Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Dig Liver Dis ; 52(8): 800-807, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32405285

ABSTRACT

The new corona virus disease has started in Wuhan - China at the end of 2019 and quickly spread with a pandemic trend across the rest of the world. The scientific community is making an extraordinary effort to study and control the situation, but the results are just partial. Based on the most recent scientific literature and strong statements by the most prestigious international health institutions, the Italian Society of Digestive Endoscopy has drawn up some recommendations about the use of personal protective equipment, the correct way of dressing and undressing of endoscopists and nurses, before and after digestive endoscopy procedures. In addition, some other important indications are given to reduce the risk of contamination of healthcare providers during endoscopic activities, in the setting of a pandemic. Nevertheless, because of the very quick evolution of our knowledge on this issue, these recommendations must be considered as evolving, because they could change in a short time.


Subject(s)
Coronavirus Infections/prevention & control , Disease Transmission, Infectious/prevention & control , Endoscopy, Gastrointestinal/standards , Infection Control/standards , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , Aerosols/adverse effects , COVID-19 , Coronavirus Infections/transmission , Health Personnel , Humans , Infection Control/methods , Italy , Pneumonia, Viral/transmission , Safety , Societies, Medical
3.
J Clin Gastroenterol ; 50 Suppl 1: S13-5, 2016 10.
Article in English | MEDLINE | ID: mdl-27622351

ABSTRACT

Colonic diverticula are one of the most frequent conditions found during the endoscopic examination of the lower digestive tract, interestingly in >70% of people after 80 years old. Of them, only a few percentage develop complications such as acute diverticulitis or diverticular bleeding. Up to now, colonoscopy represents the most important diagnostic and therapeutic tool on the hands of the clinicians. On the basis of this the need for a standardized and reproducible approach is now emerging. This short review article is tasked to point out some open issues concerning the role of colonoscopy in diverticular disease.


Subject(s)
Colonoscopy/methods , Diverticular Diseases/diagnosis , Diverticulosis, Colonic/diagnosis , Diverticulum, Colon/surgery , Colonoscopy/trends , Humans
4.
Obes Surg ; 20(9): 1227-30, 2010 Sep.
Article in English | MEDLINE | ID: mdl-19082675

ABSTRACT

BACKGROUND: Overweight and obesity lead to serious health consequences, so that many strategies were recommended for preventing or curing this emerging problem. Treatments are various: diet, physical activity, psychotherapy, drugs, and bariatric surgery. Moreover, during these years, the use of intragastric balloon (BIB) to treat obesity increased rapidly, aimed to (1) reduce bariatric surgical risks; (2) reduce general surgical risks; (3) lead to a significant reduction in the prevalence of cardiovascular diseases, diabetes, musculoskeletal disorders and some cancers. Recently, a new device inflated with air to reduce weight has been developed since 2004 (Heliosphere BAG). METHODS: Between March 2006 and September 2006, in our unit, intragastric air-filled balloon insertion was performed under general anesthesia and endoscopic control. The balloons were removed after 6 months. We evaluated efficacy, tolerance, and safety of this technique. Seventeen patients (eight men, nine women), with a mean age of 43 +/- 10 years (range 18-65), mean basal BMI of 46 +/- 8 (range 35-58) were included, after providing informed consent. Weight and BMI loss were evaluated in all patients. RESULTS: BMI decreased 4 +/- 3 (range +0.33/-11), weight loss was 11 +/- 9 kg (range +1/-29.5; 8.5%). 14/17 patients maintain a BMI > 35 at the time of balloon removal. The difference between initial weight and BMI was statistically significant (p = 0.02 for weight and p < 0.01 for BMI, T Student test). Tolerance was very good, limited only to some dyspeptic symptoms during the first 3 days after insertion. One asymptomatic gastric ulcer was seen at the removal of balloon. Only one severe adverse effect was registered at the time of insertion (acute coronary syndrome in patient with chronic coronary disease). No serious technical problems were noted at balloon insertion. Balloon removal was more difficult and successful in 15/17 cases (one distal migration and one patient led to surgery because of balloon fragmentation). CONCLUSION: Intragastric air-filled balloon showed a good profile of efficacy and tolerance. Weight loss appeared to be equivalent to other type of balloons. On the other hand, technical problems (especially at the time of removal) probably linked to the device's material, set a low safety profile.


Subject(s)
Gastric Balloon , Obesity, Morbid/therapy , Adult , Aged , Body Mass Index , Device Removal , Female , Gastric Balloon/adverse effects , Humans , Male , Middle Aged , Weight Loss , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...