Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
1.
Circ Cardiovasc Interv ; 16(7): e012873, 2023 07.
Article in English | MEDLINE | ID: mdl-37417229

ABSTRACT

BACKGROUND: In the SCOPE I trial (Safety and Efficacy of the Symetis ACURATE Neo/TF Compared to the Edwards SAPIEN 3 Bioprosthesis), transcatheter aortic valve implantation with the self-expanding ACURATE neo (NEO) did not meet noninferiority compared with the balloon-expandable SAPIEN 3 (S3) device regarding a composite end point at 30 days due to higher rates of prosthetic valve regurgitation and acute kidney injury. Data on long-term durability of NEO are scarce. Here, we report whether early differences between NEO and S3 translate into differences in clinical outcomes or bioprosthetic valve failure 3 years after transcatheter aortic valve implantation. METHODS: Patients with severe aortic stenosis were randomized to transfemoral transcatheter aortic valve implantation with NEO or S3 at 20 European centers. Clinical outcomes at 3 years are compared using Cox proportional or Fine-Gray subdistribution hazard models by intention-to-treat. Bioprosthetic valve failure is reported for the valve-implant cohort. RESULTS: Among 739 patients, 84 of 372 patients (24.3%) had died in the NEO and 85 of 367 (25%) in the S3 group at 3 years. Comparing NEO with S3, the 3-year rates of all-cause death (hazard ratio, 0.98 [95% CI, 0.73-1.33]), stroke (subhazard ratio, 1.04 [95% CI, 0.56-1.92]), and hospitalization for congestive heart failure (subhazard ratio, 0.74 [95% CI, 0.51-1.07]) were similar between the groups. Aortic valve reinterventions were required in 4 NEO and 3 S3 patients (subhazard ratio, 1.32 [95% CI, 0.30-5.85]). New York Heart Association functional class ≤II was observed in 84% (NEO) and 85% (S3), respectively. Mean gradients remained lower after NEO at 3 years (8 versus 12 mm Hg; P<0.001). CONCLUSIONS: Early differences between NEO and S3 did not translate into significant differences in clinical outcomes or bioprosthetic valve failure throughout 3 years. REGISTRATION: URL: https://clinicaltrials.gov, Unique identifier: NCT03011346.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Prosthesis Design , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects
2.
Cardiovasc Res ; 119(3): 857-866, 2023 05 02.
Article in English | MEDLINE | ID: mdl-35727948

ABSTRACT

AIMS: The present study aims to characterize the genetic risk architecture of bicuspid aortic valve (BAV) disease, the most common congenital heart defect. METHODS AND RESULTS: We carried out a genome-wide association study (GWAS) including 2236 BAV patients and 11 604 controls. This led to the identification of a new risk locus for BAV on chromosome 3q29. The single nucleotide polymorphism rs2550262 was genome-wide significant BAV associated (P = 3.49 × 10-08) and was replicated in an independent case-control sample. The risk locus encodes a deleterious missense variant in MUC4 (p.Ala4821Ser), a gene that is involved in epithelial-to-mesenchymal transformation. Mechanistical studies in zebrafish revealed that loss of Muc4 led to a delay in cardiac valvular development suggesting that loss of MUC4 may also play a role in aortic valve malformation. The GWAS also confirmed previously reported BAV risk loci at PALMD (P = 3.97 × 10-16), GATA4 (P = 1.61 × 10-09), and TEX41 (P = 7.68 × 10-04). In addition, the genetic BAV architecture was examined beyond the single-marker level revealing that a substantial fraction of BAV heritability is polygenic and ∼20% of the observed heritability can be explained by our GWAS data. Furthermore, we used the largest human single-cell atlas for foetal gene expression and show that the transcriptome profile in endothelial cells is a major source contributing to BAV pathology. CONCLUSION: Our study provides a deeper understanding of the genetic risk architecture of BAV formation on the single marker and polygenic level.


Subject(s)
Bicuspid Aortic Valve Disease , Heart Valve Diseases , Animals , Humans , Bicuspid Aortic Valve Disease/metabolism , Bicuspid Aortic Valve Disease/pathology , Aortic Valve/pathology , Heart Valve Diseases/pathology , Genome-Wide Association Study , Zebrafish/genetics , Endothelial Cells/metabolism
3.
Thorac Cardiovasc Surg ; 71(2): 107-117, 2023 03.
Article in English | MEDLINE | ID: mdl-36446625

ABSTRACT

Transcatheter aortic valve implantation (TAVI) is now a standard procedure for the treatment of symptomatic aortic valve stenosis in many patients. In Germany, according to the annual reports from the German Institute for Quality Assurance and Transparency in Healthcare (Institut für Qualitätssicherung und Transparenz im Gesundheitswesen), the rate of serious intraprocedural complications, such as valve malpositioning or embolization, coronary obstruction, aortic dissection, annular rupture, pericardial tamponade, or severe aortic regurgitation requiring emergency cardiac surgery has decreased markedly in recent years from more than 5.5% in 2012 to 2.0% in 2019. However, with increased use, the total number of adverse events remains about 500 per year, about 100 of which require conversion to sternotomy. These, sometimes, fatal events can occur at any time and are still challenging. Therefore, the interdisciplinary TAVI heart team should be prepared and aware of possible rescue strategies.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Thoracic Surgery , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects
4.
Can J Cardiol ; 38(12): 1921-1931, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36096401

ABSTRACT

BACKGROUND: Percutaneous repair for severe tricuspid regurgitation (TR) is emerging as a viable option, but patient selection is challenging and predetermined by comorbidities. This study evaluated mid-term outcomes of transcatheter tricuspid valve repair (TTVR) in very sick inoperable patients and explored the concept of risk-based therapeutic futility. METHODS: TTVR patients treated in our centre were prospectively assigned to prohibitive-risk (PR) and high-risk (HR) subgroups, based on Society of Thoracic Surgeons (STS) Score, frailty indices, and major organ system compromise. Efficacy and safety outcomes were compared at baseline, 30 days, and 6 months. RESULTS: Thirty-three patients (mean age 81.9 ± 5.1 years) completed follow-up from May 2021 to March 2022: 18 PR (mean STS Score 15.5 ± 7%) and 15 HR (mean STS Score 6.4 ± 1.7%). The primary efficacy end point of at least 1 grade of TR reduction by 30 days was recorded in 93.9% of all patients, with no device-related adverse events. Improvement in initial New York Heart Association functional class III/IV occurred in 74% of PR and 93% of HR patients. Six-minute walk test increased by 81 ± 43.6 metres (P < 0.001) and 85.8 ± 47.9 metres (P < 0.001), respectively. Renal function tests improved by 15% (P = 0.048) and 7% (P = 0.050), while liver enzymes decreased by 18% (P = 0.020) and 28% (P = 0.052). Right ventricular systolic function increased in both subgroups by at least 24% (P < 0.001). Six-month mortality was 12.1%, with 6 hospitalisations for acute heart failure. CONCLUSIONS: TR reduction significantly affected quality of life, functional capacity, cardiac remodelling, and multiorgan involvement similarly in PR and HR patients. TTVR is feasible in very sick symptomatic patients, regardless of predicted risk.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Aged , Aged, 80 and over , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/adverse effects , Quality of Life , Treatment Outcome , Severity of Illness Index , Time Factors , Recovery of Function
5.
Front Med (Lausanne) ; 9: 871229, 2022.
Article in English | MEDLINE | ID: mdl-35602472

ABSTRACT

Introduction: Postoperative delirium (POD) is a common and serious adverse event of surgery in older people. Because of its great impact on patients' safety and quality of life, identification of modifiable risk factors could be useful. Although preoperative medication intake is assumed to be an important modifiable risk factor, the impact of anticholinergic drugs on the occurrence of POD seems underestimated in elective surgery. The aim of this study was to investigate the association between preoperative anticholinergic burden and POD. We hypothesized that a high preoperative anticholinergic burden is an independent, potentially modifiable predisposing and precipitating factor of POD in older people. Methods: Between November 2017 and April 2019, 1,470 patients of 70 years and older undergoing elective orthopedic, general, cardiac, or vascular surgery were recruited in the randomized, prospective, multicenter PAWEL trial. Anticholinergic burden of a sub-cohort of 899 patients, who did not receive a multimodal intervention for preventing POD, was assessed by two different tools at hospital admission: The established Anticholinergic Risk Scale (ARS) and the recently developed Anticholinergic Burden Score (ABS). POD was detected by confusion assessment method (CAM) and a validated post discharge medical record review. Logistic regression analyses were performed to evaluate the association between anticholinergic burden and POD. Results: POD was observed in 210 of 899 patients (23.4%). Both ARS and ABS were independently associated with POD. The association persisted after adjustment for relevant confounding factors such as age, sex, comorbidities, preoperative cognitive and physical status, number of prescribed drugs, surgery time, type of surgery and anesthesia, usage of heart-lung-machine, and treatment in intensive care unit. If a patient was taking one of the 56 drugs listed in the ABS, risk for POD was 2.7-fold higher (OR = 2.74, 95% CI = 1.55-4.94) and 1.5-fold higher per additional point on the ARS (OR = 1.54, 95% CI = 1.15-2.02). Conclusion: Preoperative anticholinergic drug exposure measured by ARS or ABS was independently associated with POD in older patients undergoing elective surgery. Therefore, identification, discontinuation or substitution of anticholinergic medication prior to surgery may be a promising approach to reduce the risk of POD in older patients.

6.
JAMA Surg ; 157(2): e216370, 2022 02 01.
Article in English | MEDLINE | ID: mdl-34910080

ABSTRACT

Importance: Delirium significantly worsens elective surgery outcomes and costs. Delirium risk is highest in elderly populations, whose surgical health care resource consumption (50%) exceeds their demographic proportion (15% to 18%) in high-resource countries. Effective nonpharmacologic delirium prevention could safely improve care in these vulnerable patients, but data from procedure-specific studies are insufficiently compelling to drive changes in practice. Delirium prevention approaches applicable to different surgical settings remain unexplored. Objective: To examine whether a multifaceted prevention intervention is effective in reducing postoperative delirium incidence and prevalence after various major surgical procedures. Design, Setting, and Participants: This stepped-wedge cluster randomized trial recruited 1470 patients 70 years and older undergoing elective orthopedic, general, or cardiac surgery from November 2017 to April 2019 from 5 German tertiary medical centers. Data were analyzed from December 2019 to July 2021. Interventions: First, structured delirium education was provided to clinical caregivers at each site. Then, the study delirium prevention team assessed patient delirium risk factors and symptoms daily. Prevention was tailored to individual patient needs and could include: cognitive, motor, and sensory stimulation; meal companionship; accompaniment during diagnostic procedures; stress relaxation; and sleep promotion. Main Outcomes and Measures: Postoperative delirium incidence and duration. Results: Of 1470 included patients, 763 (51.9%) were male, and the median (IQR) age was 77 (74-81) years. Overall, the intervention reduced postoperative delirium incidence (odds ratio, 0.87; 95% CI, 0.77-0.98; P = .02) and percentage of days with delirium (intervention, 5.3%; control, 6.9%; P = .03). The effect was significant in patients undergoing orthopedic or abdominal surgery (odds ratio, 0.59; 95% CI, 0.35-0.99; P = .047) but not cardiac surgery (odds ratio, 1.18; 95% CI, 0.70-1.99; P = .54). Conclusions and Relevance: This multifaceted multidisciplinary prevention intervention reduced postoperative delirium occurrence and days with delirium in older patients undergoing different elective surgical procedures but not cardiac procedures. These results suggest implementing this delirium prevention program will improve care and outcomes in older patients undergoing elective general and orthopedic procedures.


Subject(s)
Delirium/prevention & control , Elective Surgical Procedures , Postoperative Complications/prevention & control , Aged , Female , Germany , Humans , Male
8.
Front Aging Neurosci ; 13: 679933, 2021.
Article in English | MEDLINE | ID: mdl-34385913

ABSTRACT

Introduction: The number of elective surgeries for patients who are over 70 years of age is continuously growing. At the same time, postoperative delirium (POD) is common in older patients (5-60%) depending on predisposing risk factors, such as multimorbidity, cognitive impairment, neurodegenerative disorders and other dementing disorders, and precipitating factors, such as duration of surgery. Knowledge of individual risk profiles prior to elective surgery may help to identify patients at increased risk for development of POD. In this study, clinical and cognitive risk factors for POD were investigated in patients undergoing various elective cardiac and non-cardiac surgeries. Methods: The PAWEL study is a prospective, interventional trial on delirium prevention. At baseline, 880 inpatients at five surgical centers were recruited for sub-sample PAWEL-R. Multimodal assessments included clinical renal function, medication, American Society of Anesthesiologists (ASA) Physical Status Classification System, geriatric and cognitive assessments, which comprised the Montreal Cognitive Assessment Scale (MoCA), Trail-making Test, and Digit Span backward. Delirium incidence was monitored postoperatively by the Confusion Assessment Method (CAM) and a chart review for up to a week or until discharge. Multivariate regression models and Chi-square Automatic Interaction Detectors (CHAID) analyses were performed using delirium incidence as the primary outcome. Results: Eighteen risk factors were investigated in elective cardiovascular and orthopedic or general surgery. A total of 208 out of 880 patients (24%) developed POD. A global regression model that included all risk variables predicted delirium incidence with high accuracy (AUC = 0.81; 95% CI 0.77, 0.85). A simpler model (clinical and cognitive variables; model CLIN-COG) of 10 factors that only included surgery type, multimorbidity, renal failure, polypharmacy, ASA, cut-to-suture time, and cognition (MoCA, Digit Span backward, and preexisting dementia), however, exhibited similar predictive accuracy (AUC = 0.80; 95% CI 0.76, 0.84). Conclusion: The risk of developing POD can be estimated by preoperative assessments, such as ASA classification, expected cut-to-suture time, and short cognitive screenings. This rather efficient approach predicted POD risk over all types of surgery. Thus, a basic risk assessment including a cognitive screen can help to stratify patients at low, medium, or high POD risk to provide targeted prevention and/or management strategies for patients at risk.

9.
J Am Coll Cardiol ; 77(18): 2263-2273, 2021 05 11.
Article in English | MEDLINE | ID: mdl-33958122

ABSTRACT

BACKGROUND: Permanent pacemaker implantation (PPI) remains one of the main drawbacks of transcatheter aortic valve replacement (TAVR), but scarce data exist on PPI after valve-in-valve (ViV) TAVR, particularly with the use of newer-generation transcatheter heart valves (THVs). OBJECTIVES: The goal of this study was to determine the incidence, factors associated with, and clinical impact of PPI in a large series of ViV-TAVR procedures. METHODS: Data were obtained from the multicenter VIVID Registry and included the main baseline and procedural characteristics, in-hospital and late (median follow-up: 13 months [interquartile range: 3 to 41 months]) outcomes analyzed according to the need of periprocedural PPI. All THVs except CoreValve, Cribier-Edwards, Sapien, and Sapien XT were considered to be new-generation THVs. RESULTS: A total of 1,987 patients without prior PPI undergoing ViV-TAVR from 2007 to 2020 were included. Of these, 128 patients (6.4%) had PPI after TAVR, with a significant decrease in the incidence of PPI with the use of new-generation THVs (4.7% vs. 7.4%; p = 0.017), mainly related to a reduced PPI rate with the Evolut R/Pro versus CoreValve (3.7% vs. 9.0%; p = 0.002). There were no significant differences in PPI rates between newer-generation balloon- and self-expanding THVs (6.1% vs. 3.9%; p = 0.18). In the multivariable analysis, older age (odds ratio [OR]: 1.05 for each increase of 1 year; 95% confidence interval [CI]: 1.02 to 1.07; p = 0.001), larger THV size (OR: 1.10; 95% CI: 1.01 to 1.20; p = 0.02), and previous right bundle branch block (OR: 2.04; 95% CI: 1.00 to 4.17; p = 0.05) were associated with an increased risk of PPI. There were no differences in 30-day mortality between the PPI (4.7%) and no-PPI (2.7%) groups (p = 0.19), but PPI patients exhibited a trend toward higher mortality risk at follow-up (hazard ratio: 1.39; 95% CI: 1.02 to 1.91; p = 0.04; p = 0.08 after adjusting for age differences between groups). CONCLUSIONS: In a contemporary large series of ViV-TAVR patients, the rate of periprocedural PPI was relatively low, and its incidence decreased with the use of new-generation THV systems. PPI following ViV-TAVR was associated with a trend toward increased mortality at follow-up.


Subject(s)
Pacemaker, Artificial , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Female , Humans , Male , Prosthesis Implantation , Registries
11.
Eur Heart J ; 41(29): 2731-2742, 2020 08 01.
Article in English | MEDLINE | ID: mdl-32592401

ABSTRACT

AIMS: Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV. METHODS AND RESULTS: A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2-12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02-1.13)], age [HR 1.21 (95% CI 1.01-1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11-1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis-patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31-14.39)], device malposition [SHR 3.75 (95% CI 1.36-10.35)], EBEV [SHR 3.34 (95% CI 1.26-8.85)], and age [SHR 0.59 (95% CI 0.44-0.78)]. CONCLUSIONS: The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Female , Humans , Male , Prosthesis Design , Prosthesis Failure , Treatment Outcome
12.
Catheter Cardiovasc Interv ; 95(1): E21-E29, 2020 01.
Article in English | MEDLINE | ID: mdl-31115146

ABSTRACT

OBJECTIVES: This study reports the outcome of a highly selected transcatheter aortic valve implantation (TAVI) population. BACKGROUND: In patients with aortic valve stenosis and severe calcification of the left ventricular outflow tract and/or the annulus, the Boston Scientific Lotus valve provided a low paravalvular leakage rate omitting the risk of annular rupture. METHODS: Until now more than 3,600 TAVI procedures were performed at our institution. Between 8/2015 and 2/2017, 634 TAVI procedures were performed, of which 80 TAVI patients with severe calcifications consecutively received the Lotus valve. Valve Academic Research Consortium (VARC)-2 criteria of these procedures were prospectively documented in our institutional TAVI registry. One year follow-up for the Lotus treated patients was completed. RESULTS: Mean age was 82.0 ± 5.5 years. Device success was 95.0%. Conversion was required in two cases (2.5%). New permanent pacemaker implantation rate was 33.3%. Vascular complications occurred more frequent in comparison to non-Lotus treated patients (13.8 vs. 8.1%; p < .05): five minor and six major vascular complications (6.3 and 7.5%), including four fatal aortic injuries (three acute aortic dissections type A, one rupture of the aortic arch). Seventy-two-hour and 30-day mortality rates were also higher in Lotus patients (6.3 and 12.5% vs. 0.3 and 2.5%; each p < .05). One-year mortality in Lotus patients was 22.5%. CONCLUSIONS: In TAVI procedures with the Lotus valve occurrence of vascular complications including lethal aortic injuries and mortality rates were considerably high. Furthermore, in every TAVI procedure careful examination of the aorta should be mandatory and be a part of planning it.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/pathology , Aortic Valve/surgery , Calcinosis/surgery , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/instrumentation , Vascular Diseases/mortality , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Calcinosis/diagnostic imaging , Calcinosis/mortality , Calcinosis/physiopathology , Female , Humans , Incidence , Male , Prosthesis Design , Registries , Risk Assessment , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , Vascular Diseases/diagnostic imaging
13.
Lancet ; 394(10209): 1619-1628, 2019 11 02.
Article in English | MEDLINE | ID: mdl-31570258

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is the preferred treatment option for older patients with symptomatic severe aortic stenosis. Differences in the properties of available TAVR systems can affect clinical outcomes. Among patients undergoing TAVR, we compared the self-expanding ACURATE neo TAVR system with the balloon-expandable SAPIEN 3 TAVR system with regard to early safety and efficacy. METHODS: In this randomised non-inferiority trial, patients (aged ≥75 years) undergoing transfemoral TAVR for treatment of symptomatic severe aortic stenosis, and who were deemed to be at increased surgical risk, were recruited at 20 tertiary heart valve centres in Germany, the Netherlands, Switzerland, and the UK. Participants were randomly assigned (1:1) to receive treatment with the ACURATE neo or the SAPIEN 3 with a computer-based randomly permuted block scheme, stratified by study centre and Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) category. The primary composite safety and efficacy endpoint comprised all-cause death, any stroke, life-threatening or disabling bleeding, major vascular complications, coronary artery obstruction requiring intervention, acute kidney injury (stage 2 or 3), rehospitalisation for valve-related symptoms or congestive heart failure, valve-related dysfunction requiring repeat procedure, moderate or severe prosthetic valve regurgitation, or prosthetic valve stenosis within 30 days of the procedure. Endpoint assessors were masked to treatment allocation. Non-inferiority of ACURATE neo compared with SAPIEN 3 was assessed in the intention-to-treat population on the basis of a risk-difference margin of 7·7% for the primary composite endpoint, with a one-sided α of 0·05. This trial is registered with ClinicalTrials.gov (number NCT03011346) and is ongoing but not recruiting. FINDINGS: Between Feb 8, 2017, and Feb 2, 2019, up to 5132 patients were screened and 739 (mean age 82·8 years [SD 4·1]; median STS-PROM score 3·5% [IQR 2·6-5·0]) were enrolled. 30-day follow-up was available for 367 (99%) of 372 patients allocated to the ACURATE neo group, and 364 (99%) of 367 allocated to the SAPIEN 3 group. Within 30 days, the primary endpoint occurred in 87 (24%) patients in the ACURATE neo and in 60 (16%) in the SAPIEN 3 group; thus, non-inferiority of the ACURATE neo was not met (absolute risk difference 7·1% [upper 95% confidence limit 12·0%], p=0·42). Secondary analysis of the primary endpoint suggested superiority of the SAPIEN 3 device over the ACURATE neo device (95% CI for risk difference -1·3 to -12·9, p=0·0156). The ACURATE neo and SAPIEN 3 groups did not differ in incidence of all-cause death (nine patients [2%] vs three [1%]) and stroke (seven [2%] vs 11 [3%]); whereas acute kidney injury (11 [3%] vs three [1%]) and moderate or severe prosthetic aortic regurgitation (34 [9%] vs ten [3%]) were more common in the ACURATE neo group. INTERPRETATION: TAVR with the self-expanding ACURATE neo did not meet non-inferiority compared to the balloon-expandable SAPIEN 3 device in terms of early safety and clinical efficacy outcomes. An early composite safety and efficacy endpoint was useful in discriminating the performance of different TAVR systems. FUNDING: Boston Scientific (USA).


Subject(s)
Aortic Valve Stenosis/surgery , Bioprosthesis/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve Stenosis/epidemiology , Aortic Valve Stenosis/mortality , Cause of Death/trends , Female , Germany/epidemiology , Heart Valve Prosthesis/adverse effects , Humans , Male , Netherlands/epidemiology , Postoperative Complications/epidemiology , Prosthesis Design , Severity of Illness Index , Switzerland/epidemiology , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , United Kingdom/epidemiology
14.
Trials ; 20(1): 71, 2019 Jan 21.
Article in English | MEDLINE | ID: mdl-30665435

ABSTRACT

BACKGROUND: Postoperative delirium is a common disorder in older adults that is associated with higher morbidity and mortality, prolonged cognitive impairment, development of dementia, higher institutionalization rates, and rising healthcare costs. The probability of delirium after surgery increases with patients' age, with pre-existing cognitive impairment, and with comorbidities, and its diagnosis and treatment is dependent on the knowledge of diagnostic criteria, risk factors, and treatment options of the medical staff. In this study, we will investigate whether a cross-sectoral and multimodal intervention for preventing delirium can reduce the prevalence of delirium and postoperative cognitive decline (POCD) in patients older than 70 years undergoing elective surgery. Additionally, we will analyze whether the intervention is cost-effective. METHODS: The study will be conducted at five medical centers (with two or three surgical departments each) in the southwest of Germany. The study employs a stepped-wedge design with cluster randomization of the medical centers. Measurements are performed at six consecutive points: preadmission, preoperative, and postoperative with daily delirium screening up to day 7 and POCD evaluations at 2, 6, and 12 months after surgery. Recruitment goals are to enroll 1500 patients older than 70 years undergoing elective operative procedures (cardiac, thoracic, vascular, proximal big joints and spine, genitourinary, gastrointestinal, and general elective surgery procedures). DISCUSSION: Results of the trial should form the basis of future standards for preventing delirium and POCD in surgical wards. Key aims are the improvement of patient safety and quality of life, as well as the reduction of the long-term risk of conversion to dementia. Furthermore, from an economic perspective, we expect benefits and decreased costs for hospitals, patients, and healthcare insurances. TRIAL REGISTRATION: German Clinical Trials Register, DRKS00013311 . Registered on 10 November 2017.


Subject(s)
Cognitive Dysfunction/prevention & control , Delirium/prevention & control , Elective Surgical Procedures/adverse effects , Patient Safety , Postoperative Complications/prevention & control , Quality of Life , Aged , Aged, 80 and over , Cost-Benefit Analysis , Cross-Sectional Studies , Data Interpretation, Statistical , Humans , Outcome Assessment, Health Care , Randomized Controlled Trials as Topic , Sample Size
15.
Am J Cardiol ; 123(2): 315-322, 2019 01 15.
Article in English | MEDLINE | ID: mdl-30424871

ABSTRACT

End-stage renal disease (ESRD) affects approximately 2% to 4% of patients with severe aortic stenosis. It is because these patients have been excluded from clinical trials, the impact of transcatheter aortic valve implantation (TAVI) in this patient group has not been thoroughly investigated. Between April 2008 and March 2015, 2,000 patients (dialysis group, n = 56 [2.8%]) were consecutively enrolled when diagnosed with severe aortic stenosis and eligible to undergo TAVI. Procedural and longer-term outcomes were analyzed and adjusted for differences in baseline characteristics. Patients on dialysis had a higher periprocedural mortality (10.7% vs 1.7%; adjusted odds ratio [adjOR] 5.65, 95% confidence interval [CI] 1.91 to 16.67; p = 0.002) and a lower Valve Academic Research Consortium (VARC)-II (VARC) defined device success (adjOR 0.34, 95% CI 0.15 to 0.79; p = 0.012). At 30 days, there was an increased rate of all-cause mortality (21.4 vs 4.8%; adjOR 4.90, 95% CI 1.96 to 12.26; p = 0.001), cardiovascular (adjOR 3.67, 95% CI 1.43 to 9.41; p = 0.007) and noncardiovascular mortality (adjOR 6.28, 95% CI 1.36 to 9.41; p = 0.019), myocardial infarction (adjOR 9.39, 95% CI 1.84 to 48.03; p = 0.007), bleeding (adjOR 2.48, 95% CI 1.06 to 5.83; p = 0.036) as well as the VARC-II defined early safety combined end point (adjOR 2.97, 95% CI 1.28 to 6.90; p = 0.012) associated with dialysis. Dialysis was associated with poor survival at one (57.1% vs 84.2%) and 3 years (26.8% vs 66.9%) with or without the consideration of the first 72 hours (p <0.001; adjusted p <0.001). Although, in the multivariable regression analysis, reduced ejection fraction, peripheral arterial disease, pulmonary hypertension (PH), frailty and dialysis were associated with 1-year mortality, only PH (>60 mm Hg) remained significant in an analysis restricted to the dialysis patients (adjusted hazard ratio 2.68; 95% CI 1.18 to 5.88; p = 0.018). PH had a sensitivity of 45.8%, a specificity of 81.3%, and a positive predictive value of 64.7%. In conclusion, dialysis is an independent predictor of mortality in patients who underwent TAVI. Long-term mortality in dialysis patients appears to be largely determined by the kidney disease and/or dialysis itself whereas VARC-II defined complications are largely unaffected. An increased short-term mortality still calls for (pre-) procedural optimization.


Subject(s)
Aortic Valve Stenosis/surgery , Kidney Failure, Chronic/immunology , Renal Dialysis/mortality , Transcatheter Aortic Valve Replacement/mortality , Aged , Aged, 80 and over , Female , Germany/epidemiology , Humans , Hypertension, Pulmonary/mortality , Kidney Failure, Chronic/mortality , Kidney Failure, Chronic/therapy , Male , Myocardial Infarction/epidemiology , Postoperative Hemorrhage/epidemiology , Predictive Value of Tests , Prognosis , Registries , Sensitivity and Specificity
16.
BMJ Open ; 8(10): e022574, 2018 10 25.
Article in English | MEDLINE | ID: mdl-30366914

ABSTRACT

OBJECTIVES: Use of transcatheter aortic valve implantation (TAVI) to treat severe aortic stenosis (AS) has gained popularity, accompanied by an evolution of patient and clinical factors. We aimed to characterise changes and evaluate their impact on outcomes. SETTING: In this single-centre, German TAVIK registry patients undergoing TAVI between 2008 and 2015 were documented prospectively. PARTICIPANTS/INTERVENTIONS: 2000 consecutive patients with AS undergoing TAVI were divided in four cohorts. 500 patients underwent TAVI in each of the following time bins: April 2008 to July 2010 (cohort I), July 2010 to April 2013 (cohort II), April 2012 to October 2013 (cohort III) and October 2013 to March 2015 (cohort IV). RESULTS: The mean age was 81.8 years, without significant variation across cohorts. Compared with cohort I, prior MI (5.4%vs11.0%; p<0.001) and New York Heart Association class IV (10.0%vs3.6%; p<0.001) were less common in cohort IV. Across cohorts, there was a fall in EuroSCORE (24.3%-18.7%), frailty (48.4%-17.0%) and use of transapical access (43.6%-29.0%), while transfemoral access increased (56.4%-71.0%; p<0.001 for each). Periprocedurally, there was a fall in moderate/severe aortic regurgitation (3.2%-0.0%) and rate of unplanned cardiopulmonary bypass (4.0%-1.0%; both p<0.001). A similar trend applied to 30-day rate of major vascular complications (5.2%-1.8%; p=0.006), life-threatening bleeding (7.0%-3.0%; p<0.001) and cardiovascular mortality (4.4%-1.8%; p=0.020). One-year post-TAVI, mortality and stroke rates did not differ. CONCLUSIONS: Evolution of TAVI between 2008 and 2015 saw a trend towards its usage in lower risk patients and rapid progression towards improved safety. Evaluation and refinement should now continue to further lessen stroke and pacemaker rates.


Subject(s)
Aortic Valve Insufficiency/surgery , Percutaneous Coronary Intervention , Postoperative Complications/surgery , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/physiopathology , Female , Heart Valve Prosthesis , Hospitals, Municipal , Humans , Male , Postoperative Complications/mortality , Postoperative Complications/physiopathology , Prospective Studies , Risk Factors , Survival Analysis , Treatment Outcome
17.
Am J Cardiol ; 122(1): 149-155, 2018 07 01.
Article in English | MEDLINE | ID: mdl-29861048

ABSTRACT

We aimed to compare the outcomes of transcatheter aortic valve implantation (TAVI) with surgical aortic valve replacement (SAVR) in an elderly but nonfrail, minimally co-morbid population. Although data comparing these 2 procedures in intermediate- and low-risk patients are mounting, no distinction has been made between co-morbidity and age/gender as driving forces for surgical risk. Patients undergoing isolated TAVI or SAVR between May 2008 and March 2015 were documented. Data for 225 patients (TAVI 132, SAVR 93) aged ≥75 and <86 years and fulfilling minimal-risk criteria were analyzed. Patients who underwent TAVI were older (80.7 vs 77.4 years, p <0.0001) and had a higher mean Society of Thoracic Surgeons score (2.16% vs 1.72%, p <0.0001). Mild prosthetic valve regurgitation (odds ratio [OR] 4.9, 95% confidence interval [CI] 3.34 to 7.20) was more likely after TAVI, as were renal complications (predominantly stage I acute kidney injury; OR 2.86, 95% CI 1.79 to 4.55) and new pacemaker implantation (OR 3.33, 95% CI 1.76 to 6.26) at 30 days; however, life-threatening bleeding (OR 0.58, 95% CI 0.36 to 0.93) and reintervention for bleeding (OR 0.03, 95% CI 0.01 to 0.13) were less likely. Survival was comparable between groups at 30 days (99.2% vs 100%, p = 1.0) and 1 year (96.2% vs 96.8%, OR 0.85, 95% CI 0.20 to 3.63, p = 0.823), but it was poorer for patients who underwent TAVI at 2 years (OR 0.31, 95% CI 0.16 to 0.61). In conclusion, the short-term outcomes of TAVI in elderly, low-risk, minimally co-morbid patients appear to be similar to those of SAVR, with access-specific complications. Although these results point toward the potential for more liberal use of TAVI in minimal-risk patients, poorer midterm survival remains a concern, requiring further exploration.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Cardiac Valve Annuloplasty/methods , Postoperative Complications/epidemiology , Registries , Risk Assessment/methods , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Comorbidity , Female , Follow-Up Studies , Germany/epidemiology , Humans , Incidence , Male , Prospective Studies , Risk Factors , Survival Rate/trends , Time Factors , Treatment Outcome
18.
Eur J Cardiothorac Surg ; 54(4): 752-761, 2018 10 01.
Article in English | MEDLINE | ID: mdl-29617804

ABSTRACT

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) in patients with low coronary heights is generally denied but is not impossible. Information about these high-risk procedures is sparse. METHODS: Since May 2008, data of more than 3000 patients who had TAVI were prospectively collected in the institutional TAVI Karlsruhe registry. Characteristics, peri- and postoperative outcome of patients with low coronary heights of ≤7 mm were analysed according to the Valve Academic Research Consortium-2. RESULTS: Eighty-six patients with an average coronary height of 6.4 ± 1.1 mm (mean age 81.0 ± 5.3 years, logistic EuroSCORE I 19.6 ± 13.3%) were treated. TAVI was performed in 72 transfemoral (83.7%) and 14 transapical (16.3%) cases using 44 CoreValve/Evolut R (51.2%), 21 Sapien XT/S3 (24.4%), 14 ACURATE (16.3%), 5 Lotus (5.8%) and 2 Portico (2.3%) prostheses. Ten procedures were valve-in-valve (VinV) TAVI (VinV, 11.6%). The 72-h, 30-day, 1-year and follow-up (3.0 ± 1.6 years) mortality rates were 2.3%, 8.0%, 10.5% and 26.7%, respectively. Within 30 days, 4 cardiac deaths and 3 non-cardiac deaths occurred (4.7% and 3.5%). Three coronary obstructions (3.5%) occurred-2 during VinV TAVI. One patient was connected to extracorporeal circulation that could not be weaned later due to an unsuccessful percutaneous coronary intervention. Another patient, the only conversion (1.2%), required delayed surgical valve replacement. The third patient died of right heart failure after aortic dissection. The procedural success rate was 95.3%. VinV procedures were associated with increased follow-up deaths (P < 0.001; hazard ratio 7.96). CONCLUSIONS: Coronary-related complications in TAVI procedures in patients with coronary heights ≤7 mm occurred less frequently, but once they occurred, they were serious. These TAVI procedures are feasible, with a high procedural success rate, but meticulous preoperative planning should be mandatory. In VinV procedures, the follow-up mortality rate is increased; therefore, we do not recommend these procedures.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Coronary Occlusion/diagnosis , Coronary Vessels/diagnostic imaging , Postoperative Complications/diagnosis , Registries , Transcatheter Aortic Valve Replacement/methods , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnosis , Bioprosthesis , Coronary Angiography , Coronary Occlusion/etiology , Feasibility Studies , Female , Fluoroscopy , Follow-Up Studies , Germany/epidemiology , Humans , Incidence , Male , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Prospective Studies , Survival Rate/trends , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
19.
ASAIO J ; 64(4): e64-e67, 2018.
Article in English | MEDLINE | ID: mdl-29419538

ABSTRACT

Right heart failure (RHF) because of pulmonary hypertension (PH) is a frequently encountered clinical problem with high mortality. The last resort, if pharmacological therapy fails, is mechanical circulatory support. There is a lack of percutaneous systems to support the right ventricle (RV). Venoarterial extracorporeal membrane oxygenation is widely used as a bailout in acute RHF in non-left ventricular assist device patients. Venoarterial extracorporeal membrane oxygenation does not unload the left ventricle and may cause failure of the left ventricle if used for a longer period of time. We report the long-term use of an ECMO-based percutaneous right ventricular assist system (oxyRVAD) capable to deliver up to 6 L/min of blood flow with a returning cannula placed in the main pulmonary artery used in RHF originating from PH with poor oxygenation. We present a series of four patients on oxyRVAD (mean treatment duration 15 ± 7.6 days). Patients benefited from the system clinically; however, two patients eventually died while on oxyRVAD. Nevertheless, we provide a proof-of-concept of this system in PH patients, which is feasible and might provide a useful "bridge-to-recovery" or "bridge-to-transplant" option in the management of patients with severe RHF because of PH.


Subject(s)
Extracorporeal Membrane Oxygenation/methods , Heart-Assist Devices , Ventricular Dysfunction, Right/therapy , Female , Humans , Hypertension, Pulmonary/complications , Hypertension, Pulmonary/physiopathology , Male , Ventricular Dysfunction, Right/etiology , Ventricular Dysfunction, Right/physiopathology
20.
J Cardiovasc Surg (Torino) ; 59(5): 737-745, 2018 Oct.
Article in English | MEDLINE | ID: mdl-24525522

ABSTRACT

BACKGROUND: Aortic cross-clamping in patients with porcelain aorta is associated with high mortality and morbidity rates. The aim is to establish a new approach to improve the outcome in this high-risk population. METHODS: Between September 2007 and November 2012, 42 patients with an aortic (N.=33; 81.3±6.4 years) or mitral valve disease (N.=9; 80.3±5.7) combined with a porcelain aorta underwent aortic (AVR) or mitral valve replacement (MVR). After arterial cannulation via distal aortic arch or femoral artery, longitudinal aortotomy under total cardiopulmonary bypass (CPB) was performed. The aorta was slowly clamped, thus mobilized atherosclerotic material could leave the aorta through the open incision. Subsequent to the actual operation, the aorta was gradually unclamped. Again, plaques were flushed out via the still open aortotomy ("open proximal ascending aorta"). RESULTS: Intraoperatively, no technical no problems occurred. Mean CPB time was 92.2±27.9 min (AVR) and 92.3±36.3 min (MVR); cardiac ischemia time was 74.3±26.7 min (AVR) and 77.1±31.6 min (MVR). Surgical revision was necessary in three patients (7.1%) due to major bleedings. Two AVR-patients suffered from minor stroke and one MVR-patient from major stroke (neurological deficit rate =7.1%). Transient ischemic attacks occurred in three patients (7.1%), another three patients (7.1%) required temporary hemofiltration. Neither gastrointestinal disorders nor respiratory failure or valve-related problems were noted. 30-day mortality was 6.9%. CONCLUSIONS: Cross-clamping with "open proximal ascending aorta" is effective and the incidence of stroke and systemic embolization in patients with porcelain aorta is low compared to literature.


Subject(s)
Aortic Diseases/surgery , Aortic Valve/surgery , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/methods , Mitral Valve/surgery , Vascular Calcification/surgery , Aged , Aged, 80 and over , Aortic Diseases/complications , Aortic Diseases/diagnostic imaging , Aortic Diseases/mortality , Aortic Valve/diagnostic imaging , Cardiopulmonary Bypass , Constriction , Female , Heart Valve Diseases/complications , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/mortality , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Humans , Male , Mitral Valve/diagnostic imaging , Operative Time , Postoperative Complications/etiology , Postoperative Complications/surgery , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome , Vascular Calcification/complications , Vascular Calcification/diagnostic imaging , Vascular Calcification/mortality
SELECTION OF CITATIONS
SEARCH DETAIL
...