Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-36197419

ABSTRACT

We described a MRSA bloodstream infection outbreak that was rapidly identified and controlled in a Neonatal Intensive Care Unit after implementation of a bundle of measures, including PCR-screening and HCW decolonization. We found 35% of healthcare workers(HCW) colonized with S. aureus by PCR, one of them that presented skin lesion positive for MSSA (same clone and spa type than two patients). Our findings raise the hypothesis that the outbreak could be related to HCW colonization.


Subject(s)
Cross Infection , Methicillin-Resistant Staphylococcus aureus , Staphylococcal Infections , Cross Infection/diagnosis , Cross Infection/epidemiology , Cross Infection/prevention & control , Developed Countries , Disease Outbreaks/prevention & control , Humans , Infant, Newborn , Infection Control , Intensive Care Units, Neonatal , Methicillin-Resistant Staphylococcus aureus/genetics , Staphylococcal Infections/diagnosis , Staphylococcal Infections/epidemiology , Staphylococcus aureus
2.
Article in English | LILACS-Express | LILACS | ID: biblio-1406887

ABSTRACT

ABSTRACT We described a MRSA bloodstream infection outbreak that was rapidly identified and controlled in a Neonatal Intensive Care Unit after implementation of a bundle of measures, including PCR-screening and HCW decolonization. We found 35% of healthcare workers(HCW) colonized with S. aureus by PCR, one of them that presented skin lesion positive for MSSA (same clone and spa type than two patients). Our findings raise the hypothesis that the outbreak could be related to HCW colonization.

3.
Am J Infect Control ; 49(4): 512-515, 2021 04.
Article in English | MEDLINE | ID: mdl-33080363

ABSTRACT

This study assessed the disinfection using 70% ethanol; H2O2-quaternary ammonium salt mixture; 0.1% sodium hypochlorite and autoclaving of four 3D-printed face shields with different designs, visor materials; and visor thickness (0.5-0.75 mm). We also investigated their clinical suitability by applying a questionnaire to health workers (HW) who used them. Each type of disinfection was done 40 times on each type of mask without physical damage. In contrast, autoclaving led to appreciable damage.


Subject(s)
COVID-19/prevention & control , Disinfectants/pharmacology , Disinfection/methods , Personal Protective Equipment/virology , Printing, Three-Dimensional , SARS-CoV-2 , COVID-19/epidemiology , Data Collection , Equipment Design , Ethanol/pharmacology , Health Personnel , Humans , Hydrogen Peroxide/pharmacology , Sodium Hypochlorite/pharmacology
SELECTION OF CITATIONS
SEARCH DETAIL