Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
J Cardiothorac Surg ; 18(1): 340, 2023 Nov 22.
Article in English | MEDLINE | ID: mdl-37993865

ABSTRACT

BACKGROUND: Acute type A aortic dissection is associated with high perioperative morbidity and mortality. Ascyrus Medical Dissection Stent (Cryolife, Kennesaw, USA) is a novel uncovered hybrid stent graft developed to be used as an adjunct to standard surgical approach to promote true lumen expansion and enhance aortic remodeling. METHODS: From March 2021 to March 2022, four consecutive patients presented with acute Debakey type I aortic dissection and underwent emergent surgical repair with Tirone David procedure and implantation of Ascyrus Medical Dissection Stent. We reviewed patient's files retrospectively and described the perioperative outcomes. RESULTS: All four device implantations were successful. Overall 30-day mortality was 0%. Malperfusion that was present in two patients pre-operatively improved after Ascyrus Medical Dissection Stent implantation. No aortic reinterventions were needed. No aortic injury related to the device was noted. Favourable changes in aortic true lumen and false lumen dimensions were found in most of our patients but the stent was compressed at the isthmus in one patient. CONCLUSION: Ascyrus Medical Dissection Stent is a reliable and secure device. However, its benefits remain unclear when it comes to a positive remodeling and seems less likelihood comparable to a frozen elephant trunk. The main reason seems to be an insufficient radial force of the stent.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/methods , Postoperative Complications/surgery , Retrospective Studies , Stents , Treatment Outcome
2.
J Cardiothorac Surg ; 18(1): 344, 2023 Nov 27.
Article in English | MEDLINE | ID: mdl-38012735

ABSTRACT

We present the case of a 63-year-old woman who was hospitalized five times in 4 months for episodes of heart failure, associated with a sustained hypertension despite a fivefold therapy. The pathophysiological mechanism of the hypertension was a secondary hyperaldosteronism linked to a renal hypoperfusion due to the narrowing of the thoracic aorta by a huge calcified plaque, mimicking an aortic coarctation.


Subject(s)
Aortic Coarctation , Heart Failure , Hypertension , Female , Humans , Middle Aged , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortic Coarctation/diagnosis , Aortic Coarctation/diagnostic imaging , Heart Failure/complications , Hypertension/complications , Kidney
3.
J Cardiovasc Surg (Torino) ; 64(2): 224-229, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36756900

ABSTRACT

BACKGROUND: Ventricular septal rupture (VSR) is an uncommon but life-threatening complication of acute myocardial infarction. Extra corporeal life support (ECLS) use in the preoperative setting allows hemodynamic stabilization for a delayed surgery. We aimed to assess the role of ECLS in the preoperative period of post infarction VSR surgery. METHODS: We retrospectively analyzed all consecutive patients operated for VSR between January 2007 and August 2019. We assessed baseline characteristics, pre and post-operative clinical status and the use of ECLS in the peri-operative period. RESULTS: A total of 39 patients were included. Mean age was 69.8 years. In-hospital mortality was 48.7%. Survivors and non-survivor patients had similar characteristics except for lower postoperative ejection fraction (32% vs. 42%, P=0.02) and more acute renal failure (71.4% vs. 10%, P=0.0005) in the non-survivor group. Patients who received ECLS preoperatively were younger (72 vs. 65, P=0.02) and had more preoperative invasive ventilation (16% vs. 50%, P=0.04). Cardiopulmonary bypass (CPB, 140 min vs. 75 min, P=0.0008) and cross clamping times (94 min vs. 52 min, P=0.0026) were significantly higher in the ECLS group. There were more bleeding complications in the ECMO group (45.4% vs. 0%, P=0.0019) and more need for reintervention (63.3% vs. 13%, P=0.015). There was no difference in mortality between the two groups. There was no difference in postoperative characteristics between urgent and delayed surgery. CONCLUSIONS: In our study, post-operative ECLS use was associated with more bleeding complications and need for reintervention. Although mortality was similar, bleeding complications remain a major limitation for the systematic use of ECLS in the post-operative period.


Subject(s)
Extracorporeal Membrane Oxygenation , Myocardial Infarction , Ventricular Septal Rupture , Humans , Aged , Extracorporeal Membrane Oxygenation/adverse effects , Retrospective Studies , Ventricular Septal Rupture/diagnostic imaging , Ventricular Septal Rupture/etiology , Ventricular Septal Rupture/surgery , Treatment Outcome , Myocardial Infarction/complications
4.
Diagn Interv Imaging ; 104(5): 235-242, 2023 May.
Article in English | MEDLINE | ID: mdl-36646587

ABSTRACT

PURPOSE: The purpose of this study was to investigate the feasibility of identifying and characterizing the three most common types of endoleaks within a thoracic aorta aneurysm model using bicolor K-edge imaging with a spectral photon-counting computing tomography (SPCCT) system in combination with a biphasic contrast agent injection. MATERIALS AND METHODS: Three types of thoracic endoleaks (type 1, 2 and 3) were created in a dynamic anthropomorphic thoracic aorta phantom. Protocol consisted in an injection of an iodinated contrast material followed 80 seconds after an injection of a gadolinium-based contrast agent (GBCA). The phantom was scanned using a clinical prototype SPCCT during bicolor phase imaging consisting in an early distribution of GBCA and a late distribution of iodine. Conventional and spectral images were reconstructed for differentiating between the contrast agents and measuring their respective attenuation values and concentrations inside and outside the stent graft. RESULTS: Conventional images failed to provide specific dynamic imaging contrast agents in the aneurysmal sac and outside the stent graft while spectral images differentiated their specific distribution. In type 1 and 3 thoracic endoleaks, GBCA concentration was measured outside the stent graft at 6.1 ± 3.7 (standard deviation [SD]) mg/mL and 6.0 ± 4.0 (SD) mg/mL, respectively, in favor of an early blood flow. In type 2 thoracic endoleak, iodine was measured outside the stent graft at 24.3 ± 5.5 (SD) mg/mL in favor of a late blood flow in the aneurysmal sac. CONCLUSION: Bicolor K-edge imaging enabled SPCCT allows a bicolor characterization of thoracic aorta endoleaks in a single acquisition in combination with a biphasic contrast agent injection.


Subject(s)
Contrast Media , Iodine , Humans , Endoleak/diagnostic imaging , Tomography, X-Ray Computed/methods , Phantoms, Imaging
5.
Eur Heart J Open ; 2(3): oeac029, 2022 May.
Article in English | MEDLINE | ID: mdl-35919341

ABSTRACT

Aims: After transcatheter aortic valve replacement (TAVR), cardiovascular and non-cardiovascular comorbidities may offset the survival benefit from the procedure. We aimed to describe the relationships between that benefit and patient comorbidities. Methods and results: The study pooled two European cohorts of patients with severe aortic stenosis (AS-pooled): one with patients who underwent (cohort of AS patients treated by TAVR, N = 233) and another with patients who did not undergo TAVR (cohort of AS patients treated medically; N = 291). The investigators collected the following: calcification prognostic impact (CAPRI) and Charlson scores for cardiovascular and non-cardiovascular comorbidities, activities of daily living (ADL)/instrumental activities of daily living (IADL) scores for frailty as well as routine Society of Thoracic Surgeons (STS) score and Logistic Euroscore. Unlike ADL/IADL scores, CAPRI and Charlson scores were found to be independent predictors of 1-year all-cause death in the AS-pooled cohort, with and without adjustment for STS score or Logistic Euroscore; they were thus retained to define a three-level prognostic scale (good, intermediate, and poor). The survival benefit from TAVR-vs. no TAVR-was stratified according to these three prognosis categories. The beneficial effect of TAVR on 1-year all-cause death was significant in patients with good and intermediate prognosis, hazard ratio (95% confidence interval): 0.36 (0.18; 0.72) and 0.32 (0.15; 0.67). That effect was reduced and not statistically significant in patient with poor prognosis [0.65 (0.22; 1.88)]. Conclusion: The study showed that, beyond a given comorbidity burden (as assessed by CAPRI and Charlson scores), the probability of death within a year was high and poorly reduced by TAVR. This indicates the futility of TAVR in patients in the poor prognosis category.

6.
Front Cardiovasc Med ; 9: 873144, 2022.
Article in English | MEDLINE | ID: mdl-35694668

ABSTRACT

Objective: The standard treatment for complicated Stanford type B aortic dissection (TBAD) is thoracic endovascular aortic repair (TEVAR). Functional parameters, specifically blood flow, are not measured in the clinical assessment of TEVAR, yet they are of outmost importance in patient outcome. Consequently, we investigated the impact of TEVAR on the flows in the aorta and its branches in TBAD using 4D Phase-Contrast Magnetic Resonance Imaging (4D Flow MRI). Methods: Seven patients with TBAD scheduled for TEVAR underwent pre and post-operative 4D Flow MRI. An experienced reader assessed the presence of helical flow in the false lumen (FL) using streamlines and measured net flow at specific locations. In addition, forward and reverse flows, stasis, helicity, and absolute helicity were computed automatically along the aorta centerline. Average values were then computed in the segmented vessels. Impact of TEVAR on these parameters was assessed with a Wilcoxon signed rank test. Impact of the metallic stent on the velocity quantification was assessed using intra-class correlation coefficient (ICC) between velocities measured intra-stent and in adjacent stent-free regions. Results: FL helical flow was observed proximally in 6 cases and distally in 2 cases pre-operatively. Helical flow disappeared post-TEVAR proximally, but developed distally for 2 patients. Intra-stent measures were similar to stent-free with a median difference of 0.1 L/min and an ICC equal to 0.967 (p < 0.01). Forward flow increased from 59.9 to 81.6% in the TL and significantly decreased in the FL from 15.9 to 3.3%. Similarly, reverse flow increased in the TL from 4.36 to 10.8% and decreased in the FL from 10.3 to 4.6%. No significant changes were observed in net flow for aortic branches (p > 0.05). A significant increase in FL stasis was observed (p = 0.04). Discussion: TEVAR significantly increased forward flow in the TL and significantly decreased both forward and reverse flows in the FL. Interestingly, reverse flow in the TL increased post-TEVAR, which could be due to increased rigidity of the wall, due to the metallic stent. User independent helicity quantification enabled detection of elevated helicity at the level of secondary entry tears which had been missed by streamline visualization.

7.
J Thorac Dis ; 8(3): E232-4, 2016 Mar.
Article in English | MEDLINE | ID: mdl-27076977

ABSTRACT

Laubry-Pezzi syndrome is a rare congenital heart disease (CHD) combining a ventricular septal defect (VSD) and an aortic regurgitation (AR) due to a prolapse of the right coronary or, less frequently, non-coronary cusp. In the literature there are very few reports of long-term complications after surgical correction of this syndrome. We present the late occurrence of an aortic root pseudoaneurysm and a residual VSD in a patient with Laubry-Pezzi syndrome operated during childhood.

SELECTION OF CITATIONS
SEARCH DETAIL
...