varying speeds. Assistance optimized during one hour of naturalistic walking in a public setting increased self-selected speed by 9 ± 4% and reduced the energy used to travel a given distance by 17 ± 5% compared with normal shoes. This assistance reduced metabolic energy consumption by 23 ± 8% when participants walked on a treadmill at a standard speed of 1.5 m s-1. Human movements encode information that can be used to personalize assistive devices and enhance performance.


Subject(s)
Exoskeleton Device , Walking , Ankle , Ankle Joint , Humans , Walking Speed
10.
J Prosthet Orthot ; 34(4): 202-212, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36157327

ABSTRACT

Introduction: The design and selection of lower-limb prosthetic devices is currently hampered by a shortage of evidence to drive the choice of prosthetic foot parameters. We propose a new approach wherein prostheses could be designed, specified, and provided based on individualized measurements of the benefits provided by candidate feet. In this manuscript, we present a pilot test of this evidence-based and personalized process. Methods: We previously developed a "prosthetic foot emulator," a wearable robotic system that provides users with the physical sensation of trying on different prosthetic feet before definitive fitting. Here we detail preliminary demonstrations of two possible approaches to personalizing foot design: 1) an emulation and test-drive strategy of representative commercial foot models, and 2) a prosthetist-driven tuning procedure to optimize foot parameters. Results: The first experiment demonstrated large and sometimes surprising differences in optimal prosthetic foot parameters across a variety of subjects, walking conditions, and outcome measures. The second experiment demonstrated a quick and effective simple manual tuning procedure for identifying preferred prosthetic foot parameters. Conclusions: Emulator-based approaches could improve individualization of prosthetic foot prescription. The present results motivate future clinical studies of the validity, efficacy, and economics of the approach across larger and more diverse subject populations. Clinical Relevance: Today, emulator technology is being used to accelerate research and development of novel prosthetic and orthotic devices. In the future, after further refinement and validation, this technology could benefit clinical practice by providing a means for rapid test-driving and optimal selection of clinically available prosthetic feet.

11.
Article in English | MEDLINE | ID: mdl-35930513

ABSTRACT

For exoskeletons to be successful in real-world settings, they will need to be effective across a variety of terrains, including on inclines. While some single-joint exoskeletons have assisted incline walking, recent successes in level-ground assistance suggest that greater improvements may be possible by optimizing assistance of the whole leg. To understand how exoskeleton assistance should change with incline, we used human-in-the-loop optimization to find whole-leg exoskeleton assistance torques that minimized metabolic cost on a range of grades. We optimized assistance for three non-disabled, expert participants on 5 degree, 10 degree, and 15 degree inclines using a hip-knee-ankle exoskeleton emulator. For all assisted conditions, the cost of transport was reduced by at least 50% relative to walking in the device with no assistance, which is a large improvement to walking comparable to the benefits of whole-leg assistance on level-ground (N = 3). Optimized extension torque magnitudes and exoskeleton power increased with incline. Hip extension, knee extension and ankle plantarflexion often grew as large as allowed by comfort-based limits. Applied powers on steep inclines were double the powers applied during level-ground walking, indicating that greater exoskeleton power may be optimal in scenarios where biological powers and costs are higher. Future exoskeleton devices could deliver large improvements in walking performance across a range of inclines if they have sufficient torque and power capabilities.


Subject(s)
Exoskeleton Device , Ankle , Ankle Joint , Biomechanical Phenomena , Humans , Lower Extremity , Walking
12.
Curr Biol ; 32(10): 2222-2232.e5, 2022 05 23.
Article in English | MEDLINE | ID: mdl-35537453

ABSTRACT

Our nervous systems can learn optimal control policies in response to changes to our bodies, tasks, and movement contexts. For example, humans can learn to adapt their control policy in walking contexts where the energy-optimal policy is shifted along variables such as step frequency or step width. However, it is unclear how the nervous system determines which ways to adapt its control policy. Here, we asked how human participants explore through variations in their control policy to identify more optimal policies in new contexts. We created new contexts using exoskeletons that apply assistive torques to each ankle at each walking step. We analyzed four variables that spanned the levels of the whole movement, the joint, and the muscle: step frequency, ankle angle range, total soleus activity, and total medial gastrocnemius activity. We found that, across all of these analyzed variables, variability increased upon initial exposure to new contexts and then decreased with experience. This led to adaptive changes in the magnitude of specific variables, and these changes were correlated with reduced energetic cost. The timescales by which adaptive changes progressed and variability decreased were faster for some variables than others, suggesting a reduced search space within which the nervous system continues to optimize its policy. These collective findings support the principle that exploration through general variability leads to specific adaptation toward optimal movement policies.


Subject(s)
Energy Metabolism , Walking , Adaptation, Physiological , Biomechanical Phenomena , Energy Metabolism/physiology , Gait/physiology , Humans , Muscle, Skeletal/physiology , Policy , Walking/physiology
13.
J Neuroeng Rehabil ; 19(1): 46, 2022 05 12.
Article in English | MEDLINE | ID: mdl-35549977

ABSTRACT

BACKGROUND: Reducing the energy cost of running with exoskeletons could improve enjoyment, reduce fatigue, and encourage participation among novice and ageing runners. Previously, tethered ankle exoskeleton emulators with offboard motors were used to greatly reduce the energy cost of running with powered ankle plantarflexion assistance. Through a process known as "human-in-the-loop optimization", the timing and magnitude of assistance torque was optimized to maximally reduce metabolic cost. However, to achieve the maximum net benefit in energy cost outside of the laboratory environment, it is also necessary to consider the tradeoff between the magnitude of device assistance and the metabolic penalty of carrying a heavier, more powerful exoskeleton. METHODS: In this study, tethered ankle exoskeleton emulators were used to characterize the effect of peak assistance torque on metabolic cost during running. Three recreational runners participated in human-in-the-loop optimization at four fixed peak assistance torque levels to obtain their energetically optimal assistance timing parameters at each level. RESULTS: We found that the relationship between metabolic rate and peak assistance torque was nearly linear but with diminishing returns at higher torque magnitudes, which is well-approximated by an asymptotic exponential function. At the highest assistance torque magnitude of 0.8 Nm/kg, participants' net metabolic rate was 24.8 ± 2.3% (p = 4e-6) lower than running in the unpowered devices. Optimized timing of peak assistance torque was as late as allowed during stance (80% of stance) and optimized timing of torque removal was at toe-off (100% of stance); similar assistance timing was preferred across participants and torque magnitudes. CONCLUSIONS: These results allow exoskeleton designers to predict the energy cost savings for candidate devices with different assistance torque capabilities, thus informing the design of portable ankle exoskeletons that maximize net metabolic benefit.


Subject(s)
Exoskeleton Device , Ankle , Ankle Joint , Biomechanical Phenomena , Energy Metabolism , Gait , Humans , Torque , Walking
14.
J Biomech ; 132: 110905, 2022 02.
Article in English | MEDLINE | ID: mdl-34998181

ABSTRACT

Walking on a split-belt treadmill is often compared to walking on tied belts at the average speed, but the relationship between the metabolic energy costs of split- and tied-belt walking remains largely unexplored. Recent simulation work has suggested that people could take advantage of a belt speed difference and lower their energy costs, but this effect has not yet been observed experimentally. To relate metabolic energy costs across a range of belt speed combinations, we had 10 participants each complete 14 tied-belt and 39 split-belt walking trials, with early split-belt trials incorporating additional time for training. The average speeds ranged from 0.6 to 1.8 m/s with belt speed differences up to 1.4 m/s. We used ANOVA to determine differences in energy cost due to average speed and belt speed difference. We fit a linear model to estimate the tied-belt speed with the same energy cost as a given pair of split belt speeds. The cost of split-belt walking was on average just 0.13 ± 0.32 W/kg more expensive than the cost of tied-belt walking at the average speed. Contrary to predictions from simple dynamical models, increased belt speed difference resulted in increased energy cost, and the energetically equivalent tied-belt speed could be estimated as veq=vavg+0.065⋅Δv. Clinicians designing rehabilitation protocols can balance the therapeutic benefits of higher belt speed difference with increased energetic demands. Open questions remain about why people cannot fully take advantage of mechanical work performed by a split-belt treadmill.


Subject(s)
Adaptation, Physiological , Walking , Exercise Test , Gait , Humans , Walking Speed
15.
J Neuroeng Rehabil ; 18(1): 161, 2021 11 07.
Article in English | MEDLINE | ID: mdl-34743714

ABSTRACT

BACKGROUND: Load carriage is common in a wide range of professions, but prolonged load carriage is associated with increased fatigue and overuse injuries. Exoskeletons could improve the quality of life of these professionals by reducing metabolic cost to combat fatigue and reducing muscle activity to prevent injuries. Current exoskeletons have reduced the metabolic cost of loaded walking by up to 22% relative to walking in the device with no assistance when assisting one or two joints. Greater metabolic reductions may be possible with optimized assistance of the entire leg. METHODS: We used human-in the-loop optimization to optimize hip-knee-ankle exoskeleton assistance with no additional load, a light load (15% of body weight), and a heavy load (30% of body weight) for three participants. All loads were applied through a weight vest with an attached waist belt. We measured metabolic cost, exoskeleton assistance, kinematics, and muscle activity. We performed Friedman's tests to analyze trends across worn loads and paired t-tests to determine whether changes from the unassisted conditions to the assisted conditions were significant. RESULTS: Exoskeleton assistance reduced the metabolic cost of walking relative to walking in the device without assistance for all tested conditions. Exoskeleton assistance reduced the metabolic cost of walking by 48% with no load (p = 0.05), 41% with the light load (p = 0.01), and 43% with the heavy load (p = 0.04). The smaller metabolic reduction with the light load may be due to insufficient participant training or lack of optimizer convergence. The total applied positive power was similar for all tested conditions, and the positive knee power decreased slightly as load increased. Optimized torque timing parameters were consistent across participants and load conditions while optimized magnitude parameters varied. CONCLUSIONS: Whole-leg exoskeleton assistance can reduce the metabolic cost of walking while carrying a range of loads. The consistent optimized timing parameters across participants and conditions suggest that metabolic cost reductions are sensitive to torque timing. The variable torque magnitude parameters could imply that torque magnitude should be customized to the individual, or that there is a range of useful torque magnitudes. Future work should test whether applying the load to the exoskeleton rather than the person's torso results in larger benefits.


Subject(s)
Exoskeleton Device , Ankle/physiology , Ankle Joint/physiology , Biomechanical Phenomena/physiology , Energy Metabolism/physiology , Humans , Quality of Life , Walking/physiology
16.
J Neuroeng Rehabil ; 18(1): 152, 2021 10 18.
Article in English | MEDLINE | ID: mdl-34663372

ABSTRACT

BACKGROUND: Autonomous exoskeletons will need to be useful at a variety of walking speeds, but it is unclear how optimal hip-knee-ankle exoskeleton assistance should change with speed. Biological joint moments tend to increase with speed, and in some cases, optimized ankle exoskeleton torques follow a similar trend. Ideal hip-knee-ankle exoskeleton torque may also increase with speed. The purpose of this study was to characterize the relationship between walking speed, optimal hip-knee-ankle exoskeleton assistance, and the benefits to metabolic energy cost. METHODS: We optimized hip-knee-ankle exoskeleton assistance to reduce metabolic cost for three able-bodied participants walking at 1.0 m/s, 1.25 m/s and 1.5 m/s. We measured metabolic cost, muscle activity, exoskeleton assistance and kinematics. We performed Friedman's tests to analyze trends across walking speeds and paired t-tests to determine if changes from the unassisted conditions to the assisted conditions were significant. RESULTS: Exoskeleton assistance reduced the metabolic cost of walking compared to wearing the exoskeleton with no torque applied by 26%, 47% and 50% at 1.0, 1.25 and 1.5 m/s, respectively. For all three participants, optimized exoskeleton ankle torque was the smallest for slow walking, while hip and knee torque changed slightly with speed in ways that varied across participants. Total applied positive power increased with speed for all three participants, largely due to increased joint velocities, which consistently increased with speed. CONCLUSIONS: Exoskeleton assistance is effective at a range of speeds and is most effective at medium and fast walking speeds. Exoskeleton assistance was less effective for slow walking, which may explain the limited success in reducing metabolic cost for patient populations through exoskeleton assistance. Exoskeleton designers may have more success when targeting activities and groups with faster walking speeds. Speed-related changes in optimized exoskeleton assistance varied by participant, indicating either the benefit of participant-specific tuning or that a wide variety of torque profiles are similarly effective.


Subject(s)
Exoskeleton Device , Walking Speed , Ankle , Ankle Joint , Biomechanical Phenomena , Gait , Humans , Walking
17.
Sci Robot ; 6(58): eabf1078, 2021 Sep 29.
Article in English | MEDLINE | ID: mdl-34586837

ABSTRACT

Exoskeletons can enhance human mobility, but we still know little about why they are effective. For example, we do not know the relative importance of training, how much is required, or what type is most effective; how people adapt with the device; or the relative benefits of customizing assistance. We conducted experiments in which naïve users learned to walk with ankle exoskeletons under one of three training regimens characterized by different levels of variation in device behavior. Assistance was also customized for one group. After moderate-variation training, the benefits of customized assistance were large; metabolic rate was reduced by 39% compared with walking with the exoskeleton turned off. Training contributed about half of this benefit and customization about one-quarter; a generic controller reduced energy cost by 10% before training and 31% afterward. Training required much more exposure than typical of exoskeleton studies, about 109 minutes of assisted walking. Type of training also had a strong effect; the low-variation group required twice as long as the moderate-variation group to become expert, and the high-variation group never acquired this level of expertise. Curiously, all users adapted in a way that resulted in less mechanical power from the exoskeleton as they gained expertise. Customizing assistance required less time than training for all parameters except peak torque magnitude, which grew slowly over the study, suggesting a longer time scale adaptation in the person. These results underscore the importance of training to the benefits of exoskeleton assistance and suggest the topic deserves more attention.


Subject(s)
Adaptation, Physiological , Ankle , Exoskeleton Device , Robotics/instrumentation , Walking , Adult , Ankle Joint , Biomechanical Phenomena , Electromyography/methods , Equipment Design , Female , Gait , Humans , Male , Muscle, Skeletal , Torque , Young Adult
18.
Nat Commun ; 12(1): 4312, 2021 07 13.
Article in English | MEDLINE | ID: mdl-34257310

ABSTRACT

Physical inactivity is the fourth leading cause of global mortality. Health organizations have requested a tool to objectively measure physical activity. Respirometry and doubly labeled water accurately estimate energy expenditure, but are infeasible for everyday use. Smartwatches are portable, but have significant errors. Existing wearable methods poorly estimate time-varying activity, which comprises 40% of daily steps. Here, we present a Wearable System that estimates metabolic energy expenditure in real-time during common steady-state and time-varying activities with substantially lower error than state-of-the-art methods. We perform experiments to select sensors, collect training data, and validate the Wearable System with new subjects and new conditions for walking, running, stair climbing, and biking. The Wearable System uses inertial measurement units worn on the shank and thigh as they distinguish lower-limb activity better than wrist or trunk kinematics and converge more quickly than physiological signals. When evaluated with a diverse group of new subjects, the Wearable System has a cumulative error of 13% across common activities, significantly less than 42% for a smartwatch and 44% for an activity-specific smartwatch. This approach enables accurate physical activity monitoring which could enable new energy balance systems for weight management or large-scale activity monitoring.


Subject(s)
Energy Metabolism/physiology , Leg/physiology , Walking/physiology , Wearable Electronic Devices , Exercise/physiology , Humans
19.
Front Neurorobot ; 15: 653409, 2021.
Article in English | MEDLINE | ID: mdl-34122032

ABSTRACT

Lower-limb exoskeletons often use torque control to manipulate energy flow and ensure human safety. The accuracy of the applied torque greatly affects how well the motion is assisted and therefore improving it is always of interest. Feed-forward iterative learning, which is similar to predictive stride-wise integral control, has proven an effective compensation to feedback control for torque tracking in exoskeletons with complicated dynamics during human walking. Although the intention of iterative learning was initially to benefit average tracking performance over multiple strides, we found that, after proper gain tuning, it can also help improve real-time torque tracking. We used theoretical analysis to predict an optimal iterative-learning gain as the inverse of the passive actuator stiffness. Walking experiments resulted in an optimum gain equal to 0.99 ± 0.38 times the predicted value, confirming our hypothesis. The results of this study provide guidance for the design of torque controllers in robotic legged locomotion systems and will help improve the performance of robots that assist gait.

20.
R Soc Open Sci ; 8(5): 202020, 2021 May 05.
Article in English | MEDLINE | ID: mdl-34035945

ABSTRACT

Human-in-the-loop optimization allows for individualized device control based on measured human performance. This technique has been used to produce large reductions in energy expenditure during walking with exoskeletons but has not yet been applied to prosthetic devices. In this series of case studies, we applied human-in-the-loop optimization to the control of an active ankle-foot prosthesis used by participants with unilateral transtibial amputation. We optimized the parameters of five control architectures that captured aspects of successful exoskeletons and commercial prostheses, but none resulted in significantly lower metabolic rate than generic control. In one control architecture, we increased the exposure time per condition by a factor of five, but the optimized controller still resulted in higher metabolic rate. Finally, we optimized for self-reported comfort instead of metabolic rate, but the resulting controller was not preferred. There are several reasons why human-in-the-loop optimization may have failed for people with amputation. Control architecture is an unlikely cause given the variety of controllers tested. The lack of effect likely relates to changes in motor adaptation, learning, or objectives in people with amputation. Future work should investigate these potential causes to determine whether human-in-the-loop optimization for prostheses could be successful.

SELECTION OF CITATIONS