Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Publication year range
1.
Pacing Clin Electrophysiol ; 45(12): 1345-1348, 2022 12.
Article in English | MEDLINE | ID: mdl-36208140

ABSTRACT

An 80-year-old woman received a dual chamber pacemaker (Boston Scientific Accolade MRI DR) for pre-syncopal episodes associated with transient II-degree atrioventricular block type 1 and 2:1, recorded in 24-h Holter monitoring. Due to residual AV conduction with I-degree AV block, the pacemaker was set with the RYTHMIQ® algorithm, in order to reduce inappropriate ventricular pacing. A month later the patient started to complain of severe asthenia and bradycardia (46-48 bpm). Telemetry-supported pacemaker control revealed III-degree AV block with junctional escape rhythm, unmasking missed switch of RYTHMIQ® algorithm.


Subject(s)
Atrioventricular Block , Humans , Aged, 80 and over , Atrioventricular Block/therapy
3.
Minerva Cardiol Angiol ; 69(4): 429-434, 2021 08.
Article in English | MEDLINE | ID: mdl-32657559

ABSTRACT

BACKGROUND: Differentiation of Type 2 Brugada Pattern (BP) from incomplete right bundle branch block or normal rSr' pattern can be insidious. The aim of this study was to assess interobserver and intraobserver agreement in the diagnosis of type 2 BP in a cohort of cardiologists with different skills. METHODS: We collected 14 ECGs with a positive terminal deflection of the QRS complex in lead V1 and V2 at the 4th intercostal space. We proposed these ECGs, specifying to use 2012 Consensus conference criteria for diagnosis of type 2 BP, to 42 participants: 14 arrhythmologists, 14 general cardiologists and 14 electrophysiology (EP) fellows. The same 14 ECGs, with a different order, were proposed fifteen days later to the same cohort to assess intraobserver variability. Authors analyzed all 14 ECGs in order to assess whether 2012 Consensus Conference criteria for BP were fulfilled. All patients underwent provocative test with IC antiarrhythmics drugs (flecainide) in order to exclude or confirm the diagnosis of Brugada Syndrome (BrS). RESULTS: Slight interobserver agreement (Fleiss K<0.20) in the diagnosis of type 2 BP was observed in all three categories of cardiologists. Considering five operators per class, intraobserver agreement is variable (k ranging from 0.000 to 0.857), with a slight superiority of arrhytmologists (k minimum value 0.276; k maximum value 0.857). CONCLUSIONS: This study demonstrated, for the first time, a low interobserver agreement in diagnosis of type 2 BP in categories of cardiologists with different abilities. Reproducibility of type 2 BP diagnosis (intraobserver agreement) is poor, even among experts. These findings highlight the difficulties in analysis of ECG with BrS suspicion and, therefore, underscore the key role of clinical and anamnestic data.


Subject(s)
Brugada Syndrome , Anti-Arrhythmia Agents , Brugada Syndrome/diagnosis , Bundle-Branch Block , Electrocardiography , Humans , Reproducibility of Results
4.
Rev. esp. cardiol. (Ed. impr.) ; 73(12): 1064-1064, dic. 2020. ilus
Article in Spanish | IBECS | ID: ibc-201135

ABSTRACT

No disponible


Subject(s)
Humans , Electrocardiography
5.
Rev Esp Cardiol (Engl Ed) ; 73(12): 1064, 2020 12.
Article in English, Spanish | MEDLINE | ID: mdl-33250140
7.
Rev Esp Cardiol (Engl Ed) ; 73(11): 951, 2020 11.
Article in English, Spanish | MEDLINE | ID: mdl-34756205
SELECTION OF CITATIONS
SEARCH DETAIL
...