Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Environ Pollut ; 169: 98-104, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22705502

ABSTRACT

The polar organic chemical integrative sampler (POCIS) was calibrated to monitor pesticides in water under controlled laboratory conditions. The effect of natural organic matter (NOM) on the sampling rates (R(s)) was evaluated in microcosms containing <0.1-5 mg L(-1) of total organic carbon (TOC). The effect of hydrodynamics was studied by comparing R(s) values measured in stirred (SBE) and quiescent (QBE) batch experiments and a flow-through system (FTS). The level of NOM in the water used in these experiments had no effect on the magnitude of the pesticide sampling rates (p > 0.05). However, flow velocity and turbulence significantly increased the sampling rates of the pesticides in the FTS and SBE compared to the QBE (p < 0.001). The calibration data generated can be used to derive pesticide concentrations in water from POCIS deployed in stagnant and turbulent environmental systems without correction for NOM.


Subject(s)
Environmental Monitoring/methods , Organic Chemicals/chemistry , Pesticides/chemistry , Water Pollutants, Chemical/chemistry , Environmental Monitoring/instrumentation , Hydrodynamics , Kinetics , Pesticides/isolation & purification , Water Pollutants, Chemical/isolation & purification
2.
Chemosphere ; 72(8): 1171-80, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18499223

ABSTRACT

Paper mill effluents may contain polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) that are normally generated due to chlorinated bleaching of pulp and paper. We used the semipermeable membrane device (SPMD) to monitor PCDD/F levels upstream and downstream of a paper mill on the Androscoggin River, in Jay (ME). Following the 36 day deployment, SPMD dialysis and cleanup, the samples were analyzed by HRGC/HRMS. Total concentrations of PCDD/Fs in SPMDs (sum of all tetra-through octachlorinated congeners) ranged from 4.71 pg g(-1) to 26.26 pg g(-1). Five out of the targeted 17 toxic congeners were detected, including: 2,3,7,8-TCDF; 1,2,3,7,8-PeCDF; 2,3,4,7,8-PeCDF; 1,2,3,4,6,7,8-HpCDD and OCDD. Permeability reference compounds (PRCs) were used for in situ calibration of the SPMD sampling rate (Rs). In all sites, water concentrations were the highest for OCDD (0.081-0.103 pg l(-1)), and the lowest for 1,2,3,7,8-PeCDF (0.005-0.009 pg l(-1)). There was not a consistent pattern of upstream-downstream gradient in the PCDD/F levels. This suggested that processes other than the mill in Jay (multiple sources, river dynamics) governed the flux of PCDD/Fs in the sampling locations. The SPMD results were validated by comparison to other studies on the Androscoggin River and elsewhere, confirming the potential of the device as a useful monitoring technique for PCDD/Fs in large river systems.


Subject(s)
Benzofurans/analysis , Industrial Waste/analysis , Paper , Polychlorinated Dibenzodioxins/analogs & derivatives , Water Pollutants, Chemical/analysis , Dibenzofurans, Polychlorinated , Environmental Monitoring , Geography , Maine , Polychlorinated Dibenzodioxins/analysis , Rivers
SELECTION OF CITATIONS
SEARCH DETAIL
...