Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 269
Filter
1.
Article in English | MEDLINE | ID: mdl-38802043

ABSTRACT

OBJECTIVE: Our objective was to analyze the development of aortic insufficiency in patients who received central aortic valve repair when undergoing continuous-flow left ventricular assist device implantation. METHODS: We conducted a retrospective review of patients who underwent HeartMate II or 3 (Abbott Lab) implantation between 2004 and 2022. Ninety-four patients were excluded from analysis for history of aortic valve procedures, a bicuspid aortic valve, baseline trace aortic insufficiency, or other concomitant aortic valve procedure. Patients who had ≥ mild aortic insufficiency had concomitant aortic valve repair. Clinical characteristics, serial echocardiograms, and outcomes were determined. RESULTS: Of the 656 patients who underwent HeartMate II or 3 implantation, 105 patients (59 HeartMate II and 46 HeartMate 3) met study criteria. Median age was 68 years [60-74 years], 91.4% [n=96] were male, 54.4% [n=56] were white, and 68.6% [n=72] received support as destination therapy. Preoperative aortic insufficiency degree was 54.3% (n=57) mild, 23.8% (n=25) mild-to-moderate, 20.0% (n=21) moderate, 1.0% (n=1) moderate-to-severe, 1.0% (n=1) severe. In hospital mortality was 5.7% [n=6]. Freedom from ≥ moderate aortic insufficiency was 96.4% (95%CI: 92.5%-100%), 93.3% (95%CI: 87.6%-99.2%), and 91.0% (95%CI: 84.1%-98.5%) at 1-year, 2-year, and 3-year post-implantation, respectively. One HeartMate II patient experienced severe aortic insufficiency and was treated with a heart transplant. Three-year survival was 63.4% [95%CI: 52.9%-75.9%]. CONCLUSIONS: Central aortic valve repair may be an effective technique to mitigate aortic insufficiency in HeartMate II and 3. A larger cohort study with longer duration of follow up is warranted to further investigate the clinical impact.

2.
Article in English | MEDLINE | ID: mdl-38744352

ABSTRACT

BACKGROUND: Sarcopenia, characterized by loss of muscle mass and function, is prevalent in heart failure (HF) and predicts poor outcomes. We investigated alterations in sarcopenia index (SI), a surrogate for skeletal muscle mass, in HF, left ventricular assist device (LVAD) and heart transplant (HT), and assessed its relationship with inflammation and digestive tract (gut and oral) microbiota. METHODS: We enrolled 460 HF, LVAD and HT patients. Repeated measures pre/post procedures were obtained prospectively in a subset of LVAD and HT patients. SI (serum Creatinine/Cystatin C) and inflammatory biomarkers (C-reactive protein, interleukin-6, tumor necrosis factor-alpha) were measured in 271 and 622 blood samples, respectively. Gut and saliva microbiota were assessed via 16S rRNA sequencing among 335 stool and 341 saliva samples. Multivariable regression assessed the relationship between SI and i) New York Heart Association class; ii) pre- vs. post-LVAD or HT; iii) biomarkers of inflammation and microbial diversity. RESULTS: Median (interquartile range) natural logarithm (ln)-SI was -0.13 (-0.32,0.05). Ln-SI decreased across worsening HF class, further declined at 1-month after LVAD and HT and rebounded over time. Ln-SI was correlated with inflammation (r=-0.28, p<0.01), and gut (r=0.28, p<0.01) and oral microbial diversity (r=0.24, p<0.01), these associations remained significant after multivariable adjustment in the combined cohort but not for all individual cohorts. Presence of the gut taxa Roseburia inulinivorans was associated with increased SI. CONCLUSIONS: SI levels decreased in symptomatic HF and remained decreased long-term after LVAD and HT. In the combined cohort, SI levels covaried with inflammation in a similar fashion and significantly related to overall microbial (gut and oral) diversity, including specific taxa compositional changes.

3.
medRxiv ; 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38645157

ABSTRACT

Background: We investigated the association between dietary nitrate intake and early clinical cardiometabolic risk biomarkers, and explored whether the oral microbiome modifies the association between dietary nitrate intake and cardiometabolic biomarkers. Methods: Cross-sectional data from 668 (mean [SD] age 31 [9] years, 73% women) participants was analyzed. Dietary nitrate intakes and alternative healthy eating index (AHEI) scores were calculated from food frequency questionnaire responses and a validated US food database. Subgingival 16S rRNA microbial genes (Illumina, MiSeq) were sequenced, and PICRUSt2 estimated metagenomic content. The Microbiome Induced Nitric oxide Enrichment Score (MINES) was calculated as a microbial gene abundance ratio representing enhanced net capacity for NO generation. Cardiometabolic risk biomarkers included systolic and diastolic blood pressure, HbA1c, glucose, insulin, and insulin resistance (HOMA-IR), and were regressed on nitrate intake tertiles in adjusted multivariable linear models. Results: Mean nitrate intake was 190[171] mg/day. Higher nitrate intake was associated with lower insulin, and HOMA-IR but particularly among participants with low abundance of oral nitrite enriching bacteria. For example, among participants with a low MINES, mean insulin[95%CI] levels in high vs. low dietary nitrate consumers were 5.8[5.3,6.5] vs. 6.8[6.2,7.5] (p=0.004) while respective insulin levels were 6.0[5.4,6.6] vs. 5.9[5.3,6.5] (p=0.76) among partcipants with high MINES (interaction p=0.02). Conclusion: Higher dietary nitrate intake was only associated with lower insulin and insulin resistance among individuals with reduced capacity for oral microbe-induced nitrite enrichment. These findings have implications for future precision medicine-oriented approaches that might consider assessing the oral microbiome prior to enrollment into dietary interventions or making dietary recommendations.

4.
Clin Transplant ; 38(3): e15251, 2024 03.
Article in English | MEDLINE | ID: mdl-38504576

ABSTRACT

BACKGROUND: Belatacept (BTC), a fusion protein, selectively inhibits T-cell co-stimulation by binding to the CD80 and CD86 receptors on antigen-presenting cells (APCs) and has been used as immunosuppression in adult renal transplant recipients. However, data regarding its use in heart transplant (HT) recipients are limited. This retrospective cohort study aimed to delineate BTC's application in HT, focusing on efficacy, safety, and associated complications at a high-volume HT center. METHODS: A retrospective cohort study was conducted of patients who underwent HT between January 2017 and December 2021 and subsequently received BTC as part of their immunosuppressive regimen. Twenty-one HT recipients were identified. Baseline characteristics, history of rejection, and indication for BTC use were collected. Outcomes included renal function, graft function, allograft rejection and mortality. Follow-up data were collected through December 2023. RESULTS: Among 776 patients monitored from January 2017 to December 2021 21 (2.7%) received BTC treatment. Average age at transplantation was 53 years (± 12 years), and 38% were women. BTC administration began, on average, 689 [483, 1830] days post-HT. The primary indications for BTC were elevated pre-formed donor-specific antibodies in highly sensitized patients (66.6%) and renal sparing (23.8%), in conjunction with reduced calcineurin inhibitor dosage. Only one (4.8%) patient encountered rejection within a year of starting BTC. Graft function by echocardiography remained stable at 6 and 12 months posttreatment. An improvement was observed in serum creatinine levels (76.2% of patients), decreasing from a median of 1.58 to 1.45 (IQR [1.0-2.1] to [1.1-1.9]) over 12 months (p = .054). eGFR improved at 3 and 6 months compared with 3 months pre- BTC levels; however, this was not statistically significant (p = .24). Treatment discontinuation occurred in seven patients (33.3%) of whom four (19%) were switched back to full dose CNI. Infections occurred in 11 patients (52.4%), leading to BTC discontinuation in 4 patients (19%). CONCLUSION: In this cohort, BTC therapy was used as alternative immunosuppression for management of highly sensitized patients or for renal sparing. BTC therapy when combined with CNI dose reduction resulted in stabilization in renal function as measured through renal surrogate markers, which did not, however, reach statistical significance. Patients on BTC maintained a low rejection rate and preserved graft function. Infections were common during BTC therapy and were associated with medication pause/discontinuation in 19% of patients. Further randomized studies are needed to assess the efficacy and safety of BTC in HT recipients.


Subject(s)
Heart Transplantation , Kidney Transplantation , Adult , Humans , Female , Middle Aged , Male , Abatacept , Retrospective Studies , Kidney Transplantation/adverse effects , Immunosuppressive Agents , Calcineurin Inhibitors/therapeutic use , T-Lymphocytes , Graft Rejection/drug therapy , Graft Rejection/etiology , Transplant Recipients , Graft Survival
7.
ASAIO J ; 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38373176

ABSTRACT

In patients supported by the HeartMate 3 left ventricular assist device (HM3 LVAD), pump speed adjustments may improve hemodynamics. We investigated the hemodynamic implications of speed adjustments in HM3 recipients undergoing hemodynamic ramp tests. Clinically stable HM3 recipients who underwent routine invasive hemodynamic ramp tests between 2015 and 2022 at our center were included. Filling pressure optimization, defined as central venous pressure (CVP) <12 mm Hg and pulmonary capillary wedge pressure (PCWP) <18 mm Hg, was assessed at baseline and final pump speeds. Patients with optimized pressures were compared to nonoptimized patients. Overall 60 HM3 recipients with a median age of 62 years (56, 71) and time from LVAD implantation of 187 days (124, 476) were included. Optimized filling pressures were found in 35 patients (58%) at baseline speed. Speed was adjusted in 84% of the nonoptimized patients. Consequently, 39 patients (65%) had optimized pressures at final speed. There were no significant differences in hemodynamic findings between baseline and final speeds (p > 0.05 for all). Six and 12 month readmission-free rates were higher in optimized compared with nonoptimized patients (p = 0.03 for both), predominantly due to lower cardiac readmission-free rates (p = 0.052). In stable outpatients supported with HM3 who underwent routine ramp tests, optimized hemodynamics were achieved in only 2 of 3 of the patients. Patients with optimized pressures had lower all-cause readmission rates, primarily driven by fewer cardiac-related hospitalizations.

8.
J Clin Periodontol ; 51(5): 522-535, 2024 May.
Article in English | MEDLINE | ID: mdl-38343130

ABSTRACT

AIM: We investigated whether periodontal measures are cross-sectionally associated with prediabetes and cardiometabolic biomarkers among non-diabetic younger adults. MATERIALS AND METHODS: One thousand seventy-one participants (mean age = 32.2 years [SE = 0.3]; 73% female) from the Oral Infections, Glucose Intolerance and Insulin Resistance Study were enrolled. Full-mouth clinical attachment loss (fm-CAL), probing depth (fm-PD) and bleeding on probing were ascertained. Interproximal CAL (i-CAL) and probing depths (i-PD) served as our primary exposures. Glucose, HbA1c, insulin and insulin resistance (HOMA-IR) outcomes were assessed from fasting blood. Prediabetes was defined per American Diabetes Association guidelines. Prediabetes prevalence ratios (PR [95% CI]) and mean [SE] cardiometabolic biomarkers were regressed on periodontal variables via multivariable robust variance Poisson regression or multivariable linear regression. RESULTS: Prevalence of prediabetes was 12.5%. Fully adjusted prediabetes PR in Tertiles 3 versus 1 of mean i-CAL was 2.42 (1.77, 3.08). Fully adjusted fasting glucose estimates across i-CAL tertiles were 83.29 [0.43], 84.31 [0.37], 86.48 [0.46]; p for trend <.01. Greater percent of sites with i-PD ≥3 mm showed elevated natural-log-HOMA-IR after adjustment (0%-12% of sites = 0.33 [0.03], 13%-26% of sites = 0.39 [0.03], ≥27% of sites = 0.42 [0.03]; p for trend = .04). CONCLUSIONS: i-CAL (vs. fm-CAL) was associated with elevated fasting glucose and prediabetes, whereas i-PD (vs. fm-PD) was associated with insulin resistance. Future studies are needed to examine periodontal disease and incident prediabetes.


Subject(s)
Cardiovascular Diseases , Diabetes Mellitus , Insulin Resistance , Prediabetic State , Adult , Humans , Female , Male , Prediabetic State/epidemiology , Glucose , Blood Glucose , Glycated Hemoglobin , Diabetes Mellitus/epidemiology , Biomarkers
9.
J Heart Lung Transplant ; 43(4): 642-651, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38070663

ABSTRACT

BACKGROUND: The physiological response of the right ventricle (RV) following left ventricular assist device (LVAD) implantation is difficult to predict. We aimed to investigate RV geometric and functional changes after LVAD insertion and their effects on clinical outcomes. METHODS: We retrospectively reviewed 188 patients who underwent HeartMate 3 implantation at our center between November 2014 and September 2021. The RV end-diastolic diameter (RVEDD) and RV end-diastolic area (RVEDA) were measured on preoperative and predischarge transthoracic echocardiography. The nonadapted group included patients with increased RVEDD and RVEDA at discharge. The composite outcome was defined as death or readmission due to worsening right heart failure. RESULTS: There were 82 patients (44%) who had a nonadapted and 106 patients (56%) who had an adapted RV. Preoperatively, the nonadapted group had smaller RVEDD (46 vs 49 mm, p < 0.001) and RVEDA (27 vs 31 cm2, p < 0.001). At discharge, the nonadapted group had larger RVEDD (51 vs 43 mm, p < 0.001) and RVEDA (33 vs 27 cm2, p < 0.001). Kaplan-Meier analysis demonstrated worse 3-year survival (77% vs 91%, p = 0.006) and freedom from composite outcome (58% vs 85%, p < 0.001) in the nonadapted group. A multivariable Cox proportional hazards model showed that nonadaption (hazard ratio [HR] 3.09, 95% confidence interval [CI] 1.29-7.40, p = 0.01) and age (HR 3.73, 95% CI 1.42-9.77, p = 0.007) were independent predictors of composite outcome. CONCLUSIONS: Acute RV dimensional changes after LVAD insertion may represent intrinsic RV function and may be a useful prognostic marker.


Subject(s)
Heart Failure , Heart-Assist Devices , Ventricular Dysfunction, Right , Humans , Heart Ventricles/diagnostic imaging , Retrospective Studies , Echocardiography , Ventricular Function, Right
10.
ASAIO J ; 70(4): e65-e68, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-37963291

ABSTRACT

Despite advances in our understanding of myocardial recovery among left ventricular assist device (LVAD) patients, with 10-30% of patients achieving substantial myocardial improvement, the rates of LVAD support cessation remain extremely low (1-2%). These numbers are in stark contrast to clinical trial data where successful LVAD cessation is reported in up to 47% of patients. The majority of LVAD programs lack structured recovery programs and targeted protocols, likely underscoring the heterogeneity that exists among LVAD patients with myocardial recovery. This perspective summarizes the current medical and surgical challenges with respect to 1) identifying the appropriate candidates for LVAD cessation; 2) methods to wean LVAD support; 3) reviewing surgical techniques for cessation of current generation HeartMate 3 LVAD; and 4) approaching shared decision making for LVAD cessation between patients and providers given the uncertainties that remain in the field.


Subject(s)
Heart Failure , Heart-Assist Devices , Humans , Heart Failure/surgery , Goals
12.
J Card Fail ; 30(1): 95-99, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37625582

ABSTRACT

BACKGROUND: Aortic regurgitation (AR) is a common complication following left ventricular assist device (LVAD) implantation. We evaluated the hemodynamic implications of AR in patients with HeartMate 3 (HM3) LVAD at baseline and in response to speed changes. METHODS AND RESULTS: Clinically stable outpatients supported by HM3 who underwent a routine hemodynamic ramp test were retrospectively enrolled in this analysis. Patients were stratified based on the presence of at least mild AR at baseline speed. Hemodynamic and echocardiographic parameters were compared between the AR and non-AR groups. Sixty-two patients were identified. At the baseline LVAD speed, 29 patients (47%) had AR, while 33 patients (53%) did not. Patients with AR were older and supported on HM3 for a longer duration. At baseline speed, all hemodynamic parameters were similar between the groups including central venous pressure, pulmonary capillary wedge pressure, pulmonary arterial pressures, cardiac output and index, and pulmonary artery pulsatility index (p > 0.05 for all). During the subacute assessment, AR worsened in some, but not all, patients, with increases in LVAD speed. There were no significant differences in 1-year mortality or hospitalization rates between the groups, however, at 1-year, ≥ moderate AR and right ventricular failure (RVF) were detected in higher rates among the AR group compared to the non-AR group (45% vs. 0%; p < 0.01, and 75% vs. 36.8%; p = 0.02, respectively). CONCLUSIONS: In a cohort of stable outpatients supported with HM3 who underwent a routine hemodynamic ramp test, the presence of mild or greater AR did not impact the ability of HM3 LVADs to effectively unload the left ventricle during early subacute assessment. Although the presence of AR did not affect mortality and hospitalization rates, it resulted in higher rates of late hemodynamic-related events in the form of progressive AR and RVF.


Subject(s)
Aortic Valve Insufficiency , Heart Failure , Heart-Assist Devices , Humans , Retrospective Studies , Heart Failure/diagnosis , Heart Failure/surgery , Heart-Assist Devices/adverse effects , Aortic Valve Insufficiency/diagnosis , Aortic Valve Insufficiency/etiology , Hemodynamics/physiology
13.
J Card Fail ; 30(4): 580-591, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37625581

ABSTRACT

BACKGROUND: Venous congestion (VC) is a hallmark of symptomatic heart failure (HF) requiring hospitalization; however, its role in the pathogenesis of HF progression remains unclear. We investigated whether peripheral VC exacerbates inflammation, oxidative stress and neurohormonal and endothelial cell (EC) activation in patients with HF with reduced ejection fraction (HFrEF). METHODS AND RESULTS: Two matched groups of patients with HFrEF and with no peripheral VC vs without recent HF hospitalization were studied. We modeled peripheral VC by inflating a cuff around the dominant arm, targeting ∼ 30 mmHg increase in venous pressure (venous stress test [VST]). Blood and ECs were sampled before and after 90 minutes of VST. We studied 44 patients (age 53 ± 12 years, 32% female). Circulating endothelin-1, tumor necrosis factor-α, interleukin-6, isoprostane, angiotensin II (ang-2), angiopoietin-2, vascular cell adhesion molecule-1, and CD146 significantly increased after the VST. Enhanced endothelin-1 and angiopoietin-2 responses to the VST were present in patients with vs without recent hospitalization and were prospectively associated with incident HF-related events; 6698 messenger ribonucleic acid (mRNA probe sets were differentially expressed in ECs after VST. CONCLUSIONS: Experimental VC exacerbates inflammation, oxidative stress, neurohormonal and EC activation and promotes unfavorable transcriptome remodeling in ECs of patients with HFrEF. A distinct biological sensitivity to VC appears to be associated with high risk for HF progression.


Subject(s)
Heart Failure, Systolic , Heart Failure , Hyperemia , Humans , Female , Adult , Middle Aged , Aged , Male , Angiopoietin-2/metabolism , Endothelin-1 , Stroke Volume , Inflammation , Endothelial Cells , Oxidative Stress
14.
Article in English | MEDLINE | ID: mdl-38154500

ABSTRACT

OBJECTIVE: To compare 3-year survival and readmissions of patients who received the HeartMate 3 (HM3) left ventricular assist device (LVAD) or underwent orthotopic heart transplantation (OHT) as primary treatment for advanced heart failure. METHODS: We retrospectively analyzed 381 adult patients who received an HM3 LVAD or were listed for OHT between January 2014 and March 2021 at our center. To minimize crossover bias, OHT recipients with a prior LVAD were excluded, and HM3 patients were censored at the time of transplant. Cohorts were propensity score-matched to reduce confounding variables. The primary outcome was 3-year survival, and the secondary outcome was mean cumulative all-cause unplanned readmission. RESULTS: The study population comprised 185 HM3 patients (49%) and 196 OHT patients (51%), with 104 propensity score-matched patients in each group. After propensity score matching, there was no statistical difference in 3-year survival (83.7% for HM3 vs 87.0% for OHT; P = .91; relative risk [RR], 1.00; 95% confidence interval [CI], 0.45-2.20). In the unmatched cohorts, patients age 18 to 49 years had comparable survival with HM3 and OHT (96.9% vs 95.9%; N = 91; P = 1.00; RR, 0.92; 95% CI, 0.09-9.78). Patients age 50+ years had slightly inferior survival with HM3 (75.0% vs 83.9%; N = 290; P = .60; RR, 1.51; 95% CI, 0.85-2.68). The mean number of readmissions at 3 years was higher in the HM3 group (3.89 vs 2.05; P < .001). CONCLUSIONS: This exploratory analysis suggests that for similar patients, HM3 may provide comparable 3-year survival to OHT as a primary treatment for heart failure but may result in more readmissions.

15.
Curr Cardiol Rep ; 25(12): 1665-1675, 2023 12.
Article in English | MEDLINE | ID: mdl-37921947

ABSTRACT

PURPOSE OF THE REVIEW: Short-term and durable mechanical circulatory support (MCS) devices represent life-saving interventions for patients with cardiogenic shock and end-stage heart failure. This review will cover the epidemiology, risk factors, and treatment of stroke in this patient population. RECENT FINDINGS: Short-term devices such as intra-aortic balloon pump, Impella, TandemHeart, and Venoatrial Extracorporal Membrane Oxygenation, as well as durable continuous-flow left ventricular assist devices (LVADs), improve cardiac output and blood flow to the vital organs. However, MCS use is associated with high rates of complications, including ischemic and hemorrhagic strokes which carry a high risk for death and disability. Improvements in MCS technology have reduced but not eliminated the risk of stroke. Mitigation strategies focus on careful management of anti-thrombotic therapies. While data on therapeutic options for stroke are limited, several case series reported favorable outcomes with thrombectomy for ischemic stroke patients with large vessel occlusions, as well as with reversal of anticoagulation for those with hemorrhagic stroke. Stroke in patients treated with MCS is associated with high morbidity and mortality. Preventive strategies are targeted based on the specific form of MCS. Improvements in the design of the newest generation device have reduced the risk of ischemic stroke, though hemorrhagic stroke remains a serious complication.


Subject(s)
Heart Failure , Heart-Assist Devices , Hemorrhagic Stroke , Ischemic Stroke , Stroke , Adult , Humans , Hemorrhagic Stroke/complications , Shock, Cardiogenic/therapy , Heart-Assist Devices/adverse effects , Intra-Aortic Balloon Pumping , Stroke/prevention & control , Stroke/complications , Ischemic Stroke/complications , Treatment Outcome
16.
ASAIO J ; 2023 Nov 07.
Article in English | MEDLINE | ID: mdl-37934714

ABSTRACT

This review discusses the challenges and outcomes associated with pregnancy during left ventricular assist device (LVAD) support. Women account for a third of the heart failure population in the United States. Left ventricular assist devices have emerged as a safe and effective treatment option for patients with advanced heart failure. Pregnancy during LVAD support can occur, and it presents significant risks to both mother and fetus, including hemodynamic stress, thrombotic events, medication-associated teratogenicity, and uterine impingement. This literature review identified 10 cases of confirmed pregnancy during LVAD support, of which eight resulted in successful births. Maternal and fetal mortality occurred in one case, and there was a spontaneous abortion in one case. The review highlights the importance of a multidisciplinary approach, promotion of shared decision-making, thoughtful anticoagulation, adjustment of LVAD speed, and medication optimization to maintain hemodynamic support during pregnancy. Hemodynamic changes during pregnancy include increased cardiac output, heart rate, and plasma volume, as well as decreased systemic vascular resistance, which can impact LVAD support. Despite reduced pulsatility in LVAD-supported patients, ovulation and reproductive capacity might be preserved, and viable pregnancies may be achieved with appropriate management. The review provides insights into the risks and considerations for a viable pregnancy during LVAD support, including the need for ongoing research to inform joined decision-making.

17.
Clin Transplant ; 37(12): e15131, 2023 12.
Article in English | MEDLINE | ID: mdl-37897211

ABSTRACT

INTRODUCTION: Monitoring for graft rejection is a fundamental tenet of post-transplant follow-up. In heart transplantation (HT) in particular, rejection has been traditionally assessed with endomyocardial biopsy (EMB). EMB has potential complications and noted limitations, including interobserver variability in interpretation. Additional tests, such as basic cardiac biomarkers, cardiac imaging, gene expression profiling (GEP) scores, donor-derived cell-free DNA (dd-cfDNA) and the novel molecular microscope diagnostic system (MMDx) have become critical tools in rejection surveillance beyond standard EMB. METHODS: This paper describes an illustrative case followed by a review of MMDx within the context of other noninvasive screening modalities for rejection. CONCLUSIONS: We suggest MMDx be used to assist with early detection of rejection in cases of discordance between EMB and other noninvasive studies.


Subject(s)
Heart Transplantation , Myocardium , Humans , Myocardium/pathology , Heart Transplantation/adverse effects , Biopsy , Gene Expression Profiling , Graft Rejection/diagnosis , Graft Rejection/etiology , Graft Rejection/epidemiology
18.
Article in English | MEDLINE | ID: mdl-37824209

ABSTRACT

OBJECTIVES: Lateral thoracotomy (LT) approach may preserve the right ventricular (RV) function after left ventricular assist device (LVAD) implantation. This study evaluated the short- and long-term RV function using echocardiography after LVAD implantation via LT or median sternotomy (sternotomy). METHODS: The patients who underwent HeartMate 3 implantation were retrospectively reviewed. The RV function was assessed before and 1 month and 1 year after LVAD implantation. The primary and secondary outcomes were all-cause mortality and a composite of death or readmission due to RV failure, respectively. RESULTS: Of the 195 patients, 55 (28%) underwent LT and 140 (72%) underwent sternotomy. There were no significant differences in the preoperative RV geometry or function. One month after the LVAD implantation, the LT group had a smaller RV end-diastolic dimension [42 (29-48) vs 47 (42-52) mm; P = 0.003] and RV end-diastolic area [25 (21-28) vs 29 (24-36) cm2; P < 0.001] and a greater RV fractional area change [30 (25-34)% vs 28 (23-31)%; P = 0.04] and peak systolic tissue velocity [8 (7-9) vs 7 (6-8) cm/s; P = 0.01]. Twenty-four patients died and 46 met the composite end point. Kaplan-Meier curve analysis did not reveal significant differences between LT and sternotomy in the 2-year survival (93% vs 83%; log-rank test, P = 0.28) and adverse event rate (76% vs 71%; log-rank test, P = 0.65). CONCLUSIONS: LT approach yielded a better-preserved RV function at 1 month; however, there were no significant differences in the 2-year survival and adverse event rates.

19.
Article in English | MEDLINE | ID: mdl-37739242

ABSTRACT

BACKGROUND: Aortic root thrombosis(ART) is a complication of continuous-flow left ventricular assist device therapy. However, the incidence and related complications of ART in HeartMate 3 (HM3) patients remain unknown. METHODS: Patients who underwent HM3 implantation from November 2014 to August 2020 at a quaternary academic medical center were included. Demographics and outcomes were abstracted from the medical record. Echocardiograms and contrast-enhanced computed tomography studies were reviewed to identify patients who developed ART and/or moderate or greater aortic insufficiency (AI) on HM3 support. RESULTS: The study cohort included 197 HM3 patients with a median postimplant follow-up of 17.5 months. Nineteen patients (9.6%) developed ART during HM3 support, and 15 patients (7.6%) developed moderate or greater AI. Baseline age, gender, race, implantation strategy, and INTERMACS classification were similar between the ART and no-ART groups. ART was associated with an increased risk of death, stroke, or aortic valve (AV) intervention (subhazard ratio [SHR] 3.60 [95% confidence interval (CI) 1.71-7.56]; p = 0.001) and moderate or greater AI (SHR 11.1 [CI 3.60-34.1]; p < 0.001) but was not associated with a statistically significantly increased risk of death or stroke on HM3 support (2.12 [0.86-5.22]; p = 0.10). Of the 19 patients with ART, 6 (31.6%) developed moderate or greater AI, necessitating more frequent AV interventions (ART: 5 AV interventions [3 surgical repairs, 1 surgical replacement, 1 transcatheter replacement; 26.3%]; no-ART: 0). CONCLUSIONS: Nearly 10% of HM3 patients developed ART during device support. ART was associated with increased risk of a composite end-point of death, stroke, or AV intervention as well as moderate or greater AI.

20.
Semin Nephrol ; 43(2): 151408, 2023 03.
Article in English | MEDLINE | ID: mdl-37619529

ABSTRACT

Recent advances in microbiome research have informed the potential role of the gut microbiota in the regulation of metabolic, cardiovascular, and renal systems, and, when altered, in the pathogenesis of various cardiometabolic disorders, including chronic kidney disease (CKD). The improved understanding of gut dysbiosis in cardiometabolic pathologies in turn has led to a vigorous quest for developing therapeutic strategies. These therapeutic strategies aim to investigate whether interventions targeting gut dysbiosis can shift the microbiota toward eubiosis and if these shifts, in turn, translate into improvements in (or prevention of) CKD and its related complications, such as premature cardiovascular disease. Existing evidence suggests that multiple interventions (eg, plant-based diets; prebiotic, probiotic, and synbiotic supplementation; constipation treatment; fecal microbiota transplantation; and intestinal dialysis) might result in favorable modulation of the gut microbiota in patients with CKD, and thereby potentially contribute to improving clinical outcomes in these patients. In this review, we summarize the current understanding of the characteristics and roles of the gut microbiota in CKD and discuss the potential of emerging gut microbiota-targeted interventions in the management of CKD.


Subject(s)
Cardiovascular Diseases , Gastrointestinal Microbiome , Probiotics , Renal Insufficiency, Chronic , Humans , Gastrointestinal Microbiome/physiology , Dysbiosis/therapy , Renal Insufficiency, Chronic/therapy , Probiotics/therapeutic use
SELECTION OF CITATIONS
SEARCH DETAIL
...