Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Br J Radiol ; 94(1118): 20201166, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33332980

ABSTRACT

OBJECTIVE: To compare positive predictive values (PPVs) of clumped vs non-clumped (homogenous and heterogeneous) internal enhancement on MRI detected linear non-mass enhancement (NME) on MRI-guided vacuum-assisted breast biopsy (MRI-VABB). METHODS: With IRB (Institutional Review Board) approval, we retrospectively reviewed 598 lesions undergoing MRI-VABB from January 2015 to April 2018 that showed linear NME. We reviewed the electronic medical records for MRI-VABB pathology, any subsequent surgery and clinical follow-up. The X2 test was performed for univariate analysis. RESULTS: There were 120/598 (20%) linear NME MRI-VABB lesions with clumped (52/120, 43%) vs non-clumped (68/120, 57%) internal enhancement, average size 1.8 cm (range 0.6-7.6 cm). On MRI-VABB, cancer was identified in 22/120 (18%) lesions, ductal carcinoma in situ (DCIS) was found in 18/22 (82%) and invasive cancer in 4 (18%). 3/31 (10%) high-risk lesions upgraded to DCIS at surgery, for a total of 25/120 (21%) malignancies. Malignancy was found in 12/52 (23%) clumped lesions and in 13/68 (19%) of non-clumped lesions that showed heterogeneous (5/13, 38%) or homogenous (8/13, 62%) internal enhancement. The PPV of linear NME with clumped internal enhancement (23.1%) was not significantly different from the PPV of non-clumped linear NME (19.1%) (p = 0.597). The PPV of linear NME lesions <1 cm (33.3%) was not significantly different from the PPV of lesions ≥1 cm (18.6%) (p = 0.157). CONCLUSIONS: Linear NME showed malignancy in 21% of our series. Linear NME with clumped or non-clumped internal enhancement patterns, regardless of lesion size, might need to undergo MRI-VABB in appropriate populations. ADVANCES IN KNOWLEDGE: Evaluation of linear NME lesions on breast MRI focuses especially on internal enhancement pattern.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Magnetic Resonance Imaging/methods , Adult , Aged , Aged, 80 and over , Breast/diagnostic imaging , Breast/pathology , Female , Humans , Image-Guided Biopsy , Middle Aged , Retrospective Studies , Vacuum
2.
Breast Cancer ; 27(3): 405-414, 2020 May.
Article in English | MEDLINE | ID: mdl-31838725

ABSTRACT

BACKGROUND: To evaluate imaging characteristics, outcome of surgical excision or imaging follow-up on high-risk lesions diagnosed at MRI-guided vacuum-assisted breast biopsy (MRI-VABB). METHODS: We retrospectively reviewed 598 lesions undergoing 9-gauge MRI-VABB from January 2015 to April 2018 to identify high risk breast lesions. We collected patient demographics, breast MRI BI-RADS descriptors, histopathological diagnosis at MRI-VABB and surgical excision, frequency of upgrade to malignancy and imaging follow-up of high-risk lesions. The x2 test and Fisher exact tests were performed for univariate analysis. RESULTS: 114 patients with 124/598 findings (20.7%) had high-risk lesions at MRI-VABB, including atypical ductal hyperplasia (ADH) (21/124, 16.9%), lobular neoplasia (40/124, 32.3%), radial scar/complex sclerosing lesion (RS/CSL) (13/124, 10.5%), papillary lesions (49/124, 39.5%), and flat epithelial atypia (FEA) (1/124, 0.8%). 84/124 (67.7%) high-risk lesions were excised. 19/84 (22.6%) were upgraded to malignancy (7 invasive cancer, 12 DCIS). The upgrade rate for ADH and lobular neoplasia was 7/18 (38.9%) and 9/31 (29.0%), respectively. The upgrade rate for RS/CSL was 1/10 (10%). Of the 25 papillary lesions excised, 2 (8%) demonstrated pathologic atypia and were upgraded to DCIS. The other 23 papillary lesions had no upgrade or atypia. Excised high-risk lesions showing upgrade varied from 0.4 to 6 cm in length (mean 1.6 cm). There was a non-significant trend (p = 0.054) between larger lesion and upgrade to malignancy; however, there were no other specific imaging features to predict malignancy upgrade. CONCLUSIONS: There were no specific MRI imaging characteristics of high-risk lesions to predict malignancy upgrade. Therefore, surgical excision is recommended for high-risk lesions, especially ADH or lobular neoplasia.


Subject(s)
Breast Neoplasms/pathology , Carcinoma, Ductal, Breast/pathology , Carcinoma, Intraductal, Noninfiltrating/pathology , Carcinoma, Lobular/pathology , Image-Guided Biopsy/methods , Magnetic Resonance Imaging/methods , Mammography/methods , Adult , Aged , Aged, 80 and over , Breast Neoplasms/surgery , Carcinoma, Ductal, Breast/surgery , Carcinoma, Intraductal, Noninfiltrating/surgery , Carcinoma, Lobular/surgery , Female , Follow-Up Studies , Humans , Lymphatic Metastasis , Middle Aged , Neoplasm Invasiveness , Prognosis , Retrospective Studies , Vacuum , Young Adult
3.
J Breast Imaging ; 2(2): 141-146, 2020 Mar 25.
Article in English | MEDLINE | ID: mdl-38424890

ABSTRACT

OBJECTIVE: Fibrocystic change (FCC) is considered one of the most common benign findings in the breast and may be commonly seen on breast MRI. We performed this study to identify MRI characteristics of pure FCC on MRI-guided vacuum-assisted breast biopsy (VABB) without other associated pathologies and describe the findings on MRI follow-up and outcomes. METHODS: A retrospective review was performed for 598 lesions undergoing 9-gauge MRI-guided VABB at our institution from January 2015 to April 2018, identifying 49 pure FCC lesions in 43 patients. The associations between variables and lesion changes on follow-up MRI were analyzed using exact Mann-Whitney tests and Fisher's exact tests. RESULTS: MRI features of pure FCC are predominantly clumped nonmass enhancement (19/49, 39%) or irregular masses with initial fast/late washout kinetics (9/49, 18%). There was no upgrade to high-risk or cancerous lesions among the 11 patients (25.6%) who underwent surgery. There were 22 pure FCC lesions in 19 (44.2%) patients who had follow-up MRI (mean 18.0 months, range 11-41 months) showing regression (13, 59%), stability (8, 36%), or progression (1, 5%) of the lesion size, and no cancers were found on follow-up at the site of the MRI biopsy for fibrocystic changes. No patient demographics or lesion features were associated with lesion regression or stability (P > 0.05). CONCLUSION: Our study shows that MRI features of VABB-proven FCC lesions may mimic malignancy. After VABB of pure FCC, given that adequate sampling has been performed, a 12-month follow-up MRI may be reasonable.

4.
AJR Am J Roentgenol ; 212(1): 180-187, 2019 01.
Article in English | MEDLINE | ID: mdl-30383407

ABSTRACT

OBJECTIVE: The objective of our study was to determine the feasibility and accuracy of MRI for pediatric appendicitis in an adult-predominant general hospital setting where non-pediatric-trained radiologists routinely interpret the studies. MATERIALS AND METHODS: MRI was performed in pediatric patients with equivocal ultrasound (US) findings and persistent clinical concern for appendicitis. Neither IV contrast material nor a sedative was administered. Our MRI protocol evolved early during the study period, quickly settling on three sequences (total scanning time, 11 minutes). The clinical reference standard for statistical analysis was appendicitis diagnosed on operative or pathology report; 95% Clopper-Pearson CIs were calculated. RESULTS: Between 2012 and 2016, 528 pediatric patients (mean age, 9.9 years; age range, 1-17 years) underwent MRI after US evaluation yielded equivocal findings: 10.4% (55/528) of patients were found to have surgically proven or pathologically proven appendicitis. Sensitivity and specificity of MRI for appendicitis were 96.4% and 98.9%, respectively. Positive and negative predictive values were 91.2% and 99.6%. A normal appendix and abnormalities not involving the appendix were identified on MRI in 21.6% (114/528) of patients. CONCLUSION: Our data show that unenhanced MRI for suspected appendicitis in pediatric patients is clinically effective when performed in a nonpediatric hospital setting with nonpediatric radiologists, emergency physicians, and surgeons.


Subject(s)
Appendicitis/diagnostic imaging , Clinical Competence , Emergency Service, Hospital/standards , Magnetic Resonance Imaging/methods , Radiologists/standards , Surgeons/standards , Adolescent , Algorithms , Appendicitis/surgery , Child , Child, Preschool , Diagnosis, Differential , Emergencies , Female , Hospitals, General , Humans , Infant , Male , Sensitivity and Specificity , Ultrasonography/methods
5.
Radiol Case Rep ; 13(6): 1163-1165, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30233751

ABSTRACT

Coalition of the carpal bones is a relatively uncommon anatomic anomaly. The majority of carpal coalitions occur between the lunate and triquetrum. There are rare reports of coalition involving the hamate and pisiform. We report a case of a previously asymptomatic male who sustained minor trauma and was found to have hamate-pisiform coalition complicated by a minimally displaced pisiform fracture.

6.
Case Rep Radiol ; 2018: 4809650, 2018.
Article in English | MEDLINE | ID: mdl-30112244

ABSTRACT

Intussusception of the appendix is a relatively rare event that is usually asymptomatic but can present similar to other acute and chronic abdominal conditions. We present two separate cases of suspected appendiceal intussusception mimicking cecal masses. The authors also present a cursory review of the limited number of literatures available concerning this entity to help the radiologist avoid misdiagnosis and potentially unnecessary invasive intervention.

SELECTION OF CITATIONS
SEARCH DETAIL
...