Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Apher ; 10(1): 1-6, 1995.
Article in English | MEDLINE | ID: mdl-7601861

ABSTRACT

Apheresis procedures that optimize peripheral blood stem cell (PBSC) harvesting also result in a significant loss of platelets to the patient/donor because of their similar densities. We compared the percent drop in platelet count and hemoglobin concentration in the patients before and after PBSC collection using two different collection chambers with the CS-3000. A modified plateletpheresis procedure was utilized. Seven patients underwent 38 PBSC collections during steady state hematopoiesis using the standard A-35 collection chamber. At the end of the procedure, a second low-speed centrifugation of the PBSC concentrate was performed in the manual mode, with siphoning out and return of the PRP to the patient through a transfer pack. For 14 patients who underwent 113 PBSC collections, a small volume collection chamber (SVCC) was substituted for the A-35 chamber and the second centrifugation step was omitted. These patients were also primed with 4 g/m2 of cyclophosphamide. The percent drop in platelet count in the patients after the collection procedures was significantly less in the SVCC group (20.4 +/- 9.1 vs. 36.0 +/- 12.3, P = 0.000), even after correction for the difference in the volume of blood processed between the two groups (3.2 +/- 1.4 vs. 3.9 +/- 1.3, P = 0.006). The percent drop in hemoglobin concentration was also less with the SVCC both before (5.4 +/- 3.8 vs. 11.7 +/- 3.0, P = 0.000) and after (0.8 +/- 0.6 vs. 1.3 +/- 0.3, P = 0.000) correction for the difference in the volume of blood processed.(ABSTRACT TRUNCATED AT 250 WORDS)


Subject(s)
Blood Platelets , Hematopoietic Stem Cells , Plateletpheresis/methods , Adult , Blood Donors , Blood Volume , Female , Hemoglobins/analysis , Humans , Male , Platelet Count , Plateletpheresis/instrumentation
2.
J Clin Apher ; 6(3): 137-42, 1991.
Article in English | MEDLINE | ID: mdl-1787129

ABSTRACT

Bone marrow was collected from adult patients with various solid tumors who consented to participate in a study of myelo-ablative chemotherapy followed by autologous bone marrow rescue. Twenty marrow suspensions were processed by using standard Procedure 3 (PRO-3) for lymphocytapheresis without modification. A modified Procedure 1 (M-PRO-1) for plateletpheresis was employed for processing 34 marrow suspensions. For PRO-3, mononuclear cell (MNC) recovery was 68 +/- 22% of the starting marrow suspension (baseline), in a concentrate volume of 234 +/- 53 ml. MNC represented 59 +/- 27% of the total WBC count of the concentrate. The residual volume of RBC was 49 +/- 47 ml. For M-PRO-1, MNC recovery was 63 +/- 22% of the baseline in a concentrate volume of 200 +/- 8 ml. MNC comprised 94 +/- 7% of the total WBC count of the concentrate. RBC contamination was 7 +/- 3 ml. Hematopoietic recovery, defined as the post-transplant days when a sustained granulocyte count of 500/microL and a platelet count of 50,000/microL were achieved, was similar in the two groups and comparable to other reports utilizing other methods and equipment for bone marrow concentration. Personnel time was significantly reduced compared to other procedures for bone marrow concentration due to increased automation. Although there was no significant difference in MNC recovery between the two groups (P greater than 0.5), M-PRO-1 was clearly superior to PRO-3 because of the consistently high degree of purity of the MNC in the concentrate and minimal RBC contamination.(ABSTRACT TRUNCATED AT 250 WORDS)


Subject(s)
Bone Marrow/pathology , Cell Separation/instrumentation , Hematopoietic Stem Cells , Neoplasms/pathology , Adult , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Bone Marrow Transplantation , Cell Count , Humans , Transplantation, Autologous
SELECTION OF CITATIONS
SEARCH DETAIL
...