Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Surg Neurol Int ; 8: 87, 2017.
Article in English | MEDLINE | ID: mdl-28607821

ABSTRACT

BACKGROUND: Frameless image-guided radiosurgery (IGRS) is a safe and effective noninvasive treatment for trigeminal neuralgia (TN). This study evaluates the use of frameless IGRS to treat patients with refractory TN. METHODS: We reviewed the records of 20 patients diagnosed with TN who underwent frameless IGRS treatments between March 2012 and December 2013. Facial pain was graded using the Barrow Neurological Institute (BNI) scoring system. The initial setup uncertainty from simulation to treatment and the patient intrafraction uncertainty were measured. The median follow-up was 32 months. RESULTS: All patients' pain was BNI Grade IV or V before the frameless IGRS treatment. The mean intrafraction shift was 0.43 mm (0.28-0.76 mm), and the maximum intrafraction shift was 0.95 mm (0.53-1.99 mm). At last follow-up, 8 (40%) patients no longer required medications (BNI 1 or 2), 11 (55%) patients were pain free but required medication (BNI 3), and 1 (5%) patient had no pain relief (BNI 5). Patients who did not have prior surgery had a higher odds ratio for pain relief compared to patients who had prior surgery (14.9, P = 0.0408). CONCLUSIONS: Frameless IGRS provides comparable dosimetric and clinical outcomes to frame-based SRS in a noninvasive fashion for patients with medically refractory TN.

2.
Radiat Oncol ; 8: 283, 2013 Dec 02.
Article in English | MEDLINE | ID: mdl-24295338

ABSTRACT

BACKGROUND: Image-guidance maximizes the therapeutic index of brain irradiation by decreasing setup uncertainty. As dose-volume data emerge defining the tolerance of critical normal structures responsible for neuroendocrine function and neurocognition, minimizing clinical target volume (CTV) to planning target volume (PTV) expansion of targets near these structures potentially lessens long-term toxicity. METHODS: We reviewed the treatment records of 29 patients with brain tumors, with a total of 517 fractions analyzed. The CTV was uniformly expanded by 3 mm to create the PTV for all cases. We determined the effect of patient specific factors (prescribed medications, weight gain, tumor location) and image-guidance technique on setup uncertainty and plotted the mean +/- standard deviation for each factor. ANOVA was used to determine significance between these factors on setup uncertainty. We determined the impact of applying the initial three fraction variation as custom PTV-expansion on dose to normal structures. RESULTS: The initial 3 mm margin encompassed 88% of all measured shifts from daily imaging for all fractions. There was no difference (p = n.s.) in average setup uncertainty between CBCT or kV imaging for all patients. Vertical, lateral, longitudinal, and 3D shifts were similar (p = n.s.) between days 1, 2, and 3 imaging and later fractions. Patients prescribed sedatives experienced increased setup uncertainty (p < 0.05), while weight gain, corticosteroid administration, and anti-seizure medication did not associate with increased setup uncertainty. Patients with targets near OAR with individualized margins led to decreased OAR dose. No reductions to targets occurred with individualized PTVs. CONCLUSIONS: Daily imaging allows application of individualized CTV expansion to reduce dose to OAR responsible for neurocognition, learning, and neuroendocrine function below doses shown to correlate with long-term morbidity. The demonstrated reduction in dose to OAR in this study has implications for quality of life and provides the motivation to pursue custom PTV expansion.


Subject(s)
Brain Neoplasms/diagnostic imaging , Brain Neoplasms/radiotherapy , Glioma/radiotherapy , Meningioma/radiotherapy , Pituitary Neoplasms/radiotherapy , Cone-Beam Computed Tomography , Glioma/diagnostic imaging , Humans , Magnetic Resonance Imaging , Meningioma/diagnostic imaging , Organs at Risk , Phantoms, Imaging , Pituitary Neoplasms/diagnostic imaging , Quality of Life , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL
...