Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 26
Filter
1.
Diagnostics (Basel) ; 13(10)2023 May 16.
Article in English | MEDLINE | ID: mdl-37238242

ABSTRACT

(1) Background: We aim to present our experience with resection of the inferior vena cava (IVC) without reconstruction in two patients diagnosed with renal tumors. (2) Case Report: The first case was diagnosed with right renal vein sarcoma and the second case was diagnosed with clear cell renal carcinoma; both presented signs of invasion and thrombosis of the IVC at infrarenal and cruoric levels, along with the development of collateral circulation with the help of the paravertebral plexus. In both patients, en bloc right nephrectomy was performed along with the resection of the thrombosed IVC without further reconstruction. In the case of the patient with right vein sarcoma, preservation of the left renal and caval intrahepatic vein was possible, whilst in the second case diagnosed with clear cell renal carcinoma, the associated left renal thrombosis also enforced the resection of the left renal vein. (3) Discussion: Postoperative evolution was favorable in both cases and did not exhibit major complications. Antibiotic therapy, analgesics, and anticoagulant medication were administered at therapeutic doses after surgery in both cases. The histopathological examination of the surgical specimen confirmed the diagnoses of renal vein sarcoma in the first case and clear cell renal carcinoma in the second case. Surgical treatment and adjuvant chemotherapy prolonged survival for two years for the first case and for two months, up until this moment, for the second case. The survival of clear cell renal carcinoma is currently at two months. (4) Conclusions: The resection of the inferior vena cava, without subsequent reconstruction in cases presenting diffused distal thrombosis, can represent an alternative to IVC reconstruction, which might lead to a major ulterior risk of thrombosis. In some cases, this can result in long-term survival.

2.
Exp Ther Med ; 24(5): 697, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36277161

ABSTRACT

Cardiac lipomas are generally asymptomatic even in large dimensions. Echocardiograms can identify tumors, but cardiac magnetic resonance imaging or cardiac computerized tomography can differentiate cardiac lipomas from other cardiac tumors. The present study is a case report of an asymptomatic 30-year-old man diagnosed with atrial lipoma. The patient received cardiac surgery and the intervention consisted of exclusion of the right atrial (RA) tumor and reconstruction of the right atrium with 'XenoSure' patch in extracorporeal circulation through a minimally invasive approach. A short PubMed literature review was performed and 26 cases of RA lipomas with available details were found. Cardiac tumors may cause clinical presentation through different pathways. Symptoms related to an RA lipoma were present in 21 out of 26 patients (80%). The symptoms varied greatly, dyspnea being the most common of them. In one case, the lipoma was found during the autopsy of a patient after sudden death. Large cardiac lipomas can lead to complications such as obstruction of ventricular outflow tract, electric disorders, embolism or pericardial effusion. Obstruction of the right ventricular outflow tract was reported in 11 out of 26 patients (42%) diagnosed with RA lipoma. Generally, atrial lipoma can have various sizes. The most useful imaging technique was transthoracic echocardiography. Accurate diagnosis and evaluation of cardiac lipoma is dependent on multimodality imaging methods, including cardiac magnetic resonance. Surgery is the treatment of choice, but the risk-benefit ratio must be considered, and shared decision making must be taken into account. The present review data showed that 23 out of 25 patients (92%) underwent surgery. Among these patients, only 1 out of 23 received a minimally invasive approach in 2021. Cardiac lipomas are rare entities, usually asymptomatic, that can occur at any age. The most useful diagnostic method of cardiac tumors is echocardiography, but nuclear magnetic resonance can also specify the type and characteristics of tumors.

3.
Polymers (Basel) ; 14(6)2022 Mar 16.
Article in English | MEDLINE | ID: mdl-35335519

ABSTRACT

Intraoperative haemostasis is of paramount importance in the practice of cardiovascular surgery. Over the past 70 years, topical haemostatic methods have advanced significantly and today we deal with various haemostatic agents with different properties and different mechanisms of action. The particularity of coagulation mechanisms after extracorporeal circulation, has encouraged the introduction of new types of topic agents to achieve haemostasis, where conventional methods prove their limits. These products have an important role in cardiac, as well as in vascular, surgery, mainly in major vascular procedures, like aortic dissections and aortic aneurysms. This article presents those agents used for topical application and the mechanism of haemostasis and offers general recommendations for their use in the operating room.

4.
Healthcare (Basel) ; 10(1)2022 Jan 14.
Article in English | MEDLINE | ID: mdl-35052321

ABSTRACT

Chondrosarcomas represent approximately 20% of primary malignant bone cancers, being known as the most frequent neoplasia of the anterior thoracic wall. In our case, we present a case of a primary sternal chondrosarcoma in a 50-year-old female patient that has been polychemiotherapy and radiotherapy treated for breast cancer. Despite the initial treated malignancy of breast cancer in the personal pathologic history of the patient, it was discovered that the sternal tumor was not a metastatic disease from the breast neoplasm. After multiple investigations, the patient was successfully treated for the sternal chondrosarcoma after a radical sternal resection with a chest wall reconstruction completed with two titanium plates that were anchored on the ribs and with the placement of methyl methacrylate mesh.

5.
Medicina (Kaunas) ; 57(9)2021 Sep 18.
Article in English | MEDLINE | ID: mdl-34577907

ABSTRACT

The atrial septal defect is, after bicuspid aortic valve disease, the most common congenital cardiac disease present in the adult population. The most common atrial septal defects are the ostium secundum type (75-80%), followed by the ostium primum type (15%). The sinus venosus atrial septal defects (SV-ASD), defined as a communication in the posterior part of the interatrial septum, account for about 5 to 10% of atrial septal defects. Approximately 90% of SV-ASDs are associated with partial anomalous pulmonary venous drainage (PAPVD). The minimally invasive approach has gained ground in the treatment of ASDs, especially those of the ostium secundum type. The sinus venosus type is a relatively uncommon form of ASD, which, when associated with a PAPVD, is considered a complex cardiac malformation, and is usually treated in a classical manner, through median sternotomy. We describe the case of a 45-year-old woman diagnosed in adolescence with SV-ASD with PAPVD, who successfully underwent minimally invasive repair with fresh autologous pericardial patch reconstruction through an anterolateral mini-thoracotomy incision. The patient presented with shortness of breath and fatigue after heavy exertions, episodes of paroxysmal nocturnal dyspnea, palpitations during effort and at rest, and had a history of syncope dating from 17 years previously. Echocardiography revealed an SV-ASD with PAPVD in the right atrium and the intraoperative examination discovered that both right pulmonary veins were draining into the superior vena cava.


Subject(s)
Heart Septal Defects, Atrial , Pulmonary Veins , Adolescent , Adult , Drainage , Female , Heart Atria , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Humans , Middle Aged , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Vena Cava, Superior
6.
J Endovasc Ther ; 28(1): 20-31, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32873130

ABSTRACT

PURPOSE: To report a single-center series of patients with type B aortic dissection treated with the Multilayer Flow Modulator (MFM). MATERIALS AND METHODS: Over a 36-month period, 23 patients (median age 53 years; 20 men) with complicated type B aortic dissections (2 acute, 5 subacute, and 16 chronic) were treated with the MFM. Primary endpoints of rupture or dissection-related death, overall mortality, and reintervention were evaluated using the Kaplan-Meier method; estimates for freedom from the endpoints are reported with the 95% confidence interval (CI). Secondary outcomes included technical success, adverse events, and aortic remodeling. Clinical and imaging data were collected preoperatively, directly postoperatively, and annually to 36 months for analysis using computational fluid dynamics (CFD). RESULTS: Initial technical success was 91.3%. The estimates of the endpoints at 12 months were 100% for freedom from rupture or aortic-related death, 95.7% for freedom from overall mortality, and 91.3% for freedom from reintervention. No device-related neurological or systemic complications occurred, and no additional reinterventions were needed during follow-up. A total of 144 branches overstented by the MFM remained patent. Morphologic analysis of the aortic dissection showed progressive true lumen volume increase (75.9%, p<0.001) with concomitant false lumen volume decrease (42.8%, p<0.001); the CFD analyses showed increased laminar flow. CONCLUSION: In the current series, the MFM provided a safe and feasible treatment option for complicated acute, subacute, and chronic type B aortic dissections, with high technical success, low mortality, and active aortic remodeling. Further studies should elucidate the long-term safety of the MFM and its effectiveness in a larger patient cohort.


Subject(s)
Stents , Adult , Aged , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Female , Humans , Male , Middle Aged , Prosthesis Design , Stroke Volume , Time Factors , Treatment Outcome , Ventricular Function, Left
7.
Materials (Basel) ; 13(10)2020 May 15.
Article in English | MEDLINE | ID: mdl-32429089

ABSTRACT

Recently, multilayer stents for type B aortic dissections (TBAD) have been proposed to decrease false lumen flow, increase and streamline true lumen flow, and retain branch vessel patency. We aimed to provide a protocol with standardized techniques to investigate aortic remodeling of TBAD by multilayer flow modulators (MFM) in static geometric and hemodynamic analyses. Combining existing literature and new insights, a standardized protocol was designed. Using pre- and postoperative CT scans, geometric models were constructed, lumen dimensions were calculated, computational fluid dynamics (CFD) models were composed, and velocity and pressures were calculated. Sixteen TBAD cases treated with MFM were included for analysis. For each case, aortic remodeling was analyzed using post-processing medical imaging software. After 3D models were created, geometrical anatomical measurements were performed, and meshes for finite element analysis were generated. MFM cases were compared pre- and postoperatively; true lumen volumes increased (p < 0.001), false lumen volumes decreased (p = 0.001), true lumen diameter at the plane of maximum compression (PMC) increased (p < 0.001), and false lumen index decreased (p = 0.008). True lumen flow was streamlined, and the overall fluid velocity and pressures decreased (p < 0.001 and p = 0.006, respectively). This protocol provided a standardized method to evaluate the effects of MFM treatments in TBAD on geometric analyses, PMC, and CFD outcomes.

8.
Acta Biomater ; 96: 345-353, 2019 09 15.
Article in English | MEDLINE | ID: mdl-31306785

ABSTRACT

Abdominal aortic aneurysms (AAA) are common and potentially life-threatening aortic dilatations, due to the effect of hemodynamic changes on the aortic wall. Previous research has shown a potential pathophysiological role for increased macroscopic aneurysmal wall stiffness; however, not investigating micromechanical stiffness. We aimed to compile a new protocol to examine micromechanical live aortic stiffness (elastic moduli), correlated to histological findings with quantitative immunofluorescence (QIF). Live AAA biopsies (n = 7) and non-dilated aortas (controls; n = 3) were sectioned. Local elastic moduli of aortic intima, media and adventitia were analysed in the direction towards the lumen and vice versa with nanoindentation. Smooth muscle cells (SMC), collagen and fibroblasts were examined using QIF. Nanoindentation of AAA vs. controls demonstrated a 4-fold decrease in elastic moduli (p = 0.022) for layers combined and a 26-fold decrease (p = 0.017) for media-to-intima direction. QIF of AAA vs. controls revealed a 4-, 3- and 6-fold decrease of SMC, collagen and fibroblasts, respectively (p = 0.036). Correlations were found between bidirectional intima and media measurements (ρ = 0.661, p = 0.038) and all QIF analyses (ρ = 0.857-0.905, p = 0.002-0.007). We present a novel protocol to analyse microscopic elastic moduli in live aortic tissues using nanoindentation. Hence, our preliminary findings of decreased elastic moduli and altered wall composition warrant further microscopic stiffness investigation to potentially clarify AAA pathophysiology and to explore potential treatment by wall strengthening. STATEMENT OF SIGNIFICANCE: Although extensive research on the pathophysiology of dilated abdominal aortas (aneurysms) has been performed, the exact underlying pathways are still largely unclear. Previously, the macroscopic stiffness of the pathologic and healthy aortic wall has been studied. This study however, for the first time, studied the microscopic stiffness changes in live tissue of dilated and non-dilated abdominal aortas. This new protocol provides a device to analyse the alterations on cellular level within their microenvironment, whereas previous studies studied the aorta as a whole. Outcomes of these measurements might help to better understand the underlying origin of the incidence and progression of aneurysms and other aortic diseases.


Subject(s)
Aorta, Abdominal , Aortic Aneurysm, Abdominal , Elastic Modulus , Myocytes, Smooth Muscle , Vascular Stiffness , Adult , Aged , Aorta, Abdominal/metabolism , Aorta, Abdominal/pathology , Aorta, Abdominal/physiopathology , Aortic Aneurysm, Abdominal/metabolism , Aortic Aneurysm, Abdominal/pathology , Aortic Aneurysm, Abdominal/physiopathology , Female , Humans , Male , Middle Aged , Myocytes, Smooth Muscle/metabolism , Myocytes, Smooth Muscle/pathology
9.
Ann Vasc Surg ; 57: 244-252, 2019 May.
Article in English | MEDLINE | ID: mdl-30476618

ABSTRACT

BACKGROUND: The aim was to expand our understanding of the dynamic evolution of the aorta throughout the dissection time course. We investigated how the disease process can be modulated to equalize lumen pressure, enhance perfusion, and stabilize the aorta along its entire length using the kinetic elephant trunk (kET) technique. METHODS: We performed the kET on 9 patients with chronic symptomatic aortic dissection (CSAD) as a primary or secondary intervention, regardless of the chronicity of the dissection. Endovascular scissoring of the intraluminal septum is performed in the infradiaphragmatic dissected aorta to equalize pressure between true and false lumens and allow all branched vessels to be supplied from one lumen. The Streamliner Multilayer Flow Modulator (SMFM), an uncovered cobalt-alloy aortic device, is deployed from the aortic sinus, covering the supra-aortic branches, distally into the distal aorta (primary intervention). In the case of a previous ascending aorta Dacron graft, the SMFM is deployed (secondary intervention) at the level of the Dacron graft so that it is overlapped with the graft and landed in the distal aorta. RESULTS: In the initial study period, all-cause and aortic-related survival were 100%, respectively; all great vessels and visceral branches were patent; and freedom of stroke, end-organ ischemia, paraplegia, and renal failure were 100%. CONCLUSIONS: The kET is a treatment process for managing CSAD. Its simplicity, consistency, and reproducibility in high-risk patients with low morbidity and mortality add to the armamentarium of the cardiovascular specialist. Further assessment of the medium- and long-term outcomes is needed to fully establish the benefits of kET.


Subject(s)
Aortic Aneurysm/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/methods , Adult , Aged , Aortic Dissection/complications , Aortic Dissection/diagnostic imaging , Aortic Dissection/physiopathology , Angioscopy , Aortic Aneurysm/complications , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/physiopathology , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Chronic Disease , Computed Tomography Angiography , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Female , Humans , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Risk Factors , Treatment Outcome
10.
J Endovasc Ther ; 25(6): 760-764, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30354915

ABSTRACT

PURPOSE: To report Multilayer Flow Modulator (MFM) implantation from the sinotubular junction to the distal infrarenal aorta in the treatment of type B aortic dissection (TBAD) and demonstrate aortic remodeling using computational fluid dynamics (CFD) analysis over the course of 3-year follow-up. CASE REPORT: A hypertensive patient with complicated TBAD required thoracic endovascular aortic repair due to severe thoracic pain associated with rapid progression of the false lumen aneurysm toward the distal aortic arch. Under general anesthesia, 2 aortic multilayer stents were placed over a 0.035-inch stiff guidewire in the compressed true lumen. The aorta was covered with 2 MFM stents between the sinotubular junction and the distal infrarenal aorta. Serial computed tomography scans showed progressive remodeling of the entire dissected aortic wall, with an excellent result at 24 months. Morphological and CFD vascular analysis confirmed the aortic remodeling, with a false lumen index drop from a preoperative 4.04 to 0.01 at 36 months. CONCLUSION: Endovascular aortic repair with multilayer stents is a promising treatment for complicated TBAD due to the unique ability of these devices to stabilize the entire aortic wall without compromising the flow in the major aortic side branches.


Subject(s)
Aortic Aneurysm/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Computer Simulation , Endovascular Procedures/instrumentation , Models, Cardiovascular , Stents , Vascular Remodeling , Aortic Dissection/diagnostic imaging , Aortic Dissection/physiopathology , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/physiopathology , Humans , Hydrodynamics , Male , Middle Aged , Prosthesis Design , Time Factors , Treatment Outcome
11.
Medicine (Baltimore) ; 97(27): e11260, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29979391

ABSTRACT

RATIONALE: Streptococcus viridans, a heterogeneous group of alpha-hemolytic streptococci, is part of the normal flora of the mouth, usually responsible for dental caries (Streptococcus mutans, Streptococcus sanguinis), and pericoronitis, as well as for subacute infective endocarditis. They are responsible for 40-60% of the endocarditis cases occurring on the normal valves, especially in male patients and over 45 years of age. A change in the bacterial flora of the oral cavity is taking part after orthodontic fixed appliances are introduced into the oral cavity, change that is associated with an increased concentration of the acidogenic bacteria. Bacteraemia is the consequence of oral cavity infections, the association of infective endocarditis with fixed orthodontic appliance, as it has been described by us for the first time, caused by Abiotrophia defectiva. PATIENT CONCERNS: We present the case of a female Caucasian patient, aged 22 years, who developed infective endocarditis with Streptococcus viridans associated with fixed orthodontic appliance, located on the mitral valve, without previous cardiac pathology, and the therapeutic difficulties associated with allergic reactions (to vancomycin, and spironolactone). DIAGNOSES: Repetitive haemocultures were positive with Streptococcus viridans, while transthoracic echography revealed a severe mitral failure through anteromedial segment of the anterior mitral valve leaf prolapse with eccentric jet to the posterior wall. INTERVENTIONS: During hospitalization, the decision to undergo surgical intervention was taken after obtaining negative haemocultures. The patient underwent surgically intervention, and a mitral valve plasty with insertion of neochords was performed. OUTCOMES: Intraoperative and subsequently post-discharge transesophageal echography, highlighted normofunctional mitral plasty with a remaining regurgitation grade I-II of IV, with good openness, minor tricuspid regurgitation, and mild pulmonary hypertension. LESSONS: Endocarditis with oral streptococci associated with fixed orthodontic appliance seems to be not so unlikely even in young or without previous cardiac pathology patients, requiring attention in identifying possible pre-existing cardiac conditions like mitral valve prolapse with clinical and echographic monitoring of such cases. Educating and motivating the patient to observe the oral hygiene represent key steps for an optimal oral health during orthodontic treatment. Mechanical tooth cleaning helps maintaining a good oral hygiene during fixed orthodontics and decreasing the oral health risks.


Subject(s)
Endocarditis, Bacterial/microbiology , Endocarditis/surgery , Mitral Valve/surgery , Orthodontic Appliances/adverse effects , Streptococcal Infections/microbiology , Viridans Streptococci/isolation & purification , Echocardiography/methods , Endocarditis/complications , Endocarditis/etiology , Female , Heart Valve Diseases/complications , Heart Valve Diseases/pathology , Heart Valve Diseases/surgery , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/pathology , Oral Hygiene/education , Orthodontic Appliances/microbiology , Streptococcal Infections/complications , Treatment Outcome , Young Adult
12.
Vascular ; 26(2): 209-215, 2018 Apr.
Article in English | MEDLINE | ID: mdl-28836901

ABSTRACT

Traditional therapeutic options for complex thoracoabdominal aneurysm include open repair, hybrid repair or endovascular repair (involving fenestrated or branched endografts). The Streamliner Multilayer Flow Modulator has been available for treatment of thoracoabdominal aneurysms since 2010. Its design permits blood flow to perfuse through the mesh in a modus that preserves collateral branch patency, while modulating turbulent to laminar flow within the device. The flow then stagnates over time within the surrounding aneurysm sac. Significant complications, including paraplegia, renal failure and cerebrovascular accident, are much lower with Streamliner Multilayer Flow Modulator treatment. Application of the Streamliner Multilayer Flow Modulator to complex aortic pathologies presents a novel solution to an, as of yet, unmet clinical need, and has resulted in promising clinical outcomes when compared to existing solutions. The Streamliner Multilayer Flow Modulator offers potential for treatment of thoracoabdominal aortic pathologies in patients and is not just confined to those with complexity that dictates no other management options. While current literature illustrates that there is a decreased risk of mortality and associated complications when this new disruptive technology is utilised, there is still a need for prospective, long-term clinical trials, as well as comparative trials to accurately assess outcomes of Streamliner Multilayer Flow Modulator treatment that are both precise and reproducible. This article is a review of current clinical literature regarding contemporary flow modulating technology compared with open, branched and fenestrated managements, presenting early outcomes.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/methods , Endovascular Procedures/methods , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/mortality , Aortic Aneurysm, Thoracic/physiopathology , Blood Flow Velocity , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Humans , Postoperative Complications/etiology , Prosthesis Design , Regional Blood Flow , Risk Factors , Treatment Outcome
13.
Minerva Cardioangiol ; 66(2): 191-197, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29160044

ABSTRACT

Surgical aortic valve replacement (sAVR) has been a safe, effective and time-proven technique and is still the standard of care all over the world for aortic valve treatment. The vast majority of centers perform this procedure by doing a median sternotomy with several disadvantages. While many others specialties went minimally invasive decades ago, in cardiovascular field transcatheter valve implantation was the first minimally invasive valvular procedure that gained rapid worldwide acceptance. Transcatheter valve replacement (TAVR) is now marketed as a procedure that should be performed under local anesthesia, by an interventional cardiologist via trans femoral route with no other healthcare professional invited to the patient selection or case planning. An increasing number of surgeons are promoting minimally invasive aortic valve replacement, which is gaining grounds, especially with the help of the new sutureless valve technology. With these two new technologies emerging, legitimate questions arise and need to be answered - which has the longest durability, lower complication rate and lower overall mortality.


Subject(s)
Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Transcatheter Aortic Valve Replacement/methods , Humans , Minimally Invasive Surgical Procedures/methods , Sternotomy/methods , Sutureless Surgical Procedures/methods
14.
J Vasc Surg ; 65(4): 940-950, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28342521

ABSTRACT

OBJECTIVE: Reported are initial 12-month outcomes of patients with chronic symptomatic aortic dissection managed by the Streamliner Multilayer Flow Modulator (SMFM; Cardiatis, Isnes, Belgium). Primary end points were freedom from rupture- and aortic-related death, and reduction in false lumen index. Secondary end points were patency of great vessels and visceral branches, and freedom of stroke, paraplegia, and renal failure. METHODS: Out of 876 SMFM implanted globally, we have knowledge of 542. To date, 312 patients are maintained in the global registry, of which 38 patients were identified as having an aortic dissection (12.2%). Indications included 35 Stanford type B dissections, two Stanford type A and B dissections, and one mycotic Stanford type B dissection. RESULTS: There were no reported ruptures or aortic-related deaths. All cause survival was 85.3% Twelve-month freedom from neurologic events was 100%, and there were no incidences of end-organ ischemia, paraplegia or renal insult. Morphologic analysis exhibited dissection remodeling by a reduction in longitudinal length of the dissected aorta, and false lumen volume. A statistically significant reduction in false lumen index (P = .016) at 12 months, and a borderline significant increase in true lumen volume (P = .053) confirmed dissection remodeling. CONCLUSIONS: The SMFM is an option in management of complex pan-aortic dissection. Results highlight SMFM implantation leads to dissection stabilization with no further aneurysm progression, and no retrograde type A dissection. Thoracic endovascular aneurysm repair by SMFM ensued in freedom from aortic rupture, neurologic stroke, paraplegia and renal failure. Further analysis of the global registry data will inform long-term outcomes.


Subject(s)
Aneurysm, Infected/surgery , Aortic Aneurysm/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Endovascular Procedures/instrumentation , Adult , Aged , Aged, 80 and over , Aortic Dissection/diagnostic imaging , Aortic Dissection/physiopathology , Aneurysm, Infected/diagnostic imaging , Aneurysm, Infected/physiopathology , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/physiopathology , Aortography/methods , Blood Flow Velocity , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Chronic Disease , Computed Tomography Angiography , Disease-Free Survival , Endovascular Procedures/adverse effects , Europe , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Postoperative Complications , Prosthesis Design , Regional Blood Flow , Registries , Retrospective Studies , Time Factors , Treatment Outcome , United States , Vascular Patency
15.
J Endovasc Ther ; 23(5): 762-72, 2016 10.
Article in English | MEDLINE | ID: mdl-27280802

ABSTRACT

PURPOSE: To evaluate midterm outcomes of endovascular repair of types II and III thoracoabdominal aortic aneurysms (TAAA) using the Multilayer Flow Modulator (MFM) in patients unsuitable for open surgery or fenestrated stent-grafts. METHODS: In the prospective, multicenter, nonrandomized STRATO trial (EudraCT registration: 2009-013678-42; ClinicalTrials.gov identifier NCT01756911), 23 patients (mean age 75.8 years; 19 men) with Crawford type II and III TAAA (mean diameter 6.5 cm) were implanted between April 2010 and February 2011. Outcomes included all-cause mortality and stable aneurysm thrombosis with associated branch vessel patency. RESULTS: Through 36 months, there were 7 deaths (none confirmed as aneurysm-related), and no cases of spinal cord injury, device migration or fracture, or respiratory, renal, or peripheral complications. Three patients were lost to follow-up and 2 devices were explanted. The device was patent in the 11 remaining patients at 3 years. Stable aneurysm thrombosis was achieved for 15 of 20 patients at 12 months, 12 of 13 at 24 months, and 10 of 11 at 36 months. The rate of branch patency was 96% at 12 months (primary patency), 100% at 24 months, and 97% at 36 months. Nine patients suffered from endoleaks (attachment site or device overlap); 9 patients underwent 11 reinterventions (3 surgical). Maximum aneurysm diameter was stable for 18 of 20 patients at 12 months, 11 of 13 at 24 months, and 9 of 11 at 36 months. For 10 patients with computed tomography at 36 months, the mean ratio of aneurysm flow volume to total volume had decreased by 83%; the mean ratio of thrombus volume to total volume increased by 159%. CONCLUSION: Through 3 years, endovascular repair with the MFM appears to be safe and effective while successfully maintaining branch vessel patency.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Aged , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/mortality , Aortic Aneurysm, Thoracic/physiopathology , Aortography/methods , Blood Flow Velocity , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Computed Tomography Angiography , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , France , Humans , Kaplan-Meier Estimate , Male , Postoperative Complications/etiology , Prospective Studies , Prosthesis Design , Regional Blood Flow , Risk Factors , Time Factors , Treatment Outcome , Vascular Patency
17.
J Endovasc Ther ; 21(1): 85-95, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24502488

ABSTRACT

PURPOSE: To evaluate endovascular repair of type II and III thoracoabdominal aortic aneurysms (TAAA) using the Multilayer Flow Modulator (MFM) in patients with contraindications for open surgery and fenestrated stent-grafts. METHODS: In this prospective, multicenter, nonrandomized trial (EudraCT registration: 2009-013678-42; ClinicalTrials.gov identifier NCT01756911), 23 patients (19 men; mean age 75.8 years) with Crawford type II (43.5%) and III (56.5%) TAAA (mean diameter 6.5 cm) were treated with the MFM between April 2010 and February 2011. The primary efficacy outcome measure was stable aneurysm thrombosis with associated branch vessel patency at 12 months; the primary safety endpoint was 30-day and 12-month all-cause mortality. RESULTS: The rate of technical success was 100%. In 20 patients with computed tomography scans at 12 months, the primary efficacy outcome was met in 15 patients. The rate of primary patency of covered branch vessels was 96% (53/55); 1 patient with 2 occluded visceral branches underwent successful surgical reintervention. Endoleaks were identified in 5 patients (3 attachment site and 2 at device overlap), 4 of whom underwent reintervention (3 additional MFMs and 1 stent-graft implanted). At 12 months, aneurysm diameter was stable in 18 of 20 patients; the mean ratio of residual aneurysm flow volume to total volume had decreased by 28.9%, and the mean ratio of thrombus volume to total lumen volume had increased by 21.3% (n=17). There were no cases of device migration, loss of device integrity, spinal cord ischemia, or aneurysm rupture. CONCLUSION: At 1 year, endovascular repair with the MFM appears to be safe and effective while successfully maintaining branch vessel patency. Follow-up is ongoing.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Stents , Aged , Aged, 80 and over , Aortic Aneurysm, Thoracic/diagnosis , Aortic Aneurysm, Thoracic/physiopathology , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/etiology , Endoleak/therapy , Endovascular Procedures/adverse effects , Female , France , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/physiopathology , Graft Occlusion, Vascular/surgery , Humans , Male , Middle Aged , Prosthesis Design , Regional Blood Flow , Reoperation , Time Factors , Tomography, X-Ray Computed , Treatment Outcome , Vascular Patency
19.
Eur J Cardiothorac Surg ; 37(4): 888-92, 2010 Apr.
Article in English | MEDLINE | ID: mdl-19775906

ABSTRACT

OBJECTIVE: To provide a definition for recurrent sternal infection (RSI), analyse the risk factors and describe the management of this complication following treatment of deep sternal wound infection (DSWI) with horizontal titanium sternal osteosynthesis and coverage with pectoralis major myocutaneous flaps. METHODS: Between 2002 and 2007, 10665 patients were submitted to open-heart surgery (OHS) in our institution, of whom 149 (1.4%) developed a DSWI. Negative pressure wound therapy (NPWT) followed by sternal osteosynthesis with musculocutaneous coverage was used in 92 (61.7%) patients. A retrospective review was done using a prospectively maintained database to identify risk factors for recurrent infection in this group of patients. RESULTS: Of the 92 patients who underwent sternal osteosynthesis, nine (9.8%) developed recurrent sternal infection requiring hardware removal. Univariate analysis showed that preoperative methicillin-resistant Staphylococcus aureus (MRSA) status (33.3% vs 6.1%; p=0.03) and prolonged intubation time in ICU (44.4% vs 14.6%; p<0.05) were significant risk factors. Two-thirds of these patients were also found to be infected with the same germ as the one responsible for their initial DSWI. No death was reported and sternal integrity was preserved in all patients despite plate removal. CONCLUSIONS: To lower the rate of RSI in patients treated with transverse sternal ostheosynthesis along with myocutaneous coverage for DSWI, surgeons must consider the MRSA preoperative status as a significant predictor of RSI and/or persistent infection. Chest-wall integrity in patients with RSI can be maintained after hardware removal, even after only a few weeks following initial plating.


Subject(s)
Bone Plates , Cardiac Surgical Procedures , Negative-Pressure Wound Therapy , Sternum/surgery , Surgical Wound Infection/etiology , Aged , Debridement , Device Removal , Epidemiologic Methods , Female , Humans , Male , Mediastinitis/therapy , Middle Aged , Plastic Surgery Procedures/methods , Recurrence , Surgical Flaps , Surgical Wound Infection/therapy , Titanium
20.
Cardiovasc Pathol ; 19(3): e85-7, 2010.
Article in English | MEDLINE | ID: mdl-19144545

ABSTRACT

Cardiac invasion by lung cancer is associated with a poor prognosis. We describe the case of a large cell neuroendocrine carcinoma of the lung with left intra-atrial extension in a patient presenting with a catastrophic nutritional status.


Subject(s)
Carcinoma, Large Cell/complications , Carcinoma, Neuroendocrine/complications , Heart Atria/pathology , Heart Diseases/pathology , Thrombosis/pathology , Carcinoma, Large Cell/pathology , Carcinoma, Neuroendocrine/pathology , Echocardiography , Heart Diseases/etiology , Humans , Lung Neoplasms/pathology , Male , Middle Aged , Smoking/adverse effects , Thrombosis/etiology , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...