Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
J Sports Sci Med ; 20(2): 339-348, 2021 06.
Article in English | MEDLINE | ID: mdl-34211327

ABSTRACT

Post-activation performance enhancement (PAPE) is an improvement to voluntary muscle performance following a conditioning activity. There is evidence of fatigue resistance deficits in non-exercised muscles following unilateral fatiguing exercise of a contralateral muscle. The purpose of this study was to determine if a unilateral conditioning exercise protocol could induce PAPE in a contralateral, non-exercised muscle in young healthy adults. Thirty-two recreationally trained (n = 16) and athletically trained (n = 16) participants (16 males; age: 22.9 ± 2.03 years; height: 1.81 ± 0.06 m; weight: 82.8 ± 9.43 kg, and 16 females; age: 23.1 ± 2.80 years; height: 1.67 ± 0.07 m; weight: 66.4 ± 11.09 kg) were randomly allocated into two groups (dominant or non-dominant limb intervention). The experimental intervention, involved a conditioning exercise (4-repetitions of 5-seconds knee extension maximal voluntary isometric contractions: MVIC) with either the dominant (DOM) (n = 16) or non-dominant (ND) (n = 16) knee extensors with testing of the same (exercised) or contralateral (non-exercised) leg as well as a control (no conditioning exercise: n = 32) condition. Testing was performed before, 1-minute and 10-minutes after a high intensity, low volume, conditioning protocol (2 sets of 2x5-s MVIC). Pre- and post-testing included MVIC force and F100 (force developed in the first 100 ms: a proxy measure of rate of force development) and unilateral drop jump (DJ) height and contact time. There were no significant MVIC peak force or EMG nor DJ height or contact time interactions (intervention x limb dominance x time). The pre-test (0.50 ± 0.13) dominant leg MVIC F100 forces exceeded (p = 0.02) both post-test and post-10 min by a small magnitude 8.7% (d = 0.31). There was also a significant (p = 0.02) time x intervention leg x testing leg intervention, although it was observed that the control condition was as likely to demonstrate small to large magnitude changes as were the dominant and non-dominant legs. Following the conditioning activity, there was no significant evidence for non-local improvements (PAPE), or performance decreases.


Subject(s)
Muscle, Skeletal/physiology , Physical Conditioning, Human/methods , Physical Conditioning, Human/physiology , Physical Functional Performance , Electromyography , Humans , Isometric Contraction , Knee/physiology , Male , Muscle Fatigue/physiology , Young Adult
2.
JMIR Mhealth Uhealth ; 8(9): e18694, 2020 09 08.
Article in English | MEDLINE | ID: mdl-32897239

ABSTRACT

BACKGROUND: Consumer-wearable activity trackers are small electronic devices that record fitness and health-related measures. OBJECTIVE: The purpose of this systematic review was to examine the validity and reliability of commercial wearables in measuring step count, heart rate, and energy expenditure. METHODS: We identified devices to be included in the review. Database searches were conducted in PubMed, Embase, and SPORTDiscus, and only articles published in the English language up to May 2019 were considered. Studies were excluded if they did not identify the device used and if they did not examine the validity or reliability of the device. Studies involving the general population and all special populations were included. We operationalized validity as criterion validity (as compared with other measures) and construct validity (degree to which the device is measuring what it claims). Reliability measures focused on intradevice and interdevice reliability. RESULTS: We included 158 publications examining nine different commercial wearable device brands. Fitbit was by far the most studied brand. In laboratory-based settings, Fitbit, Apple Watch, and Samsung appeared to measure steps accurately. Heart rate measurement was more variable, with Apple Watch and Garmin being the most accurate and Fitbit tending toward underestimation. For energy expenditure, no brand was accurate. We also examined validity between devices within a specific brand. CONCLUSIONS: Commercial wearable devices are accurate for measuring steps and heart rate in laboratory-based settings, but this varies by the manufacturer and device type. Devices are constantly being upgraded and redesigned to new models, suggesting the need for more current reviews and research.


Subject(s)
Fitness Trackers , Wearable Electronic Devices , Energy Metabolism , Heart Rate , Humans , Reproducibility of Results
3.
J Am Vet Med Assoc ; 252(12): 1491-1502, 2018 Jun 15.
Article in English | MEDLINE | ID: mdl-29889644

ABSTRACT

OBJECTIVE To identify knowledge and practices related to rabies vaccination and serologic monitoring among animal care workers in the United States. DESIGN Cross-sectional survey. SAMPLE 2,334 animal care workers (ie, veterinarians, veterinary technicians, animal control workers, and wildlife rehabilitators). PROCEDURES Participants were contacted through relevant professional organizations to participate in an anonymous web-based survey. The survey collected demographic and occupational information, animal handling and potential rabies exposure information, and individual rabies vaccination and serologic monitoring practices. Comparisons of animal bite and rabies exposure rates were made between occupational groups. Multiple logistic regression was used to evaluate factors associated with rabies vaccination status and adherence to serologic monitoring recommendations. RESULTS Respondents reported 0.77 animal bites/person-year or 0.10 bites/1,000 animals handled. The overall rate of postexposure prophylaxis due to an occupational rabies exposure was 1.07/100 person-years. Veterinarians reported the highest rabies vaccination rate (98.7% [367/372]), followed by animal control workers (78.5% [344/438]), wildlife rehabilitators (78.2% [122/156]), and veterinary technicians (69.3% [937/1,352]). Respondents working for employers requiring rabies vaccination and serologic monitoring were 32.16 and 6.14 times, respectively, as likely to be vaccinated or have a current serologic monitoring status as were respondents working for employers without such policies. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that, given the high reported rates of animal bites and potential rabies exposures among animal care workers, improvements in rabies vaccination and serologic monitoring practices are needed.


Subject(s)
Animals, Wild , Bites and Stings/epidemiology , Health Knowledge, Attitudes, Practice , Occupational Diseases/epidemiology , Rabies/epidemiology , Adult , Animal Technicians , Animals , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Occupational Diseases/prevention & control , Occupational Exposure , Rabies/prevention & control , United States/epidemiology , Vaccination , Veterinarians
4.
Can Vet J ; 57(12): 1251-1255, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27928171

ABSTRACT

A dog from western Newfoundland was presented with paradoxical vestibular syndrome. First-stage larvae of Angiostrongylus vasorum were detected on fecal examination. Treatment with milbemycin oxime resulted in resolution of signs. This is the first report of the spread of this parasite to western Newfoundland and of paradoxical vestibular syndrome in a dog infected with A. vasorum.


Syndrome vestibulaire paradoxal chez un chien de l'ouest de Terre-Neuve infecté par des vers du cœur(Angiostrongylus vasorum). Un chien de l'ouest de Terre-Neuve a été présenté avec un syndrome vestibulaire paradoxal. Des larves de premier stade d'Angiostrongylus vasorum ont été détectées à l'examen fécal. Le traitement à l'aide d'oxime de milbémycine a produit une disparition des symptômes. Il s'agit du premier rapport de la propagation de ce parasite dans l'ouest de Terre-Neuve et du syndrome vestibulaire paradoxal chez un chien infecté par A. vasorum.(Traduit par Isabelle Vallières).


Subject(s)
Angiostrongylus/isolation & purification , Dog Diseases/parasitology , Strongylida Infections/veterinary , Vestibular Diseases/veterinary , Amines/administration & dosage , Amines/therapeutic use , Analgesics/administration & dosage , Analgesics/therapeutic use , Animals , Anthelmintics/administration & dosage , Anthelmintics/therapeutic use , Cyclohexanecarboxylic Acids/administration & dosage , Cyclohexanecarboxylic Acids/therapeutic use , Dexamethasone/administration & dosage , Dexamethasone/therapeutic use , Diphenhydramine/administration & dosage , Diphenhydramine/therapeutic use , Dog Diseases/epidemiology , Dogs , Gabapentin , Histamine Antagonists/administration & dosage , Histamine Antagonists/therapeutic use , Immunosuppressive Agents/administration & dosage , Immunosuppressive Agents/therapeutic use , Macrolides/administration & dosage , Macrolides/therapeutic use , Male , Newfoundland and Labrador/epidemiology , Strongylida Infections/drug therapy , Strongylida Infections/epidemiology , Strongylida Infections/parasitology , Vestibular Diseases/drug therapy , Vestibular Diseases/etiology , gamma-Aminobutyric Acid/administration & dosage , gamma-Aminobutyric Acid/therapeutic use
SELECTION OF CITATIONS
SEARCH DETAIL
...