Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 41
Filter
1.
J Mech Behav Biomed Mater ; 157: 106630, 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38896922

ABSTRACT

Currently, the use of autografts is the gold standard for the replacement of many damaged biological tissues. However, this practice presents disadvantages that can be mitigated through tissue-engineered implants. The aim of this study is to explore how machine learning can mechanically evaluate 2D and 3D polyvinyl alcohol (PVA) electrospun scaffolds (one twisted filament, 3 twisted filament and 3 twisted/braided filament scaffolds) for their use in different tissue engineering applications. Crosslinked and non-crosslinked scaffolds were fabricated and mechanically characterised, in dry/wet conditions and under longitudinal/transverse loading, using tensile testing. 28 machine learning models (ML) were used to predict the mechanical properties of the scaffolds. 4 exogenous variables (structure, environmental condition, crosslinking and direction of the load) were used to predict 2 endogenous variables (Young's modulus and ultimate tensile strength). ML models were able to identify 6 structures and testing conditions with comparable Young's modulus and ultimate tensile strength to ligamentous tissue, skin tissue, oral and nasal tissue, and renal tissue. This novel study proved that Classification and Regression Trees (CART) models were an innovative and easy to interpret tool to identify biomimetic electrospun structures; however, Cubist and Support Vector Machine (SVM) models were the most accurate, with R2 of 0.93 and 0.8, to predict the ultimate tensile strength and Young's modulus, respectively. This approach can be implemented to optimise the manufacturing process in different applications.

2.
Heliyon ; 10(9): e29697, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38694123

ABSTRACT

This paper aims to identify construction robotics' potential to reduce airborne virus transmission, review factors limiting the technology's adoption and highlight how similar barriers have been addressed in other industries. Construction robotics were identified and classified into 8 themes with 25 categories through a critical literature review. We undertook interviews with 4 construction contractors and conducted an online questionnaire with 32 experts from the UK (n=14) and China (n=18) who reviewed the robotic systems we identified and ranked the potential ability of each to reduce airborne virus transmission within the construction industry. The results of this study showed that construction robotics is not only beneficial to reduce airborne virus transmission, but may also help to reduce the spread of future contagious viruses. We found no significant difference (P>0.05) in practical usage and implementation barriers to construction robotics between the UK and China. Cost, training and limited awareness of robotic technologies were the main implementation barriers we identified in both countries. Both the UK and China may need to adopt strategies such as providing more financial support to small construction industries and skill training which are utilised successfully in other sectors to realise the potential of construction robotic technologies.

3.
3D Print Addit Manuf ; 11(2): e718-e730, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38689909

ABSTRACT

The demand for biomimetic and biocompatible scaffolds in equivalence of structure and material composition for the regeneration of bone tissue is relevantly high. This article is investigating a novel three-dimensional (3D) printed porous structure called bone bricks with a gradient pore size mimicking the structure of the bone tissue. Poly-ɛ-caprolactone (PCL) combined with ceramics such as hydroxyapatite (HA), ß-tricalcium phosphate (TCP), and bioglass 45S5 were successfully mixed using a melt blending method and fabricated with the use of screw-assisted extrusion-based additive manufacturing system. Bone bricks containing the same material concentration (20 wt%) were biologically characterized through proliferation and differentiation tests. Scanning electron microscopy (SEM) was used to investigate the morphology of cells on the surface of bone bricks, whereas energy dispersive X-ray (EDX) spectroscopy was used to investigate the element composition on the surface of the bone bricks. Confocal imaging was used to investigate the number of differentiated cells on the surface of bone bricks. Proliferation results showed that bone bricks containing PCL/HA content are presenting higher proliferation properties, whereas differentiation results showed that bone bricks containing PCL/Bioglass 45S5 are presenting higher differentiation properties. Confocal imaging results showed that bone bricks containing PCL/Bioglass 45S5 are presenting a higher number of differentiated cells on their surface compared with the other material contents.

4.
PLoS One ; 19(5): e0303826, 2024.
Article in English | MEDLINE | ID: mdl-38758937

ABSTRACT

BACKGROUND: The global number of people with diabetes is estimated to reach 643 million by 2030 of whom 19-34% will present with diabetic foot ulceration. Insoles which offload high-risk ulcerative regions on the foot, by removing insole material, are the main contemporary conservative treatment to maintain mobility and reduce the likelihood of ulceration. However, their effect on the rest of the foot and relationship with key gait propulsive and balance kinematics and kinetics has not been well researched. PURPOSE: The aim of this study is to investigate the effect of offloading insoles on gait kinematics, kinetics, and plantar pressure throughout the gait cycle. METHODS: 10 healthy subjects were recruited for this experiment to walk in 6 different insole conditions. Subjects walked at three speeds on a treadmill for 10 minutes while both plantar pressure and gait kinematics, kinetics were measured using an in-shoe pressure measurement insole and motion capture system/force plates. Average peak plantar pressure, pressure time integrals, gait kinematics and centre of force were analysed. RESULTS: The average peak plantar pressure and pressure time integrals changed by -30% (-68% to 3%) and -36% (-75% to -1%) at the region of interest when applying offloading insoles, whereas the heel strike and toe-off velocity changed by 15% (-6% to 32%) and 12% (-2% to 19%) whilst walking at three speeds. CONCLUSION: The study found that offloading insoles reduced plantar pressure in the region of interest with loading transferred to surrounding regions increasing the risk of higher pressure time integrals in these locations. Heel strike and toe-off velocities were increased under certain configurations of offloading insoles which may explain the higher plantar pressures and supporting the potential of integrating kinematic gait variables within a more optimal therapeutic approach. However, there was inter-individual variability in responses for all variables measured supporting individualised prescription.


Subject(s)
Calcaneus , Foot Orthoses , Gait , Pressure , Humans , Gait/physiology , Biomechanical Phenomena , Pilot Projects , Male , Female , Adult , Calcaneus/physiology , Healthy Volunteers , Shoes , Kinetics , Walking/physiology , Metatarsus/physiology , Foot/physiology
5.
iScience ; 27(3): 109098, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38380258

ABSTRACT

Percutaneous dilatational tracheostomy (PDT) is a bedside medical procedure which sites a new tracheostomy tube in the front of the neck. The critical first step is accurate placement of a needle through the neck tissues into the trachea. Misplacement occurs in around 5% of insertions, causing morbidity, mortality, and delays to recovery. We aimed to develop and evaluate a prototype medical device to improve precision of initial PDT-needle insertion. The Guidance for Tracheostomy (GiFT) system communicates the relative locations of intra-tracheal target sensor and PDT-needle sensor to the operator. In simulated "difficult neck" models, GiFT significantly improved accuracy (mean difference 10.0 mm, ANOVA p < 0.001) with ten untrained laboratory-based participants and ten experienced medical participants. GiFT resulted in slower time-to-target (mean difference 56.1 s, p < 0.001) than unguided attempts, considered clinically insignificant. Our proof-of-concept study highlights GiFT's potential to significantly improve PDT accuracy, reduce procedural complications and offer bedside PDT to more patients.

6.
Polymers (Basel) ; 15(19)2023 Sep 28.
Article in English | MEDLINE | ID: mdl-37835968

ABSTRACT

Large bone defects are clinically challenging, with up to 15% of these requiring surgical intervention due to non-union. Bone grafts (autographs or allografts) can be used but they have many limitations, meaning that polymer-based bone tissue engineered scaffolds (tissue engineering) are a more promising solution. Clinical translation of scaffolds is still limited but this could be improved by exploring the whole design space using virtual tools such as mechanobiological modeling. In tissue engineering, a significant research effort has been expended on materials and manufacturing but relatively little has been focused on shape. Most scaffolds use regular pore architecture throughout, leaving custom or irregular pore architecture designs unexplored. The aim of this paper is to introduce a virtual design environment for scaffold development and to illustrate its potential by exploring the relationship of pore architecture to bone tissue formation. A virtual design framework has been created utilizing a mechanical stress finite element (FE) model coupled with a cell behavior agent-based model to investigate the mechanobiological relationships of scaffold shape and bone tissue formation. A case study showed that modifying pore architecture from regular to irregular enabled between 17 and 33% more bone formation within the 4-16-week time periods analyzed. This work shows that shape, specifically pore architecture, is as important as other design parameters such as material and manufacturing for improving the function of bone tissue scaffold implants. It is recommended that future research be conducted to both optimize irregular pore architectures and to explore the potential extension of the concept of shape modification beyond mechanical stress to look at other factors present in the body.

7.
Front Bioeng Biotechnol ; 11: 1160760, 2023.
Article in English | MEDLINE | ID: mdl-37502104

ABSTRACT

Introduction: Gelatin is a natural polymer commonly used in biomedical applications in combination with other materials due to its high biocompatibility, biodegradability, and similarity to collagen, principal protein of the extracellular matrix (ECM). The aim of this study was to evaluate the suitability of gelatin as the sole material to manufacture tissue engineering scaffolds by electrospinning. Methods: Gelatin was electrospun in nine different concentrations onto a rotating collector and the resulting scaffold's mechanical properties, morphology and topography were assessed using mechanical testing, scanning electron microscopy and white light interferometry, respectively. After characterizing the scaffolds, the effects of the concentration of the solvents and crosslinking agent were statistically evaluated with multivariate analysis of variance and linear regressions. Results: Fiber diameter and inter-fiber separation increased significantly when the concentration of the solvents, acetic acid (HAc) and dimethyl sulfoxide (DMSO), increased. The roughness of the scaffolds decreased as the concentration of dimethyl sulfoxide increased. The mechanical properties were significantly affected by the DMSO concentration. Immersed crosslinked scaffolds did not degrade until day 28. The manufactured gelatin-based electrospun scaffolds presented comparable mechanical properties to many human tissues such as trabecular bone, gingiva, nasal periosteum, oesophagus and liver tissue. Discussion: This study revealed for the first time that biomimetic electrospun scaffolds with gelatin alone can be produced for a significant number of human tissues by appropriately setting up the levels of factors and their interactions. These findings also extend statistical relationships to a form that would be an excellent starting point for future research that could optimize factors and interactions using both traditional statistics and machine learning techniques to further develop specific human tissue.

8.
BMJ Open ; 13(5): e066524, 2023 05 08.
Article in English | MEDLINE | ID: mdl-37156585

ABSTRACT

OBJECTIVES: We aimed to design and produce a low-cost, ergonomic, hood-integrated powered air-purifying respirator (Bubble-PAPR) for pandemic healthcare use, offering optimal and equitable protection to all staff. We hypothesised that participants would rate Bubble-PAPR more highly than current filtering face piece (FFP3) face mask respiratory protective equipment (RPE) in the domains of comfort, perceived safety and communication. DESIGN: Rapid design and evaluation cycles occurred based on the identified user needs. We conducted diary card and focus group exercises to identify relevant tasks requiring RPE. Lab-based safety standards established against British Standard BS-EN-12941 and EU2016/425 covering materials; inward particulate leakage; breathing resistance; clean air filtration and supply; carbon dioxide elimination; exhalation means and electrical safety. Questionnaire-based usability data from participating front-line healthcare staff before (usual RPE) and after using Bubble-PAPR. SETTING: Overseen by a trial safety committee, evaluation progressed sequentially through laboratory, simulated, low-risk, then high-risk clinical environments of a single tertiary National Health Service hospital. PARTICIPANTS: 15 staff completed diary cards and focus groups. 91 staff from a range of clinical and non-clinical roles completed the study, wearing Bubble-PAPR for a median of 45 min (IQR 30-80 (15-120)). Participants self-reported a range of heights (mean 1.7 m (SD 0.1, range 1.5-2.0)), weights (72.4 kg (16.0, 47-127)) and body mass indices (25.3 (4.7, 16.7-42.9)). OUTCOME MEASURES: Preuse particulometer 'fit testing' and evaluation against standards by an independent biomedical engineer.Primary:Perceived comfort (Likert scale).Secondary: Perceived safety, communication. RESULTS: Mean fit factor 16 961 (10 participants). Bubble-PAPR mean comfort score 5.64 (SD 1.55) vs usual FFP3 2.96 (1.44) (mean difference 2.68 (95% CI 2.23 to 3.14, p<0.001). Secondary outcomes, Bubble-PAPR mean (SD) versus FFP3 mean (SD), (mean difference (95% CI)) were: how safe do you feel? 6.2 (0.9) vs 5.4 (1.0), (0.73 (0.45 to 0.99)); speaking to other staff 7.5 (2.4) vs 5.1 (2.4), (2.38 (1.66 to 3.11)); heard by other staff 7.1 (2.3) vs 4.9 (2.3), (2.16 (1.45 to 2.88)); speaking to patients 7.8 (2.1) vs 4.8 (2.4), (2.99 (2.36 to 3.62)); heard by patients 7.4 (2.4) vs 4.7 (2.5), (2.7 (1.97 to 3.43)); all p<0.01. CONCLUSIONS: Bubble-PAPR achieved its primary purpose of keeping staff safe from airborne particulate material while improving comfort and the user experience when compared with usual FFP3 masks. The design and development of Bubble-PAPR were conducted using a careful evaluation strategy addressing key regulatory and safety steps. TRIAL REGISTRATION NUMBER: NCT04681365.


Subject(s)
Respiratory Protective Devices , State Medicine , Humans , Health Personnel , Perception , Hospitals
9.
Polymers (Basel) ; 15(3)2023 Jan 28.
Article in English | MEDLINE | ID: mdl-36771970

ABSTRACT

This research investigates the accelerated hydrolytic degradation process of both anatomically designed bone scaffolds with a pore size gradient and a rectangular shape (biomimetically designed scaffolds or bone bricks). The effect of material composition is investigated considering poly-ε-caprolactone (PCL) as the main scaffold material, reinforced with ceramics such as hydroxyapatite (HA), ß-tricalcium phosphate (TCP) and bioglass at a concentration of 20 wt%. In the case of rectangular scaffolds, the effect of pore size (200 µm, 300 µm and 500 µm) is also investigated. The degradation process (accelerated degradation) was investigated during a period of 5 days in a sodium hydroxide (NaOH) medium. Degraded bone bricks and rectangular scaffolds were measured each day to evaluate the weight loss of the samples, which were also morphologically, thermally, chemically and mechanically assessed. The results show that the PCL/bioglass bone brick scaffolds exhibited faster degradation kinetics in comparison with the PCL, PCL/HA and PCL/TCP bone bricks. Furthermore, the degradation kinetics of rectangular scaffolds increased by increasing the pore size from 500 µm to 200 µm. The results also indicate that, for the same material composition, bone bricks degrade slower compared with rectangular scaffolds. The scanning electron microscopy (SEM) images show that the degradation process was faster on the external regions of the bone brick scaffolds (600 µm pore size) compared with the internal regions (200 µm pore size). The thermal gravimetric analysis (TGA) results show that the ceramic concentration remained constant throughout the degradation process, while differential scanning calorimetry (DSC) results show that all scaffolds exhibited a reduction in crystallinity (Xc), enthalpy (Δm) and melting temperature (Tm) throughout the degradation process, while the glass transition temperature (Tg) slightly increased. Finally, the compression results show that the mechanical properties decreased during the degradation process, with PCL/bioglass bone bricks and rectangular scaffolds presenting higher mechanical properties with the same design in comparison with the other materials.

10.
Bioengineering (Basel) ; 10(2)2023 Jan 25.
Article in English | MEDLINE | ID: mdl-36829655

ABSTRACT

INTRODUCTION: Osteoporosis is a skeletal disease that severely affects the mechanical properties of bone. It increases the porosity of cancellous bone and reduces the resistance to fractures. It has been reported in 2009 that there are approximately 500 million osteoporotic patients worldwide. Patients who suffer fractures due to fragility cost the National Healthcare Systems in the United Kingdom £4.4 billion in 2018, in Europe €56 billion in 2019, and in the United States $57 billion in 2018. Thus, osteoporosis is problematic for both patients and healthcare systems. AIM: This review is conducted for the purpose of presenting and discussing all articles introducing or investigating treatment solutions for osteoporotic patients undergoing total hip replacement. METHODS: Searches were implemented using three databases, namely Scopus, PubMed, and Web of Science to extract all relevant articles. Predetermined eligibility criteria were used to exclude articles out of the scope of the study. RESULTS: 29 articles out of 183 articles were included in this review. These articles were organised into three sections: (i) biomechanical properties and structure of osteoporotic bones, (ii) hip implant optimisations, and (iii) drug, cells, and bio-activators delivery through hydrogels. DISCUSSION: The findings of this review suggest that diagnostic tools and measurements are crucial for understanding the characteristics of osteoporosis in general and for setting patient-specific treatment plans. It was also found that attempts to overcome complications associated with osteoporosis included design optimisation of the hip implant; however, only short-term success was reported, while the long-term stability of implants was compromised by the progressive nature of osteoporosis. Finally, it was also found that targeting implantation sites with cells, drugs, and growth factors has been outworked using hydrogels, where promising results have been reported regarding enhanced osteointegration and inhibited bacterial and osteoclastic activities. CONCLUSIONS: These results may encourage investigations that explore the effects of these impregnated hydrogels on osteoporotic bones beyond metallic scaffolds and implants.

11.
Polymers (Basel) ; 16(1)2023 Dec 24.
Article in English | MEDLINE | ID: mdl-38201731

ABSTRACT

Large bone reconstruction following trauma poses significant challenges for reconstructive surgeons, leading to a healthcare burden for health systems, long-term pain for patients, and complex disorders such as infections that are difficult to resolve. The use of bone substitutes is suboptimal for substantial bone loss, as they induce localized atrophy and are generally weak, and unable to support load. A combination of strong polycaprolactone (PCL)-based scaffolds, with an average channel size of 330 µm, enriched with 20% w/w of hydroxyapatite (HA), ß-tricalcium phosphate (TCP), or Bioglass 45S5 (Bioglass), has been developed and tested for bone regeneration in a critical-size ovine femoral condyle defect model. After 6 weeks, tissue ingrowth was analyzed using X-ray computed tomography (XCT), Backscattered Electron Microscopy (BSE), and histomorphometry. At this point, all materials promoted new bone formation. Histological analysis showed no statistical difference among the different biomaterials (p > 0.05), but PCL-Bioglass scaffolds enhanced bone formation in the center of the scaffold more than the other types of materials. These materials show potential to promote bone regeneration in critical-sized defects on load-bearing sites.

12.
J Mech Behav Biomed Mater ; 134: 105418, 2022 10.
Article in English | MEDLINE | ID: mdl-36007489

ABSTRACT

Bone defect treatment is still a challenge in clinics, and synthetic bone scaffolds with adequate mechanical and biological properties are highly needed. Adequate waste and nutrient exchange of the implanted scaffold with the surrounded tissue is a major concern. Moreover, the risk of mechanical instability in the defect area during regular activity increases as the defect size increases. Thus, scaffolds with better mass transportation and mechanical properties are desired. This study introduces 3D printed polymeric scaffolds with a continuous pattern, ZigZag-Spiral pattern, for bone defects treatments. This pattern has a uniform distribution of pore size, which leads to uniform distribution of wall shear stress which is crucial for uniform differentiation of cells attached to the scaffolds. The mechanical, mass transportation, and biological properties of the 3D printed scaffolds are evaluated. The results show that the presented scaffolds have permeability similar to natural bone and, with the same porosity level, have higher mechanical properties than scaffolds with conventional lay-down patterns 0-90° and 0-45°. Finally, human mesenchymal stem cells are seeded on the scaffolds to determine the effects of geometrical microstructure on cell attachment and morphology. The results show that cells in scaffold with ZigZag-Spiral pattern infilled pores gradually, while the other patterns need more time to fill the pores. Considering mechanical, transportation, and biological properties of the considered patterns, scaffolds with ZigZag-Spiral patterns can mimic the properties of cancellous bones and be a better choice for treatments of bone defects.


Subject(s)
Bone and Bones , Tissue Scaffolds , Humans , Porosity , Printing, Three-Dimensional , Stress, Mechanical , Tissue Engineering/methods , Tissue Scaffolds/chemistry
13.
ACS Omega ; 7(9): 7515-7530, 2022 Mar 08.
Article in English | MEDLINE | ID: mdl-35284712

ABSTRACT

Large bone loss injuries require high-performance scaffolds with an architecture and material composition resembling native bone. However, most bone scaffold studies focus on three-dimensional (3D) structures with simple rectangular or circular geometries and uniform pores, not able to recapitulate the geometric characteristics of the native tissue. This paper addresses this limitation by proposing novel anatomically designed scaffolds (bone bricks) with nonuniform pore dimensions (pore size gradients) designed based on new lay-dawn pattern strategies. The gradient design allows one to tailor the properties of the bricks and together with the incorporation of ceramic materials allows one to obtain structures with high mechanical properties (higher than reported in the literature for the same material composition) and improved biological characteristics.

14.
Bioengineering (Basel) ; 9(2)2022 Jan 19.
Article in English | MEDLINE | ID: mdl-35200401

ABSTRACT

Lumbar disc herniation is one of the most common degenerative spinal conditions resulting in lower back pain and sciatica. Surgical treatment options include microdiscectomy, lumbar fusion, total disc replacement, and other minimally invasive approaches. At present, microdiscectomy procedures are the most used technique; however, the annulus fibrosus is left with a defect that without treatment may contribute to high reherniation rates and changes in the biomechanics of the lumbar spine. This paper aims to review current commercially available products that mechanically close the annulus including the AnchorKnot® suture-passing device and the Barricaid® annular closure device. Previous studies and reviews have focused mainly on a biomimetic biomaterials approach and have described some mechanical and biological requirements for an active annular repair/regeneration strategy but are still far away from clinical implementation. Therefore, in this paper we aim to create a design specification for a mechanical annular closure strategy by identifying the most important mechanical and biological design parameters, including consideration of material selection, preclinical testing requirements, and requirements for clinical implementation.

15.
Polymers (Basel) ; 14(3)2022 Jan 22.
Article in English | MEDLINE | ID: mdl-35160435

ABSTRACT

The design of scaffolds with optimal biomechanical properties for load-bearing applications is an important topic of research. Most studies have addressed this problem by focusing on the material composition and not on the coupled effect between the material composition and the scaffold architecture. Polymer-bioglass scaffolds have been investigated due to the excellent bioactivity properties of bioglass, which release ions that activate osteogenesis. However, material preparation methods usually require the use of organic solvents that induce surface modifications on the bioglass particles, compromising the adhesion with the polymeric material thus compromising mechanical properties. In this paper, we used a simple melt blending approach to produce polycaprolactone/bioglass pellets to construct scaffolds with pore size gradient. The results show that the addition of bioglass particles improved the mechanical properties of the scaffolds and, due to the selected architecture, all scaffolds presented mechanical properties in the cortical bone region. Moreover, the addition of bioglass indicated a positive long-term effect on the biological performance of the scaffolds. The pore size gradient also induced a cell spreading gradient.

16.
Int J Mol Sci ; 22(21)2021 Oct 26.
Article in English | MEDLINE | ID: mdl-34768972

ABSTRACT

The practice of combining external stimulation therapy alongside stimuli-responsive bio-scaffolds has shown massive potential for tissue engineering applications. One promising example is the combination of electrical stimulation (ES) and electroactive scaffolds because ES could enhance cell adhesion and proliferation as well as modulating cellular specialization. Even though electroactive scaffolds have the potential to revolutionize the field of tissue engineering due to their ability to distribute ES directly to the target tissues, the development of effective electroactive scaffolds with specific properties remains a major issue in their practical uses. Conductive polymers (CPs) offer ease of modification that allows for tailoring the scaffold's various properties, making them an attractive option for conductive component in electroactive scaffolds. This review provides an up-to-date narrative of the progress of CPs-based electroactive scaffolds and the challenge of their use in various tissue engineering applications from biomaterials perspectives. The general issues with CP-based scaffolds relevant to its application as electroactive scaffolds were discussed, followed by a more specific discussion in their applications for specific tissues, including bone, nerve, skin, skeletal muscle and cardiac muscle scaffolds. Furthermore, this review also highlighted the importance of the manufacturing process relative to the scaffold's performance, with particular emphasis on additive manufacturing, and various strategies to overcome the CPs' limitations in the development of electroactive scaffolds.


Subject(s)
Biocompatible Materials/chemistry , Tissue Engineering/methods , Tissue Scaffolds/chemistry , Absorbable Implants , Biomechanical Phenomena , Cell Adhesion , Cell Proliferation , Electric Conductivity , Electric Stimulation Therapy/methods , Electric Stimulation Therapy/trends , Humans , Hydrophobic and Hydrophilic Interactions , Materials Testing , Organ Specificity , Polymers/chemistry , Printing, Three-Dimensional , Tissue Engineering/trends
17.
Int J Bioprint ; 7(2): 268, 2021.
Article in English | MEDLINE | ID: mdl-33997431

ABSTRACT

There is a significant unmet clinical need to prevent amputations due to large bone loss injuries. We are addressing this problem by developing a novel, cost-effective osseointegrated prosthetic solution based on the use of modular pieces, bone bricks, made with biocompatible and biodegradable materials that fit together in a Lego-like way to form the prosthesis. This paper investigates the anatomical designed bone bricks with different architectures, pore size gradients, and material compositions. Polymer and polymer-composite 3D printed bone bricks are extensively morphological, mechanical, and biological characterized. Composite bone bricks were produced by mixing polycaprolactone (PCL) with different levels of hydroxyapatite (HA) and ß-tri-calcium phosphate (TCP). Results allowed to establish a correlation between bone bricks architecture and material composition and bone bricks performance. Reinforced bone bricks showed improved mechanical and biological results. Best mechanical properties were obtained with PCL/TCP bone bricks with 38 double zig-zag filaments and 14 spiral-like pattern filaments, while the best biological results were obtained with PCL/HA bone bricks based on 25 double zig-zag filaments and 14 spiral-like pattern filaments.

18.
Sensors (Basel) ; 21(5)2021 Mar 02.
Article in English | MEDLINE | ID: mdl-33801346

ABSTRACT

Diabetic foot ulcers (DFUs) are a life-changing complication of diabetes that can lead to amputation. There is increasing evidence that long-term management with wearables can reduce incidence and recurrence of this condition. Temperature asymmetry measurements can alert to DFU development, but measurements of dynamic information, such as rate of temperature change, are under investigated. We present a new wearable device for temperature monitoring at the foot that is personalised to account for anatomical variations at the foot. We validate this device on 13 participants with diabetes (no neuropathy) (group name D) and 12 control participants (group name C), during sitting and standing. We extract dynamic temperature parameters from four sites on each foot to compare the rate of temperature change. During sitting the time constant of temperature rise after shoe donning was significantly (p < 0.05) faster at the hallux (p = 0.032, 370.4 s (C), 279.1 s (D)) and 5th metatarsal head (p = 0.011, 481.9 s (C), 356.6 s (D)) in participants with diabetes compared to controls. No significant differences at the other sites or during standing were identified. These results suggest that temperature rise time is faster at parts of the foot in those who have developed diabetes. Elevated temperatures are known to be a risk factor of DFUs and measurement of time constants may provide information on their development. This work suggests that temperature rise time measured at the plantar surface may be an indicative biomarker for differences in soft tissue biomechanics and vascularisation during diabetes onset and progression.


Subject(s)
Diabetes Mellitus , Diabetic Foot , Wearable Electronic Devices , Foot , Humans , Printing, Three-Dimensional , Temperature
19.
Molecules ; 26(7)2021 Apr 02.
Article in English | MEDLINE | ID: mdl-33918502

ABSTRACT

Electroactive biomaterials are fascinating for tissue engineering applications because of their ability to deliver electrical stimulation directly to cells, tissue, and organs. One particularly attractive conductive filler for electroactive biomaterials is silver nanoparticles (AgNPs) because of their high conductivity, antibacterial activity, and ability to promote bone healing. However, production of AgNPs involves a toxic reducing agent which would inhibit biological scaffold performance. This work explores facile and green synthesis of AgNPs using extract of Cilembu sweet potato and studies the effect of baking and precursor concentrations (1, 10 and 100 mM) on AgNPs' properties. Transmission electron microscope (TEM) results revealed that the smallest particle size of AgNPs (9.95 ± 3.69 nm) with nodular morphology was obtained by utilization of baked extract and ten mM AgNO3. Polycaprolactone (PCL)/AgNPs scaffolds exhibited several enhancements compared to PCL scaffolds. Compressive strength was six times greater (3.88 ± 0.42 MPa), more hydrophilic (contact angle of 76.8 ± 1.7°), conductive (2.3 ± 0.5 × 10-3 S/cm) and exhibited anti-bacterial properties against Staphylococcus aureus ATCC3658 (99.5% reduction of surviving bacteria). Despite the promising results, further investigation on biological assessment is required to obtain comprehensive study of this scaffold. This green synthesis approach together with the use of 3D printing opens a new route to manufacture AgNPs-based electroactive with improved anti-bacterial properties without utilization of any toxic organic solvents.


Subject(s)
Anti-Infective Agents/pharmacology , Green Chemistry Technology , Ipomoea batatas/chemistry , Metal Nanoparticles/chemistry , Plant Extracts/chemistry , Printing, Three-Dimensional , Silver/pharmacology , Tissue Scaffolds/chemistry , Anti-Bacterial Agents/pharmacology , Bacteria/drug effects , Colloids/chemistry , Compressive Strength , Dynamic Light Scattering , Elastic Modulus , Electric Conductivity , Metal Nanoparticles/ultrastructure , Microbial Sensitivity Tests , Particle Size , Polyesters/chemistry , Spectrophotometry, Ultraviolet , Spectroscopy, Fourier Transform Infrared , Static Electricity , Wettability , X-Ray Diffraction
SELECTION OF CITATIONS
SEARCH DETAIL
...