Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 40
Filter
Add more filters










Publication year range
1.
Geochem Geophys Geosyst ; 24(2)2023 Feb.
Article in English | MEDLINE | ID: mdl-37829604

ABSTRACT

Carbonate clumped isotope geochemistry has primarily focused on mass spectrometric determination of m/z 47 CO2 for geothermometry, but theoretical calculations and recent experiments indicate paired analysis of the m/z 47 (13C18O16O) and m/z 48 (12C18O18O) isotopologues (referred to as Δ47 and Δ48) can be used to study non-equilibrium isotope fractionations and refine temperature estimates. We utilize 5,448 Δ47 and 3,400 Δ48 replicate measurements of carbonate samples and standards, and 183 Δ47 and 195 Δ48 replicate measurements of gas standards from 2015 to 2021 from a multi-year and multi-instrument data set to constrain Δ47 and Δ48 values for 27 samples and standards, including Devils Hole cave calcite, and study equilibrium Δ47-Δ48, Δ47-temperature, and Δ48-temperature relationships. We compare results to previously published findings and calculate equilibrium regressions based on data from multiple laboratories. We report acid digestion fractionation factors, Δ*63-47 and Δ*64-48, and account for their dependence on the initial clumped isotope values of the mineral.

2.
Rapid Commun Mass Spectrom ; 36(15): e8864, 2022 Aug 15.
Article in English | MEDLINE | ID: mdl-32558968

ABSTRACT

The present Table of Standard Atomic Weights (TSAW) of the elements is perhaps one of the most familiar data sets in science. Unlike most parameters in physical science whose values and uncertainties are evaluated using the "Guide to the Expression of Uncertainty in Measurement" (GUM), the majority of standard atomic-weight values and their uncertainties are consensus values, not GUM-evaluated values. The Commission on Isotopic Abundances and Atomic Weights of the International Union of Pure and Applied Chemistry (IUPAC) regularly evaluates the literature for new isotopic-abundance measurements that can lead to revised standard atomic-weight values, Ar °(E) for element E. The Commission strives to provide utmost clarity in products it disseminates, namely the TSAW and the Table of Isotopic Compositions of the Elements (TICE). In 2016, the Commission recognized that a guideline recommending the expression of uncertainty listed in parentheses following the standard atomic-weight value, for example, Ar °(Se) = 78.971(8), did not agree with the GUM, which suggests that this parenthetic notation be reserved to express standard uncertainty, not the expanded uncertainty used in the TSAW and TICE. In 2017, to eliminate this noncompliance with the GUM, a new format was adopted in which the uncertainty value is specified by the "±" symbol, for example, Ar °(Se) = 78.971 ± 0.008. To clarify the definition of uncertainty, a new footnote has been added to the TSAW. This footnote emphasizes that an atomic-weight uncertainty is a consensus (decisional) uncertainty. Not only has the Commission shielded users of the TSAW and TICE from unreliable measurements that appear in the literature as a result of unduly small uncertainties, but the aim of IUPAC has been fulfilled by which any scientist, taking any natural sample from commerce or research, can expect the sample atomic weight to lie within Ar °(E) ± its uncertainty almost all of the time.


Subject(s)
Consensus , Uncertainty
3.
Environ Sci Technol ; 55(14): 10025-10034, 2021 07 20.
Article in English | MEDLINE | ID: mdl-34197090

ABSTRACT

Tracing produced water origins from wells hydraulically fractured with freshwater-based fluids is sometimes predicated on assumptions that (1) each geological formation contains compositionally unique brine and (2) produced water from recently hydraulically fractured wells resembles fresher meteoric water more so than produced water from older wells. These assumptions are not valid in Williston Basin oil wells sampled in this study. Although distinct average 228Ra/226Ra ratios were found in water produced from the Bakken and Three Forks Formations, average δ2H, δ18O, specific gravity, and conductivity were similar but exhibited significant variability across five oil fields within each formation. Furthermore, initial produced water ("flowback") was operationally defined based on the presence of glycol ether compounds and water from wells that had produced <56% of the amount of fluids injected and sampled within 160 days of fracturing. Flowback unexpectedly exhibited higher temperature, specific gravity, conductivity, δ2H, and δ18O, but lower oxidation-reduction potential and δ11B, relative to the wells thought to be producing formation brines (from wells with a produced-to-injected water ratio [PIWR] > 0.84 and sampled more than 316 days after fracturing). As such, establishing an overall geochemical and isotopic signature of produced water compositions based solely on chemical similarity to meteoric water and formation without the consideration of well treatments, well completion depth, or lateral location across the basin could be misleading if these signatures are assumed to be applicable across the entire basin. These findings have implications for using produced water compositions to understand the interbasin fluid flow and trace sources of hydraulic fracturing fluids.


Subject(s)
Hydraulic Fracking , Water Pollutants, Chemical , Oil and Gas Fields , Wastewater , Water , Water Pollutants, Chemical/analysis , Water Wells
4.
Rapid Commun Mass Spectrom ; 35(4): e9006, 2021 Feb 28.
Article in English | MEDLINE | ID: mdl-33201519

ABSTRACT

RATIONALE: The stable carbon isotopic (δ13 C) reference material (RM) LSVEC Li2 CO3 has been found to be unsuitable for δ13 C standardization work because its δ13 C value increases with exposure to atmospheric CO2 . A new CaCO3 RM, USGS44, has been prepared to alleviate this situation. METHODS: USGS44 was prepared from 8 kg of Merck high-purity CaCO3 . Two sets of δ13 C values of USGS44 were determined. The first set of values was determined by online combustion, continuous-flow (CF) isotope-ratio mass spectrometry (IRMS) of NBS 19 CaCO3 (δ13 CVPDB = +1.95 milliurey (mUr) exactly, where mUr = 0.001 = 1‰), and LSVEC Li2 CO3 (δ13 CVPDB = -46.6 mUr exactly), and normalized to the two-anchor δ13 CVPDB-LSVEC isotope-delta scale. The second set of values was obtained by dual-inlet (DI)-IRMS of CO2 evolved by reaction of H3 PO4 with carbonates, corrected for cross contamination, and normalized to the single-anchor δ13 CVPDB scale. RESULTS: USGS44 is stable and isotopically homogeneous to within 0.02 mUr in 100-µg amounts. It has a δ13 CVPDB-LSVEC value of -42.21 ± 0.05 mUr. Single-anchor δ13 CVPDB values of -42.08 ± 0.01 and -41.99 ± 0.02 mUr were determined by DI-IRMS with corrections for cross contamination. CONCLUSIONS: The new high-purity, well-homogenized calcium carbonate isotopic reference material USGS44 is stable and has a δ13 CVPDB-LSVEC value of -42.21 ± 0.05 mUr for both EA/IRMS and DI-IRMS measurements. As a carbonate relatively depleted in 13 C, it is intended for daily use as a secondary isotopic reference material to normalize stable carbon isotope delta measurements to the δ13 CVPDB-LSVEC scale. It is useful in quantifying drift with time, determining mass-dependent isotopic fractionation (linearity correction), and adjusting isotope-ratio-scale contraction. Due to its fine grain size (smaller than 63 µm), it is not suitable as a δ18 O reference material. A δ13 CVPDB-LSVEC value of -29.99 ± 0.05 mUr was determined for NBS 22 oil.

5.
J Agric Food Chem ; 68(39): 10852-10864, 2020 Sep 30.
Article in English | MEDLINE | ID: mdl-32893631

ABSTRACT

An international project developed, quality-tested, and measured isotope-delta values of 10 new food matrix reference materials (RMs) for hydrogen, carbon, nitrogen, oxygen, and sulfur stable isotope-ratio measurements to support food authenticity testing and food provenance verification. These new RMs, USGS82 to USGS91, will enable users to normalize measurements of samples to isotope-delta scales. The RMs include (i) two honeys from Canada and tropical Vietnam, (ii) two flours from C3 (rice) and C4 (millet) plants, (iii) four vegetable oils from C3 (olive, peanut) and C4 (corn) plants, and (iv) two collagen powders from marine fish and terrestrial mammal origins. An errors-in-variables regression model included the uncertainty associated with the measured and assigned values of the RMs, and it was applied centrally to normalize results and obtain consensus values and measurement uncertainties. Utilization of these new RMs should facilitate mutual compatibility of stable isotope data if accepted normalization procedures are applied and documented.


Subject(s)
Collagen/analysis , Deuterium/analysis , Flour/analysis , Honey/analysis , Nitrogen Isotopes/analysis , Oxygen Isotopes/analysis , Plant Oils/chemistry , Sulfur Isotopes/analysis , Animals , Fish Proteins/analysis , Fishes
6.
Nat Commun ; 11(1): 4005, 2020 08 10.
Article in English | MEDLINE | ID: mdl-32778658

ABSTRACT

Surface temperature is a fundamental parameter of Earth's climate. Its evolution through time is commonly reconstructed using the oxygen isotope and the clumped isotope compositions of carbonate archives. However, reaction kinetics involved in the precipitation of carbonates can introduce inaccuracies in the derived temperatures. Here, we show that dual clumped isotope analyses, i.e., simultaneous ∆47 and ∆48 measurements on the single carbonate phase, can identify the origin and quantify the extent of these kinetic biases. Our results verify theoretical predictions and evidence that the isotopic disequilibrium commonly observed in speleothems and scleractinian coral skeletons is inherited from the dissolved inorganic carbon pool of their parent solutions. Further, we show that dual clumped isotope thermometry can achieve reliable palaeotemperature reconstructions, devoid of kinetic bias. Analysis of a belemnite rostrum implies that it precipitated near isotopic equilibrium and confirms the warmer-than-present temperatures during the Early Cretaceous at southern high latitudes.

7.
J Environ Manage ; 235: 442-452, 2019 Apr 01.
Article in English | MEDLINE | ID: mdl-30710854

ABSTRACT

Beginning in the late 1970s, 10- to 15-year cyclical oscillations in salinity were observed at lower Colorado River monitoring sites, moving upstream from the international border with Mexico, above Imperial Dam, below Hoover Dam, and at Lees Ferry. The cause of these cyclical trends in salinity was unknown. These salinity cycles complicate the U.S. Bureau of Reclamation's (Reclamation) responsibility for managing salinity in the river for delivery of water to Mexico to meet treaty obligations. This study develops a conceptual model of the salinity cycles from time-series water quality, streamflow, and precipitation data in both the lower and upper Colorado River Basins in order to provide Reclamation the ability to understand, anticipate, and manage future salinity cycles in the lower river. Compared with the Lees Ferry record, both maximum and minimum salinity levels increase downstream by about 25% at Hoover Dam, by about 49% at Imperial Dam, and by about 69% at the northern international boundary with Mexico. In the upper basin, cyclical salinity trends are evident at the outflow of three major tributaries, where salinity is also noted to be inversely related to streamflow. Time series trends in precipitation within the catchments of the three upper basin tributaries indicate cyclical periods with above normal precipitation and periods with below normal precipitation. Periods of greater than normal precipitation in the contributing areas correspond with declines in salinity at the catchment monitoring sites and periods of less than normal precipitation correspond with rising salinity at the sites. Based on the conceptual model developed in this investigation, a multiple linear regression model was developed using a stepwise variable selection procedure to simulate salinity in Lake Powell inflow. Important variables in the explanation of salinity entering Lake Powell include flow from the three upper basin tributaries, seasonality, and mean precipitation in the upper basin, among others. The root mean square error of prediction for the MLR model was 31.48 mg/L (5.7%).


Subject(s)
Environmental Monitoring , Salinity , Colorado , Mexico , Rivers
9.
Rapid Commun Mass Spectrom ; 32(15): 1207-1214, 2018 Aug 15.
Article in English | MEDLINE | ID: mdl-29729051

ABSTRACT

RATIONALE: Despite a long history and growing interest in isotopic analyses of N2 O, there is a lack of isotopically characterized N2 O isotopic reference materials (standards) to enable normalization and reporting of isotope-delta values. Here we report the isotopic characterization of two pure N2 O gas reference materials, USGS51 and USGS52, which are now available for laboratory calibration (https://isotopes.usgs.gov/lab/referencematerials.html). METHODS: A total of 400 sealed borosilicate glass tubes of each N2 O reference gas were prepared from a single gas filling of a high vacuum line. We demonstrated isotopic homogeneity via dual-inlet isotope-ratio mass spectrometry. Isotopic analyses of these reference materials were obtained from eight laboratories to evaluate interlaboratory variation and provide preliminary isotopic characterization of their δ15 N, δ18 O, δ15 Nα , δ15 Nß and site preference (SP ) values. RESULTS: The isotopic homogeneity of both USGS51 and USGS52 was demonstrated by one-sigma standard deviations associated with the determinations of their δ15 N, δ18 O, δ15 Nα , δ15 Nß and SP values of 0.12 mUr or better. The one-sigma standard deviations of SP measurements of USGS51 and USGS52 reported by eight laboratories participating in the interlaboratory comparison were 1.27 and 1.78 mUr, respectively. CONCLUSIONS: The agreement of isotope-delta values obtained in the interlaboratory comparison was not sufficient to provide reliable accurate isotope measurement values for USGS51 and USGS52. We propose that provisional values for the isotopic composition of USGS51 and USGS52 determined at the Tokyo Institute of Technology can be adopted for normalizing and reporting sample data until further refinements are achieved through additional calibration efforts.

10.
Rapid Commun Mass Spectrom ; 31(6): 475-484, 2017 Mar 30.
Article in English | MEDLINE | ID: mdl-27984667

ABSTRACT

RATIONALE: Accurate hydrogen isotopic analysis of halogen- and sulfur-bearing organics has not been possible with traditional high-temperature conversion (HTC) because the formation of hydrogen-bearing reaction products other than molecular hydrogen (H2 ) is responsible for non-quantitative H2 yields and possible hydrogen isotopic fractionation. Our previously introduced, new chromium-based EA-Cr/HTC-IRMS (Elemental Analyzer-Chromium/High-Temperature Conversion Isotope Ratio Mass Spectrometry) technique focused primarily on nitrogen-bearing compounds. Several technical and analytical issues concerning halogen- and sulfur-bearing samples, however, remained unresolved and required further refinement of the reactor systems. METHODS: The EA-Cr/HTC reactor was substantially modified for the conversion of halogen- and sulfur-bearing samples. The performance of the novel conversion setup for solid and liquid samples was monitored and optimized using a simultaneously operating dual-detection system of IRMS and ion trap MS. The method with several variants in the reactor, including the addition of manganese metal chips, was evaluated in three laboratories using EA-Cr/HTC-IRMS (on-line method) and compared with traditional uranium-reduction-based conversion combined with manual dual-inlet IRMS analysis (off-line method) in one laboratory. RESULTS: The modified EA-Cr/HTC reactor setup showed an overall H2 -recovery of more than 96% for all halogen- and sulfur-bearing organic compounds. All results were successfully normalized via two-point calibration with VSMOW-SLAP reference waters. Precise and accurate hydrogen isotopic analysis was achieved for a variety of organics containing F-, Cl-, Br-, I-, and S-bearing heteroelements. The robust nature of the on-line EA-Cr/HTC technique was demonstrated by a series of 196 consecutive measurements with a single reactor filling. CONCLUSIONS: The optimized EA-Cr/HTC reactor design can be implemented in existing analytical equipment using commercially available material and is universally applicable for both heteroelement-bearing and heteroelement-free organic-compound classes. The sensitivity and simplicity of the on-line EA-Cr/HTC-IRMS technique provide a much needed tool for routine hydrogen-isotope source tracing of organic contaminants in the environment. Copyright © 2016 John Wiley & Sons, Ltd.

11.
Science ; 354(6310): 296, 2016 10 21.
Article in English | MEDLINE | ID: mdl-27846528

ABSTRACT

Moseley et al's (Reports, 8 January 2016, p. 165) preferred-Termination-II age is subjective, as evidenced by variation in their Termination-II ages of 2500 years per meter. Termination-II-age bias decreases to zero at ~1.5 meters below the present-day water table, if one assumes linear variation with core-sample height. Maintaining the required gradient of thorium isotope 230Th over 3.6 meters for 1000 years, much less 10,000 years, seems exceedingly unlikely.


Subject(s)
Climate , Thorium
12.
Forensic Sci Int ; 266: 222-225, 2016 09.
Article in English | MEDLINE | ID: mdl-27344261

ABSTRACT

The hydrogen isotopic composition (δ(2)HVSMOW-SLAP) of USGS42 and USGS43 human hair stable isotopic reference materials, normalized to the VSMOW (Vienna-Standard Mean Ocean Water)-SLAP (Standard Light Antarctic Precipitation) scale, was originally determined with a high temperature conversion technique using an elemental analyzer (TC/EA) with a glassy carbon tube and glassy carbon filling and analysis by isotope-ratio mass spectrometer (IRMS). However, the TC/EA IRMS method can produce inaccurate δ(2)HVSMOW-SLAP results when analyzing nitrogen-bearing organic substances owing to the formation of hydrogen cyanide (HCN), leading to non-quantitative conversion of a sample into molecular hydrogen (H2) for IRMS analysis. A single-oven, chromium-filled, elemental analyzer (Cr-EA) coupled to an IRMS substantially improves the measurement quality and reliability of hydrogen isotopic analysis of hydrogen- and nitrogen-bearing organic material because hot chromium scavenges all reactive elements except hydrogen. USGS42 and USGS43 human hair isotopic reference materials have been analyzed with the Cr-EA IRMS method, and the δ(2)HVSMOW-SLAP values of their non-exchangeable hydrogen fractions have been revised: [Formula: see text] [Formula: see text] where mUr=0.001=‰. On average, these revised δ(2)HVSMOW-SLAP values are 5.7mUr more positive than those previously measured. It is critical that readers pay attention to the δ(2)HVSMOW-SLAP of isotopic reference materials in publications as they may need to adjust the δ(2)HVSMOW-SLAP measurement results of human hair in previous publications to ensure all results are on the same isotope-delta scale.


Subject(s)
Forensic Sciences/standards , Hair/chemistry , Hydrogen/chemistry , Humans , Isotopes/analysis , Isotopes/chemistry , Isotopes/standards , Reference Standards , Reproducibility of Results
13.
Anal Chem ; 88(8): 4294-302, 2016 Apr 19.
Article in English | MEDLINE | ID: mdl-26974360

ABSTRACT

An international project developed, quality-tested, and determined isotope-δ values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-600 (caffeine). These new RMs enable users to normalize measurements of samples to isotope-δ scales. The RMs span a range of δ(2)H(VSMOW-SLAP) values from -210.8 to +397.0 mUr or ‰, for δ(13)C(VPDB-LSVEC) from -40.81 to +0.49 mUr and for δ(15)N(Air) from -5.21 to +61.53 mUr. Many of the new RMs are amenable to gas and liquid chromatography. The RMs include triads of isotopically contrasting caffeines, C16 n-alkanes, n-C20-fatty acid methyl esters (FAMEs), glycines, and l-valines, together with polyethylene powder and string, one n-C17-FAME, a vacuum oil (NBS 22a) to replace NBS 22 oil, and a (2)H-enriched vacuum oil. A total of 11 laboratories from 7 countries used multiple analytical approaches and instrumentation for 2-point isotopic normalization against international primary measurement standards. The use of reference waters in silver tubes allowed direct normalization of δ(2)H values of organic materials against isotopic reference waters following the principle of identical treatment. Bayesian statistical analysis yielded the mean values reported here. New RMs are numbered from USGS61 through USGS78, in addition to NBS 22a. Because of exchangeable hydrogen, amino acid RMs currently are recommended only for carbon- and nitrogen-isotope measurements. Some amino acids contain (13)C and carbon-bound organic (2)H-enrichments at different molecular sites to provide RMs for potential site-specific isotopic analysis in future studies.

14.
Rapid Commun Mass Spectrom ; 30(7): 859-66, 2016 Apr 15.
Article in English | MEDLINE | ID: mdl-26969927

ABSTRACT

RATIONALE: The widely used l-glutamic acid isotopic reference material USGS41, enriched in both (13) C and (15) N, is nearly exhausted. A new material, USGS41a, has been prepared as a replacement for USGS41. METHODS: USGS41a was prepared by dissolving analytical grade l-glutamic acid enriched in (13) C and (15) N together with l-glutamic acid of normal isotopic composition. The δ(13) C and δ(15) N values of USGS41a were directly or indirectly normalized with the international reference materials NBS 19 calcium carbonate (δ(13) CVPDB = +1.95 mUr, where milliurey = 0.001 = 1 ‰), LSVEC lithium carbonate (δ(13) CVPDB = -46.6 mUr), and IAEA-N-1 ammonium sulfate (δ(15) NAir = +0.43 mUr) and USGS32 potassium nitrate (δ(15) N = +180 mUr exactly) by on-line combustion, continuous-flow isotope-ratio mass spectrometry, and off-line dual-inlet isotope-ratio mass spectrometry. RESULTS: USGS41a is isotopically homogeneous; the reproducibility of δ(13) C and δ(15) N is better than 0.07 mUr and 0.09 mUr, respectively, in 200-µg amounts. It has a δ(13) C value of +36.55 mUr relative to VPDB and a δ(15) N value of +47.55 mUr relative to N2 in air. USGS41 was found to be hydroscopic, probably due to the presence of pyroglutamic acid. Experimental results indicate that the chemical purity of USGS41a is substantially better than that of USGS41. CONCLUSIONS: The new isotopic reference material USGS41a can be used with USGS40 (having a δ(13) CVPDB value of -26.39 mUr and a δ(15) NAir value of -4.52 mUr) for (i) analyzing local laboratory isotopic reference materials, and (ii) quantifying drift with time, mass-dependent isotopic fractionation, and isotope-ratio-scale contraction for isotopic analysis of biological and organic materials. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.


Subject(s)
Carbon Isotopes/analysis , Glutamic Acid/analysis , Glutamic Acid/chemistry , Mass Spectrometry/standards , Nitrogen Isotopes/analysis , Carbon Isotopes/chemistry , Nitrogen Isotopes/chemistry , Reference Standards , Reproducibility of Results
15.
Rapid Commun Mass Spectrom ; 29(21): 2078-82, 2015 Nov 15.
Article in English | MEDLINE | ID: mdl-26443409

ABSTRACT

RATIONALE: As a result of the need for isotopic reference waters having high δ(2) HVSMOW-SLAP and δ(18) OVSMOW-SLAP values for daily use, especially for tropical and equatorial-zone freshwaters, a new secondary isotopic reference material for international distribution was prepared from water collected from Lake Kyoga, Uganda. METHODS: This isotopic reference lakewater was filtered through a membrane with 0.2-µm pore size, homogenized, loaded into glass ampoules that were sealed with a torch and autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available in a case of 144 glass ampoules each containing 5 mL of water. RESULTS: The δ(2) H and δ(18) O values of this reference material are +32.8 ± 0.4 and +4.95 ± 0.02 mUr (milliurey = 0.001 = 1 ‰), respectively, relative to VSMOW, on scales normalized such that the δ(2) H and δ(18) O values of SLAP reference water are, respectively, -428 and -55.5 mUr. Each uncertainty is an estimated expanded uncertainty (U = 2uc ) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. CONCLUSIONS: This isotopic reference material, designated as USGS50, is intended as one of two reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer, of use especially for isotope-hydrology laboratories analyzing freshwater samples from equatorial and tropical regions.

16.
Rapid Commun Mass Spectrom ; 29(22): 2122-30, 2015 Nov 30.
Article in English | MEDLINE | ID: mdl-26467224

ABSTRACT

RATIONALE: Although laser absorption spectrometry (LAS) instrumentation is easy to use, its incorporation into laboratory operations is not easy, owing to extensive offline manipulation of comma-separated-values files for outlier detection, between-sample memory correction, nonlinearity (δ-variation with water amount) correction, drift correction, normalization to VSMOW-SLAP scales, and difficulty in performing long-term QA/QC audits. METHODS: A Microsoft Access relational-database application, LIMS (Laboratory Information Management System) for Lasers 2015, was developed. It automates LAS data corrections and manages clients, projects, samples, instrument-sample lists, and triple-isotope (δ(17)O, δ(18)O, and δ(2)H values) instrumental data for liquid-water samples. It enables users to (1) graphically evaluate sample injections for variable water yields and high isotope-delta variance; (2) correct for between-sample carryover, instrumental drift, and δ nonlinearity; and (3) normalize final results to VSMOW-SLAP scales. RESULTS: Cost-free LIMS for Lasers 2015 enables users to obtain improved δ(17)O, δ(18)O, and δ(2)H values with liquid-water LAS instruments, even those with under-performing syringes. For example, LAS δ(2) HVSMOW measurements of USGS50 Lake Kyoga (Uganda) water using an under-performing syringe having ±10 % variation in water concentration gave +31.7 ± 1.6 ‰ (2-σ standard deviation), compared with the reference value of +32.8 ± 0.4 ‰, after correction for variation in δ value with water concentration, between-sample memory, and normalization to the VSMOW-SLAP scale. CONCLUSIONS: LIMS for Lasers 2015 enables users to create systematic, well-founded instrument templates, import δ(2) H, δ(17) O, and δ(18) O results, evaluate performance with automatic graphical plots, correct for δ nonlinearity due to variable water concentration, correct for between-sample memory, adjust for drift, perform VSMOW-SLAP normalization, and perform long-term QA/QC audits easily.

17.
Rapid Commun Mass Spectrom ; 29(9): 878-84, 2015 May 15.
Article in English | MEDLINE | ID: mdl-26377016

ABSTRACT

RATIONALE: High-precision hydrogen isotope ratio analysis of nitrogen-bearing organic materials using high-temperature conversion (HTC) techniques has proven troublesome in the past. Formation of reaction products other than molecular hydrogen (H(2)) has been suspected as a possible cause of incomplete H(2) yield and hydrogen isotopic fractionation. METHODS: The classical HTC reactor setup and a modified version including elemental chromium, both operated at temperatures in excess of 1400 °C, have been compared using a selection of nitrogen-bearing organic compounds, including caffeine. A focus of the experiments was to avoid or suppress hydrogen cyanide (HCN) formation and to reach quantitative H(2) yields. The technique also was optimized to provide acceptable sample throughput. RESULTS: The classical HTC reaction of a number of selected compounds exhibited H(2) yields from 60 to 90 %. Yields close to 100 % were measured for the experiments with the chromium-enhanced reactor. The δ(2)H values also were substantially different between the two types of experiments. For the majority of the compounds studied, a highly significant relationship was observed between the amount of missing H(2) and the number of nitrogen atoms in the molecules, suggesting the pyrolytic formation of HCN as a byproduct. A similar linear relationship was found between the amount of missing H(2) and the observed hydrogen isotopic result, reflecting isotopic fractionation. CONCLUSIONS: The classical HTC technique to produce H(2) from organic materials using high temperatures in the presence of glassy carbon is not suitable for nitrogen-bearing compounds. Adding chromium to the reaction zone improves the yield to 100 % in most cases. The initial formation of HCN is accompanied by a strong hydrogen isotope effect, with the observed hydrogen isotope results on H(2) being substantially shifted to more negative δ(2)H values. The reaction can be understood as an initial disproportionation leading to H(2) and HCN with the HCN-hydrogen systematically enriched in (2)H by more than 50 ‰. In the reaction of HCN with chromium, H(2) and chromium-containing solid residues are formed quantitatively.


Subject(s)
Hydrogen/chemistry , Nitrogen Compounds/analysis , Nitrogen Compounds/chemistry , Hot Temperature , Hydrogen/analysis , Hydrogen Cyanide/chemistry , Mass Spectrometry
19.
Anal Chem ; 87(10): 5198-205, 2015.
Article in English | MEDLINE | ID: mdl-25874646

ABSTRACT

The high temperature conversion (HTC) technique using an elemental analyzer with a glassy carbon tube and filling (temperature conversion/elemental analysis, TC/EA) is a widely used method for hydrogen isotopic analysis of water and many solid and liquid organic samples with analysis by isotope-ratio mass spectrometry (IRMS). However, the TC/EA IRMS method may produce inaccurate δ(2)H results, with values deviating by more than 20 mUr (milliurey = 0.001 = 1‰) from the true value for some materials. We show that a single-oven, chromium-filled elemental analyzer coupled to an IRMS substantially improves the measurement quality and reliability for hydrogen isotopic compositions of organic substances (Cr-EA method). Hot chromium maximizes the yield of molecular hydrogen in a helium carrier gas by irreversibly and quantitatively scavenging all reactive elements except hydrogen. In contrast, under TC/EA conditions, heteroelements like nitrogen or chlorine (and other halogens) can form hydrogen cyanide (HCN) or hydrogen chloride (HCl) and this can cause isotopic fractionation. The Cr-EA technique thus expands the analytical possibilities for on-line hydrogen-isotope measurements of organic samples significantly. This method yielded reproducibility values (1-sigma) for δ(2)H measurements on water and caffeine samples of better than 1.0 and 0.5 mUr, respectively. To overcome handling problems with water as the principal calibration anchor for hydrogen isotopic measurements, we have employed an effective and simple strategy using reference waters or other liquids sealed in silver-tube segments. These crimped silver tubes can be employed in both the Cr-EA and TC/EA techniques. They simplify considerably the normalization of hydrogen-isotope measurement data to the VSMOW-SLAP (Vienna Standard Mean Ocean Water-Standard Light Antarctic Precipitation) scale, and their use improves accuracy of the data by eliminating evaporative loss and associated isotopic fractionation while handling water as a bulk sample. The calibration of organic samples, commonly having high δ(2)H values, will benefit from the availability of suitably (2)H-enriched reference waters, extending the VSMOW-SLAP scale above zero.


Subject(s)
Chemistry Techniques, Analytical/methods , Chromium/chemistry , Hydrogen/chemistry , Organic Chemicals/chemistry , Temperature , Calibration , Diffusion , Halogens/chemistry , Isotopes
20.
Rapid Commun Mass Spectrom ; 28(19): 2031-4, 2014 Oct 15.
Article in English | MEDLINE | ID: mdl-25156591

ABSTRACT

RATIONALE: As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from drinking water collected from the Biscayne aquifer in Ft. Lauderdale, Florida. METHODS: This isotopic reference water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available by the case of 144 glass ampoules containing either 4 mL or 5 mL of water in each ampoule. RESULTS: The δ(2)H and δ(18)O values of this reference material are -10.3 ± 0.4‰ and -2.238 ± 0.011‰, respectively, relative to VSMOW, on scales normalized such that the δ(2)H and δ(18)O values of SLAP reference water are, respectively, -428 and -55.5‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc ) about the reference value that provides an interval that has about a 95% probability of encompassing the true value. CONCLUSIONS: This isotopic reference material, designated as USGS45, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.

SELECTION OF CITATIONS
SEARCH DETAIL
...