Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Clin Oncol (R Coll Radiol) ; 33(5): e225-e231, 2021 05.
Article in English | MEDLINE | ID: mdl-33402268

ABSTRACT

AIMS: Self-expanding metal stents provide rapid improvement of dysphagia in oesophageal cancer but are associated with complications. The aim of the present study was to test the effectiveness of an alternative treatment of combining biodegradable stents with radiotherapy. MATERIALS AND METHODS: A Simon two-stage single-arm prospective phase II trial design was used to determine the efficacy of biodegradable stents plus radiotherapy in patients with dysphagia caused by oesophagus cancer who were unsuitable for radical treatment. Fourteen patients were recruited and data from 12 were included in the final analyses. RESULTS: Five of 12 patients met the primary end point: one stent-related patient death; four further interventions for dysphagia within 16 weeks of stenting (41.7%, 95% confidence interval 15.2-72.3%). The median time to a 10-point deterioration of quality of life was 2.7 weeks. Nine patients died within 52 weeks of registration. The median time to death from any cause was 15.0 weeks (95% confidence interval 9.6-not reached). CONCLUSION: The high re-intervention observed, which met the pre-defined early stopping criteria, meant that the suggested alternative treatment was not sufficiently effective to be considered for a larger scale trial design. Further work is needed to define the place of biodegradable stents in the management of malignant oesophageal strictures.


Subject(s)
Deglutition Disorders , Esophageal Neoplasms , Esophageal Stenosis , Deglutition Disorders/etiology , Esophageal Neoplasms/complications , Esophageal Neoplasms/radiotherapy , Esophageal Stenosis/etiology , Esophageal Stenosis/radiotherapy , Humans , Palliative Care , Prospective Studies , Quality of Life , Stents , Treatment Outcome
2.
BMJ Open Respir Res ; 3(1): e000156, 2016.
Article in English | MEDLINE | ID: mdl-27843550

ABSTRACT

INTRODUCTION: Solitary pulmonary nodules (SPNs) are common on CT. The most cost-effective investigation algorithm is still to be determined. Dynamic contrast-enhanced CT (DCE-CT) is an established diagnostic test not widely available in the UK currently. METHODS AND ANALYSIS: The SPUtNIk study will assess the diagnostic accuracy, clinical utility and cost-effectiveness of DCE-CT, alongside the current CT and 18-flurodeoxyglucose-positron emission tomography) (18FDG-PET)-CT nodule characterisation strategies in the National Health Service (NHS). Image acquisition and data analysis for 18FDG-PET-CT and DCE-CT will follow a standardised protocol with central review of 10% to ensure quality assurance. Decision analytic modelling will assess the likely costs and health outcomes resulting from incorporation of DCE-CT into management strategies for patients with SPNs. ETHICS AND DISSEMINATION: Approval has been granted by the South West Research Ethics Committee. Ethics reference number 12/SW/0206. The results of the trial will be presented at national and international meetings and published in an Health Technology Assessment (HTA) Monograph and in peer-reviewed journals. TRIAL REGISTRATION NUMBER: ISRCTN30784948; Pre-results.

SELECTION OF CITATIONS
SEARCH DETAIL