Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Gait Posture ; 92: 129-134, 2022 02.
Article in English | MEDLINE | ID: mdl-34844151

ABSTRACT

BACKGROUND: There is a range of magneto-inertial measurement unit (MIMU) systems commercially available, however sensor specifications and fusion methods vary considerably between manufacturers. Such variability can influence the concurrent validity of MIMUs relative to reference standard measurement devices. Different MIMUs have been compared during static or low-velocity conditions, with higher-velocity movements assessed in robotic-based studies. However, there is a need for the concurrent validity of higher-velocity movements to be established in human-based studies. RESEARCH QUESTION: This study aimed to assess the concurrent validity of two commercial MIMU systems (Noraxon and Xsens), relative to a 'gold-standard' retro-reflective motion capture system, when measuring trunk angles during uni-planar range of motion (ROM) and cricket bowling, which involves high-speed, multi-planar movements. METHODS: For this criterion-based validity study, both MIMU systems incorporated comparable sensor specifications and employed Kalman filter sensor fusion algorithms. The MIMU based angles were compared with angles derived from concurrently captured three-dimensional retro-reflective data for 10 fast-medium bowlers. Statistical parametric mapping and root mean squared differences (RMSD) were computed for both MIMU systems. RESULTS: One-dimensional statistical parametric mapping showed no significant differences for angles from both MIMU systems when compared with retro-reflective based angle outputs. The MIMU systems produced ROM RMSDs between 1.4 ± 1.0° and 2.6 ± 1.5°. One system displayed RMSDs between 4.6 ± 1.4° and 7.4 ± 1.9° during bowling, indicating functionally relevant differences to retro-reflective derived angles. There were some small but statistically significant differences in RMSDs between the MIMU systems. SIGNIFICANCE: MIMU-based angle accuracy is poorer during high-speed, multi-planar movement than uni-planar tasks. Comparable MIMU systems can produce varying measurements during ROM and bowling tasks. It is likely that varying sample rates and sensor fusion algorithm parameters contributed to the differences.


Subject(s)
Movement , Sports , Biomechanical Phenomena , Humans , Range of Motion, Articular , Torso
2.
Med Biol Eng Comput ; 59(11-12): 2253-2262, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34529184

ABSTRACT

 Magneto-inertial measurement unit (MIMU) systems allow calculation of simple sensor-to-sensor Euler angles, though this process does not address sensor-to-segment alignment, which is important for deriving meaningful MIMU-based kinematics. Functional sensor-to-segment calibrations have improved concurrent validity for elbow and knee angle measurements but have not yet been comprehensively investigated for trunk or sport-specific movements. This study aimed to determine the influence of MIMU functional calibration on thorax and lumbar joint angles during uni-planar and multi-planar, sport-specific tasks. It was hypothesised that functionally calibrating segment axes prior to angle decomposition would produce smaller differences than a non-functional method when both approaches were compared with concurrently collected 3D retro-reflective derived angles. Movements of 10 fast-medium cricket bowlers were simultaneously recorded by MIMUs and retro-reflective motion capture. Joint angles derived from four different segment definitions were compared, with three incorporating functionally defined axes. Statistical parametric mapping and root mean squared differences (RMSD) quantified measurement differences one-dimensionally and zero-dimensionally, respectively. Statistical parametric mapping found no significant differences between MIMU and retro-reflective data for any method across bowling and uni-planar trunk movements. The RMSDs for the functionally calibrated methods and non-functional method were not significantly different. Functional segment calibration may be unnecessary for MIMU-based measurement of thorax and lumbar joint angles.


Subject(s)
Knee Joint , Wearable Electronic Devices , Biomechanical Phenomena , Calibration , Humans , Range of Motion, Articular , Thorax
SELECTION OF CITATIONS
SEARCH DETAIL
...