Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Surg Res ; 100(1): 99-105, 2001 Sep.
Article in English | MEDLINE | ID: mdl-11516211

ABSTRACT

BACKGROUND: Uniplanar quantitative angiography (QA) is the standard method for measuring vessel diameter during surgical and endovascular procedures. Intravascular ultrasound (IVUS), a relatively new technology, is another means of obtaining this measurement. This study was designed to validate the accuracy of these two modalities by comparing each to direct caliper measurement, the gold standard, using phantom femoral artery segments (PAS). MATERIALS AND METHODS: PAS diameter was measured with a 12.5-MHz mechanically rotating IVUS catheter (Boston Scientific Corp.) and QA (OEC Corp.) was compared to the direct caliper measurement (Mitutoyo Corp.) at 60 different locations within PAS. At each location minimal lumen diameter and perpendicular lumen diameter were measured and their mean was calculated. The intraclass correlation coefficients (ICCC) between direct caliper measurement and IVUS and uniplanar and biplanar angiography were calculated. Fisher's Z transformation was used to compare the correlation coefficients. RESULTS: The ICCC for IVUS was 0.89. The ICCCs for uniplanar and biplanar angiography were 0.73 and 0.82, respectively. IVUS correlated more closely with direct caliper measurement than uniplanar and biplanar angiography (P = 0.00008, 0.02) Biplanar angiography correlated more closely with direct caliper measurement than uniplanar angiography (P = 0.04). CONCLUSIONS: IVUS more accurately measures lumen diameter than uniplanar or biplanar angiography. Diameter measurement with biplanar angiography is more accurate than uniplanar angiography.


Subject(s)
Femoral Artery/diagnostic imaging , Phantoms, Imaging , Ultrasonography, Interventional/methods , Ultrasonography, Interventional/standards , Angiography/methods , Angiography/standards , Femoral Artery/surgery , Humans , Reproducibility of Results , Vascular Surgical Procedures
2.
Ann Vasc Surg ; 15(1): 7-12, 2001 Jan.
Article in English | MEDLINE | ID: mdl-11221948

ABSTRACT

The use of nonpenetrating clips (NPC) for vascular anastomosis is quickly becoming accepted. Studies attest to decreased anastomotic time, comparable patency rates, and decreased blood loss. Few human studies on the use of NPC have been done to date. The purpose of this study was to evaluate primary patency rates, operative time, and complications associated with NPC compared to those with standard sutures for arterial venous graft (AVG). We retrospectively reviewed the clinical course of 82 patients with a mean age of 45 years (range, 22 to 87) from February 1996 to July 1999. All patients underwent upper extremity AVG construction. The procedures were performed at a single institution, by a single, well-experienced surgeon who has extensive experience with NPC. Primary patency rates, operative time, and complications were analyzed. Overall thrombotic incidence of AVG when NPC were used (27/48, 56%) was similar to that of sutures (17/34, 50%). Thrombotic incidence within the first year was similar as well (23/48, 48% and 13/34, 38%). The mean time to primary thrombosis was similar in both groups (6.9 and 6.8 months). The operative time required to construct an AVG with NPC (83 min) was significantly less than that with sutures (96 min) (p = 0.015). There was no significant difference in incidence of graft infection or pseudoaneurysm formation. NPC for AVG reduced operative time and resulted in primary patency and complication rates similar to those associated with use of sutures. The mean time to primary thrombosis was similar for both groups. Our findings suggest an intimal hyperplastic response of a similar nature resulting in thrombosis of both NPC and sutured AVGs.


Subject(s)
Arteriovenous Shunt, Surgical/methods , Surgical Instruments , Sutures , Adult , Aged , Aged, 80 and over , Arm/blood supply , Arteriovenous Shunt, Surgical/adverse effects , Catheters, Indwelling/adverse effects , Female , Humans , Male , Middle Aged , Renal Dialysis , Retrospective Studies , Surgical Instruments/adverse effects , Sutures/adverse effects , Thrombosis/etiology , Vascular Patency
SELECTION OF CITATIONS
SEARCH DETAIL
...