Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Mater Sci Eng C Mater Biol Appl ; 109: 110643, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32229007

ABSTRACT

Chronic wounds constitute a serious public health problem, and developing pharmaceutical dosage forms to ensure patient comfort and safety, as well as optimizing treatment effectiveness, are of great interest in the pharmaceutical, medical and biomaterial fields. In this work, the preparation of films based on blends of poly(vinyl alcohol), starch and poly(acrylic acid), polymers widely used as pharmaceutical excipients, and pomegranate peel extract (PPE), a bioactive compound with antimicrobial and healing activities relevant to the use as a bioactive wound dressing, was proposed. Initially, the minimum inhibitory concentration (MIC) of the PPE was investigated by an in vitro method. Then, the best concentration of the PPE to be used to prepare the films was researched using an antimicrobial susceptibility test with the disc diffusion method. The microbiological assay was performed in films prepared by the solvent casting method in the presence of two concentrations of PPE: 1.25% w/v and 2.5% w/v. Films containing the lower PPE concentration showed antimicrobial activity against Staphylococcus aureus and Staphylococcus epidermidis, with a difference that was not considered statistically significant when compared to the higher concentration of the extract. Therefore, the films prepared with the lower proportion of PPE (1.25% w/v) were considered for the other studies. The miscibility and stability of the extract in the films were investigated by thermal analysis. Parameters that determine the barrier properties of the films were also investigated by complementary techniques. Finally, in vitro biological tests were performed for safety evaluation and activity research. Analysis of the results showed that the incorporation of the higher proportion of starch in the blend (15% v/v) (PVA:S:PAA:PPE4) yielded smooth, transparent, and domain-free films without phase separation. Additionally, the PVA:S:PAA:PPE4 film presented barrier properties suitable for use as a cover. These films, when subjected to the in vitro hemolytic activity assay, were nonhemolytic and biocompatible. No toxicity from the extract was observed at the concentrations studied. The results of the wound healing in vitro test showed that films containing 1.25% PPE are efficient in reducing the scratch open area, provoking almost total closure of the scratches within 48 h without cytotoxicity.


Subject(s)
Anti-Bacterial Agents/chemistry , Bandages , Membranes, Artificial , Polyvinyl Alcohol/chemistry , Pomegranate/chemistry , Starch/chemistry , Animals , Cell Line , Mice , Staphylococcus aureus/growth & development , Staphylococcus epidermidis/growth & development
2.
J Mater Sci Mater Med ; 29(5): 67, 2018 May 10.
Article in English | MEDLINE | ID: mdl-29748753

ABSTRACT

Cooperation between researchers in the areas of medical, pharmaceutical and materials science has facilitated the development of pharmaceutical dosage forms that elicit therapeutic effects and protective action with a single product. In addition to optimizing pharmacologic action, such dosage forms provide greater patient comfort and increase success and treatment compliance. In the present work, we prepared semipermeable bioactive electrospun fibers for use as wound dressings containing silver sulfadiazine complexed with ß-cyclodextrin in a poly(Ɛ-caprolactone) nanofiber matrix aiming to reduce the direct contact between silver and skin and to modulate the drug release. Wound dressings were prepared by electrospinning, and were subjected to ATR-FT-IR and TG/DTG assays to evaluate drug stability. The hydrophilicity of the fibrous nanostructure in water and PBS buffer was studied by goniometry. Electrospun fibers permeability and swelling capacity were assessed, and a dissolution test was performed. In vitro biological tests were realized to investigate the biological compatibility and antimicrobial activity. We obtained flexible matrices that were each approximately 1.0 g in weight. The electrospun fibers were shown to be semipermeable, with water vapor transmission and swelling indexes compatible with the proposed objective. The hydrophilicity was moderate. Matrices containing pure drug modulated drug release adequately during 24 h but presented a high hemolytic index. Complexation promoted a decrease in the hemolytic index and in the drug release but did not negatively impact antimicrobial activity. The drug was released predominantly by diffusion. These results indicate that electrospun PCL matrices containing ß-cyclodextrin/silver sulfadiazine inclusion complexes are a promising pharmaceutical dosage form for wound healing.


Subject(s)
Drug Carriers/chemical synthesis , Nanofibers/chemistry , Polyesters/chemistry , Silver Sulfadiazine/administration & dosage , Wound Healing , beta-Cyclodextrins/administration & dosage , Bandages , Blood Cells/drug effects , Blood Cells/physiology , Chemical Phenomena , Dosage Forms , Drug Carriers/chemistry , Drug Carriers/pharmacokinetics , Drug Liberation , Drug Stability , Electroplating , Hemolysis/drug effects , Humans , Materials Testing , Microbial Sensitivity Tests , Silver Sulfadiazine/chemistry , Thermogravimetry , Wound Healing/drug effects , beta-Cyclodextrins/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...