1.
Biomaterials ; 25(17): 3813-28, 2004 Aug.
Article in English | MEDLINE | ID: mdl-15020157

ABSTRACT

This paper presents methods, results and analysis for measurements of the electrochemical impedance of platinum electrodes (approximately 0.43 mm2) over a 6-month implantation in the cat cochlea. The study aimed to improve our understanding of the effects of tissue response on impedance behaviour. An increase in impedance in the post-operative period was evident with a rise of the distorted arc at high frequencies in the complex plane, correlating to anomalous charge transport at the electrode-tissue interface. The impedance at low frequencies generally showed a capacitive dispersion modelled as a constant phase element, indicating a blocking characteristic of the electrodes. The study suggests that a reduction and changes in composition of perilymph or extracellular fluid adjacent to the electrodes, as a consequence of tissue response, causes the elevated "contact impedance". This affects the efficiency and quality of neural stimulating electrodes and neural recording electrodes. The finding of the crucial role of perilymph or extracellular fluid thin layer provides a new strategy for surface materials of neural electrodes, which is discussed in the paper. The interface characteristics must be considered during interpretation of studies undertaken in vitro or in acute experiments in vivo, where physiological fluid is abundant.


Subject(s)
Cochlear Implants/adverse effects , Electrochemistry/methods , Electrodes, Implanted , Equipment Failure Analysis/methods , Foreign Bodies/physiopathology , Materials Testing/methods , Microelectrodes , Animals , Biocompatible Materials/chemistry , Cats , Computer Simulation , Electric Impedance , Electrochemistry/instrumentation , Foreign Bodies/etiology , Foreign Bodies/pathology , Models, Biological , Surface Properties
2.
Ear Hear ; 23(1 Suppl): 18S-27S, 2002 Feb.
Article in English | MEDLINE | ID: mdl-11885571

ABSTRACT

OBJECTIVE: The main objective of this study was to assess whether speech perception and speech production in children using the Nucleus 24 cochlear implant system improved with a change in speech processing strategy from the SPEAK to the Advanced Combination Encoder (ACE) strategy. The major difference between the two strategies is that ACE uses a higher stimulation rate (in this study the stimulation rate was 900 Hz per channel) compared with the SPEAK strategy, where the stimulation rate is 250 Hz per channel. Information also was obtained regarding the adjustment period after conversion to the ACE strategy. DESIGN: An ABA experimental design was used where scores were initially obtained using the SPEAK strategy' (in the initial A time interval), and subsequently performance was assessed using the ACE strategy (B time interval) and then again with the SPEAK strategy (second A time interval). The duration of the B interval was 10 wk, and the duration for the second A interval was 4 wk. Seven children aged between 9 and 16 yr who had at least 6 mo experience with the SPEAK strategy participated. Open-set monosyllabic CNC word perception in quiet and Speech Intelligibility Test sentence perception in noise was evaluated at the end of each of the time intervals. Word perception was also monitored at fortnightly intervals during the B time interval. Speech production was assessed at the end of the initial A time interval and at the end of the B time interval. RESULTS: Mean word and phoneme scores for open-set words in quiet for the group of seven children were significantly higher with the ACE strategy as compared with the SPEAK strategy scores obtained in both of the A time intervals. For sentences in noise, mean scores using the ACE strategy as well as the SPEAK strategy at the second A evaluation point were significantly higher than the scores using the SPEAK strategy measured at the first A time interval. This suggests that learning effects may have influenced outcomes. For some subjects, an initial decrease in scores was found during the initial 2-wk period after fitting the ACE strategy; however, scores subsequently were found to be similar to or higher than those when using the initial SPEAK strategy. Analysis of speech production assessments showed an improvement in the medial consonant scores after using the ACE strategy. CONCLUSIONS: This study demonstrated that some children were able to benefit from the additional information provided by the ACE strategy as compared with the SPEAK strategy. However, the differences in overall performance between the two strategies appear to be relatively small.


Subject(s)
Acoustic Stimulation/instrumentation , Cochlear Implantation , Deafness/rehabilitation , Speech Perception/physiology , Adolescent , Child , Equipment Design , Female , Humans , Male , Speech Production Measurement